Sie sind auf Seite 1von 9

STORAGE CAPACITY OF RESERVOIR (OHSR-1)

(Draw off Pattern)


A:- Water Requirement at Mid stage = 2650.00 KL
B:- Average hourly demand 'a' = 2650/ 24 110.42 KL/Hr
C:- Peak factor = 3.0
D:- Peak hour demand = 3.0a
E:- Av. Pumping hour = 16 Hrs
F:- Average hourly input = 24/16=1.5 a =(24 hrs./av. Pumping hrs.)
Assume 16 Hrs electric supply ( 04:00 AM to 12:00 PM AND 16:00 PM to 24:AM ).
Storage Capacity of OHT has been calculated as below :

Cummulati
Total Rate of Total Cummulat Rate of Total Draw Difference
Hours ve Draw
hour Inflow Inflow ive inflow Draw off off Excess/Deficit
off
1 2 3 4 5 6 7 8 9
0.00-2.00 2.00 0.00 0.00 0.00 0.08 0.16 0.16 0.16
2.00-4.00 2.00 1.50 3.00 3.00 0.08 0.16 0.32 -2.68
4.00-5.00 1.00 1.50 1.50 4.50 0.20 0.20 0.52 -3.98
5.00-6.00 1.00 1.50 1.50 6.00 0.50 0.50 1.02 -4.98
6.00-8.00 2.00 1.50 3.00 9.00 3.00 6.00 7.02 -1.98
8.00-9.00 1.00 1.50 1.50 10.50 3.00 3.00 10.02 -0.48
9.00-10.00 1.00 1.50 1.50 12.00 2.00 2.00 12.02 0.02
10.00-12.00 2.00 0.00 0.00 12.00 1.00 2.00 14.02 2.02
12.00-13.30 1.50 0.00 0.00 12.00 1.00 1.50 15.52 3.52
13.30-14.00 0.50 0.00 0.00 12.00 0.25 0.13 15.65 3.65
14.00-14.30 0.50 1.50 0.75 12.75 0.25 0.13 15.77 3.02
14.30-15.30 1.00 1.50 1.50 14.25 0.24 0.24 16.01 1.76
15.30-16.00 0.50 1.50 0.75 15.00 1.00 0.50 16.51 1.51
16.00-16.30 0.50 1.50 0.75 15.75 1.00 0.50 17.01 1.26
16.30-17.00 0.50 1.50 0.75 16.50 2.00 1.00 18.01 1.51
17.00-18.00 1.00 1.50 1.50 18.00 2.00 2.00 20.01 2.01
18.00-19.00 1.00 1.50 1.50 19.50 2.00 2.00 22.01 2.51
19.00-20.30 1.50 1.50 2.25 21.75 1.00 1.50 23.51 1.76
20.30-21.00 0.50 1.50 0.75 22.50 0.50 0.25 23.76 1.26
21.00-22.00 1.00 1.50 1.50 24.00 0.08 0.08 23.84 -0.16
22.00-23.00 1.00 0.00 0.00 24.00 0.08 0.08 23.92 -0.08
23.00-24.00 1.00 0.00 0.00 24.00 0.08 0.08 24.00 0.00
Balancing Capacity of reservoir = max excess-max. deficit
Balancing Capacity of reservoir = 3.645 (-) -4.98 xa
= 8.625 x a
= 952.34 KL
Adopted 950.00 KL
STORAGE CAPACITY OF RESERVOIR (OHSR-2)

(Draw off Pattern)


A:- Water Requirement at Mid stage = 1525.56 KL
B:- Average hourly demand 'a' =1525.556/ 24 63.56 KL/Hr
C:- Peak factor = 3.0
D:- Peak hour demand = 3.0a
E:- Av. Pumping hour = 16 Hrs
F:- Average hourly input = 24/16=1.5 a =(24 hrs./av. Pumping hrs.)
Assume 16 Hrs electric supply ( 04:00 AM to 12:00 PM AND 16:00 PM to 24:AM ).
Storage Capacity of OHT has been calculated as below :

