Biomed eService Report Biomedical Engineering

St. Lukes Medical Center Clinical Engineering Department


Quezon City Page 1 of 6
Anesthesia Machine
(Pre-use Checklist)
Unit: OPTHA-OR Room#: 1 Date: November 28 2019
Brand / Model / Serial #: GE/CARESTATION 650

QUALITATIVE TEST
No. Pass Fail Description No. Pass Fail Description
1.1 ✔ Chassis / Housing 1.11 ✔ Filters
1.2 Mount / Fasteners 1.12 ✔ Controls / Switches
1.3 ✔ Casters / Brakes 1.13 ✔ Indicators / Displays
1.4 ✔ AC Plug / Receptacles 1.14 ✔ Self Test
1.5 ✔ Line Cord 1.15 ✔ Time/Date Settings
1.6 ✔ Strain Reliefs 1.16 ✔ Labeling
1.7 Circuit Breakers / Fuses 1.17 ✔ Flowmeters
1.8 ✔ Tubes / Hoses 1.18 Gas Cylinder
1.9 ✔ Cables 1.19 Humidifier
1.10 Fittings / Connectors 1.20 Accessories

PRE-OPERATIONAL TEST
No. Pass Fail Description No. Pass Fail Description
2.1 ✔ Alarm System 2.6 ✔ Funtion Test/ Leak Test
APL Valve Test & Pressure Relief
2.2 ✔ Audible Signals 2.7 ✔ Test
Inspiratory & Expiratory Non-
2.3 ✔ Back-up Battery Test 2.8 ✔ return Valve Test

2.4 ✔ Ventilator Internal Test 2.9 ✔ Bag / Ventilator Switch Test


Leak Test Absorber Canister
2.5 ✔ Oxygen Flush Valve 2.10
Detached

PREVENTIVE MAINTENANCE
No. Pass Fail Description No. Pass Fail Description
3.1 Calibration of Spirometery 3.3 ✔ Condensate Drainage

3.2 Calibration of Oxygen Monitor 3.4 Cleaned Unit

Comments/Remarks:
Ongoing

biomed eampc2014 ver1.0


Biomed eService Report Biomedical Engineering
St. Lukes Medical Center Clinical Engineering Department
Quezon City Page 2 of 6
Operative Cluster
(Equipment Checklist)

Unit: OPTHA-OR Room# : 1

STANDARD MACHINES AND EQUIPMENT FOUND INSIDE THE OR THEATER


Power on Self test
NO. Description Brand / Model / Serial# Remarks
Passed Failed
1 Anesthesia Machine GE/CARESTATION 650 ✔ W/ scav no bag hose
2 Capnometer ( AGM ) DE483B8534
3 Cautery Machine
Penlon/d0710-0823 ✔
4 Gas Vaporizers

✔ Berchtold 11682
5 OR Lights
Berchtold ✔
6 OR Table DEXTA / E062300-7 ✔ Eye Force 3478

7 Patient Monitor (Cables) CRITICARE POET PLUS/108237855 ✔ DE483B8534


SPECIAL EQUIPMENT FOUND INSIDE THE OR THEATER AS ENDORSED/RESERVED BY THE SURGEON
Power on Self test
NO. Description Brand/Model/Serial# Remarks
Passed Failed
1
2

biomed eampc2014 ver1.0


ineering Biomed eService Report Biomedical Engineering
partment St. Lukes Medical Center Clinical Engineering Department
Quezon City Page 3 of 6
Anesthesia Machine
(Pre-use Checklist)
Unit: OPTHA-OR Room#: 2
Brand / Model / Serial #: OHMEDA/AESTIVA/AMVJ0312

QUALITATIVE TEST
No. Pass Fail Description No. Pass Fail Description
1.1 ✔ Chassis / Housing 1.11 ✔ Filters
1.2 Mount / Fasteners 1.12
✔ Controls / Switches
1.3 ✔ Casters / Brakes 1.13 ✔ Indicators / Displays
1.4 ✔ AC Plug / Receptacles 1.14 ✔ Self Test
1.5 ✔ Line Cord 1.15 Time/Date Settings
1.6 ✔ Strain Reliefs 1.16 ✔ Labeling
1.7 Circuit Breakers / Fuses 1.17 ✔ Flowmeters
1.8 ✔ Tubes / Hoses 1.18 ✔ Gas Cylinder
1.9 ✔ Cables 1.19 Humidifier
1.10 Fittings / Connectors 1.20 Accessories

PRE-OPERATIONAL TEST
No. Pass Fail Description No. Pass Fail Description
2.1 ✔ Alarm System 2.6 ✔ Funtion Test/ Leak Test
APL Valve Test & Pressure Relief
2.2 ✔ Audible Signals 2.7 ✔ Test
Inspiratory & Expiratory Non-
2.3 ✔ Back-up Battery Test 2.8 ✔ return Valve Test
2.4 ✔ Ventilator Internal Test 2.9 ✔ Bag / Ventilator Switch Test
Leak Test Absorber Canister
2.5 ✔ Oxygen Flush Valve 2.10
Detached

PREVENTIVE MAINTENANCE
No. Pass Fail Description No. Pass Fail Description
3.1 Calibration of Spirometery 3.3 ✔ Condensate Drainage

