Vertical Overall Cabinet Electrical Knockouts

Upflow A B C J K L
Model Width Depth Height Vertical
1/2” 1/2” 3/4”
in 22.5 21.3 22.5 Model
006 - 012 cm 57.2 54.1 57.2 Low Low Power
in 22.4 22.4 40.5 Voltage Voltage Supply
015 - 030 cm 56.9 56.9 102.9
in 2.9 5.9 8.1
in 22.4 25.4 46.5 006 - 012 cm 7.4 15.0 20.6
036 - 042 cm 56.9 64.5 118.1
in 4.0 7.0 10.0
in 25.4 29.1 50.5 015 - 060 cm 10.2 17.8 25.4
048 - 060 cm 64.5 73.9 128.3

Water Connections - Standard Units


Vertical 1 2 3 4 5
Upflow Loop Loop Loop Loop Cond. 3/4” FPT HWG In 1/2” FPT HWG In 1/2” FPT Loop In/
Model In In Out Out Out
D E F E H I DD EE FF EE FPT
in 3.8 1.5 8.7 1.5 6.1 1.5
006 - 012 cm 9.7 3.8 22.1 3.8 15.5 3.8
Not Available 1/2”

in 3.7 1.9 9.7 1.9 7.0 1.9 11.7 1.6 14.9 1.6
015 - 018 cm 9.4 4.8 24.6 4.8 17.8 4.8 29.7 4.1 37.8 4.1
1/2”

in 3.7 1.9 9.7 1.9 7.0 1.9 12.4 1.6 15.7 1.6
024 - 030 cm 9.4 4.8 24.6 4.8 17.8 4.8 31.5 4.1 39.9 4.1
3/4”

in 3.7 1.8 12.7 1.8 8.0 1.8 15.2 1.6 18.4 1.6
036 - 042 cm 9.4 4.6 32.3 4.6 20.3 4.6 38.6 4.1 46.7 4.1
3/4”

in 3.7 1.8 12.7 1.8 8.0 1.8 15.2 1.6 18.4 1.6
048 - 060 cm 9.4 4.6 32.3 4.6 20.3 4.6 38.6 4.1 46.7 4.1
1”

Discharge Connection Return Connection


Duct Flange Installed (+/- 0.10 in, +/- 2.5mm) Using Return Air Opening
Vertical
Model O P S T
M N Supply Supply Q R Return Return U
Width Depth Depth Height
in 6.2 6.2 9.0 9.0 5.3 2.4 16.0 10.2 1.0
006 - 012 15.7 15.7 22.9 22.9 13.5 6.1 40.6 25.9 2.5
cm
in 7.2 4.2 14.0 14.0 6.7 2.2 18.4 20.3 1.1
015 - 030 18.3 10.7 35.6 35.6 17.0 5.6 46.7 51.6 2.8
cm
in 7.2 6.0 14.0 14.0 6.5 2.1 22.9 24.3 1.1
036 - 042 18.3 15.2 35.6 35.6 16.5 5.3 58.2 61.7 2.8
cm
in 8.2 5.7 16.0 18.0 7.3 2.1 26.2 28.3 1.1
048 - 060 20.8 14.5 40.6 45.7 18.5 5.3 66.5 71.9 2.8
cm

Recommended Minimum Installation Clearances for Vertical Units* ‡ † * 1”

Back of unit
1”
Side opposite return air
Air Coil Side

6” Front if hard piped


Return Air Side 1” 1”
Ducted return

1” - ‡ *Add for duct width


- † Add 2” for 1” filter frame/rail or 3” for 2” filter frame/rail
Front
Free (open) return - calculate required dimension for a maximum
velocity of 600 fpm
6”
*Field installed accessories (hoses, air cleaners, etc.) and factory WSE option will
require additional space. Top supply air is shown, the same clearances apply to
bottom supply air units.

ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.

LC516 - 47 Page ______ of ______


Field Installed
Discharge Flange Access Panels

Standard Filter Bracket

Air Coil
B
P N N P BSP
ASP

Front
O O
Front

A ASP
CCP

Q Air Coil Side Air Coil Side M


Top View-Right Return Top View-Left Return

R S S R
Isometric
View
U U

Air Coil Air Coil

T T BSP
ASP

C C
Power Supply EE
3/4" [19.1 mm] HV
Knockout 5
Low Voltage
1/2" [12.7 mm] LV 4
Knockout CCP 2 FF
Low Voltage
ASP ASP 1/2" [12.7 mm] LV
3 DD
Knockout
L F
K 1 H
Front Back Back Front J D
ASP

Right Return Right View Left Return Left View U E


- Air Coil Opening - Air Coil Opening
A

1. While clear access to all removable panels is not required, installer should take care to comply with all building codes and allow adequate clearance for
future field service.
2. Front & Side access is preferred for service access. However, all components may be serviced from the front access panel if side access is not available.
3. Discharge flange is field installed.
4. Condensate is 3/4” FPT.
5. Water connections for optional hot water generator are 1/2” FPT.
6. Units shipped with filter rails. These rails should be removed for return duct connection. See Aff---- for accessory air filter frame with duct collar.

CCP = Control/Compressor Access Panel


BSP = Blower Service Panel
*ASP = Additional Service Panel (not required)

*ASP are removable panels that provide additional access to the units interior. Clear access to ASP panels is not required and they are not to be
used in place of the mandatory CCP and BSP panels.

ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.

LC516 - 48 Page ______ of ______


Vertical Units

Left Return
Supply Air
Opening

Air Coil
Front

ASP ASP

CCP and BSP

Right Return
Supply Air
Opening
Air Coil

Front

ASP ASP

CCP and BSP

= mandatory 2 service access

= (optional) additional 2 service access

ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer
Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties,
but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com.

LC516 - 49 Page ______ of ______