Sie sind auf Seite 1von 1

AFFORDABLE PUMP SERVICE INC.

Flow Test Report


P.O. Box 620 Shady Cove, OR 97539 ccb#192743
541-878-0947 email dougsaffordablepump@gmail.com

Prepared for: Mike and Jakie Rushton


Owner and Address: Doug and Rene Brons 226 Felkner Rd Grants Pass, OR
Date: 11/26/2019 Technician: Fred Wahl
Static water level: unknown Drawdown:_______ unknown Recovery:______ unknown
Pump type: 1.5hp sub Pump depth:_____? Well depth: ?
Total Gallons Flowed: 4,650 Average GPM: 19.3 Comments: Technician was
not able to get well sounder probe down the borehole to check static water level readings. Well has a tag
(L87993) but there is no log in the Water Resources Dept. database. There are 2 pipes leaving the pump
house,one is connected to the manifold with a short piece of hose,possibly the supply line to 226.

Time Water Level Meter Reading Gallons/15 min GPM


9:45 4029 XXXXXXXXXXXXX xxxxxxxxxxxx
10:00 4334 305 20.3
10:15 4629 295 19.6
10:30 4921 292 19.4
10:45 5213 292 19.4
11:00 5504 291 19.4
11:15 5793 289 19.2
11:30 6086 293 19.5
11:45 6372 286 19
12:00 6661 289 19.2
12:15 6950 289 19.2
12:30 7239 289 19.2
12:45 7527 288 19.2
1:00 7816 289 19.2
1:15 8104 288 19.2
1:30 8392 288 19.2
1:45 8679 287 19.1
XXXXXXXXXXXXX XXXXXXXXXXXXX XXXXXXXXXXXX

Pressure tank type,size,and condition:__________________________________________________________


Flexcon PJR66S-20 gallon-fair condition
Controls-description and condition:_____________________________________________________________
Franklin SubDrive 75 Variable Frequency Drive-good condition
Filtration-type and condition__________________________________________________________________-
None at the pump house.

I Certify that this report is a true and accurate statement of the results of the flow test and inspection.

Dated:________________________
11/26/2019 Douglas Cox