PROVISION OF WATER
INJECTION PUMP RENTAL
Pump Assessment and Inspection Report
Client
Petroenim
Document Title
Issued fo Review
Contact
Engineering Consultant
Pelita Air Service Blok H No.8
Depok 16434, Indonesia
Executive Summary
Pump assessment and inspection is performed to ensure reliability of the pump when delivering and
injecting produced water from water storage pond which is located at Processing Station – SP Betun
to Betun-05 injection well with an approximate distance of 2.5 km.
Based on the pump catalogue attached in Appendix A, the following parameters for the Water
Injection Pump (DG 25-50 x 10) have been summarize as follow:
Design Flowrate Q : 25 m3/h ~ 3777 BWPD
Pump discharge pressure Pdischarge : 710.9 psig
Pump discharge head Hdischarge : 500 m
Net positive head required NPSHr : 2.8 m
Pump Shaft Speed Rpm : 2950
Pump Estimated Efficiency E : 54 %
Brake horse power P : 75 kW
Based on the pump assessment and inspection attached in Appendix B, the following results for the
Water Injection Pump (DG 25-50 x 10) have been summarize as follow:
Required Flowrate Q : 3000 bpd
Pump discharge pressure Pdischarge : 420 psig
Pump discharge head Hdischarge : 309 m
Net positive suction head available NPSHA : 6.5 m
Net positive head required NPSHR : 2.8 m
Pump Shaft Speed Rpm : 2950
Pump Estimated Efficiency E : 32 %
Brake horse power : P : 75 kW
NPSHa value is bigger than NPSHr, this conclude that the pump will not having problem with
cavitation for suction head to minus 2 m (pump suction is 2 m lower than the pump center line). The
maximum suction head as per calculation is minus 5 m
To deliver continuous flowrate on 3,000 bwpd the pump shall have discharge pressure on 420 psig.
This pressure could be achieved by throttling the discharge valve and/or might be effected by the
injection well restriction characteristic. Hence, pressure class rating #300 is required. It is not
recommended to run the pump with flowrate more than 3,600 bwpd, since cavitation might occur.
The pump’s efficiency decreases because of required power stay the same but pump head is
smaller. However, It conclude that pump is ready to be operated while it will consump a slightly more
power than it should have.
Table of Contents
1.1 General 5
1.4 Definitions 6
1.5 Abbreviations 7
2.2 Requirement 8
4.2 Recommendation 15
5.0 References 16
The produce fluids from wells are delivered via pipeline to Betun Production Station (SP
Betun) for futher processing. The oil production are delivered to Pertamina tank farm via
pipeline whilst the produced water from the field which is approximately 3,000 bwpd injected
to BTN-05 well via 2.5 km of pipeline from SP Betun by water injection pumps.
Since water production rate increases and soon will exceed the capacity of the existing water
injection pump, therefore an additional water injection pump will be added.
The new pump will have capacity around 3,000 bwpd and will be located adjacent to the
existing water injection pump at SP Betun.
The objective of this document is to perform assessment and inspection of new Water
Injection Pump.
This document presents the pump NPSH analysis, performance and durability to deliver
water from open water pond at SP Betun to BTN-05 Injection well.
1.4 Definitions
In and throughout this document, unless the context otherwise requires, the following
definitions apply:
COMPANY : Petroenim Betun Selo
CONSULTANT : Engineering Consultant
PROJECT : Provision of Water Injection Pump Rental
1.5 Abbreviations
CL Centre Line
SF Safety Factor
ID Internal Diameter
MW Molecular Weight
OD Outside Diameter
WT Wall Thickness
There following parameters are considered as a key input for pump assessment as shown in
Table 2-1 2.1 below:
Table 2-1 Pump data (DG 25-50x10) based on Catalogue
Description Value
Multistage
Type
Centrifugal Pump
Capacity (bwpd) , (m3/h) 3,770 (25)
Head (m) 500
NPSHr (m) 2.8
Shaft speed (rpm) 2950
Power (kW) 75
Efficiency (%) 54
2.2 Requirement
Description Value
The NPSH is supplied from the system and is solely a function of the system design on the
suction side of the pump. Consequently it‘s controlled by the system designer.
