Battens & special purpose

Battens are the simple, inexpensive lighting


solution for applications where aesthetics and
luminance control are not critical.
Battens
Battens Pentura TMS 122 Pentura TMS 122

Technical Data
Type For Lamp Nominal Mains Current Nominal
Voltage (V) (A) Power Factor
General Description
Functional and economical general purpose batten for 1 x 'TL'5
fluorescent lamp with aluminium symmetric reflector for surface TMS122/128 HF 1 x TL5 28 W 240 0.12 0.98
mounting on the wall or ceiling. TMS122/228 HF 2 x TL5 28 W 240 0.23 0.98
TMS122/128 E HF 1 x TL5 28 W 240 0.12 0.98
Features
! Sleek dimensions (37 mm width) TMS122/228 E HF 2 x TL5 28 W 240 0.23 0.98
TMS 122 ! Coupled with 'TL'5 lamp & high frequency ballast, the luminaire is TMS122/254 EBP 2 x TL5 54 W 240 0.45 0.98
one of the most efficient systems.
! Housing made of CRCA sheet steel, powder coated & is spared of
any weld spots. Ordering Data
! Optional imported anodised glossy reflector can be used for
effective light distribution.
Type Ordering No Quantity Dimensions Gross Weight Volume
Applications per box (mm) (kg) (m3)
! Small offices
! Conference rooms TMS122/128 HF 1301 01645 6 1240 x 145 x 150 6.25 0.027
! Reception & public service areas TMS122/228 HF 1301 01665 6 1240 x 145 x 150 6.25 0.027
! Recreational areas (restaurants, cafeteria) TMS122/128 E HF 1301 01675 6 1240 x 145 x 150 6.25 0.027
! Shops
TMS 122/228 TMS 122/228 TMS122/228 E HF 1350 15965 6 1240 x 145 x 150 6.25 0.027
! Boutiques
with GMS 122/228 R ! Textile Mills TMS122/254 EBP 1300 23995 6 1240 x 145 x 150 7.00 0.027
GMS122/128 R 1308 24425 6 1200 x 120 x 70 2.00 0.01
Installation GMS122/228 R* 1308 24435 6 1200 x 120 x 70 2.00 0.01
! Mounting electrical connection through cable entry centrally *This reflector can be used with TMS 122/254 luminaire also
Method : base plate (with electrical components) fixed to the
ceiling via holes for (wood) screws. White pre-lacquered cover
(decorative) fixed with 2 screws (supplied) to the base plate.

