APPLICATION STANDARDS
The N2XCY cable is suitable for installation in ground, indoors, IEC 60502-1, VDE 0276-603, IS 1516.1
cable trunking and outdoors. Used for power distribution in
industrial application, including urban networks and household Flame retardant according to IEC 60332-1
feeders.
CHARACTERISTICS
Voltage Rating Uo/U
0.6/1kV
UKAS LABORATORY TESTED
This product is subject to the Quality Assurance protocols of The Cable Lab®,
a UKAS accredited ISO 17025 cable testing laboratory. Testing includes
Test Voltage
vertical flame, conductor resistance, tensile & elongation, and dimensional
3.5kV consistency, verified to published standards and approved product drawings.
Temperature Rating
Maximum Operating: +90ºC
Maximum Short-Circuit: +250°C
15 x overall diameter
REGULATORY COMPLIANCE
CONSTRUCTION This cable meets the requirements of the Low Voltage Directive 2014/35/EU
Conductor and the RoHS Directive 2011/65/EU. RoHS compliance has been tested and
confirmed by The Cable Lab® as meeting the requirements of the BSI RoHS
Class 2 Stranded copper Trusted KitemarkTM.
KM 634267
Filler
PVC (Polyvinyl chloride)
Concentric Conductor
Copper
Tape
Protective Copper Tape
Outer Sheath
PVC (Polyvinyl chloride)
Core Identification
2 core: Brown Blue
3 core: Green/Yellow Blue Brown
4 core: Green/Yellow Brown Black Grey
5 core: Green/Yellow Blue Brown Black Grey
7 core and above: Black Green/Yellow
DIMENSIONS
ELAND PART NO. NO. OF NOMINAL CROSS NOMINAL DIAMETER NOMINAL THICKNESS NOMINAL THICKNESS NOMINAL OVERALL NOMINAL
CORES SECTIONAL AREA OF CONDUCTOR OF INSULATION OF OUTER SHEATH DIAMETER WEIGHT
mm² mm mm mm mm kg/km
DIMENSIONS
ELAND PART NO. NO. OF NOMINAL CROSS NOMINAL DIAMETER NOMINAL THICKNESS NOMINAL THICKNESS NOMINAL OVERALL NOMINAL
CORES SECTIONAL AREA OF CONDUCTOR OF INSULATION OF OUTER SHEATH DIAMETER WEIGHT
mm² mm mm mm mm kg/km
CONDUCTORS
NOMINAL CROSS MINIMUM NO. OF WIRES IN CONDUCTOR MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC
SECTIONAL AREA ohms/km
mm2
Circular Circular Compacted Shaped Annealed Copper Conductor
Cu Al Cu Al Cu Al Plain Wires
1.5 7 - 6 - - - 12.1
2.5 7 - 6 - - - 7.41
4 7 - 6 - - - 4.61
6 7 - 6 - - - 3.08
10 7 7 6 6 - - 1.83
16 7 7 6 6 - - 1.15
25 7 7 6 6 6 6 0.727
35 7 7 6 6 6 6 0.524
50 19 19 6 6 6 6 0.387
70 19 19 12 12 12 12 0.268
95 19 19 15 15 15 15 0.193
120 37 37 18 15 18 15 0.153
150 37 37 18 15 18 15 0.124
185 37 37 30 30 30 30 0.0991
240 37 37 34 30 34 30 0.0754
300 61 61 34 30 34 30 0.0601
The above table is in accordance with BS EN 60228 (previously BS 6360)
ELECTRICAL CHARACTERISTICS
Current Carrying Capacity at 30°C
NOMINAL CROSS NO. OF CORES
SECTIONAL AREA
mm2
2, 3, 4 & 5 Core 7 Core 8 Core 10 Core 12 Core 14, 16 & 19 Core 21 & 24 Core
In ground In Air In ground In Air In ground In Air In ground In Air In ground In Air In ground In Air In ground In Air
A A A A A A A A A A A A A A
The information contained within this datasheet is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is
believed to be correct at the time of publication. When selecting cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances.