Sie sind auf Seite 1von 28

for Electrotherapy

3-1-8 Sakae-cho, Kawaguchi-shi, Saitama 332-0017, Japan


TEL: 81-48-254-1031 FAX: 81-48-254-1033
URL: http://www.itocoltd.com/ E-Mail: itocoltd@itolator.co.jp
*Designs and specifications are subject to change without notice.
No.217 C0c000107-1909 Q1910DATA
Company Profile
02 Message from the President

03 Corporate Philosophy

04 There is a reason why people choose ITO

06 Research & Development

08 Superior Quality & Production

10 ITO & Sports

Products
12 Overview of our lineup

16 EU-941 / EU-921

20 ES-5400 / ES-5200

24 TENS 120Z

C O N T E N S 26 US-751

28 US-101L / US-103S

30 OSTEOTRON Ⅳ

32 RSK-600

34 LAZR-207 / LAZR-215 / LAZR-115

36 DIA-TKR 800

38 SW-1000

40 PM-810+ / PM-820
42 HOT MAGNER
HM-2SC-A / HM-101 / HM-202 / HM-204

44 TM-400

46 ES-160

48 ES-130

50 VITER VR-7N

51 Trolley-200

52 Best View Stand


Company Prof ile

Message from the President C orporate Philosophy

Drawing on an outstanding Spirit of Altruism


history and track record to move
toward a new future in physiotherapy Since the foundation in 1916, we have
always kept one corporate philosophy. It
is the“Spirit of Altruism”practiced by
Since our founding in 1916, based on the clear vision of founder Kenji Ito, Kenji Ito, the founder of ITO. Altruism is
ITO has made steady progress in physiotherapy over a long history of thinking and acting for the sake of others
more than 100 years. Our electric physiotherapy devices have earned a more than yourself. It is also known as the
strong reputation for technology, results, and usability, a reputation we practice of Bodhisattva.
believe is rooted in our focus on contributing to society rather than mere
“Contribution to society by providing
sales results—another legacy dating from the time of our founder.
our devises to more people”
. This is our
In its essence, physiotherapy involves not just technical capabilities, but corporate mission and firm management Kenji Ito, Founder
establishing an approach founded on evidence-based medicine (EBM). For philosophy. We dedicate ourselves in
this reason, through ongoing joint research with universities and research pursuit of this our mission forever.
institutions, we’ve moved quickly to demonstrate the evidence and backing
for the efficacy of our products. This represents the foundations of our
vision for mastering physiotherapy and a key element in the support
we provide not just to medical institutions, but to the health of general
consumers and conditioning efforts among athletes. With societies growing
increasingly older around the world, we expect to see the sphere of our
activities continue to expand, based on our grounding in fields in which we
have already achieved significant expertise.

We also plan to continue pursuing research


efforts to ensure comprehensive reliability and
quality controls for our products and to develop
new domains for physiotherapy.

Tsukasa Kurahashi, President

2 3
Company Prof ile

There is a reason A spirit that inspires us to


continue pursuing challenges
why people choose ITO posed by new domains

An international reputation and track record ITO’


s product development history is characterized by an eagerness Head office relocated
2018 to Kawaguchi, Saitama,
to tackle the challenges of miniaturization, sophisticated features, and Japan

accumulated over 40 years in 100 countries high performance. This spirit emerges from our founder’
s vision—to
2017
ITO Manufacturing Vietnam
Co., Ltd. established in Hanoi,
Vietnam
help people live healthier lives by broadening the range of therapy

Since our founding in 1916, alongside its own research and development, ITO has
devices available for use at home. 2016 100th anniversary

US-101L / US-103S, a new style


sought out and adopted technologies from around the world to design numerous Since successfully miniaturizing shortwave therapy devices
2010 in portable ultrasound therapy
systems, launched
physiotherapy devices. Drawing on this legacy, we launched full-fledged international about 80 years ago, ITO has continually striven to make our
90th anniversary of founding
expansion efforts in the 1970s and opened offices in China and Vietnam during the devices as compact as possible while retaining the features and 2006 celebrated US-750 wins 2006 iF
Design Award
1990s. Since then, we’
ve rapidly grown our businesses in Asian markets. performance of larger therapy devices. Products born from
our unique expertise, including portable ultrasound therapy 2005 EU-940 wins 2005 iF Design
Award
In 1996, we began exhibiting in MEDICA, in Dusseldorf, Germany, the world’
s largest
devices, portable interferential electrotherapy devices, and
medical device trade show. We’
ve also exhibited in other leading trade shows around
ultracompact hand-carried electrostimulator equipment,
2004 Reliability Control Center
established

the world, including Arab Health in the UAE and CMEF in China.
have been welcomed with wonder in markets around ES-420 and ES-160 win 2003 iF
2003 Design Award
ISO 14001 certification acquired
Our more than 40 years of activities worldwide the world.

have helped build deep-rooted global trust


Grounded in this unique approach and offering
2001 ISO 13485 certification acquired

in ITO. Today, we export our high-quality


advanced features, ITO’
s compact high-
products to more than 100 countries. 1999 ISO 9001 certification acquired

performance products are used today


Hanoi Office opened in Vietnam Trio 300, world’s first
across a wide range of domains, from 1998 miniature multi-mode stimulator, launched
PM-800 Series, world’s first inverter-controlled
microwave therapy unit, launched
rehabilitation to athletic conditioning
and therapy to in-home care. 1994 Shanghai Office opened in P.R.China

1989 Osteotron, Japan’s first bone-growth stimulator, launched


Tsukuba Factory opened

1983 R&D Center opened

1957 Company name changed to ITO Co., Ltd.


Wide range of electrotherapy equipment developed

1934 Japan’s first shortwave therapy unit, developed

1924 “Radio and Experiments” monthly magazine, Japan’s first specialist radio technology magazine,
first published (Now published by Seibundo Shinkosha publishing company)

1916 Tokyo Medical Electric Co., Ltd. founded by Kenji Ito


Japan’s first AC X-ray machine and other devices developed

4 5
Company Prof ile

Advancing joint research with


numerous research institutions

The concept of evidence-based medicine (EBM) has drawn


significant attention in the field of physiotherapy.
Focusing on the significance of EBM, at ITO, we, too, consider
it essential to demonstrate the effectiveness of our products
through scientific and clinical approaches. We constantly
and proactively collect the latest information from academic
associations around the world, including the World Confederation
for Physical Therapy (WCPT). We pursue advanced joint
research with research institutions and physiotherapists in Japan
and around the world, incorporating the results into our products.
Our products have also begun to draw attention in dental field,
and research seeking to demonstrate the efficacy of ultrasound
technology in dental therapy is advancing rapidly.

Pursuing research and development


through multiple development sections

We established a general R&D section in 1983. We strive to develop


devices that will contribute to society, reflecting societal and corporate
needs identified by sales personnel. In recent years, for example, demand
has grown for compact devices in the field of in-home care. We offer
extensive and proprietary expertise in compact, sophisticated, and high-
performance devices with advanced features, a natural result of our
focus on device miniaturization over the years. Building on this track
record, we’
re striving to develop even more advanced products.

Quality certified under


international standards
Research & Development We obtained ISO certification for the first time in 1998.
Since then, we’ve gained certification under numerous
rigorous international standards, including ISO 13485
(Medical devices – Quality management systems) and ISO
Developing highly reliable and effective products based on the latest 14001 (Environmental management systems). We remain

information and comprehensive EBM dedicated to pursuing new possibilities in physiotherapy


by strengthening not just our technical capabilities, but the
reliability of our products. In this way, we seek to continue
delivering products that contribute to society.

6 7
Company Prof ile

One-person cellular production system


improves quality and efficiency

In 2010, we adopted a one-person cellular production system under which


each product is assembled, inspected, and packed by the same individual.
Under this system, which is especially well-suited to producing a large
variety of products in small lots, each worker handles all aspects of
the production line, strengthening his or her sense of responsibility
and improving skills dramatically. The system has also been highly
successful in terms of work efficiency.