Compliances
! IP 20

Dimensions (mm) IP 20

Pentura TMS 122/128


1080

1171

37

TMS 122 / 228

37
69

1178

73
TMS 122 / 228
with GMS 122 REFLECTOR
37
69

75
40

1178

1133 73
107

112

Battens

90 91
Battens
Battens TMC 501 Series TMC 501 Series

Technical Data

Type For Lamp Nominal Mains Current Nominal


Voltage (V) (A) Power Factor
General Description
Functional and decorative general purpose basic battens for ‘TL’/
‘TL’D fluorescent lamp. For surface mounting on the wall or ceiling. TMC 501/136 HPF 1 x 'TLD 36W / 'TL' 40 W 240 0.23 0.90
TMC 501/236 HPF 2 x 'TLD' 36 W / 'TL' 40 W 240 0.46 0.90
Features TMC 501/136 HF 1 x 'TLD' 36 W / 'TL' 40W 240 0.16 0.95
TMC 501 / 236 ! The channel has a single piece construction made of powder
coated white CRCA sheet steel, eliminating spot welds & hence TMC 501/236 HF 2 x 'TLD' 36W / 'TL' 40 W 240 0.30 0.95
rust free TKC 203/136 HPF 1 x 'TLD 36W / 'TL' 40 W 240 0.23 0.90
! The aesthetically designed lampholder brackets are side-in-type TKC 203/236 HPF 2 x 'TLD' 36W / 'TL' 40 W 240 0.46 0.90
for ease of installation / maintenance
! The luminaires uses an open construction ballast or high TKC 203 /136 HF 1 x 'TLD' 36W / 'TL' 40 W 240 0.16 0.95
frequency electronic ballast TKC 203 /236 HF 2 x 'TLD' 36W / 'TL' 40 W 240 0.30 0.95
! Choice of powder-coated and vitreous enamelled reflectors
TKC 203 / 236
Applications
! Small offices Ordering Data
! Conference rooms
! Reception and public service areas Type Ordering No Quantity Dimensions Net Weight Gross Weight Volume
! Recreational areas (restaurants, cafeterias) per box (mm) (kg) (kg) (m3)
! Textile mills
TMC 501 /136 HPF 1300 51475 6 1305 x 171 x 101 1.50 x 6 9.70 0.023
TMC 501 / 136 Installation
! Holes for (wood) screw, fixing and knockouts for suspension TMC 501/236 HPF 1300 51465 6 1305 x 171 x 101 2.00 x 6 13.10 0.023
mounting by means of Ø 19mm conduits. TMC 501 / 136 HF 1300 97585 6 1305 x 171 x 101 1.50 x 6 9.70 0.023
TMC 501 /236 HF 1300 04685 6 1305 x 171 x 101 2.00 x 6 13.10 0.023
Compliances TKA 2033 reflector 1308 24315 6 1270 x 260 x 140 2.20 x 6 15.80 0.050
! IP 20
! Safety class I TKA 2023 reflector 1308 24405 6 1270 x 260 x 140 2.50 x 6 16.80 0.050
* Data for LPF versions available on request
TKC 203 comprises of 1 No. reflector TKA and 1 No. batten TMC 501

IP 20

Dimensions (mm)

TMC 501 / 136


47
35
47
1243
109
47
600
TMC 501 / 236 35
43

1243
47

600 70
TKC 202 / 136 and 203 / 136

230

1243

TKC 202 / 236 and 203 / 236 600


47

70

1243
230

Battens

92 93
Battens
Battens TMC 55 Series TMC 55 Series

Technical Data

Type For Lamp Nominal Mains Current Nominal


Voltage (V) (A) Power Factor
General Description
Functional and economical general purpose basic batten for
'TL'/TL'D fluorescent lamp. For surface mounting on the wall or TMC 55/136 HPF 1 x ‘TL’D 36W / ‘TL’ 40W 240 0.23 0.90
ceiling. TMC 55/136 HF 1 x ‘TL’D 36W / ‘TL’ 40W 240 0.16 0.95
TMC 55/236 HPF 2 x ‘TL’D 36W / ‘TL’ 40W 240 0.46 0.90
Features
! The channel is made of CRCA sheet steel, powder coated grey TMC 55/236 HF 2 x ‘TL’D 36W / ‘TL’ 40W 240 0.30 0.95
TMC 55 / 236
with CRCA cover, powder coated white TKC 24/236 2 x ‘TL’D 36W / ‘TL’ 40W 240 0.46 0.90
! The luminaire uses copper ballast or high frequency electronic
ballast
! Vitreous enamelled reflector can be used along with channel
! Designed for ceiling / surface mounted with special provision for Ordering Data
cable entry from side
TKC 24 / 236
Type Ordering No Quantity Dimensions Net Weight Gross Weight Volume
Applications per box (mm) (kg) (kg) (m3)
! Small offices
! Conference rooms TMC 55/136 HPF 1300 52565 6 1272 x 190 x 110 2.50 x 6 15.00 0.027
TMC 55 / 136 ! Reception and public service areas (restaurants, cafeterias) TMC 55/136 HF 1300 22425 6 1272 x 190 x 110 2.50 x 6 15.00 0.027
! Shops TMC 55/236 HPF 1300 52595 6 1272 x 190 x 110 3.00 x 6 19.00 0.027
! Textile mills
TMC 55/236 HF 1300 52505 6 1272 x 190 x 110 3.00 x 6 19.00 0.027
Installation TKC 2423 reflector 1308 24245 6 1325 x 295 x 215 3.40 x 6 27.00 0.080
! Holes for (wood) screw, fixing and knockouts for suspension
mounting by means of 19mm conduits.

