A1,A2 : Source
CREATED ON: June 11, 2014 DOC NO.: OD RS YN 18001 0 REV NO.: 01 Dtd: 11/06/2014 Page 1 of 4
Programming Instruction: Copy Channel Programming:
CREATED ON: June 11, 2014 DOC NO.: OD RS YN 18001 0 Dtd: 11/06/2014 Page 2 of 4
1) Cascading of two Sequential timers
DISPOSITION CONTACT
EAPL Sequential timers with O1- O2 & S1- S2 Fecility
can be cascaded to get more no of channels. Once the product life is over, you may Electronic Automation Pvt. Ltd
send back the unit to EAPL for #20, KHB Industrial area
Single cycle operation disposition. Yelahanka
Bangalore -64
Connect O1 of the First timer to S1 of Second timer & TROUBLE ANALYSIS
O2 of the first timer to S2 of Second timer. Ph:+91-80-
C1-C2 of both timers shall be shorted for Single Timing not initiated. 28567561/2/42802345
operation. S1-S2 of first timer shall be Shorted manually S1- S2 start signal shall be
to initiate the Function. Refer: Page No:04 of 04 applied. Email :
info@eaplindiamail.com
HINTS ON CORRECT USAGE www.eaplindia.com
CAUTION
Shorting of S1-S2 shall be potential free;
applying power to these terminals will damage
the timer permanently.