Rigorous quality controls with


advanced testing equipment

To implement even more thorough quality controls, the


Reliability Control Center established at the Tsukuba Factory
in 2004 is fully equipped with some of the industry’
s most
advanced testing equipment, including intelligent load testing
robots, thermal shock chambers, low temperature thermo-
hygrostats, hydrophones, vibration testers, drop impact testers,
bending testers, micro focus X-ray inspection systems, and
photomicroscopy systems. Before, we had outsourced quality
control; now, with these in-house facilities, we are capable of
applying maximum loads to each part and implementing even
more thorough testing. We carry out repeated and rigorous
testing to maintain reliable quality for the physical therapy
devices used not just in medical care, but in homes.

Establishing traceability for thorough


product control

Superior Quality & Production


Stressing thorough traceability for each and every product, we maintain a
structure that makes it possible to precisely ascertain information on every
aspect of production, from the parts used to make a product through the
assembly process and the shipping route. In the rare event of a product
defect, this makes it possible to verify the causative factors from multiple
angles. Since this approach can also be used to clearly ascertain information
Producing trusted devices backed by advanced testing and ranging from production records to the number of years for which each

inspection functions product has been in use, it allows swift response to any problems with
products used for extended periods.
By delivering high-quality products at all times, we strive to earn the trust
of our customers and to reward the high regard in which they hold us.

8 9
Company Prof ile

ITO & Sports

The ITO brand: A leader in Quality and technologies recognized by


athletic conditioning in Japan athletes worldwide

For some 20 years, ITO has pursued efforts to support Today, ITO’
s initiatives in support of athletic endeavor extend around the world.
treatment and conditioning for athletes through Brazil’
s Sao Paulo FC, Chonburi FC in the Thai Premier League, Balmazújvárosi FC
physiotherapy. Today, thanks to the conditioning support in Hungary professional football clubs have formally adopted ITO’
s physiotherapy
we provide in numerous international competitions devices, which they use to optimize the health and conditioning of their athletes. Our
and our track record with many professional sports palm-sized ultrasound devices in particular have earned a sterling reputation for
franchises, including soccer and baseball teams, the ITO enabling conditioning away from team training centers.
name is known throughout the Japanese sports world. Our treatment devices are widely used not just by sports teams, but hospitals,
We’
ve been designated an official sponsor or supplier rehabilitation centers, and other facilities around the world, supporting athletes
for more than 20 athletic associations and teams, seeking to recover quickly from injuries. As requested by the Ministry of Culture,
including the All Japan Judo Federation, the Japan Sports and Tourism of Vietnam, we donated our devices to support the athletes on
Cycling Federation, the Japan Association of Athletics that nation’
s national teams. We have also hosted seminars on treatment methods
Federations, and the Japan Wheelchair Tennis at the Vietnam Sports Hospital. In these ways, our treatment devices today play
Association. major roles on the sports scene worldwide.

10 11
O ver view o f o u r lineup
Ultrasound Therapy

Combination Therapy

US-751 US-101L / US-103S


Multi-Frequency Ultrasound Palm-sized Ultrasound

EU-941 P.26 P.28

Multi-Channel Electrotherapy /
Ultrasound Combo
P.16 LIPUS Therapy (for Bone Growth) Shockwave Therapy

EU-921
Multi-Channel Electrotherapy /
Ultrasound Combo
P.16
RSK-600
Radial Shockwave
P.32

OSTEOTRON Ⅳ
Electrotherapy Ultrasound Bone Growth
Stimulator
P.30

TENS 120Z
Dual Channel TENS
P.24 High Pawer Laser Therapy Radio Frequency Therapy

ES-5400
Multi-Channel Electrotherapy Unit
P.20

ES-5200 LAZR-207 / LAZR-215 / LAZR-115 DIA-TKR 800


Multi-Channel Electrotherapy Unit High Power Laser Radio Frequency
P.20 P.34 P.36

12 13
O ver view o f o u r lineup
Electroacupuncture

Traction Therapy

Shortwave Diathermy Microwave Diathermy

ES-160
6-channel Programmable
Electroacupuncture
P.46

TM-400
Powered Traction Unit
P.44
ES-130
3-channel Palm-sized
Electroacupuncture
P.48

SW-1000 PM-810+ PM-820


Pulsed & Continuous Shortwave Microwave Therapy Microwave Therapy Others
P.38 P.40 P.40

Heat Therapy with Magnetic Fields and Vibration

HOT MAGNER
Heat Therapy Unit with
Magnetic Field and Vibrations
P.42

VITER VR-7N Best View Stand


Professional-use Vibrator Triangular Tilt Stand
P.50 P.52

Trolley-200
Mobile Cart
P.51

HM-101 HM-2SC-A HM-202 HM-204

14 15
EU-941 / EU-921
Current Details
Combination Therapy

Combination Therapy
Maximum
Current Mode Waveform image Output mode Frequency
amplitude (peak)

Multi-Channel Electrotherapy / Ultrasound Combo Output voltage

CH1 Output
voltage Output
IF-4 Constant, Sweep 100voltage
mA 1–250 Hz
CH2

Output voltage
Output voltage
CH1 Output
CH1 Output voltage Output
voltage Output voltage
voltage
IF-2 Output voltage
Constant, Sweep 100 mA 1–250 Hz
CH2
CH2 CH1 Output
voltage Output
Output voltage Output voltage voltage

CH1 CH1
Output Output
CH2
voltage voltage Output Output
voltage voltage
Output voltage

CH1 Output CH2 Output


CH2 Output
voltage Output
voltage
voltage Surge Independent, Surge
voltage
Output
EMS 100voltage
mA 20–250 Hz
Output
Output voltage
voltage
Co-Cont, Surge Alternate
CH2
CH1
CH1 Output
Output (Alternate polarity)
voltage
voltage Output
Output
Output voltage voltage
voltage

CH1 Output
CH2
CH2
voltage Output
voltage
Output
Output
Output voltage
Output voltage
voltage Output
CH2 voltage OutputSurge Independent, Surge voltage
Russian voltage
100 mA 2.5 kHz
EU-941 (Alternate polarity)
Co-Cont, Surge Alternate
(Alternate polarity)

Output
Output Output
Output
voltage voltagevoltage Output
voltage Output
voltage voltage
Output
Output voltage
voltage Output
(Alternate polarity)polarity)
(Alternate
Output
Output
voltage Constant,
voltage Sweep, Burst,
voltage High Voltage Output Continuous DF
voltage
Output Surge Independent, Surge
Output Output 600 mA 0.5–200 Hz
(HV) (Alternate polarity)
voltage voltage voltage

(Alternate polarity)
Co-Cont, Surge Alternate
Intermittent
Output
Output
Output voltage
Output
Output voltage
voltage
voltage
voltage Output
Output MF
(Alternate polarity) voltage
voltage
Output voltage Output
voltage
Output
Output voltage CH1 Output
voltage Output
(Alternate
(Alternate polarity)
Continuous polarity) DF
Constant, Sweep, Burst,
Continuous
voltage DF Output
voltage
voltage Output
Output
TENS Surge Independent, Surge 100 mA 0.5–250 Hz
Output
Output Output Output voltage voltage
voltage
voltage
voltage CH2 voltage
CP
(Alternate polarity)
Intermittent
Co-Cont, Surge Alternate
Intermittent
Triangular wave
Output
voltage
Output
Output Continuous DF
voltage
Output
voltage Output MF
Output voltage Output
(Alternate polarity)
voltage MF voltage voltage
(Alternate polarity) Output
Output Continuous voltage DF
voltage Intermittent
Output Output CP-ISO Output
Surge wavevoltage
Output Output
voltage voltage
voltage voltage
Continuous
MicrocurrentDF Continuous Output

EU-921
DF MF
voltage Intermittent
Output Output
Output voltage
Output
(Alternate polarity)
Output Output Constant Output
CP 750 μA 0.2–400 Hz
voltage
voltage (MCR) voltage
voltage CP voltage Output voltage
Output
Output Triangular voltage
wave voltage
Intermittent Triangularwave
Triangular wave voltage MF
Intermittent LP
Output
Output voltage
(Alternate polarity) Output
CH1 Output
Output voltage Output Output
voltage Output
Output

voltage
voltage Output
voltage voltage
voltage voltage

MF voltage CP
CH2
(Alternate polarity) MF Output Output
Output Output Triangular wave
(Alternate polarity) voltage CP-ISO
voltage
voltage Continuous
Continuous
voltage CP-ISO DF
DF Output

Combination therapy can be applied by providing electrotherapy and ultrasound


Output Surge wave
Surge wave Output voltage
Output
Output Output voltage Output voltage
Output
Output Rectangular wave voltage Output voltage
Output Rectangular wave
Output voltage
voltage
voltage Output
voltage
voltage Output voltage
voltage voltage RS
CH1
Output CP

therapy simultaneously, providing ver y efficient therapy.


