FC

C-300A W
Wind sp
peed alarrm
Installaation insttruction

1. Main techniical indicatorrs

1.1 Technicaal parameterrs

Measuring range:0~60
r 0 m/s

output signaal :Pulse siignal

Voltage:AC
C48V (Not beyond
b AC500V)

Voltage deviiation:±10%
%

Measuremen :(0.5±0.05* V) m/s


nt accuracy:

Line:3 linees

On the coontrol panell,press


《 Wind speed 》 or 《 wind
Wiind speed/
force 》 button
b ,thee LED
Wiind force
displays the
t switch iin wind
speed and wind force
Press 《 Alarming setting 》
Alarming button, set the first level
device alarm and the second level
alarm in turn
When you setting the
Setting +
alarming, adjust the value of
Setting -
alarming by + or -

2. Instruction
2.1 Supply voltage: AC48V
2.2 Current: <100MA
2.3 First alarming wind speed: 1~30 m/s
2.4 Second alarming wind speed: 1~30 m/s
2.5 Control output wind speed: 1~30 m/s
2.6 Delay Power off time: 5s
2.7 Working type: continuous
2.8 Installation and connection line
2.8.1 The display should be fixed the position where the controller easily to watch.
2.8.2 The wind speed sensor should be fixed on main girder upside without covering
2.8.3 The display main connection line is AC48V plug, please plug into corresponding
socket.
2.8.4 There are six connection line pillars are the switching signal output of the alarming
and control equipment cutting off.
2.8.5 Plug the signal line into display.
2.8.6 Operation instruction
2.8.6.1 The wind speed sensor should be fixed on main girder upside without covering
2.8.6.2 Connect sensor and display cable, connect the AC48V, then it can display wind
speed.
2.8.6.3 Alarming setting
A. In the case of power on and display is ok, press the《Alarming setting》button, it will
display a number, the number which display is the value of first alarming value, press
《Setting +》或《Setting - 》to plus or minus the first alarming value.
B. After setting the first alarming value, press the《Alarming setting》again, then it will
display a number, the number which display is the value of second alarming value, press
《Setting +》或《Setting - 》to plus or minus the first alarming value.
C. After setting the second alarming value, press the《Alarming setting》again, then the
screen will show the normal, the setting is finished.
2.8.6.4 The power button can be used as the Reset button. If the display death, turning
off the button and turn on again. Then it will be ok.
running first Second
indicator alarming alarming
light indicator indicator
green light light
Yellow red
Display/screen
wind speed wind force alarming
setting setting setting
setting + setting -
Second alarming output First alarming output
always opening always always opening always
opening terminal close opening terminal close
terminal terminal terminal terminal
Wind Wind speed Name
force (m/s)
0 0.0~0.2 Calm
1 0.3~1.5 Light air
2 1.6~3.3 Light Breeze
3 3.4~5.4 Gentle Breeze
4 5.5~7.9 Moderate breeze
5 8.0~10.7 Fresh breeze
6 10.8~13.8 Strong breeze
7 13.9~17.1 Moderate gale
8 17.2~20.7 Fresh gale
9 20.8~24.4 Strong gale
10 24.5~28.4 Whole gale
11 28.5~32.6 Storm
12 32.7~36.9 Hurricane

Wind force and wind speed