The Indian 1 MW Floating OTEC Plant – An Overview

M. Ravindran, Director
National Institute of Ocean Technology
NIOT Campus,Velachry-Tambram Chennai, India
Ph.91-44-22460064,66 ; Fax.91-44-22460675
E-Mail:mravi@niot.ernet.in

INTRODUCTION
India is geographically well placed as far as the OTEC potential is concerned. Around
2000km of coast length along the South Indian coast, a temperature difference above 20 oC
through out the year is available. That is about 1.5 x 10 6 square kilometeres of tropical
water in the Exclusive Economic Zone around India with a power density of 0.2 MW/km 2.
Apart from this, attractive OTEC plant locations are available around Lakshedweep,
Andaman & Nicobar Islands. The total OTEC potential around India is estimated as
180,000 MW considering 40% of gross power for parasitic losses. This indicates the
promise of OTEC for India and points out the urgent need to develop OTEC technology.

BACKGROUND
The Indian OTEC programme started in 1980 with the proposal of General Electrical Co. of
USA to install a 20 MW plant off the Tamil Nadu coast and subsequently in 1982, an OTEC
cell was formed in the Indian Institute of Technology, Madras. A preliminary design was also
done in 1984 for a 1 MW closed Rankine Cycle floating plant with ammonia as working fluid.
After a bathymetric survey, a land based, 1 MW capacity OTEC plant was suggested for one
of the islands of Lakshadweep group and a detailed design report was also prepared.

In 1993, National Institute of Ocean Technology (NIOT) was formed by the Department of
Ocean Development (DOD), Government of India to pursue the research activities on ocean
energy as part of their various mission-based activities. Under this mission a major thrust
was given for the technology development for OTEC. Early 1997, DOD, Government of
India proposed to establish a 1 MW gross OTEC plant in India, which will be the first ever
MW range plant established anywhere in the world. NIOT had been exploring the
participation of national and international expertise for a joint research and development.
Saga University in Japan, headed by Prof. Uehara, has been doing excellent and practically
oriented R & D on OTEC for more than twenty five years and this team also showed keen
interest in closely working with NIOT on OTEC technology development. Considering this,
an MOU was signed in 1997 between NIOT and Saga University, Japan for a joint
development of OTEC in India. NIOT conducted detailed surveys at the proposed OTEC
site near Tuticorin, South India. Based on the temperature and bathymetric profiles, the
optimization of the closed loop systems was done with the help of Saga University in
1998[1].

The bathymetry of the coast around main land of India where cold water at a depth of 1000
m is available at about 40 km from the shore necessitates the use of a floating platform to
house the OTEC plant. There exist some locations where a shell mounted OTEC plant can
be constructed at a depth of 200 m. However, considering the future need of large plants, it
was decided to design a floating OTEC plant. NIOT aims to build a 1 MW floating OTEC
plant off the coast of Tamil Nadu near Tuticorin port on the south east coast of India which is
free of cyclones in the last four decades.

After arriving at the detailed specifications of power module a global tender was floated
during October / November ’98 for the various sub-systems like heat exchangers, turbine-
generator, seawater pumps etc. Tenders have been analysed and orders have been placed.

POWER MODULE AND SEA WATER SYSTEMS


All commercial OTEC plants are expected to be 10 - 50 MW range or larger. Therefore a 1
MW gross power output plant is selected for the present design, considering the scaling up
for the future. The design of the power module is based on a closed Rankine Cycle with
ammonia as the working fluid [2]. Titanium plate heat exchangers are suitable to such an
environment. A cold water pipe made of HDPE of 1m outer diameter is selected, as it is the
largest diameter locally available. Axial flow turbine having a higher adiabatic efficiency is
chosen for power conversion and also for easy scaling up for future. The following are the
baseline design conditions and the schematic diagram is given in Figure 1.
Gross power output 1 MW
Warm water temperature 29o C
Cold water temperature 7o C
Cold water intake 1000 m
Cold water pipe (ID) 0.90 m
The evaporator and condenser consist of four modules of plate heat exchangers, which will
be largest of its kind used for such an application. The ammonia side of the evaporator is
coated with stainless steel powder to enhance the overall heat transfer co-efficient. The
coating is expected to improve the power output by 20 – 40%

Radial inflow turbines have been previously used in the US-Mini OTEC experiment. The
power system flow rates and net power is very much dependent on the turbine efficiency.
Parametric studies showed that a 4-stage axial turbine could improve the efficiency up to
89%. The basic aerodynamic design of the turbine is done by NREC, Massachusetts, USA.
While the original intent was to operate the turbine as a direct drive at the 3000 rpm, the
commercial non-availability of the generator necessitated the use of 1: 2 reduction gear box.