Output
voltage
voltage
Output
(Alternate
Outputpolarity)
Continuous
GalvanicDF Continuous, Interrupted 20 mA 0.95–15.8 Hz
voltage
voltage Output Output
CH2 Intermittent
Intermittent voltage
Triangular wave CP-ISO
voltage
Output CP Surge wave voltage
Output Output Output
voltage Output
Output
Triangular wave

47 effective clinical programs are installed to our combination unit. You can simply
voltage
Output voltage
voltage Triangularwave
Triangular wave CP OutputOutput LP
voltage voltage
voltage LP
voltagevoltage
Output
Output
voltage
Output
voltage
Output Output
voltage Output
Output MF
MF
Output
Intermittent
Output Triangular
voltage wave voltage
(Alternate
(Alternate polarity)
polarity) voltage voltage

choose the area to be treated from Human Body Diagram.


voltage
voltage (Alternate polarity)
Output
Output
Output
Output wave
Triangular
voltage
voltage CP-ISO
voltage LP
voltage Surge wave
MFCP-ISO Output

The BNR of EU-941 and EU-921 is 2.4 to 4.6 (IEC standards), a significantly low
Output Output
(Alternate polarity) Surge wave Rectangular wave
voltage voltage voltage
Rectangular wave Output
Output Rectangular
Outputwave
RS
Output
Output voltage Rectangular wave
voltage voltage
voltage Output
Output
voltage RS CP-ISO voltage
Output
Output Output

ratio. Low beam non-uniformity ratio prevents hot spots and tissue damages.
voltage Surge
voltagewave
Output Output voltage
Output
voltage
Faradic Output
Surge Independent 70 mA 20–250 Hz
(Alternate polarity)
CP
CP voltage
voltage voltage voltage
Output
Rectangular wave Output
Output Rectangular wave
Triangular
Triangular
Triangular
voltage wave wave
wave voltage
voltage RS
Continuous
Output
DF
LP
Triangular wave Output Output Output
Output
voltage
LP voltage
voltage
Output
Output
Output
voltage
Output Output
CP Intermittent voltage voltage voltage
Output Output voltage
voltage
voltage
Output
Output
voltage voltage
voltage Triangular wave
Triangular wave MF
Continuous
(Alternate polarity)
voltage DF
Output
voltage LP
Output Output Output
Output

Features
Output
Output CP-ISO
CP-ISO voltage voltage
voltage voltage
voltage
voltage Continuous DF Surge
Surge wave wave CP
Output
Rectangular wave Output Output
Output
Rectangular wave
Output Output
Rectangular wave voltage
Rectangular wave
voltage voltage
Triangular wave voltage
voltageIntermittent
voltage
Intermittent
RS Output
Output
Output
voltage
RS
Output
4 or 2 independent electrotherapy channels Constant current / constant voltage modes Output Output Output
voltage
CP-ISO voltage
voltage
voltage voltage Output
Output Output
voltage
DiadynamicOutput DF, voltage
MF, CP, CP-ISO, LP, RSMF 70 mA 50 Hz or 100 Hz
MF CP-ISO
Output
Surge wave (Alternate polarity)

voltagewave voltage
Output
Surge wave Output
voltage
voltage
Rectangular
voltage
Output

voltage
(Alternate
Rectangular
voltage polarity)
wave
+ 1 ultrasound channel Exclusive vacuum unit available (Optional)
Output
Output RS voltage
Output wave
Triangular
Triangular wave
Triangular wave
voltage CP LP

voltage Output
Triangular wave
voltage
Output
voltage
Output Output
voltage LP
LP
Output
Output
Output voltage voltage
Output
Output
Output
Low BNR (Beam Non-uniformity Ratio) Multi-frequency treatment probes (1 MHz and
voltage

voltage voltage
voltage
voltage Rectangular wave
Output
CP-ISO
Rectangular wave
RS
Surge wave
Triangular wave voltage Output
voltage
Output
voltage
Output

LP CP
voltage
Output

47 effective clinical programs with Human Body 3 MHz)


voltage

Output Output
Output Triangular wave
Triangular wave voltage
voltage voltage LP
Output
Output
Rectangular
Rectangular wave
wave Output
voltage voltage

Rectangular
Rectangular wave
wave
Diagram for over 30 types of pathologies Full-color, 7˝ LCD touch screen RS
RS voltage
Output
Output
Traebert Constant 70 mA 142 Hz
Rectangular wave Rectangular wave
RS

voltage
voltage
Output
voltage Output Output Output
Output Output
Output
voltage
voltage
voltage
voltage
CP-ISO
13 types of frequently used current modes installed 9 languages available (English, German, French,
voltage
voltage
Rectangular wave Rectangular wave Surge wave Output
RS voltage
Output Output
voltage Output voltage
Visual probe contact status Italian, Spanish, Portuguese, Turkish, Vietnamese
Output
voltage voltage

Triangular wave
210 memorable program numbers & Chinese) Output
voltage
LP
Output
voltage

Sequential mode to apply two designated 2 ultrasound probes connectable I/T Curve・AQ Constant 70 mA
I/T Curve: 0.33–0.5 Hz
AQ: 0.33 Hz
therapeutic courses without having to modify unit Selectable coupling sensitivity for ultrasound gel or
Rectangular wave Rectangular wave
RS
Output
voltage Output Output
voltage