To avoid Cavitation, the NPSH available (NPSHa) from the system must be greater than the
NPSH required (NPSHr) by the pump.
NPSHa = Ha + Hs – Hvp – Hf
Where
Ha = Atmospheric Head
Hs = Static Head
Hvp = Vapor Head
Hf = Friction Head
inlet
Surface Pressure
Water Vapor Pressure Reference Table 0 PSIG
Water Temp. Vapor Pressure
(Deg. F) (ft. Water) inlet
80 1 -h
100 2 (Negative) Height
liquid level
120 4
140 7
180 18
200 28
212 33.96
Static Head
Water Vapor Pres. @ Sea Level Height: -6.6 ft.
40
Vapor Pres.(ft. Water)
Constants / Assumptions:
Mean Operating Fluid Temperature: 45 ºF Total Flow Through Pump: 87.5 gpm Atmospheric Pressure: 14.70 PSIA 33.96 ft. Water
Pumped Fluid: WATER Vapor Pressure of Liquid: 0.75 ft. water Surface Pressure: 0 PSIG (if exposed to air surface pressure = 0)
Piping Configuration:
Pipe
Sub System#: 1 2 3 4 5 6
Pipe Diam. (Nom): 3 inch 1 inch 1 inch 1 inch 1 inch 1 inch
Pipe Length: 30 feet 0 feet 0 feet 0 feet 0 feet 0 feet
Flow Rate: 87.5 gpm 0 gpm 0 gpm 0 gpm 0 gpm 0 gpm
Total
Pipe Pressure Drop: 0.5 ft. Water 0.0 ft. Water 0.0 ft. Water 0.0 ft. Water 0.0 ft. Water 0.0 ft. Water 0.5
0.2 psi 0.0 psi 0.0 psi 0.0 psi 0.0 psi 0.0 psi 0.2
Valves (Fully Open) / Fittings
1 2 3 4 5 6
Eq. Eq. Eq. Eq. Eq. Eq.
Qt. Length Total Qt. Length Total Qt. Length Total Qt. Length Total Qt. Length Total Qt. Length Total
90 Ells 5 20 100 0 20 0 0 20 0 0 20 0 0 20 0 0 20 0
45 Ell 5 16 80 0 16 0 0 16 0 0 16 0 0 16 0 0 16 0
Globe Valve 1 340 340 0 340 0 0 340 0 0 340 0 0 340 0 0 340 0
Angle Valve 1 150 150 0 150 0 0 150 0 0 150 0 0 150 0 0 150 0
Ball Valve 1 8 8 0 8 0 0 8 0 0 8 0 0 8 0 0 8 0
BF-Valve 1 29.9 29.9 0 29.9 0 0 29.9 0 0 29.9 0 0 29.9 0 0 29.9 0
Ck-Valve 1 55 55 0 55 0 0 55 0 0 55 0 0 55 0 0 55 0
Stand. Tee - flow through run 0 20 0 0 20 0 0 20 0 0 20 0 0 20 0 0 20 0
Stand. Tee - flow through branch 0 60 0 0 60 0 0 60 0 0 60 0 0 60 0 0 60 0
- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Total
Eq. Length Total: 762.9 0 0 0 0 0 762.9
Fitting Pressure Drop: 3.5 ft. water 0.0 ft. water 0.0 ft. water 0.0 ft. water 0.0 ft. water 0.0 ft. water 3.5
1.5 psi 0.0 psi 0.0 psi 0.0 psi 0.0 psi 0.0 psi 1.5
Description
Additonal Pressure Drops: input here 0.0 ft. water
input here 0.0 ft. water
input here 0.0 ft. water
input here 0.0 ft. water
input here 0.0 ft. water
Total: 0.0 ft. water Total Head Loss (Pipe + Fittings + Additional Drops) : 763.4
Results
The new water injection pump perfirmance test result is shown in Table 3.1 below:
Note
1 Eff = (flowrate x Total Head x Spec Gravity)/(Power x 3960)
NPSH Test
DG 25-50 x 10
Discharg
Suction Head Spec Total Temp Flowrate Power Speed
No e Head
(ft) Gravity Head (ft) (Deg F) (gpm) (bhp) (rpm)
(ft)
1 Full open 0 0.998 1014 1014 95 87.5 75 2950
2 80% open 0 0.998 1014 1014 95 87.5 75 2950
3 50% open 0 0.998 1014 1014 95 87.5 75 2950
4 25% open 0 0.998 922 922 95 87.5 75 2950
Note
1 Suction valve throttling methode
2 Total Head developed is monitored which total 3% drop
DG 25-50 x 10
Bearing
Time Speed Disharge
No Temp Leakage Remark
(minutes) (rpm) Head (st)
(Deg F)