The seawater pumps are of vertical, mixed flow type due to the low head and high discharge
combination. Two identical pumps are to be connected in parallel on both warm water and
cold water side and are driven by a variable speed drive to adjust the flow rates. As the
system is highly sensitive to the flow variables, a variable speed drive is an essential
component in an OTEC system.
There are several configurations for cold water pipe mooring. After studying several options
the concept finalized consists of a floating platform connected to a cold water pipe which
itself acts as mooring for the platform as shown in the Figure 2. Makai Ocean Engineering,
Hawaii, carried out the conceptual design of the seawater systems. The platform assumes a
great significance due to the fact that it houses the entire plant, accommodate the seawater
pumps and the cold water pipe or mooring system. NIOT has carried out studies with the
help of numerical simulation as well as model tests to arrive at the motions and stresses in
the vessel and pipe. The simulation for the barge and pipe combination has been carried
out using the software called Visual Orcaflex. The motion studies for the barge were carried
out using software like TRIBON and WAMIT. In addition to this model studies were carried
out in the model sea basin of size 30m x 30 m x 3 m at the Ocean Engineering Centre in the
Indian Institute of Technology, Madras [3].

A brief comparison of the current design with the previous OTEC plants in the world is given
in the Table 1. It could be noted that as a whole the current system is large and complicated
compared to the previous demonstration plants.

EARLIER INTERNATIONAL OTEC PROJECTS AND LESSONS LEARNED


A complete OTEC system was constructed, deployed and operated successfully at the sea
off shore Hawaii in the US Mini-OTEC program during August –November ‘79. In this first
demonstration of OTEC power with an installed capacity of 50 kW gross, the net power was
low due to fact that the turbine generator could operate with only at 53% efficiency. Also
seawater and ammonia pumps were operated at roughly half the efficiency consuming 35
kW of the gross power produced.

OTEC-1 experiment, sponsored by Department of Energy, USA and conducted by Argonne


National Laboratory, was to simulate OTEC heat exchanger operation. It used shell and
tube titanium heat exchangers. The project gave valuable information about the operation
of heat exchanger, the deployment of cold water pipe and also about the bio-fouling control.
The turbo generator was replaced by a throttle value. It was operational only for four months
in the year 1981 and hence seasonal variations on OTEC system could not be studied.

The Nauru plant in the Pacific region was a shore based plant with Freon-22 as the working
fluid for a Rankine Closed cycle and it had optimal environment for an OTEC Plant. It was
operational for nearly ten months from October 1981. The heat exchangers were of shell
and tube type with titanium as material. The evaporator tubes were coated with sprayed
copper particles to improve the heat transfer co-efficient. Nauru test provided accurate
experimental data on the performance of the power cycle and the construction and
operation of a pilot plant. It provided record for gross and net power production and the
power was supplied to the grid [4].

In 1992 a land based open-cycle experimental plant, with funding from PICHTR, was
designed, built and operated by Dr. Luis A. Vega and his team for a 210 kW gross output.
This was the first open cycle plant after Claude ’s pioneering work. It could produce a
record of 255 kW gross and 103 kW net. This plant provided much valuable information
such as the corrosive nature of seawater, violent outgassing of cold seawater, unstable
synchronous generator output due to the large inertia of the turbine etc. The equipment,
which caused frequent trouble to the system, was the vacuum pump [5].

OTEC ECONOMICS
The OTEC power can be cost effective only if the unit cost of power produced is comparable
with the fossil–fuelled plants. OTEC system can also have other benefits like enhanced
mari culture, desalination or even air conditioning, which might reduce the cost of electricity
generated. As OTEC is capital intensive, Government agencies may provide substantial
initiative in developing the technology. Dr. Luis A. Vega has done extensive work on OTEC
economics for open cycle plants and closed cycle plants [6].