parameters medicated gel


voltage

16 17
SU-540 / SU-520<BK>
Specifications
Combination Therapy

Combination Therapy
EU-941 EU-921
Power supply AC 100–240 V, 50/60 Hz
Power consumption 190 VA 140 VA Blow-out System 4 or 2 Channels Vacuum Unit
5 independent 3 independent
Number of channels
(4 for electrotherapy, 1 for ultrasound) (2 for electrotherapy, 1 for ultrasound)
Display Full-color, 7  LCD touch screen
Safety class according to IEC 60601-1 Class I, Type BF
Dimensions 350 (W) × 270 (D) × 145 (H) mm
Weight 4 kg 3.5 kg
Electrotherapy
IF carrier frequency 2 kHz, 4 kHz, 5 kHz, 8 kHz, 10 kHz
Vector sweep (for IF-4) 0°, 15°, 30°, 45°
User-defined protocol memories 120
Pre-programmed clinical protocols 28
Timer Max. 60 min.
Ultrasound
Ultrasound mode Continuous, Pulsed (5%, 10%, 20%, 30%, 40%, 50%)
Ultrasound intensity (max.) Continuous: 2 W/cm2, Pulsed: 3 W/cm2
Ultrasound frequencies 1 MHz, 3 MHz
Pulse frequency 16 Hz, 48 Hz, 100 Hz
User-defined protocol memories 10 (for US) / 80 (for Combo)
Pre-programmed clinical protocols 18 (for US) / 1 (for Combo) SU-540 with EU-941 SU-520<BK> with EU-921
Timer Max. 30 min.
Number of US Probe connections 2
Probe head diameter [Large] 37.5 mm / [Small] 16 mm SU-540 for EU-941 and SU-520<BK> for EU-921, both models adopt blow-out
BNR US Probe head (IEC Standards)
[Large] 1 MHz: 4.6 / 3 MHz: 2.4 vacuum system, and therefore no water reservoir is needed. It is virtually
[Small] 1 MHz: 2.9 / 3 MHz: 2.4
maintenance-free, since dust or moisture does not adhere inside the tube or on the
[Large] 1 MHz: 5.0 cm2 / 3 MHz: 5.0 cm2
ERA US Probe head (IEC Standards)
[Small] 1 MHz: 0.7 cm2 / 3 MHz: 0.5 cm2 connections, resulting in preventing blockages and oxidation.
Probe cable length 2m
Class of protection against Specifications
IPX 7 (US Probe)
ingress of harmful water SU-540 SU-520 <BK>
Power supply AC 100–240 V, 50/60 Hz AC 110, 120 or 220–240 V, 50/60 Hz
110 and 120 V: 70 VA
Power consumption 150 VA
220–240 V: 90 VA
Number of channels 4 independent 2 independent
Ordering Data Dimensions 345 (W) × 315 (D) × 115 (H) mm 345 (W) × 267 (D) × 116 (H) mm
Weight 8.5 kg 8 kg
Standard Kit *Standard kit includes main unit. EU-941 EU-921
Suction pressure 0 to -100 mmHg
012418 Ultrasound Probe (L) 1× 1× 011655 012298
B180534 Electrode Cable (Brown) 1× 1×
Ordering Data
B180535 Electrode Cable (Red) 1× —
012418
B180536 Electrode Cable (Orange) 1× — Standard Kit *Standard kit includes main unit. SU-540 SU-520 <BK>
B180537 Electrode Cable (Yellow) 1× 1× 011771 Electrode Hose (Blue) 2× 1× 011276
011151 Rubber Electrode (M), 60 × 50 mm, 2pcs/pack 4× 2× 011654 011772 Electrode Hose (Gray) 2× 1×
011148 Electrode Sponge A (M), 80 × 65 mm, 2pcs/pack 4× 2× B180537 012399 Vacuum Electrode B (S), ø80 (Gray) 4× 2×
011655 Strap (L), 80 × 1200 mm 4× 2× 012400 Vacuum Electrode B (S), ø80 (Blue) 4× 2×
011148
011654 Strap (S), 80 × 600 mm 4× 2× 011276 Electrode Sponge B (S), ø70, 4pcs/pack 4× 2× 012400 012399
012298 Probe Holder 1× 1× 180562 Power Supply Cord (220–240 V, Type F) or
1× 1× 011771 011772
120612 Ultrasound Gel (250 ml) 1× 1× B180536 180559 Power Supply Cord (110–120 V, Type A)
180562 Power Supply Cord (220–240 V, Type F) or 120612
1× 1× B180534 B180535
180559 Power Supply Cord (110–120 V, Type A) 011151 Optional Accessories *Available to both SU-540 and SU-520 <BK>
012401 Vacuum Electrode B (L), ø100 (Gray) 012401 012402 220279
011277
Optional Accessories *Available to both EU-941 and EU-921 011356 012402 Vacuum Electrode B (L), ø100 (Blue)
012416 Ultrasound Probe (S) 120974 Suction Cup (L), ø100 (Gray) (cup only)
011152 Rubber Electrode (L), 100 × 60 mm, 2pcs/pack 011172 120975 Suction Cup (L), ø100 (Blue) (cup only)
011150 Rubber Electrode (S), 50 × 30 mm, 2pcs/pack 120976 Suction Cup (S), ø80 (Gray) (cup only) 120974 120975
012416 010306
011149 Electrode Sponge A (L), 120 × 80 mm, 2pcs/pack 120977 Suction Cup (S), ø80 (Blue) (cup only)
151157 151083
011147 Electrode Sponge A (S), 70 × 45 mm, 2pcs/pack 151157 Suction Steel Plate (L), ø55
010306 Self-adhesive Electrode, 49 × 49 mm, 4pcs/pack 151083 Suction Steel Plate (S), ø45
010747 Self-adhesive Electrode, 89 × 51 mm, 4pcs/pack 121359 Suction Head
010889 Self-adhesive Electrode, ø32, 4pcs/pack 121360 Suction Head Cup
121360 220278
011356 HV/DC Probe 011147 011277 Electrode Sponge B (L), ø90, 4pcs/pack 121359
011172 MCR (Microcurrent) Probe, 2pcs/pack 220278 Paper Disk (L), ø90, 100pcs/pack 120976 120977
011149 011152 011150 010889 010747
— Vacuum Unit (Please see next page.) 220279 Paper Disk (S), ø70, 100pcs/pack

18 19
ES-5400 / ES-5200
Current Details
Electrotherapy

Electrotherapy
Maximum
Current Mode Waveform image Output mode Frequency
amplitude (peak)

Multi-Channel Electrotherapy Unit Output voltage

CH1 Output
voltage Output
IF-4 Constant, Sweep 100voltage
mA 1–250 Hz
CH2

Output voltage
Output voltage
CH1 Output
CH1 Output voltage Output
voltage Output voltage
voltage
IF-2 Output voltage
Constant, Sweep 100 mA 1–250 Hz
CH2
CH2 CH1 Output
voltage Output
Output voltage Output voltage voltage

CH1 CH1
Output Output
CH2
voltage voltage Output Output
voltage voltage
Output voltage

CH1 Output CH2 Output


CH2 Output
voltage Output
voltage
voltage Surge Independent, Surge
voltage
Output
EMS 100voltage
mA 20–250 Hz
Output
Output voltage
voltage
Co-Cont, Surge Alternate
CH2
CH1
CH1 Output
Output (Alternate polarity)
voltage
voltage Output
Output
Output voltage voltage
voltage

CH1 Output
CH2
CH2
voltage Output
voltage
Output
Output
Output voltage
Output voltage
voltage Output
CH2 voltage OutputSurge Independent, Surge voltage
Russian voltage
100 mA 2.5 kHz
Co-Cont, Surge Alternate
(Alternate polarity)
(Alternate polarity)

ES-5400
Output
Output Output
Output
voltage voltagevoltage Output
voltage Output
voltage voltage
Output
Output voltage
voltage Output
(Alternate polarity)polarity)
(Alternate
Output
Output
voltage Constant,
voltage Sweep, Burst,
voltage High Voltage Output Continuous DF
voltage
Output Surge Independent, Surge
Output Output 600 mA 0.5–200 Hz
(HV) (Alternate polarity)
voltage voltage voltage

(Alternate polarity)
Co-Cont, Surge Alternate
Intermittent
Output
Output
Output voltage
Output
Output voltage
voltage
voltage
voltage Output
Output MF
(Alternate polarity) voltage
voltage
Output voltage Output
voltage
Output
Output voltage CH1 Output
voltage Output
(Alternate
(Alternate polarity)
Continuous polarity) DF
Constant, Sweep, Burst,
Continuous
voltage DF Output
voltage
voltage Output
Output
TENS Surge Independent, Surge 100 mA 0.5–250 Hz
Output
Output Output Output voltage voltage
voltage
voltage
voltage CH2 voltage
CP
(Alternate polarity)
Intermittent
Co-Cont, Surge Alternate
Intermittent
Triangular wave
Output
voltage
Output
Output Continuous DF
voltage
Output
voltage Output MF
Output voltage Output
(Alternate polarity)
voltage MF voltage voltage
(Alternate polarity) Output
Output Continuous voltage DF
voltage Intermittent
Output Output CP-ISO Output
Surge wavevoltage
Output Output
voltage voltage
voltage voltage
Continuous
MicrocurrentDF Continuous DF Output
voltage Intermittent
MF
Output Output
Output voltage
Output
(Alternate polarity)
Output Output Constant Output
CP 750 μA 0.2–400 Hz
voltage
voltage (MCR) voltage
voltage CP voltage Output voltage
Output
Output Triangular voltage
wave voltage
Intermittent Triangularwave
Triangular wave voltage MF
Intermittent LP