Cummulati
Total Rate of Total Cummulat Rate of Total Draw Difference
Hours ve Draw
hour Inflow Inflow ive inflow Draw off off Excess/Deficit
off
1 2 3 4 5 6 7 8 9
0.00-2.00 2.00 0.00 0.00 0.00 0.08 0.16 0.16 0.16
2.00-4.00 2.00 1.50 3.00 3.00 0.08 0.16 0.32 -2.68
4.00-5.00 1.00 1.50 1.50 4.50 0.20 0.20 0.52 -3.98
5.00-6.00 1.00 1.50 1.50 6.00 0.50 0.50 1.02 -4.98
6.00-8.00 2.00 1.50 3.00 9.00 3.00 6.00 7.02 -1.98
8.00-9.00 1.00 1.50 1.50 10.50 3.00 3.00 10.02 -0.48
9.00-10.00 1.00 1.50 1.50 12.00 2.00 2.00 12.02 0.02
10.00-12.00 2.00 0.00 0.00 12.00 1.00 2.00 14.02 2.02
12.00-13.30 1.50 0.00 0.00 12.00 1.00 1.50 15.52 3.52
13.30-14.00 0.50 0.00 0.00 12.00 0.25 0.13 15.65 3.65
14.00-14.30 0.50 1.50 0.75 12.75 0.25 0.13 15.77 3.02
14.30-15.30 1.00 1.50 1.50 14.25 0.24 0.24 16.01 1.76
15.30-16.00 0.50 1.50 0.75 15.00 1.00 0.50 16.51 1.51
16.00-16.30 0.50 1.50 0.75 15.75 1.00 0.50 17.01 1.26
16.30-17.00 0.50 1.50 0.75 16.50 2.00 1.00 18.01 1.51
17.00-18.00 1.00 1.50 1.50 18.00 2.00 2.00 20.01 2.01
18.00-19.00 1.00 1.50 1.50 19.50 2.00 2.00 22.01 2.51
19.00-20.30 1.50 1.50 2.25 21.75 1.00 1.50 23.51 1.76
20.30-21.00 0.50 1.50 0.75 22.50 0.50 0.25 23.76 1.26
21.00-22.00 1.00 1.50 1.50 24.00 0.08 0.08 23.84 -0.16
22.00-23.00 1.00 0.00 0.00 24.00 0.08 0.08 23.92 -0.08
23.00-24.00 1.00 0.00 0.00 24.00 0.08 0.08 24.00 0.00
Balancing Capacity of reservoir = max excess-max. deficit
Balancing Capacity of reservoir = 3.645 (-) -4.98 xa
= 8.625 x a
= 548.25 KL
Adopted 550.00 KL
STORAGE CAPACITY OF RESERVOIR (OHSR-3)

(Draw off Pattern)


A:- Water Requirement at Mid stage = 687.15 KL
B:- Average hourly demand 'a' = 687.15/ 24 28.63 KL/Hr
C:- Peak factor = 3.0
D:- Peak hour demand = 3.0a
E:- Av. Pumping hour = 16 Hrs
F:- Average hourly input = 24/16=1.5 a =(24 hrs./av. Pumping hrs.)
Assume 16 Hrs electric supply ( 04:00 AM to 12:00 PM AND 16:00 PM to 24:AM ).
Storage Capacity of OHT has been calculated as below :

Cummulati
Total Rate of Total Cummulat Rate of Total Draw Difference
Hours ve Draw
hour Inflow Inflow ive inflow Draw off off Excess/Deficit
off
1 2 3 4 5 6 7 8 9
0.00-2.00 2.00 0.00 0.00 0.00 0.08 0.16 0.16 0.16
2.00-4.00 2.00 1.50 3.00 3.00 0.08 0.16 0.32 -2.68
4.00-5.00 1.00 1.50 1.50 4.50 0.20 0.20 0.52 -3.98
5.00-6.00 1.00 1.50 1.50 6.00 0.50 0.50 1.02 -4.98
6.00-8.00 2.00 1.50 3.00 9.00 3.00 6.00 7.02 -1.98
8.00-9.00 1.00 1.50 1.50 10.50 3.00 3.00 10.02 -0.48
9.00-10.00 1.00 1.50 1.50 12.00 2.00 2.00 12.02 0.02
10.00-12.00 2.00 0.00 0.00 12.00 1.00 2.00 14.02 2.02
12.00-13.30 1.50 0.00 0.00 12.00 1.00 1.50 15.52 3.52
13.30-14.00 0.50 0.00 0.00 12.00 0.25 0.13 15.65 3.65
14.00-14.30 0.50 1.50 0.75 12.75 0.25 0.13 15.77 3.02
14.30-15.30 1.00 1.50 1.50 14.25 0.24 0.24 16.01 1.76
15.30-16.00 0.50 1.50 0.75 15.00 1.00 0.50 16.51 1.51
16.00-16.30 0.50 1.50 0.75 15.75 1.00 0.50 17.01 1.26
16.30-17.00 0.50 1.50 0.75 16.50 2.00 1.00 18.01 1.51
17.00-18.00 1.00 1.50 1.50 18.00 2.00 2.00 20.01 2.01
18.00-19.00 1.00 1.50 1.50 19.50 2.00 2.00 22.01 2.51
19.00-20.30 1.50 1.50 2.25 21.75 1.00 1.50 23.51 1.76
20.30-21.00 0.50 1.50 0.75 22.50 0.50 0.25 23.76 1.26
21.00-22.00 1.00 1.50 1.50 24.00 0.08 0.08 23.84 -0.16
22.00-23.00 1.00 0.00 0.00 24.00 0.08 0.08 23.92 -0.08
23.00-24.00 1.00 0.00 0.00 24.00 0.08 0.08 24.00 0.00
Balancing Capacity of reservoir = max excess-max. deficit
Balancing Capacity of reservoir = 3.645 (-) -4.98 xa
= 8.625 x a
= 246.94 KL
Adopted 250.00 KL
STORAGE CAPACITY OF RESERVOIR (OHSR-4)