For small plants of 1 MW range the unit power generation cost is considerable compared to
other conventional energy sources as shown in the Table 2. The co-production of fresh
water along with power is to be considered for the estimation of unit cost for OTEC plants in
islands [7]. It is apparent from the study of Dr. Vega that OTEC is economical and
production cost is comparative for higher range of plants. The unit cost of electricity is
estimated for Indian conditions for a range of 1 MW to 100 MW as shown in Table 3
adopting Dr. Vega’s calculation procedure. It could notice that OTEC plants of 100 MW
range are competitive with other conventional energy sources such as coal or hydel power
plants. In comparison with other renewable energy sources such as photovoltaics and
windmills OTEC stands lower for unit investment cost as shown in Figure 3. There are steep
cost improvements for these energy sources. The learning rate (the pattern of diminishing
costs with increasing experience) is nearly 20% for photovoltaics and windmills. The same
result can be expected for OTEC in future with increase in experience and development of
technology.

CURRENT ISSUES AND FUTURE PLANS

It is postulated that most of the future commercial OTEC plants are closed-cycle, floating
plants of 10-50 MW range. But plants of 200-400 MW range are also feasible and
economically more attractive. The commercial plants should be proceeded by demonstration
plants of smaller range for power cycle optimization and also for operational information.
The design, development and operation of a power system in a hostile sea environment is a
great challenge.

The capital cost of the plant is depending much on the heat exchanger cost and hence any
improvement in the performance in this single component is an added advantage. Attempts
are to be done to find out a proven technology for heat exchangers in seawater conditions
with higher heat transfer co-efficient for considerable period of time. The design, fabrication
and deployment of seawater system in the environment of the sea is a matter of
considerable attention. New materials for the cold water pipe is to be developed to
withstand the marine conditions and also for easy fabrication and deployment. The design
of the barge also requires care so as to position the seawater pumps for the required Net
Positive Suction Head (NPSH). The equipment and the piping system are to be assembled
on the barge such a way that the static head and the minor losses are the least. Bio fouling
on the warm water circuit and the release of the dissolved gasses in the cold water circuit is
a problem to be attended for a considerably long period. As the floating plants are away
from seashore under- water power transmission to the land is an area needed further study.
After the completion of testing of the 1 MW OTEC plant, NIOT plans to shift the same plant
to the Andaman & Nicobar Islands for power generation. This will be a stepping stone for
the proposed 10-25 MW range shore mounted power plants. The experience from 1 MW
floating OTEC plant could be scaled up for the construction of 100 MW range commercial
plants in the nearby future.

CONCLUSIONS
It has been assessed that by the year 2010 about one thousand OTEC plants will be
installed of the range 1-100 MW [8]. Now there is a considerable interest in different parts of
the world though there was sluggishness in OTEC research during 1985-1995 period due to
the fall in oil prices. The key problem is now no longer technological or commercial, but the
establishment of reliability and confidence. There is an absolute necessity to build
demonstration plants representing the nature of future commercial plants. The
demonstration of 1 MW Indian OTEC program is expected to contribute in a large way to
provide this confidence to the future.

REFERENCES
1. Uehara. H, and Ikegami Y, “Optimization of a closed cycle OTEC system ”, ASME
Journal of Solar Energy Engineering, Vol. 112, No.4, pp. 247 – 256 (1990)
2. R. Abraham et al, “Analysis of Power Cycle for 1 MW Floating OTEC plant ”, Accepted
paper for IOA ’99 Conference IMARI (1999)
3. P. Jalihal et al, “Analysis of Integrated CWP / Barge System for 1 MW OTEC plant ”,
Accepted paper for IOA ’99 Conference, IMARI (1999)
4. Avery, W. H. and Wu, Renewable Energy from the Ocean – a guide to OTEC ”, Oxford
University Press, pp. 280 (1994)
5. Luis A. Vega and Donald E. Evans “Operation of a Small Open Cycle OTEC
experimental facility”, Renewable Energy Technologies, pp. 93 – 117 (1992)
6. Luis A. Vega, “Economics of Ocean Thermal Energy Conversion ”, Ocean Energy
Recovery, pp. 152-181 (1992)
7. George Hagerman, “Wave Power Economics”, Ocean Energy Recovery, pp. 152-181
(1992)
8. Lennard. D.E, “Ocean Thermal Energy Conversion, “ IOA News Letter Vol. 10, No.2 /
Summer, pp.3(1999)
vapor Turbine Generator
Mist
Separator
 