ES-5200
Output
Output voltage
(Alternate polarity) Output
CH1 Output
Output voltage Output Output
voltage Output
Output

voltage
voltage Output
voltage voltage
voltage voltage

MF voltage CP
CH2
(Alternate polarity) MF Output Output
Output Output Triangular wave
(Alternate polarity) voltage CP-ISO
voltage
voltage Continuous
Continuous
voltage CP-ISO DF
DF
Output Surge wave Output
Surge wave Output voltage
Output
Output Output voltage Output voltage
Output
Output Rectangular wave voltage Output voltage
Output Rectangular wave
Output voltage
voltage
voltage Output
voltage
voltage Output voltage
voltage voltage RS
CH1 Output
Output CP
voltage
voltage
Output
(Alternate
Outputpolarity)
Continuous
GalvanicDF Continuous, Interrupted 20 mA 0.95–15.8 Hz
voltage
voltage Output Output
CH2 Intermittent
Intermittent voltage
Triangular wave CP-ISO
voltage
Output CP Surge wave voltage
Output Output Output
voltage voltage voltage
Output Output
Output
Triangular wave voltage
Triangularwave
Triangular wave voltage voltage
voltage CP OutputOutput LP
LP
voltagevoltage
Output
Output
voltage
Output
voltage
Output Output
voltage Output
Output MF
MF
Output
Intermittent
Output Triangular
voltage wave voltage
(Alternate
(Alternate polarity)
polarity) voltage voltage

Electrotherapy is a treatment that promotes or represses vital reactions through the


voltage
voltage (Alternate polarity)
Output
Output
Output
Output wave
Triangular
voltage
voltage CP-ISO
voltage LP
voltage Surge wave
MFCP-ISO Output

application of electric stimulation to the neuromuscular system or sensor y ner ves.


Output Output
(Alternate polarity) Surge wave Rectangular wave
voltage voltage voltage
Rectangular wave Output
Output Rectangular
Outputwave
RS
Output
Output voltage Rectangular wave
voltage voltage
voltage Output
Output
voltage RS CP-ISO voltage
Output
Output Output

Intended use is to reduce pain, improve muscle strength, increase joint mobility,
voltage Surge
voltagewave
Output Output voltage
Output
voltage
Faradic Output
Surge Independent 70 mA 20–250 Hz
(Alternate polarity)
CP
CP voltage
voltage voltage voltage
Output
Rectangular wave Output
Output Rectangular wave
Triangular
Triangular
Triangular
voltage wave wave
wave RS

suppress spasms, promote blood circulation and reduce the severity of edema.
Continuous DF voltage
voltage LP
Triangular wave Output
Output
Output Output
voltage
LP voltage
voltage voltage
Output Output Output
CP Output
Output
Output Intermittent voltage voltage
Output Output voltage
voltage
voltage
Output
voltage

28 pre-programmed therapy parameters are installed in ES-5400 and ES-5200 for


Output
voltage voltage
voltage Triangular wave
Triangular wave MF
Continuous
(Alternate polarity)
voltage DF
Output
voltage LP
Output Output Output
Output
Output Output
voltage CP-ISO
CP-ISO voltage voltage

over 20 types of typical pathologies. You can simply choose the area to be treated
voltage
voltage voltage
Continuous DF Surge
Surge wave wave CP
Output
Output
Rectangular wave
Output Output Output Rectangular wave
Triangular wave
Output

Rectangular wave
voltageIntermittent
voltage voltage
voltage
voltage voltage

Rectangular wave RS
Output
Output
Intermittent
RS Output
Output
voltage
Output

from Human Body Diagram.


Output Output
voltage
voltage
Output
voltage
CP-ISO voltage voltage Output Output
voltage
DiadynamicOutput DF, voltage
MF, CP, CP-ISO, LP, RSMF 70 mA 50 Hz or 100 Hz
MF CP-ISO
Output
Surge wave (Alternate polarity)

voltagewave voltage
Output
Surge wave Output
voltage
voltage
Rectangular
voltage
Output

voltage
(Alternate
Rectangular
voltage polarity)
wave Output
Output RS voltage
Output wave
Triangular
Triangular wave
Triangular wave
voltage CP LP

voltage Output
Triangular wave
voltage
Output
voltage
Output Output
voltage LP
LP
Output
Output
Output voltage voltage
Output
Output
Output voltage

voltage voltage
voltage
voltage Rectangular wave
Output
CP-ISO
Rectangular wave
RS
Surge wave
Triangular wave voltage Output
voltage
Output
voltage
Output

LP CP
voltage

Features
Output
voltage

Output Output
Output Triangular wave
Triangular wave voltage
voltage voltage LP
Output
Output
Rectangular
Rectangular wave
wave Output
voltage voltage

Rectangular
Rectangular wave
wave
4 or 2 independent electrotherapy channels Exclusive vacuum unit available (optional) RS
RS voltage
Output
Output
Traebert Constant 70 mA 142 Hz
Rectangular wave Rectangular wave
RS

voltage
voltage
Output
voltage Output Output Output
Output Output
Output
voltage
voltage
voltage
voltage
CP-ISO
28 effective clinical programs with Human Body Constant current / constant voltage modes
voltage
voltage
Rectangular wave Rectangular wave Surge wave Output
RS voltage
Output Output
voltage Output voltage
Diagram Full-color, 7˝ LCD touch screen
Output
voltage voltage

Triangular wave
13 types of frequently used current modes installed 120 memorable program numbers Output
voltage
LP
Output
voltage

Sequential mode to apply two designated 9 languages available (English, German, French, I/T Curve・AQ Constant 70 mA
I/T Curve: 0.33–0.5 Hz
AQ: 0.33 Hz
therapeutic courses without having to modify unit Italian, Spanish, Portuguese, Turkish, Vietnamese
Rectangular wave Rectangular wave
RS
Output
voltage Output Output
voltage

parameters & Chinese)


voltage

20 21
SU-540 / SU-520<BK>
Specifications
Electrotherapy

Electrotherapy
ES-5400 EU-5200
Power supply AC 100–240 V, 50/60 Hz
Power consumption 150 VA 100 VA Blow-out System 4 or 2 Channels Vacuum Unit
Number of channels 4 2
Display Full-color, 7  LCD touch screen
Safety class according to IEC 60601-1 Class I, Type BF
Dimensions 345 (W) × 270 (D) × 145 (H) mm
Weight 2.5 kg 2.3 kg
IF carrier frequency 2 kHz, 4 kHz, 5 kHz, 8 kHz, 10 kHz
Vector sweep (for IF-4) 0°, 15°, 30°, 45°
User-defined protocol memories 120
Pre-programmed clinical protocols 28
Timer Max. 60 min.