(Draw off Pattern)


A:- Water Requirement at Mid stage = 347.92 KL
B:- Average hourly demand 'a' = 347.92/ 24 14.50 KL/Hr
C:- Peak factor = 3.0
D:- Peak hour demand = 3.0a
E:- Av. Pumping hour = 16 Hrs
F:- Average hourly input = 24/16=1.5 a =(24 hrs./av. Pumping hrs.)
Assume 16 Hrs electric supply ( 04:00 AM to 12:00 PM AND 16:00 PM to 24:AM ).
Storage Capacity of OHT has been calculated as below :

Cummulati
Total Rate of Total Cummulat Rate of Total Draw Difference
Hours ve Draw
hour Inflow Inflow ive inflow Draw off off Excess/Deficit
off
1 2 3 4 5 6 7 8 9
0.00-2.00 2.00 0.00 0.00 0.00 0.08 0.16 0.16 0.16
2.00-4.00 2.00 1.50 3.00 3.00 0.08 0.16 0.32 -2.68
4.00-5.00 1.00 1.50 1.50 4.50 0.20 0.20 0.52 -3.98
5.00-6.00 1.00 1.50 1.50 6.00 0.50 0.50 1.02 -4.98
6.00-8.00 2.00 1.50 3.00 9.00 3.00 6.00 7.02 -1.98
8.00-9.00 1.00 1.50 1.50 10.50 3.00 3.00 10.02 -0.48
9.00-10.00 1.00 1.50 1.50 12.00 2.00 2.00 12.02 0.02
10.00-12.00 2.00 0.00 0.00 12.00 1.00 2.00 14.02 2.02
12.00-13.30 1.50 0.00 0.00 12.00 1.00 1.50 15.52 3.52
13.30-14.00 0.50 0.00 0.00 12.00 0.25 0.13 15.65 3.65
14.00-14.30 0.50 1.50 0.75 12.75 0.25 0.13 15.77 3.02
14.30-15.30 1.00 1.50 1.50 14.25 0.24 0.24 16.01 1.76
15.30-16.00 0.50 1.50 0.75 15.00 1.00 0.50 16.51 1.51
16.00-16.30 0.50 1.50 0.75 15.75 1.00 0.50 17.01 1.26
16.30-17.00 0.50 1.50 0.75 16.50 2.00 1.00 18.01 1.51
17.00-18.00 1.00 1.50 1.50 18.00 2.00 2.00 20.01 2.01
18.00-19.00 1.00 1.50 1.50 19.50 2.00 2.00 22.01 2.51
19.00-20.30 1.50 1.50 2.25 21.75 1.00 1.50 23.51 1.76
20.30-21.00 0.50 1.50 0.75 22.50 0.50 0.25 23.76 1.26
21.00-22.00 1.00 1.50 1.50 24.00 0.08 0.08 23.84 -0.16
22.00-23.00 1.00 0.00 0.00 24.00 0.08 0.08 23.92 -0.08
23.00-24.00 1.00 0.00 0.00 24.00 0.08 0.08 24.00 0.00
Balancing Capacity of reservoir = max excess-max. deficit
Balancing Capacity of reservoir = 3.645 (-) -4.98 xa
= 8.625 x a
= 125.03 KL
Adopted 150.00 KL
STORAGE CAPACITY OF RESERVOIR (OHSR-5)

