Smearing when the rollers are subjected to se-

vere acceleration on their entry into


the ends of the rollers. This smearing
is attributable to insufficient lubricant
When two inadequately lubricated sur- the load zone. If the bearing rings ro- between flanges and rollers. It occurs
faces slide against each other under tate relative to the shaft or housing, when a heavy axial load acts in one
load, material is transferred from one this may also cause smearing in the direction over a long period, for instan-
surface to the other. This is known as bore and on the outside surface and ce when taper roller bearings are sub-
smearing and the surfaces concerned ring faces. ject to excessive preloading. In cases
become scored, with a “torn” appear- In thrust ball bearings, smearing where the axial load changes direction,
ance. When smearing occurs, the may occur if the load is too light in smearing is much less common as the
material is generally heated to such relation to the speed of rotation. opportunity is provided for the ingress
temperatures that rehardening takes of lubricant when the roller end is tem-
place. This produces localised stress Smearing of roller ends and guide porarily relieved of load. Such smear-
concentrations that may cause crack- flanges ing can be avoided to a considerable
ing or flaking. In cylindrical and taper roller bearings, extent by selecting a suitable lubricant.
In rolling bearings, sliding primarily and in spherical roller bearings with
occurs at the roller end-guide flange guide flanges, smearing may occur on
interfaces. Smearing may also arise the guiding faces of the flanges and

Appearance Cause Action


Scored and discoloured roller ends Sliding under heavy axial loading and More suitable lubricant.
and flange faces. with inadequate lubrication.

Fig 32 Smearing on the surface of a roller Fig 33 A cylindrical roller with end smear- Fig 34 Guide flange smearing attributable
from a spherical roller bearing – 100 × mag- ing caused by heavy axial loading and to the same causes as the smearing shown
nification improper lubrication in fig 33

32 33 34

17