Ordering Data
Standard Kit *Standard kit includes main unit. ES-5400 ES-5200
011655
B180534 Electrode Cable (Brown) 1× 1× 011654
B180535 Electrode Cable (Red) 1× 1× SU-540 with ES-5400 SU-520<BK> with ES-5200
B180536 Electrode Cable (Orange) 1× —
B180537 Electrode Cable (Yellow) 1× — B180536
011151 Rubber Electrode (M), 60 × 50 mm, 2pcs/pack 4× 2×
B180537 011148 SU-540 for ES-5400 and SU-520<BK> for ES-5200, both models adopt blow-out
011148 Electrode Sponge A (M), 80 × 65 mm, 2pcs/pack 4× 2×
011655 Strap (L), 80 × 1200 mm 4× 2×
vacuum system, and therefore no water reservoir is needed. It is virtually
011654 Strap (S), 80 × 600 mm 4× 2×
011151 maintenance-free, since dust or moisture does not adhere inside the tube or on the
180562 Power Supply Cord (220–240 V, Type F) or
1× 1× B180534 connections, resulting in preventing blockages and oxidation.
180559 Power Supply Cord (110–120 V, Type A) B180535

Specifications
Optional Accessories *Available to both ES-5400 and ES-5200 011356
SU-540 SU-520 <BK>
011152 Rubber Electrode (L), 100 × 60 mm, 2pcs/pack 011172
011149 Power supply AC 100–240 V, 50/60 Hz AC 110, 120 or 220–240 V, 50/60 Hz
011150 Rubber Electrode (S), 50 × 30 mm, 2pcs/pack
011149 Electrode Sponge A (L), 120 × 80 mm, 2pcs/pack 010306 110 and 120 V: 70 VA
Power consumption 150 VA
220–240 V: 90 VA
011147 Electrode Sponge A (S), 70 × 45 mm, 2pcs/pack
010306 Self-adhesive Electrode, 49 × 49 mm, 4pcs/pack Number of channels 4 independent 2 independent
010747 Self-adhesive Electrode, 89 × 51 mm, 4pcs/pack Dimensions 345 (W) × 315 (D) × 115 (H) mm 345 (W) × 267 (D) × 116 (H) mm
010889 Self-adhesive Electrode, ø32, 4pcs/pack Weight 8.5 kg 8 kg
011356 HV/DC Probe Suction pressure 0 to -100 mmHg
011147
011172 MCR (Microcurrent) Probe, 2pcs/pack
011152
— Vacuum Unit (Please see next page.) 011150 010889 010747 Ordering Data
Standard Kit *Standard kit includes main unit. SU-540 SU-520 <BK>
011771 Electrode Hose (Blue) 2× 1× 011276
011772 Electrode Hose (Gray) 2× 1×
012399 Vacuum Electrode B (S), ø80 (Gray) 4× 2×
012400 Vacuum Electrode B (S), ø80 (Blue) 4× 2×
011276 Electrode Sponge B (S), ø70, 4pcs/pack 4× 2× 012400 012399
180562 Power Supply Cord (220–240 V, Type F) or 011771 011772
1× 1×
180559 Power Supply Cord (110–120 V, Type A)

Optional Accessories *Available to both SU-540 and SU-520 <BK>


012401 Vacuum Electrode B (L), ø100 (Gray) 012401 012402 220279
011277
012402 Vacuum Electrode B (L), ø100 (Blue)
120974 Suction Cup (L), ø100 (Gray) (cup only)
120975 Suction Cup (L), ø100 (Blue) (cup only)
120976 Suction Cup (S), ø80 (Gray) (cup only) 120974 120975
120977 Suction Cup (S), ø80 (Blue) (cup only)
151157 151083
151157 Suction Steel Plate (L), ø55
151083 Suction Steel Plate (S), ø45
121359 Suction Head
121360 Suction Head Cup
121360 220278
011277 Electrode Sponge B (L), ø90, 4pcs/pack 121359
220278 Paper Disk (L), ø90, 100pcs/pack 120976 120977
220279 Paper Disk (S), ø70, 100pcs/pack

22 23
TENS 120Z
Specifications
Electrotherapy

Electrotherapy
Power supply DC 9 V
Number of channels 2

Dual Channel TENS Safety class according to IEC 60601-1 Internally powered equipment, Type BF
Dimensions 61 (W) x 27 (D) x 96 (H) mm
Weight 120 g (without a battery)
Current mode TENS
Output mode Constant, Burst, Modulation
Maximum amplitude 20 mArms
Frequency 2–200 Hz

Ordering Data
Standard Kit *Standard kit includes main unit. Optional Accessories
B120671 Rubber Electrode, 40 × 41 mm, 2pcs/pack, 2x 011148 Electrode Sponge A (M), 80 × 65 mm, 2pcs/pack
8003220 Gel Pad, 40 × 41 mm, 4pcs/pack 010306 Self-adhesive Electrode, 49 × 49 mm, 4pcs/pack
B180376 Electrode Cable, 2x 010747 Self-adhesive Electrode, 89 × 51 mm, 4pcs/pack
260182 Carrying Bag 010889 Self-adhesive Electrode, ø32, 4pcs/pack
NOTE: A battery is not included. B010807 Strap (L ), 45 × 1200 mm
010820 Strap (S), 45 × 600 mm

010306

B180376 010889
010747

8003220 010820
260182
011148

B120671

B010807

TENS 120Z has been sold for over 30 years. As the weight of the unit is less than
200 g and the unit size is ver y compact, you can easily bring it anywhere you like.
You can fix parameters by using the safe-lock lever for safe treatment.

Features
Portable size and weight
Safe-lock lever for control knobs for safe treatment
Longtime seller

24 25
US-751
Specifications
Ultrasound Therapy

Ultrasound Therapy
Power supply AC 100–240 V, 50/60 Hz
Power consumption 85 VA

Multi-Frequency Ultrasound Number of channels 1


Display Full-color, 7  LCD touch screen
Safety class according to IEC 60601-1 Class I, Type BF
Dimensions 290 (W) × 233 (D) × 96 (H) mm
Weight 3 kg
Ultrasound mode Continuous, Pulsed (5%, 10%, 20%, 30%, 40%, 50%)
Ultrasound intensity (max.) Continuous: 2 W/cm2, Pulsed: 3 W/cm2
Ultrasound frequencies 1 MHz, 3 MHz
Pulse frequency 16 Hz, 48 Hz, 100 Hz
Pre-set parameters 42
Timer Max. 30 min.
Number of US Probe connections 2
Probe head diameter [Large] 37.5 mm / [Small] 16 mm
[Large] 1 MHz: 3.0 / 3 MHz: 2.4
BNR US Probe head (IEC Standards)
[Small] 1 MHz: 2.9 / 3 MHz: 2.4
[Large] 1 MHz: 5.0 cm2 / 3 MHz: 5.0 cm2
ERA US Probe head (IEC Standards)
[Small] 1 MHz: 0.7 cm2 / 3 MHz: 0.5 cm2
Probe cable length 2m
Class of protection against
IPX 7 (US Probe)
ingress of harmful water

Ordering Data
Standard Kit *Standard kit includes main unit. Optional Accessories
012297 Ultrasound Probe (L) or 012296 Ultrasound Probe (S)
012330 Ultrasound Probe (L) (Canada version) 012329 Ultrasound Probe (S) (Canada version)
120612 Ultrasound Gel (250 ml)
012298 Probe Holder
080611 Core Filter
180672 Power Supply Cord (220–240 V, Type F) or
180676 Power Supply Cord (110–120 V, Type A) or
180673 Power Supply Cord (110–120 V, only North America, Type B)

Ultrasound therapy is based on sonic energy inaudible to the human ear which
generates micro vibration in body tissues. This vibration contributes to pain relief, 012296

localized increase in blood flow and stimulation of tissue repair. Furthermore, 012298

ultrasound generates thermal changes in the tissues which help to reduce muscle
spasms and decrease joint contractures.
The BNR of US-751 is 2.4 to 3.0 (IEC standards), a significantly low ratio. Low beam 012297 120612 080611
non-uniformity ratio prevents hot spots and tissue damages. You can simply choose
the area to be treated from Human Body Diagram. 42 parameters are pre-set. All the
pre-set parameters can be modified to suit your particular needs.