(Draw off Pattern)


A:- Water Requirement at Mid stage = 155.53 KL
B:- Average hourly demand 'a' = 155.53/ 24 6.48 KL/Hr
C:- Peak factor = 3.0
D:- Peak hour demand = 3.0a
E:- Av. Pumping hour = 16 Hrs
F:- Average hourly input = 24/16=1.5 a =(24 hrs./av. Pumping hrs.)
Assume 16 Hrs electric supply ( 04:00 AM to 12:00 PM AND 16:00 PM to 24:AM ).
Storage Capacity of OHT has been calculated as below :

Cummulati
Total Rate of Total Cummulat Rate of Total Draw Difference
Hours ve Draw
hour Inflow Inflow ive inflow Draw off off Excess/Deficit
off
1 2 3 4 5 6 7 8 9
0.00-2.00 2.00 0.00 0.00 0.00 0.08 0.16 0.16 0.16
2.00-4.00 2.00 1.50 3.00 3.00 0.08 0.16 0.32 -2.68
4.00-5.00 1.00 1.50 1.50 4.50 0.20 0.20 0.52 -3.98
5.00-6.00 1.00 1.50 1.50 6.00 0.50 0.50 1.02 -4.98
6.00-8.00 2.00 1.50 3.00 9.00 3.00 6.00 7.02 -1.98
8.00-9.00 1.00 1.50 1.50 10.50 3.00 3.00 10.02 -0.48
9.00-10.00 1.00 1.50 1.50 12.00 2.00 2.00 12.02 0.02
10.00-12.00 2.00 0.00 0.00 12.00 1.00 2.00 14.02 2.02
12.00-13.30 1.50 0.00 0.00 12.00 1.00 1.50 15.52 3.52
13.30-14.00 0.50 0.00 0.00 12.00 0.25 0.13 15.65 3.65
14.00-14.30 0.50 1.50 0.75 12.75 0.25 0.13 15.77 3.02
14.30-15.30 1.00 1.50 1.50 14.25 0.24 0.24 16.01 1.76
15.30-16.00 0.50 1.50 0.75 15.00 1.00 0.50 16.51 1.51
16.00-16.30 0.50 1.50 0.75 15.75 1.00 0.50 17.01 1.26
16.30-17.00 0.50 1.50 0.75 16.50 2.00 1.00 18.01 1.51
17.00-18.00 1.00 1.50 1.50 18.00 2.00 2.00 20.01 2.01
18.00-19.00 1.00 1.50 1.50 19.50 2.00 2.00 22.01 2.51
19.00-20.30 1.50 1.50 2.25 21.75 1.00 1.50 23.51 1.76
20.30-21.00 0.50 1.50 0.75 22.50 0.50 0.25 23.76 1.26
21.00-22.00 1.00 1.50 1.50 24.00 0.08 0.08 23.84 -0.16
22.00-23.00 1.00 0.00 0.00 24.00 0.08 0.08 23.92 -0.08
23.00-24.00 1.00 0.00 0.00 24.00 0.08 0.08 24.00 0.00
Balancing Capacity of reservoir = max excess-max. deficit
Balancing Capacity of reservoir = 3.645 (-) -4.98 xa
= 8.625 x a
= 55.89 KL
Adopted 60.00 KL
STORAGE CAPACITY OF RESERVOIR (OHSR-6)

(Draw off Pattern)


A:- Water Requirement at Mid stage = 3124.40 KL
B:- Average hourly demand 'a' = 3124.4/24 130.18 KL/Hr
C:- Peak factor = 3.0
D:- Peak hour demand = 3.0a
E:- Av. Pumping hour = 16 Hrs
F:- Average hourly input = 24/16=1.5 a =(24 hrs./av. Pumping hrs.)
Assume 16 Hrs electric supply ( 04:00 AM to 12:00 PM AND 16:00 PM to 24:AM ).
Storage Capacity of OHT has been calculated as below :

