Guaranteed Technical Particulars 8 161 kV Transmission line Project In Togo

a) Clamp b) Messenger cable c) Damper weight

19 Quantity of zinc and standard to which conforming

20 Galvanization
(a) method of galvanization
i) Spring washers
ii) Other spare parts
(b) no. of dips
i) One minute
ii) Half minute
(c) minimum weight of zinc coating (g/sq. m)
i) Casting
ii) Wires
21 Certification Mark (ISI/BS/or any other
International Standard)
22 Packing details
i) Marking
ii) Standard to which conforming

V OPGW ACCESSORIES
A. SUSPENSION ASSEMBLY
1 Manufacturer's name & address
2 Type
3 Material
4 Drawing no. (give complete details and dimension
including no. of components)
5 Reference of Indian Standard specification to which
conform
6 Minimum slip strength with respect to earth wire

7 Minimum ultimate breaking strength


8 Galvanising
(a) Spring washers
(b) Other ferrous parts
(c) weight of zinc (g/sq. m)
(d) no. of dips
i) one minute
ii) half minute
(e) Quality of zinc and standard to which
conforming
9 Fixing arrangement of clamp on the ground wire /
OPGW
10 Whether the limb of the U-bolt has been long
enough to accommodate the leg of the flexible
copper bond (Y/N)
11 Total drop of the suspension assembly from the
centre point of the attachment to the centre point
of the ground wire (mm)
12 Certification Mark (ISI/BS/Any other International
Standard)
13 Total weight of assembly (kg)
14 Method of manufacture adopted e.g. forging or
casting
15 Packing details
16 Other details, if any

B. TENSION ASSEMBLY
1 Manufacturer's name & address
2 Type
3 Material
(a) Body
(b) Bolts and nuts
4 Drawing no. (give complete details and dimension
and no. of components)


Volume-II-Section-IV 8/17
Guaranteed Technical Particulars 9 161 kV Transmission line Project In Togo

5 Reference of Indian Standard specification / IEC to


which conforms
6 Minimum slip strength
7 Minimum ultimate breaking strength
8 Brinnel hardness of steel
9 Galvanising
(a) Spring washers
(b) Other ferrous parts
(c) weight of zinc (g/sq. m)
(d) no. of dips
i) one minute
ii) half minute
(e) Quality of zinc and standard to which
conforming
10 Total weight of complete assembly (kg)
11 Breaking strength of tension clamp as % of
breaking load of ground wire
12 Resistivity as % of equivalent length of ground wire

13 Whether lugs along with necessary nuts and bolts


for jumper connections will be supplied (Y/N)

14 Angle of Jumper terminal with the vertical plate


(degree)
15 Whether the bolt holding the jumper is sufficiently
long and will be provided with washers, nuts and
locking nuts etc., for fixing one lug of the flexible
copper bond (Y/N0)
16 Certification Mark (ISI/BS/or Any other
International Standard)
17 Packing details
18 Other details, if any
C. VIBRATION DAMPERS
1 Maker's name & Country
2 Type
3 Suitable for earth wire of size (mm)
4 Material with reference of ISS to which it conforms

(a) Clamp
(b) Messenger cable
(c) Weight
5 Reference of manufacturer's drawing and
catalogue no. etc.
6 Total weight of each damper (kg)
7 Dimensions of balancing weights (mm)
8 Length of each balancing weight (mm)
9 Weight of each balancing weight (kg)
10 Tolerance in balancing weights (+%)
11 Messenger cable
(a) Stranding and wire diameter (mm)
(b) Ultimate tensile strength (kg)
(c) Ultimate bending strength (kg m)
12 Slipping strength of stranded messenger cable with
respect to balancing weight (kg)
13 (a) Diagram showing power dissipated by the
damper in watts for various vibration frequencies &
amplitudes (watts)
(b) Diagram showing the vibration energy for
various frequencies under varied winds and spans

14 Natural frequency of the damper


(a) Ist (Hz)
(b) IInd (Hz)
(c) IIIrd (Hz)
(d) IVth (Hz)


Volume-II-Section-IV 9/17
Guaranteed Technical Particulars 10 161 kV Transmission line Project In Togo

15 The number of dampers required per span for


various span length
(a) Span lengths (mtrs) 250m 390m 400m
440m 1100m
(b) Nos. of dampers
i) Suspension span
ii) Tension span
16 Position of fixing damper on the earth wire from
the clamp mouth
(a) At tension points
i) First damper (mm)
ii) Second damper (mm)
iii) Third damper (mm)
(b) At suspension points
i) First damper (mm)
ii) Second damper, (mm)
iii) Third damper (mm)
17 Clamping torque (kg m)
18 Maximum possible dynamic strain on the earth
wire with recommended number of dampers

19 Minimum fatigue strength at amplitude of +/- 0.5


mm in nos. of cycles at
(a) Resonant frequency of Earth wire
(b) Highest frequency of vibration dampers
20 Clamp slipping strength of vibration damper
(a) Before fatigue test
(b) After fatigue test for 10 million cycles
21 Weight of zinc coating in (gms/m2 )
(a) Spring washers
(b) Bolts and nuts
(c) Weights
(d) Clamp
(e) Messenger cable
22 No. of dips of 1 minute duration which the damper
withstands under 'Preece Test'
(a) Spring washers
(b) Bolts and nuts
(c) Weights
(d) Clamp
(e) Messenger cable
23 Packing details
24 Certificate Marks (ISI/BS/or Any other International
Standard)
D) MIDSPAN COMPRESSION JOINT
1 Maker's name & address
2 Type
3 Inside diameter of sleeve before compression
4 Outside dimension of sleeve
a)Before compression (mm)
b)After compression (mm)
i. Corner to corner (mm)
ii. Surface to surface (mm)
5 Length of sleeve
a) Before compression (mm)
b) After compression (mm)
6 Weight of sleeve (kg)
7 Slipping strength of mid span (%)
joint, expressed as a percentage of
Ultimate tensile strength
8 Resistance of the compressed
Unit expressed as a percentage
of the Resistance of equivalent
length of bare earth wire
9 Material of sleeves
a)Material


Volume-II-Section-IV 10/17
Guaranteed Technical Particulars 11 161 kV Transmission line Project In Togo

b)Standard to which conform


c)Whether annealed properly
d)Brinnel Hardness of material
10 Galvanization
a)Process
b) Weight of zinc (g/sq. m)
c)No. of dips
i) one minute
ii) half minute
d)Quality of zinc and standard to which
conforming
11 Whether compression and non compression joints
marked on the sleeve (Y/N)
12 Breaking strength of Mid span joint as of the
breaking load of ground wire %
13 Details of die set for making joint
14 Whether suitable to pass through stringing block
when installed on ground wire during tension
stringing if not state the protective device needed
to make it suitable.
15 Capacity of Hydraulic compressor for making joint

16 Certification mark (ISI/BS/Any international


Institution
17 Drum no. and details and no. of components
18 Packing details

E) FLEXIBLE COPPER BONDS


1 Maker's name & address
2 Governing Standard
3 Material & Standard
4 No. of Strands
5 Length
6 Weight
7 Slipping strength of lugs provided on either end of
earthing bond without any damage to earthing
bond
8 Certification mark (ISI/BS/Any international
Institution
9 Packing details (No. of bonding pices per package
and gross weight)
V INSULATOR DISCS AND COMPLETE STRINGS

1 Type of insulator
2 Maker's name,address and country
3 Material and Governing standard
4 Detailed dimensional drawing indicating tolerances
for each type of insulator disc enclosed (YES/NO

5 Dimensions (Indicate tolerances also)


a) Diameter (mm)
i) Suspension
ii) Tension
b) Spacing (mm)
i) Suspension
ii) Tension
c) Creepage distance (mm)
i) Suspension
ii) Tension
6 Pin-ball-shank diameter (mm)
a) Suspension insulator
b) Tension insulator
7 Colour
a) Suspension


Volume-II-Section-IV 11/17
Guaranteed Technical Particulars 12 161 kV Transmission line Project In Togo

b) Tension

8 Electromechanical strength (KN)


a) Suspension
b) Tension
9 Mechanical breaking strength (KN)
a) Suspension
b) Tension
10 Power frequency one-minute withstandvoltage -KV
(rms)
a) Dry
i) Suspension
ii) Tension
b) Wet
i) Suspension
ii) Tension
11 Impulse 1.2x50 microsecond withstand voltage -KV
(peak)
a) +ve Wave
i) Suspension
ii) Tension
b) -ve Wave KV (peak)
i) Suspension
ii) Tension
12 Power frequency flashover voltage -KV (rms)
a) Dry
i) Suspension
ii) Tension
b) Wet KV (rms)
i) Suspension
ii) Tension
13 Impulse 1.2x50 microsecond flashover voltage KV
(peak)
a) +ve Wave
i) Suspension
ii) Tension
b) -ve Wave
i) Suspension
ii) Tension
14 Power frequency puncture voltage KV (rms)
a) Suspension
b) Tension
(ii) Corona extinction voltage KV (rms)
a) Suspension
b) Tension
15 RIV at 10 KV (rms)
a) Suspension (microvolts)
b) Tension (microvolts)
16 Weight of the Insulator disc (kg)
a) Suspension
b) Tension
17 Locking device
a) Type
i) Suspension
ii) Tension
b) Material
i) Suspension
ii) Tension
c) Standard to which conforming
18 Socket and ball ended component
a) Standard to which conforming
b) Material and Standard to which conforming

c) Galvanising process


Volume-II-Section-IV 12/17
Guaranteed Technical Particulars 13 161 kV Transmission line Project In Togo

d) Quality of zinc and Standard to which


conforming
e) Weight of zinc (g/m2 )
f) Number of one-minute dips
19 Packing details (No. of disc insulators of each type
per package and gross weight)
20 Certification mark (BIS/BS/Any National
Institution)
VII INSULATOR STRINGS
1 No. of insulator discs
a) Single suspension 'I'
b) Double suspension 'II'
c) Single Tension
d) Double Tension
2 E.M. Strength - KN
a) Single suspension
b) Double suspension
c) Single Tension
d) Double Tension
3 Power frequency one minute withstand voltage KV
(rms)
Dry/Wet
i) Suspension
1) Single
2) Double
ii) Tension
1) Single
2) Double
4 Power frequency flashover voltage KV (rms)
Dry/Wet
i) Suspension
1) Single
2) Double
ii) Tension
1) Single
2) Double
5 Impulse withstand voltage (dry) KV (peak)
Positive wave
i) Suspension
1) Single
2) Double
ii) Tension
1) Single
2) Double
Negative wave
i) Suspension
1) Single
2) Double
ii) Tension
1) Single
2) Double
6 Impulse flashover voltage (dry)
Positive wave - KV (peak)
i) Suspension
1) Single
2) Double
ii) Tension
1) Single
2) Double
Negative wave - KV (peak)
i) Suspension
1) Single
2) Double
ii) Tension
1) Single
2) Double


Volume-II-Section-IV 13/17