Features
Full-color, 7˝ LCD touch screen Selectable coupling sensitivity
Low BNR (Beam Non-uniformity Ratio) 8 languages available (English, German, French,
42 pre-set parameters with human body diagram Spanish, Portuguese, Turkish, Swedish & Chinese)
Visual probe contact status 2 ultrasound probes connectable

26 27
US-101L / US-103S
Specifications
Ultrasound Therapy

Ultrasound Therapy
US-101L US-103S
Power supply AC 100–240 V, 50/60 Hz or rechargeable battery (optional)

Palm-sized Ultrasound Power consumption 50 VA 17 VA


Display 1.44  color LCD
Safety class according to IEC 60601-1 Class I / Internally powered equipment, Type BF
Dimensions 134 (H) × 59 (W) × 55 (D) mm 134 (H) × 59 (W) × 60.5 (D) mm
Weight 200 g 190 g
Ultrasound mode Continuous, Pulsed (5%, 10%, 20%, 30%, 40%, 50%)
Ultrasound intensity (max.) Continuous: 2 W/cm2, Pulsed: 3 W/cm2
Ultrasound frequencies 1 MHz 3 MHz
Pulse frequency 100 Hz
Pre-set parameters 5
Timer Max. 30 min.
Probe head diameter 37.5 mm 16 mm
BNR US Probe head (IEC Standards) 3.5 2.4
ERA US Probe head (IEC Standards) 5.0 cm2 0.5 cm2
Probe cable length 1.5 m
Class of protection against
IPX 7 (except for Intermediate box)
ingress of harmful water

Ordering Data
Standard Kit *Standard kit includes main unit. Optional Accessories
US-101L 012608 Battery Charger
012055 Protective Cap for US-101L Probe 012061 Rechargeable Battery (except for North America) or
120612 Ultrasound Gel (250 ml) 012173 Rechargeable Battery (only North America)
012606 AC Adaptor (100−240 V) 012062 Battery Case
012057 Power Supply Cord (220−240 V, Type F) or 012063 Unit Stand
Power Supply Cord 012064 Pouch
180676
(110−120 V, except for North America, Type B) or
180673 Power Supply Cord (110−120 V, only North America, Type B)
012608
*This cord uses along with an AC Adaptor.
US-103S
012058 Protective Cap for US-103S Probe
120612 Ultrasound Gel (250 ml)
012606 AC Adaptor (100−240 V)
Ultrasound treatment is available in both acute and chronic phases for deep and 012057 Power Supply Cord (220−240 V, Type F) or

superficial tissues. Difficult body parts to be treated such as toes or fingers can be treated 180676
Power Supply Cord
(110−120 V, except for North America, Type B) or 012061 012062 012063 012064

by immersing a probe and the body part in water. 180673 Power Supply Cord (110−120 V, only North America, Type B)

The BNR of US-101L / US-103S is 2.4 to 3.5 (IEC standards), a significantly low ratio. *This cord uses along with an AC Adaptor.

Low beam non-uniformity ratio prevents hot spots and tissue damages. As the weight
012606
of these units is less than 200 g and the unit size is very compact, you can easily bring
them anywhere you like. Furthermore, it is possible to use these models in the areas with
012055
unstable supply of electricity if you charge battery in advance.

Features
Easily portable 012058 120612
One-hand operation
Waterproof design
Low BNR (Beam Non-uniformity Ratio)
Rechargeable battery available (optional)
5 pre-set parameters installed (modifiable)

US-101L US-103S

28 29
OSTEOTRON Ⅳ
Specifications
LIPUS Therapy

(for Bone Growth)


Power supply DC 4.8 V (battery) / DC 5 V (AC Adaptor)
Power consumption 8 VA

Ultrasound Bone Growth Stimulator Number of channels 2


Display 3  LCD
Safety class according to IEC 60601-1 Class I / Internally powered equipment, Type BF
Dimensions 98 (W) × 40 (D) × 145 (H) mm
Weight 240 g (without batteries)
Ultrasound mode Pulsed (20% fixed)
Ultrasound intensity (max.) 30 mW/cm2, 45 mW/cm2, 60 mW/cm2 (SATA)

LIPUS Therapy
Ultrasound frequencies 1.5 MHz, 750 kHz (optional)
(for Bone Growth)

Pulse frequency 100 Hz, 1000 Hz


Timer 20 min., 30 min.
Probe head diameter 32 mm
[1.5 MHz] 3.5
BNR US Probe head (IEC Standards)
[750 kHz] 3.0
[1.5 MHz] 3.9 cm2
ERA US Probe head (IEC Standards)
[750 kHz] 3.5 cm2
Probe cable length 0.5 m
Class of protection against
IPX 7 (US Probe)
ingress of harmful water

Ordering Data
Standard Kit *Standard kit includes main unit. Optional Accessories
012096 Ultrasound Probe 1.5 MHz, 2 x 012101 Ultrasound Probe 750 kHz
012097 Probe Retainer with 700 mm Belt, for use with Cast 012102 Probe Retainer with 250 mm Belt, for use with Cast
012098 Probe Retainer with 450 mm Belt, for use with Cast 012103 Extension Belt, 600 mm
012099 Probe Retainer with 470 mm Belt, for use without Cast 012104 Solid Gel Pad , 8pcs/sheet
012609 AC Adaptor (100−240 V)
012057 Power Cable for AC Adaptor (220−240 V, Type F) 012101 012104
012102
120612 Ultrasound Gel (250 ml)
260700 Carrying Bag
NOTE: Nickel metal hydride rechargeable batteries and a charger are not
included. Purchase them locally.

012097
012103
The sound pressure stimulation provided by the LIPUS (Low Intensity Pulsed Ultrasound)
012098
system accelerates the formation and re-union of fractured bone, and contributes to rapid
012099 120612
recovery. LIPUS therapy is also effective to fresh fracture, delayed unions and nonunion.
As OSTEOTRON IV has 2 output channels, simultaneous therapy for multiple areas is
available. Only three-step output control to start treatment. You can easily bring the unit
anywhere you like as the weight of main unit is approx. 300 g and the unit size is very
compact.

Features
012096
2 output channels
Low BNR (Beam Non-uniformity Ratio)
Dual frequency (1.5 MHz and 750 kHz)
Easy probe attachment with exclusive probe retainers
Easily portable 012609 260700
AC or battery operation is available
Simple operation (Only three-step output control to start treatment)
Easy to carry with exclusive carrying case

30 31
RSK-600
Specifications
Shockwave Therapy

Shockwave Therapy
Power supply AC 100–240 V, 50/60 Hz
Power consumption 250 VA

Radial Shockwave Display Full-color, 5.7  LCD touch screen


Safety class according to IEC 60601-1 Class I, Type B
Dimensions 320 (W) × 245 (D) × 130 (H) mm
2 kg (main unit)
Weight
0.95 kg (handpiece)
Output mode Continuous, Burst, Swing
50–200 mJ (almost equivalent to 1–5 bar)
Output power
*Adjustable in step of 10 mJ
Frequency 1–25 Hz
Specific protocols for Bio-stimulant, Analgesic, Anti-inflammatory, Anti-edema, Tension Relief
Pre-programmed clinical protocols For over 60 pathologies
Schockwave technology Compressor–free ballistic radial shockwave with electromagnetic generator

Ordering Data
Standard Kit *Standard kit includes main unit. Optional Accessories
8004461 Handpiece 8004434 Trolley
8004462 Applicator ø6
8004434
8004463 Applicator ø15
8004464 Applicator ø24
8004467 Foot switch
8004468 Silicone cap
8004472 Caliber
8004473 Holder
8004424 Bag

8004461 8004462 8004463 8004464

Shockwave therapy is mainly used for the treatment of muscles, tendons, bones and soft
tissues. Radial shockwaves are high energy acoustic waves. The kinetic energy of the
projectile, created by the electromagnetic generator, is transferred to skin through the 8004468 8004472
applicator of the handpiece. The collision generates shockwaves which diffuse, expanding
radially, through skin and the first layer of tissue below.
The innovative electromagnetic generator of RSK-600 guarantees to generate up to 8004467

5,000,000 shots. The model contains a large interactive database containing over 60
pathologies which guide the operator through the treatment. The model does not need an
air compressor as it applies an electromagnetic system. Because of its compact size, the
device does not occupy much space.

