Sie sind auf Seite 1von 2

HOJA DE DATOS

ELEMENTOS DE FLUJO

UNIDAD LACT CRUDO


ESTACIÓN CASTILLA 3

Código: Version: Fecha: Página:

3618576 0 17-09-2018 1 de 2

FLOW METER
11 OPERATING PARAMETERS 64 DRIVE TRAIN ADJUSTER

Sub project Push-pull driver (current sink or current source,


12 Project number 3618576 N/A 65 Drive type
no 20 mA / channel max).

13 Project ESTACION CASTILLA 3 66 Accuracy adjuster type Verification Pulse

Duty Cycle: 50/50 nominal (may vary to 60/40


14 Enterprise ECOPETROL S.A. 67 Temp compensation type
with temperature).

15 Site ESTACION CASTILLA 68


16 Area -- Cell -- Unit 69
17 Related equipment --- 70 REGISTER OR TOTALIZER
18 71 Register/Totalizer type Mechanical Counter
Service Crude Oil Metering Unit
19 72 Enclosure type Class 1 Div 1 Gr. C&D

20 P&ID/Reference dwg number 3618576-C01-001 73 Signal power source N/A

Nine (9) digits


21 Upstr line/nozzle number N/A 74 Totalizer reset style Non Resetable
Reading in Barrels

Nine (9) digits


22 Upstream line pipe spec 10" SCH 40 75 Integral indicator style Non Resetable
Reading in Barrels
23 Upstr line nominal size 10" Rating 300 76 Cert/Approval type UL Listing
24 Upstr line conn type 10" Style RF 77 Mounting location/type Upstream Filter
25 Upstr line material type Carbon Steel 78 Enclosure material Carbon Steel
26 Inline hazardous area cl. 01-ene Class/Div C/D Group 79 Pulse Transmitter Yes
27 Inline area min ign temp N/A Temp ident number N/A 80
28 Minimum inlet pressure 288 psig 81 PERFORMANCE CHARACTERISTICS
29 Maximum inlet pressure 390 psig 82 Max press at design temp 390 psig At 200 °F
30 Minimum temperature 167 °F 83 Min working temperature 167 °F Max 200 °F
31 Maximum temperature 200 °F 84 Max viscosity limit 124,46 cP
32 Min liquid std flow rate 1998 GPM 85 Accuracy rating ±0.15% Ref Full Scale
33 Max liquid std flow rate 2917 GPM 86 Repeatability ±0.02% Ref Full Scale
34 Minimum liquid viscosity 85,36 Cp @ 170ºF 87 Flow rate LRL 1998 GPM URL 2917 GPM
35 Maximum liquid viscosity 124,46 cP @ 190ºF 88 Recommended filter size MFR
36 Max pressure differential MFR 89 Pressure drop at URL 5 Psi
37 Material Name Carbon Steel 90 Min ambient working temp 65,7 °F Max 92,5 °F
38 Matl density at ref temp N/A At N/A 91 Max sensor to receiver lg N/A
39 NFPA health hazard MFR Flammability MFR Reactivity 92
40 93
41 94 ACCESSORIES
42 95 Strainer Yes
43 FLOWMETER BODY 96 Air/Vapor eliminator No
44 Body/Housing type Carbon Steel - Double Case 97
45 Inlet conn nominal size 10 Inch Rating 300 98
46 Outlet conn nominal size 10 Inch Rating 300 99 SPECIAL REQIREMENTS

FIT-75173
FLANGE
47 End conn termn type Style ANSI B16.5 100 Custom tag FIT-75174
FINISH:125 - 259 AARH
FIT-75175

48 Flow direction/Mounting Left to Right 101 Reference specification JB10-S6


49 Body/Housing material Carbon Steel - Double Case 102 Compliance standard API MPMS 5.2
50 103 Calibration report Yes
51 104 Material certificate Yes
52 105 Service design Crude Oil
53 106
54 MEASURING CHAMBER 107
55 Displacement element type Rotaring Element 108 PHYSICAL DATA
56 Construction style Positive Displacement 109 Estimated weight 1184 Kg
57 Nominal meter size 10" 110 Face-to-face dimension 41"
58 Sensor style Rotary Vane 111 Overall height 44.8
59 Displacement element matl Cast Iron 112 Removal clearance Yes

Rotaring Element: Cast Iron


60 Measuring chamber matl 113 Signal conn nominal size MFR Style NPT
Blades: Aluminum

61 Bearing/Bushing matl BAL Type, 440C Stainless Steel 114 Mfr reference dwg MFR
62 Shaft material Shaft: 17-4 PH Stainless Steel 115
63 116
117 CALIBRATIONS AND TEST INPUT OR TEST SCALE
118 TAG NO/FUNCTIONAL IDENT MEAS/SIGNAL/TEST LRV URV LRV URV FACTOR
119 FIT-75173 Volume-Accum total scale 0 99.999.999 0 99.999.999 1
120 FIT-75174 Volume-Totalized scale 0 99.999.999 0 99.999.999 1
121 FIT-75175 Flow rate-Scale 0 9.999 1998 2917 1
122
123 COMPONENT IDENTIFICATIONS
124 COMPONENT TYPE MANUFACTURE MODEL NUMBER
125 METER FMC TECNOLOGY JB10-S6
126
127
128
Rev Date Revision Description By Appv1 Appv2 Appv3 REMARKS