Compliances
! IP 20
! Safety class I

IP 20

Dimensions (mm)

TMC 55/136
1236
600

55
45
85

TMC 55/236
1236
600

100
55
45
40

Battens

94 95
Battens
Battens Proton TMS 021 Proton TMS 021

IP 20
Technical Data

Type For Lamp Nominal Mains Current Nominal


Voltage (V) (A) Power Factor
General Description
• Functional general purpose basic batten for TL’D fluorescent lamp TMS 021/136 LPF 1 x TL’D 36W 240 0.365 0.44
suitable for surface mounting on wall or ceiling
TMS 021/136 HPF 1 x TL’D 36W 240 0.23 >0.80
TMS 021/136 Features TMS 021/136 HF 1 x TL’D 36W 240 0.17 0.95
• The channel is made of single piece construction made of TMS 021/236 LPF 2 x TL’D 36W 240 0.41 0.44
powder-coated CRCA sheet steel, eliminating spot welds & TMS 021/236 HPF 2 x TL’D 36W 240 0.42 0.87
hence rust free
TMS 021/136 HF 2 x TL’D 36W 240 0.30 0.95
• Specially designed polycarbonate lamp holder and brackets for
high durability
• Integral lamp holder and brackets for ease in maintenance
TMS 021/236 • Luminaire uses open construction ballast or high frequency Ordering Data
electronic ballast
• Choice of side reflectors available Type Ordering No Quantity Dimensions Net Weight Gross Weight Volume
per box (mm) (kg) (kg) (m3)
Applications
• Small offices TMS 021/136 LPF 1300 97775 6 1230 x 230 x 145 8.80 10.00 0.041
• Cove lighting applications TMS 021/136 HPF 1300 97885 6 1230 x 230 x 145 0.90 10.20 0.041
• Shops and hotels restaurants TMS 021/136 HF 1300 97995 6 1230 x 230 x 145 6.50 7.70 0.041
TMS 021/236 LPF 1300 97805 6 1230 x 230 x 145 1.60 10.50 0.041
• Public areas
TMS 021/236 HPF 1300 97815 6 1230 x 230 x 145 1.60 10.50 0.041
• Residential areas
TMS 021/236 HF 1300 97825 6 1230 x 230 x 145 0.60 4.50 0.041
• Textile mills

Installation
• Hotels for (wood) screw, fixing and knockouts for suspension
mounting by means of 19mm conduits

Compliances
• IP 20

IP 20

Dimensions (mm)

TMS 021
TMS 021/136
50
1220
74

25
TMS 021/236
1220 50
39.5
98

Battens

96 97
Battens
Battens TMX 95 TMX 95

IP 54
Technical Data

Type For Lamp Nominal Mains Current Nominal


Voltage (V) (A) Power Factor
General Description
Corrosion resistant industrial batten for ‘TL’/ ‘TL’D fluorescent lamp.
For surface mounting on the wall or ceiling. TMX 95/236 2 x ‘TL’D 36W 240 0.46 0.90
TMX 95/240 2 x ‘TL’ 40W 240 0.46 0.90
Features
! LM6 die-cast aluminium epoxy painted control gear incorporating
ballast and other accessories.
! Wiring through seamless aluminium pipe, epoxy painted. Ordering Data
TMX 95 ! Specially designed enclosed type Phenol formaldehyde
lampholders for ‘TL’ and ‘TL’D lamps for sealing lamp caps.
Type Ordering No Quantity Dimensions Net Weight Gross Weight Volume
Applications per box (mm) (kg) (kg) (m3)
Areas where corrosive vapours are present like :
! Chemical plants TMX 95 housing 1307 99605 2 1410 x 390 x 250 8.00 x 2 17.00 0.137
! Fertilizer plants TMX 95 1308 10955 48 325 x 304 x 125 1.92 2.40 0.0124
! Steel plants lampholders assembly
for ‘TL’ 40W lamps (4 nos)
Installation
! Designed for surface mounting, this luminaire can be fixed on the TMX 95 1308 10945 48 325 x 304 x 125 1.92 2.40 0.0124
wall / ceiling by means of special clamps provided on the canopy. lampholders assembly
for ‘TL’D 36W lamps (4 nos)
Compliances
! IP 54

IP 54

Dimensions (mm)

TMX 95/236
430

1335

55
Ø8
40
50

116

150

Battens

98 99