3.2 Calibration of Oxygen Monitor 3.4 Cleaned Unit

Comments/Remarks:
Performed pre-use procedure in accordance to manufacturer's recommendation. Unit passed and ready to use.

biomed eampc2014 ver1.0


ineering Biomed eService Report Biomedical Engineering
partment St. Lukes Medical Center Clinical Engineering Department
Quezon City Page 4 of 6
Operative Cluster
(Equipment Checklist)

Unit: OPTHA-OR Room# : 2

STANDARD MACHINES AND EQUIPMENT FOUND INSIDE THE OR THEATER


Power on Self test
NO. Description Brand / Model / Serial# Remarks
Passed Failed
1 Anesthesia Machine OHMEDA/AESTIVA/AMVJ0312 ✔ Amvh00284 W/ scav
2 Capnometer ( AGM ) CRITICARE POET IQ/308034712 ✔ Philips ashe0004
3 Cautery Machine
Penlon/DO3090187 ✔ BEJS05740
4 Gas Vaporizers

BERCHTOLD / D530 / 11684 ✔


5 OR Lights
BERCHTOLD / D650 / 11935 ✔
6 OR Table DEXTA / E062300-7 ✔ Eyeforce 4890
7 Patient Monitor (Cables) CRITICARE POET PLUS/308241094 ✔
SPECIAL EQUIPMENT FOUND INSIDE THE OR THEATER AS ENDORSED/RESERVED BY THE SURGEON
Power on Self test
NO. Description Brand/Model/Serial# Remarks
Passed Failed
1
2

biomed eampc2014 ver1.0


ineering Biomed eService Report Biomedical Engineering
partment St. Lukes Medical Center Clinical Engineering Department
Quezon City Page 5 of 6
Anesthesia Machine
(Pre-use Checklist)
Unit: OPTHA-OR Room#: 3
Brand / Model / Serial #: Ohmeda/Aestiva/AMVJ00312
QUALITATIVE TEST
No. Pass Fail Description No. Pass Fail Description
1.1 ✔ Chassis / Housing 1.11 ✔ Filters
1.2 Mount / Fasteners 1.12 ✔ Controls / Switches
1.3 ✔ Casters / Brakes 1.13 ✔ Indicators / Displays
1.4 ✔ AC Plug / Receptacles 1.14 ✔ Self Test
1.5 ✔ Line Cord 1.15 Time/Date Settings
1.6 ✔ Strain Reliefs 1.16 ✔ Labeling
1.7 Circuit Breakers / Fuses 1.17 ✔ Flowmeters
1.8 ✔ Tubes / Hoses 1.18 ✔ Gas Cylinder
1.9 ✔ Cables 1.19 Humidifier
1.10 Fittings / Connectors 1.20 Accessories

PRE-OPERATIONAL TEST
No. Pass Fail Description No. Pass Fail Description
2.1 ✔ Alarm System 2.6 ✔ Funtion Test/ Leak Test
APL Valve Test & Pressure Relief
2.2 ✔ Audible Signals 2.7 ✔ Test
Inspiratory & Expiratory Non-
2.3 ✔ Back-up Battery Test 2.8 ✔ return Valve Test
2.4 ✔ Ventilator Internal Test 2.9 ✔ Bag / Ventilator Switch Test
Leak Test Absorber Canister
2.5 ✔ Oxygen Flush Valve 2.10
Detached

PREVENTIVE MAINTENANCE
No. Pass Fail Description No. Pass Fail Description
3.1 Calibration of Spirometery 3.3 ✔ Condensate Drainage

3.2 Calibration of Oxygen Monitor 3.4 Cleaned Unit

Comments/Remarks:
Performed pre-use procedure in accordance to manufacturer's recommendation. Unit passed
and ready to use.no wagd hose

biomed eampc2014 ver1.0


ineering Biomed eService Report Biomedical Engineering
partment St. Lukes Medical Center Clinical Engineering Department
Quezon City Page 6 of 6
Operative Cluster
(Equipment Checklist)

Unit: OPTHA-OR Room# : 3

STANDARD MACHINES AND EQUIPMENT FOUND INSIDE THE OR THEATER


Power on Self test
NO. Description Brand / Model / Serial# Remarks
Passed Failed
1 Anesthesia Machine Ohmeda/Aestiva/AMVJ00312 ✔
2 Capnometer ( AGM ) CRITICARE POET IQ/308034718 ✔ Philips/ashe-0004
3 Cautery Machine
Penlon/d0710-0823 ✔
4 Gas Vaporizers

berchtold/6010040-j 11685 ✔
5 OR Lights
berchtold/5910040-J 11938 ✔
6 OR Table DEXTA / E062300-7 ✔ Brumba
7 Patient Monitor (Cables) CRITICARE POET PLUS/308241094 ✔ Philips/DE483B8442
SPECIAL EQUIPMENT FOUND INSIDE THE OR THEATER AS ENDORSED/RESERVED BY THE SURGEON
Power on Self test
NO. Description Brand/Model/Serial# Remarks
Passed Failed
1
2

Time Performed by: Acknowledged by:


Start: 9 30 PM
Completed: 9 50 PM E. Basilio/ Lalaine F. Edu

biomed eampc2014 ver1.0