Cummulati
Total Rate of Total Cummulat Rate of Total Draw Difference
Hours ve Draw
hour Inflow Inflow ive inflow Draw off off Excess/Deficit
off
1 2 3 4 5 6 7 8 9
0.00-2.00 2.00 0.00 0.00 0.00 0.08 0.16 0.16 0.16
2.00-4.00 2.00 1.50 3.00 3.00 0.08 0.16 0.32 -2.68
4.00-5.00 1.00 1.50 1.50 4.50 0.20 0.20 0.52 -3.98
5.00-6.00 1.00 1.50 1.50 6.00 0.50 0.50 1.02 -4.98
6.00-8.00 2.00 1.50 3.00 9.00 3.00 6.00 7.02 -1.98
8.00-9.00 1.00 1.50 1.50 10.50 3.00 3.00 10.02 -0.48
9.00-10.00 1.00 1.50 1.50 12.00 2.00 2.00 12.02 0.02
10.00-12.00 2.00 0.00 0.00 12.00 1.00 2.00 14.02 2.02
12.00-13.30 1.50 0.00 0.00 12.00 1.00 1.50 15.52 3.52
13.30-14.00 0.50 0.00 0.00 12.00 0.25 0.13 15.65 3.65
14.00-14.30 0.50 1.50 0.75 12.75 0.25 0.13 15.77 3.02
14.30-15.30 1.00 1.50 1.50 14.25 0.24 0.24 16.01 1.76
15.30-16.00 0.50 1.50 0.75 15.00 1.00 0.50 16.51 1.51
16.00-16.30 0.50 1.50 0.75 15.75 1.00 0.50 17.01 1.26
16.30-17.00 0.50 1.50 0.75 16.50 2.00 1.00 18.01 1.51
17.00-18.00 1.00 1.50 1.50 18.00 2.00 2.00 20.01 2.01
18.00-19.00 1.00 1.50 1.50 19.50 2.00 2.00 22.01 2.51
19.00-20.30 1.50 1.50 2.25 21.75 1.00 1.50 23.51 1.76
20.30-21.00 0.50 1.50 0.75 22.50 0.50 0.25 23.76 1.26
21.00-22.00 1.00 1.50 1.50 24.00 0.08 0.08 23.84 -0.16
22.00-23.00 1.00 0.00 0.00 24.00 0.08 0.08 23.92 -0.08
23.00-24.00 1.00 0.00 0.00 24.00 0.08 0.08 24.00 0.00
Balancing Capacity of reservoir = max excess-max. deficit
Balancing Capacity of reservoir = 3.645 (-) -4.98 xa
= 8.625 x a
= 1122.83 KL
Adopted 1150.00 KL
STORAGE CAPACITY OF RESERVOIR (ZONE- 2)

(Draw off Pattern)


A:- Water Requirement at Mid stage = 563.00 KL
B:- Average hourly demand 'a' = 563/ 24 23.46 KL/Hr
C:- Peak factor = 3.0
D:- Peak hour demand = 3.0a
E:- Av. Pumping hour = 16 Hrs
F:- Average hourly input = 24/16=1.5 a =(24 hrs./av. Pumping hrs.)
Assume 16 Hrs electric supply ( 04:00 AM to 12:00 PM AND 16:00 PM to 24:AM ).
Storage Capacity of OHT has been calculated as below :