Evaporator
Condenser
Water to
the sea
Cold water
Water
 from 800 -1000m
to the depth at 4 - 8 o C
sea

Working Fluid
WW Pump CW
Warm water Pump Pump
from sea surface
at 26-29 o C

Fig. 1 The schematic diagram for Closed cycle OTEC plant

OTEC vessel
POWER PLANT

Surface Buoy

0
Mixed water Warm water
Pipe pendant
7 OUT IN
Cold water
Vessel Bow line
IN
15
Top fitting

22 TRANSFER HOSE
3X 0.70 m

30
OECAN DEPTH (m) (METERS)
COLD WATER PIPE (CWP)
1.0 m OD

Bottom Weight
1000
Anchor chain
Anchor Weight
Bottom Mooring line
Sea Floor Anchor
11000

Fig.2 The Mooring Arrangement for 1MW OTEC Plant


Table 1

Summary of OTEC Demonstration Plants in the World in Comparison with


the Proposed 1 MW OTEC Plant

S.No. Agency/Name Year, Location Power Rating( kW)


Gross Net Cycle Type of plant
1. Claude (France) 1930, Cuba 22 - Open Shore based
2. Mini OTEC (US) 1979, Hawaii 53 18 Closed (Rankine) Floating
3. OTEC-1 (US) 1980, Hawaii 1 MWe - Closed (Rankine) Floating
4. Toshiba & TEPC(Japan) 1982, Nauru, 120 31.5 Closed (Rankine) Shore based
5. NELHA (US) 1992, Hawaii 210 100 Open Shore based
6. Saga University (Japan) 1984, Saga 75 - Closed (Rankine) Lab model
7. Saga University (Japan) 1995, Saga 9 - Closed (Uehara) Lab model
8. NELHA (US) 1996, Hawaii 50 - Closed (Rankine) Floating
9. NIOT, India 2000, Tuticorin 1000 - Closed (Rankine) Floating

Gross Heat Exchangers Cold Water Pipe


Power Area( m2) Turbine Material Inner Dia. Length
(kW) Material Type Evap. Cond. (m) (m)
Radial
Mini 50 Titanium Plate 408 408 in-flow HDPE 0.56 670
OTEC 28,200 rpm

OTEC – 1 1 MWe Titanium Shell 5735 5600 No turbine HDPE 3x1.10 670
& tube each

Nauru 100 Titanium Shell 371 438 Freon Axial HDPE 0.70 945
& tube turbine

Hawaii 210 Concrete FEV - - Vertical HDPE 1.00 2040


& mixed flow
Aluminium DCC 1800 rpm

NIOT 1000 Titanium Plate 3720 3410 Axial HDPE 0.90 1100
4-stage
3000 rpm
Table 2

Comparison of Unit Cost of OTEC with Conventional Energy Sources in Pacific


Region (1990)

Plant capacity Plant Life Capacity factor Annual output Cost of energy
(MWe) (Years) (GWh) (US $/kWh)
Wave 1.5 40 68% 9 0.062 – 0.072
Hydro 1.2 40 48% 5 0.113
Diesel 0.9 20 64% 5 0.126
OTEC 1.256 30 80% 8.8 0.149

Table 3
Estimation of Unit Cost of Electricity from OTEC Power in India (1999)

Power Power Heat Cost of Cost of Mooring Turbine + Total Cost Cost of
Output Output Exchanger cold water barge cost Instn. cost electricity
Gross Net cost pipe Million
(MW) (MW) Million US$ Million US$ Million US$ Million US$ Million US$ US$ US$/kWh
1.0 0.617 1.70 0.69 0.69 2.09 1.16 6.42 0.189
25.0 15.39 44.40 1.74 2.33 3.49 17.44 69.42 0.082
50.0 30.88 878.00 2.67 4.65 4.65 34.48 134.67 0.079
100.0 64.23 1526.00 4.65 9.30 5.81 69.76 242.10 0.068

1 MW OTEC

Fig. 3 The capital cost for 1 M W OTEC plant in comparison with


other renewable sources.
( Nebojsa et al., Global Energy Perspectives,1998, p.50)