Beruflich Dokumente
Kultur Dokumente
PVsyst TRIAL
Simulation variant :
Simulation parameters
Collector Plane Orientation
New simulation variant
Simulation date
System type
Tilt
09/12/19 13h19
PVsyst TRIAL
PV Array Characteristics
PV module Si-mono Model SYP310M
Original PVsyst database Manufacturer Risen Energy Co., Ltd
Number of PV modules In series 15 modules In parallel 215 strings
Total number of PV modules Nb. modules 3225 Unit Nom. Power 310 Wp
Array global power Nominal (STC) 1000 kWp At operating cond. 890 kWp (50°C)
Array operating characteristics (50°C) U mpp 481 V I mpp 1852 A
Total area Module area 6258 m² Cell area 5511 m²
PVsyst TRIAL
Pnom ratio 1.28
PVsyst TRIAL
PVsyst Evaluation mode
PVSYST V6.85 09/12/19 Page 2/4
PVsyst TRIAL
Inverter pack Nb. of units 98.0 Pnom total 784 kW ac
User's needs Unlimited load (grid)
Normalized productions (per installed kWp): Nominal power 1000 kWp Performance Ratio PR
7 1.0
Lc : Collection Loss (PV-array losses) 0.49 kWh/kWp/day PR : Performance Ratio (Yf / Yr) : 0.851
0.9
Ls : System Loss (inverter, ...) 0.12 kWh/kWp/day
6
Yf : Produced useful energy (inverter output) 3.53 kWh/kWp/day
0.8
[kWh/kWp/day]
5 0.7
Performance Ratio PR
PVsyst TRIAL
0.6
4
Energy
0.5
3
0.4
Normalized
2 0.3
0.2
1
0.1
0 0.0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
0.53
2.11
6.20
°C
10.31
GlobInc
kWh/m²
71.9
95.3
138.7
158.4
GlobEff
kWh/m²
69.9
92.5
134.8
153.7
EArray
MWh
68.7
90.9
126.0
138.8
E_Grid
MWh
66.3
88.0
122.0
134.2
PR
0.922
0.924
0.879
0.848
May 168.3 71.63 15.12 170.9 165.5 144.6 139.7 0.817
June 177.2 85.08 18.04 173.0 167.1 147.4 142.4 0.823
July 177.4 83.21 19.08 176.6 170.8 149.3 144.3 0.817
August 150.9 71.15 18.71 163.6 158.5 138.3 133.7 0.817
September 111.0 48.97 14.66 135.1 131.3 116.2 112.2 0.831
October 77.7 39.65 11.01 109.3 106.1 98.9 95.7 0.875
November 41.5 21.84 5.46 64.2 62.3 59.6 57.4 0.894
Legends: GlobHor
DiffHor
T_Amb
31.9
1289.2
17.22
602.72
GlobEff
EArray
E_Grid
54.7
1333.4
52.7
1288.5
0.930
0.851
PVsyst TRIAL
Inverter pack Nb. of units 98.0 Pnom total 784 kW ac
User's needs Unlimited load (grid)
7000
Values from 01/01 to 31/12
6000
Energy injected into grid [kWh/day]
5000
4000
2000
1000
0
0 2 4 6 8 10
Global incident in coll. plane [kWh/m².day]
PVsyst TRIAL
System Output Power Distribution
40000
Values from 01/01 to 31/12
35000
Energy injected into grid [kWh / Bin]
30000
25000
20000
15000
5000
0
0 200 400 600 800
Power injected into grid [kW]
PVsyst TRIAL
Inverter pack Nb. of units 98.0 Pnom total 784 kW ac
User's needs Unlimited load (grid)
-1.10%
Array nominal energy (at STC effic.)
PV loss due to irradiance level
PV loss due to temperature
Module quality loss
PVsyst TRIAL
0.00% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
1289 MWh Available Energy at Inverter Output
1289 MWh Energy injected into grid
PVsyst TRIAL
PVsyst Evaluation mode