Sie sind auf Seite 1von 2

Design for JTA Anchor Channel

Project: WTC II in Indonesia Print date: 26-Nov-10


Pos. No.: Cantilevel at Level 3

Input Channel length /


Channel type: Loading: No. of anchors: Part No.:
W50/30 Pair load 150 mm 300 mm / 3 anchors JTA W 50/30–300–3A
Load distance: 150 mm
Tension load [kN]: Member thickness [mm]: Concrete strength: Reinforcement:
8.61 150 C30/37 Ø 10 @ 75 mm

Shear load [kN]: Edge distance [mm]: Corner: Crack conditions:


11.81 100 no uncracked
factored loads per point

Design resistance NRd,s / VRd,s 17.22 17.22 [kN]

Strength factors for channel length and load position stirrup Ø 10 @ 75 mm


Tension NRd,s [kN] SN NRd,sg [kN]
Steel 17.22 * 1.00 = 17.22
Shear VRd,s [kN] SV VRd,sg [kN]
Steel 17.22 * 1.00 = 17.22

Tension NRd,s [kN] CN CN * NRd,s [kN]


reinf. Concrete 17.22 * 1.35 = 23.31
Shear NRd,s [kN] Cre,V Cre,V*Vd [kN]
reinf. Concrete 17.22 * 2.09 = 36.05

Concrete strength and geometrical factors


concrete crack Edge Corner concrete
strength conditions influence influence factor
Tension 1.00 * 1.00 * 0.82 * 1.00 = 0.82 = YNca1
Shear 1.00 * 1.00 * 0.60 * 1.00 = 0.60 = YVca1

Checks According to CEN/TS-1992-4-3:2008 and ETA-09/0338


Tension NEd [kN] NRd,sg [kN] bN,S Check
Steel 8.61 / 17.22 = 0.50 ≤1 OK!
Shear VEd [kN] VRd,sg [kN] bV,S Check
Steel 11.81 / 17.22 = = 0.69 ≤1 OK!

Tension NEd [kN] YNca1 CN * NRd,s [kN] = NRd,c [kN] bN,C Check
reinf. Concrete 8.61 / [ ( 0.82 * 23.31 ) = 19.03 ] = 0.45 ≤1 OK!
Shear VEd [kN] YVca1 Cre,V*Vd [kN] = VRd,re [kN] bV,C Check
reinf. Concrete 11.81 / [ ( 0.60 * 36.05 ) == 21.47 ] = 0.55 ≤1 OK!

Version: JTA-CEN-0.1.7
Design for JTA Anchor Channel
Project: WTC II in Indonesia Print date: 26-Nov-10
Pos. No.: Cantilevel at Level 3

Interaction (combined check of tension and shear)


a a
a bN,S bV,S bN,S +bV,S Interaction
Steel 2 0.50 0.69 0.73 ≤1 OK!
a bN,C bV,C bN,Ca+bV,Ca Interaction
reinf. Concrete 1 0.45 0.55 1.00 ≤1 OK!

Summary Design OK!


Interaction-diagram
20
UNSAFE
18
actored nominal tension Nd [kN]

rrup Ø 10 @ 75 mm 16

14

12

factored load
10
reinf. Concrete

8 Steel

SAFE
0
-3:2008 and ETA-09/0338
0 2 4 6 8 10 12 14 16 18 20

factored nominal shear Vd [kN]

The design utilizes specific values for each JORDAHL anchor-channel.


When alterations are made, even for similar sizes, a new design calculation is required.

Version: JTA-CEN-0.1.7