Cummulati
Total Rate of Total Cummulat Rate of Total Draw Difference
Hours ve Draw
hour Inflow Inflow ive inflow Draw off off Excess/Deficit
off
1 2 3 4 5 6 7 8 9
0.00-2.00 2.00 0.00 0.00 0.00 0.08 0.16 0.16 0.16
2.00-4.00 2.00 1.50 3.00 3.00 0.08 0.16 0.32 -2.68
4.00-5.00 1.00 1.50 1.50 4.50 0.20 0.20 0.52 -3.98
5.00-6.00 1.00 1.50 1.50 6.00 0.50 0.50 1.02 -4.98
6.00-8.00 2.00 1.50 3.00 9.00 3.00 6.00 7.02 -1.98
8.00-9.00 1.00 1.50 1.50 10.50 3.00 3.00 10.02 -0.48
9.00-10.00 1.00 1.50 1.50 12.00 2.00 2.00 12.02 0.02
10.00-12.00 2.00 0.00 0.00 12.00 1.00 2.00 14.02 2.02
12.00-13.30 1.50 0.00 0.00 12.00 1.00 1.50 15.52 3.52
13.30-14.00 0.50 0.00 0.00 12.00 0.25 0.13 15.65 3.65
14.00-14.30 0.50 1.50 0.75 12.75 0.25 0.13 15.77 3.02
14.30-15.30 1.00 1.50 1.50 14.25 0.24 0.24 16.01 1.76
15.30-16.00 0.50 1.50 0.75 15.00 1.00 0.50 16.51 1.51
16.00-16.30 0.50 1.50 0.75 15.75 1.00 0.50 17.01 1.26
16.30-17.00 0.50 1.50 0.75 16.50 2.00 1.00 18.01 1.51
17.00-18.00 1.00 1.50 1.50 18.00 2.00 2.00 20.01 2.01
18.00-19.00 1.00 1.50 1.50 19.50 2.00 2.00 22.01 2.51
19.00-20.30 1.50 1.50 2.25 21.75 1.00 1.50 23.51 1.76
20.30-21.00 0.50 1.50 0.75 22.50 0.50 0.25 23.76 1.26
21.00-22.00 1.00 1.50 1.50 24.00 0.08 0.08 23.84 -0.16
22.00-23.00 1.00 0.00 0.00 24.00 0.08 0.08 23.92 -0.08
23.00-24.00 1.00 0.00 0.00 24.00 0.08 0.08 24.00 0.00
Balancing Capacity of reservoir = max excess-max. deficit
Balancing Capacity of reservoir = 3.645 (-) -4.98 xa
= 8.625 x a
= 202.33 KL
Adopted 200.00 KL
STORAGE CAPACITY OF RESERVOIR

(Draw off Pattern)


A:- Water Requirement at mid stage = 580.00 KL
B:- Average hourly demand 'a' = 580/ 24 24.17
C:- Peak factor = 3
D:- Av. Pumping hour = 8 Hrs
E:- Average hourly input (24 hrs.x a / av.
Pumping hrs.) = 24/8xa =3 a
Total Rate of Total Cummulative Total Draw Cummulative
Hours Rate of Draw off
hour Inflow Inflow inflow off Draw off

1 2 3 4 5 6 7 8
0.00-4.00 4.00 0a 0a 0a 0.08 a 0.32 a 0.32
4.00-5.00 1.00 3a 3a 3a 0.2 a 0.2 a 0.52
5.00-6.00 1.00 3a 3a 6a 0.5 a 0.5 a 1.02
6.00-8.00 2.00 3a 6a 12 a 3a 6a 7.02
8.00-9.00 1.00 0a 0a 12 a 3a 3a 10.02
9.00-10.00 1.00 0a 0a 12 a 2a 2a 12.02
10.00-12.00 2.00 0a 0a 12 a 1a 2a 14.02
12.00-13.30 1.50 0a 0a 12 a 1a 1.5 a 15.52
13.30-14.30 1.00 0a 0a 12 a 0.25 a 0.25 a 15.77
14.30-15.30 1.00 0a 0a 12 a 0.24 a 0.24 a 16.01
15.30-16.00 0.50 0a 0a 12 a 1a 0.5 a 16.51
16.00-16.30 0.50 0a 0a 12 a 1a 0.5 a 17.01
16.30-17.00 0.50 0a 0a 12 a 2a 1a 18.01
17.00-18.00 1.00 3a 3a 15 a 2a 2a 20.01
18.00-19.00 1.00 3a 3a 18 a 2a 2a 22.01
19.00-20.30 1.50 3a 4.5 a 22.5 a 1a 1.5 a 23.51
20.30-21.00 0.50 3a 1.5 a 24 a 0.5 a 0.25 a 23.76
21.00-22.00 1.00 0a 0a 24 a 0.08 a 0.08 a 23.84
22.00-23.00 1.00 0a 0a 24 a 0.08 a 0.08 a 23.92
23.00-24.00 1.00 0a 0a 24 a 0.08 a 0.08 a 24
Balancing Capacity of reservoir = max excess-max. deficit
Balancing Capacity of reservoir = 6.01 (-) -4.98 xa
= 10.99 xa
= 265.59 KL
Adopted 250.00 KL
KL/Hr

Cummulative Difference
Draw off Excess/Deficit

8 9
a 0.32 a
a -2.48 a
a -4.98 a
a -4.98 a
a -1.98 a
a 0.02 a
a 2.02 a
a 3.52 a
a 3.77 a
a 4.01 a
a 4.51 a
a 5.01 a
a 6.01 a
a 5.01 a
a 4.01 a
a 1.01 a
a -0.24 a
a -0.16 a
a -0.08 a
a 0a