Gland Packing Seal Type requires
1 Start shutoff Water drips
drips for cooling
2 15 2710 1150 ft 104 No leakage
3 30 2710 1151 ft 104 No leakage
4 45 2710 1152 ft 104 No leakage
5 60 2710 1153 ft 104 No leakage
6 75 2710 1154 ft 104 No leakage
7 90 2710 1155 ft 104 No leakage
8 105 2710 1156 ft 104 No leakage
9 120 2710 1157 ft 104 No leakage
10 135 2970 920 ft 104 No leakage Engine exhaust vibrate heavily
11 150 2970 920 ft 104 No leakage tightened exhaust U-Bolt
12 165 2970 920 ft 104 No leakage No execsise vibration occur
13 180 2970 920 ft 104 No leakage
14 195 2970 920 ft 104 No leakage
15 210 2970 920 ft 104 No leakage
16 225 2970 920 ft 104 No leakage
17 240 2970 920 ft 104 No leakage
Note
1 discharge head 500 psig change to ft
1 discharge head 400 psig change to ft
The new water injection pump assessment & inspection result is shown in Table 4.1 below:
Table 34.1 New Water Injection Pump (DG 25-50 x 10) Result
Case
Parameter Unit
Pump Data Pump Test Pump Required
Discharge Flowrate m3/h (bwpd) 25 (3,777) 19.87 (3,000) 19.87 (3,000)
Discharge Pressure psig 711 420 300
(Note-1)
Discharge Head ft (m) 1640 (500) 1014 (309) 689 (210)
Suction Head ft (m) - -6.5 (-2) -6.5 (-2)
NPSHa (Note-2) ft (m) - 22.52 (6.86) 22.52 (6.86)
NPSHr ft (m) 9.2 (2.8) 9.2 (2.8) 9.2 (2.8)
Shaft speed rpm 2950 2950 -
Pump efficiency % 54 32 -
Brake Horse Power (Note-3) kW 75 75 -
Note:
1. The Disharge Head is calculated from: Discharge Head = (Discharge Pressure / (2.31 x Specific Gravity))
2. The NPSHA is calculated from test condition refer to actual condition at site
3. BHP is measured from engine shaft rotation plotted to engine curve
Pump installation elevation system of -2 m pump suction line to pump centre line will produce
NPSHa value = 6.86 m with SF 2.5, the required NPSH (NPSHr) is smaller than the NPSHa
value, hence the pump will be working properly without having cavitation issue when
discharge flowrate on 3,000 bwpd and discharge pressure on 420 psig.
The minimum of NPSHa value is at least 1 m bigger than NPSHr, which is maximum depth
of pump suction for this pump might installed -5m to pump centre line.
The maximum discharge flowrate for this pump may reach 3,600 bwpd, whilst discharge
pressure will decrease to circa 390 psig
Finally, the pump is capable to operate at required condition whilst power consumption is
slightly more than what the requirement need.
4.2 Recommendation
Discharge flowrate shall not be set more than 3,600 bwpd because it can cause heavy
cavitation then consequently will damage the pump
The pump is a non self priming type, therefore several important point shall be considered;
Y-strainer shall be installed at pump downstream to catch solid particle entering the pump
4.2.5 Flowmeter shall be installed at pump upstream to check pump performance continously
5.0 References
API 610 Centrifugal pumps for petroleum, petrochemical and natural gas industries
ANSI/HI 14.6 Rotodynamic Pumps for Hydraulic Performance Acceptance Tests
ASME B 31.3 Process Piping
DG Pump Catalogue Boiler Water Supply Pump
DG PUMP CATALOGUE