Volumen II- Pag.526


HOJA DE DATOS
TRANSMISOR DE FLUJO

UNIDAD LACT CRUDO


ESTACIÓN CASTILLA 3

Código: Versión: Fecha: Página:

3618576 0 17-09-2018 2 de 2

11 FLOWMETER BODY AND HOUSING 56 PERFORMANCE CHARACTERISTICS


12 Body/Housing type In line 57 Max press at design temp 390 psig
13 Inlet conn nominal size 10" Rating 300 58 Min working temperature 167°F
14 Outlet conn termn type 10" Rating 300 59 Max viscosity limit 124,46 cP
15 End conn termn type Flange Style RF 60 Accuracy rating ±0.15% Quantity Full Scale
16 Flow direction/Mounting Left to Right 61 Repeatability ±0.02%
17 Body/Housing material Carbon Steel - Double Case 62 Flow rate LRL 1998 GPM
18 Cap/End cover material N/A 63 Mater Mean K-factor 1
19 Seal/O-ring material Buna - N 64 Recommenden filter size MFR
20 65 Pressure drop at URL 5 psi
21 66 Min ambient working temp 65.7 °F
22 MEASURING CHAMBER 67 Contact ac rating N/A
23 Displacement element type Rotaring Element 68 Contacts dc rating N/A
24 Construction style Positive Displacement 69 Max sensor to receiver lg N/A
25 Nominal meter size 10" 70
26 Sensor style Rotary Vane 71
27 Displacement element matl Cast Iron 72

Rotaring Element: Cast Iron


28 Measuring chamber matl 73 ACCESSORIES
Blades: Aluminum

29 Bearing/Bushing matl BAL Type, 440C Stainless Steel 74 Strainer No


30 Shaft material Shaft: 17-4 PH Stainless Steel 75 Strainer mesh size No
31 76 Valve style No
32 77 Lubrication system No
33 DRIVE TRAN AND ADJUSTER 78 Air/Vapor eliminator No

Push-pull driver (current sink or


34 Drive type current source, 20 mA / channel 79 End connection adapter N/A
max).

35 Accuracy adjuster type Verification Pulse 80


Duty Cycle: 50/50 nominal (may vary
36 Temp compensation type 81
to 60/40 with temperature).
37 82
38 TRANSMITTER OR TOTALIZER w/wo SWITCHES 83 SPECIAL REQUIREMENTS
39 Configuration type Pulses / Pre-amplifier 84 Custom tag FIT-75173 / FIT-75174 / FIT-75175
40 Aux input signal type Yes 85 Reference specification JB10-S6
Type: Push-pull driver (current sink or
41 Output signal type 86 Compliance standard API MPMS 5.2
current source, 20 mA / channel

42 Enclosure type no/class N/A 87 Calibration report Yes

43 Control mode Local / Integrated 88 Material certificate Yes


44 Digital communication std HART Versión 7 89 Service design Crude Oil
45 Signal power source 24 VDC 90
46 Totalizer reset style NA 91
47 Contacts arragement Power, Signal Quantity 2 92

≥ 47 milliseconds minimum at 300


48 Pulse per revolution 93 PHYSICAL DATA
RPM.

49 Integral indicator style MFR 94 Estimated weight 1184 Kg

50 Signal termination type MFR 95 Face-to-face dimension 41"


51 Cert/Approval type Calibration & Materials Certificates 96 Overal all height 44.8"

52 Mounting location/type Upstream Filter 97 Removal clearance Yes

53 Integral printer style N/A 98 Signal conn nominal size MFR Style NPT
54 Enclosure material MFR 99 Mfr reference dwg N/A
55 100
101 CALIBRATIONS AND TEST INPUT OR TEST OUTPUT OR SCALE
102 TAG NO/FUNCTIONAL IDENT MEAS/SIGNAL/TEST LRV URV ACTION LRV URV

103 Volume-Accum total scale 0 99999999 Direct 0 99999999


FIT-75173
FIT-75174
104 FIT-75175 Volume-Totalized scale 0 99999999 Direct 0 99999999
105 Flow rate-Scale 0 9999 Direct 1998 2917
106
116
117 COMPONENT IDENTIFICATIONS
118 COMPONENT TYPE MANUFACTURE MODEL NUMBER
119 METER FMC TECNOLOGY JB10-S6
120
121
122
Rev Date Revision Description By Appv1 Appv2 Apvv3 REMARKS