8004473
8004424
Features
5 million shots guaranteed 6 languages available (English, German, French,
Clinical protocols for over 60 pathologies Spanish, Italian & Russian)
3D protocols by phases Compact body for space saving
Innovative swing mode Easy to carry with exclusive carrying case
Unique pulsed “ultra soft” shockwave Exclusive trolley available

32 33
LAZR-207 / LAZR-215 / LAZR-115
Specifications
High Pawer Laser Therapy

High Pawer Laser Therapy


LAZR-207 LAZR-215 LAZR-115
Power supply AC 100–240 V, 50/60 Hz

High Power Laser Power consumption 160 VA


Display Full-color, 5.7  LCD touch screen
Safety class according to IEC 60601-1 Class I, Type BF
Dimensions 320 (W) × 245 (D) × 130 (H) mm
Weight 3 kg
Wavelength 810 nm + 980 nm 1064 nm
Guide light 650 nm (wavelength) / 3 mW (power)
Laser power up to 7 W up to 15 W
Emission mode Continuous (CW), E2C, AntInf, Pulsed, Single Pulse, Burst, Custom
Operation mode Joule, Timer, Trigger Point
Specific protocols for Bio-stimulant, Analgesic, Anti-inflammatory, Anti-edema, Tension Relief
Pre-programmed clinical protocols For over 60 pathologies
Laser class IV

Ordering Data
Standard Kit *Standard kit includes main unit. ScanX system
*ScanX System can be supplied in package only including following items.
8004442 Applicator ø40
— LAZR main unit with ScanX mode
8004441 Applicator ø30
8004442 Applicator ø40
8004447 Foot switch
8004441 Applicator ø30
8004448 Foot switch with Cover
8004447 Foot switch
8004444 Laser Warning Sign
8004448 Foot switch with Cover
8004450 Meter
8004444 Laser Warning Sign
8004446 Safety Glasses
8004450 Meter
8004443 3 Pole Interlock
8004446 Safety Glasses
8004424 Bag
8004443 3 Pole Interlock
8004424 Bag
8004481 Arm
8004482 Conical Applicator ø120
8004483 Conical Applicator ø70
8004442 8004441 8004447
An advantage of laser therapy is its ability to work at deep area, and to resolve the cause of 8004434 Trolley
8004485 5 Pole Interlock
the pathology at its point of origin. This characteristic can be attributed to two properties 8004486 Patient Button
of the laser: wavelength and power. The emission power also increases the effectiveness 8004487 Stay
of the laser, transmitting the beneficial effects to great depth. Different wavelengths have
8004448
different properties in terms of diffusion and absorption by human tissues. 8004444 8004450

As LAZR series has two wavelength modes, you can select suitable one for each
therapeutic objective. Pathology Library includes over 60 pathologies with relative 8004446
8004442 8004441 8004447 8004448

interactive protocols, sub-divided by phase.


ScanX mode (automatic emission mode) is available with only ScanX System Package. It 8004443
8004424
is possible to use the mode with one simple command. Thanks to this innovative function, 8004443
you don’t have to stay by patient all the time during treatment. Please optimize your Optional Accessories 8004444 8004450 8004446
8004434 Trolley
valuable time.
8004434 8004481
8004424

Features
The 2 wavelength modes, COMBINATION 6 languages available (English, German, French,
(810 + 980 nm) and SINGLE (1064 nm) Spanish, Italian & Russian) 8004482
8004483

Effective 7 emission modes (Pulsed, Single Pulse, Easy to carry with exclusive carrying case 8004434

Continuous Wave, Custom, AntInf, Burst and E2C) Exclusive trolley available
8004485
Innovative patented “E2C” emission mode installed ScanX mode (automatic emission mode) available
Clinical protocols for over 60 pathologies with only ScanX System Package
Specific protocols for 5 main effects 8004486 8004487

34 35
DIA-TKR 800
Specifications
Radio Frequency Therapy

Radio Frequency Therapy


Power supply AC 100–240 V, 50/60 Hz
Power consumption 160 VA

Radio Frequency Display Full-color, 5.7  LCD touch screen


Safety class according to IEC 60601-1 Class I, Type BF
Dimensions 320 (W) × 245 (D) × 130 (H) mm
Weight 1.8 kg
Output power 120 W effective (350 Wpp)
Operation mode Joule, Timer, Adjustable Pulsed, AV (Automatic, Automatic Pulsed, Manual)
Frequency 470–560 kHz
Emission mode Capacitive and Resistive
Pre-programmed clinical protocols For over 60 pathologies

Ordering Data
Standard Kit *Standard kit includes main unit. Optional Accessories
8004411 Handpiece 8004431 Round Plate ø35
8004412 Common Cable 8004432 Round Plate ø60
8004413 Triax Cable 8004433 Round Plate ø80
8004419 Patient Button 8004434 Trolley
8004414 Conductive Creme
8004415 Creme Diffusor 8004434
8004416 Flat Plate ø35
8004417 Flat Plate ø60
8004431
8004418 Flat Plate ø80
8004421 Common Plate 150 x 200 mm
8004420 Common Plate 180 x 230 mm
8004422 Adhesive Plate 25pcs/box
8004423 Adhesive Electrode 120pcs/box
8004432
8004424 Bag

We use innovative Switching Real Time technology for DIA-TKR 800: thanks to this 8004433
important step forward in technology, it is possible to reach high power and increased
8004411 8004412 8004413 8004419
therapeutic performance. Switching Real Time technology has also allowed the dimensions
of the device to be reduced.
DIA-TKR 800 is compact, high power, and easily transportable. This important innovation
has been made possible by the know-how which we have gained over the years, designing 8004416
8004417 8004418
and building the components of its machines according to therapeutic results. The model 8004414
features a single handpiece for both capacitive and resistive modes. With one simple
command, it is possible to change from one mode to the other: simplicity and functionality
in cutting-edge therapeutic technology.
8004421 8004422
8004420

Features
Single handpiece for both Capacitive and Resistive modes
AV mode (Automatic Mode and Automatic Pulsed Mode)
Clinical protocols for over 60 pathologies 8004423
8004415 8004424
Bio-transfer system
Adjustable pulsed mode for effective thermal control
6 languages available (English, German, French, Spanish, Italian & Russian)
Easy to carry with exclusive carrying case
Exclusive trolley available Single Application Handpiece

36 37
SW-1000
Specifications
Shortwave Diathermy

Shortwave Diathermy
Power supply AC 100–240 V, 50/60 Hz
Power consumption 1 kVA

Pulsed & Continuous Shortwave Display Full-color, 7  LCD touch screen


Safety class according to IEC 60601-1 Class I, Type BF
Dimensions 470 (W) × 470 (D) × 940 (H) mm (main unit)
Weight 38 kg (without electrodes)
Output mode Continuous, Pulsed (3 in 3, 2 in 3 or 1 in 3)
1000 W (peak) in pulsed mode
Maximum output power
400 W (mean) in continuous mode
Frequency 27.12 MHz
Pulse frequency 5 Hz, 10 Hz, 20 Hz, 30 Hz, 50 Hz, 80 Hz, 100 Hz, 200 Hz, 400 Hz, 600 Hz, 800 Hz
Pulse width 20 μs, 40 μs, 65 μs, 100 μs, 200 μs, 400 μs
Timer Max. 30 min.

Ordering Data
Standard Kit *Standard kit includes main unit.
8004809 100 mm Capacitive Electrodes and Cables, 2pcs/pack
8004808 Output Tester

8004809

8004808

Screens

Shortwave therapy uses a frequency of 27.12 MHz. The electric-fields methods used
in shortwave therapy comprise Capacitive (Condenser-field) and Inductive (Coil-field)
methods. Shortwave in the form of electromagnetic radiation is absorbed by the body,
generating molecular rotational movement and displacement current within the body,
in accordance with the Maxwell equation. The unique wave motion of electromagnetic
radiation propagates deep inside the body allowing tissue to be heated.
SW-1000 is pre-programmed with 10 therapy parameters for typical pathologies. You can
use both continuous and pulsed output modes in one unit. 1000 W in pulsed mode and
400 W in continuous mode can be performed as maximum output power.

Features
Continuous and pulsed modes selectable Full color large touch screen interface
10 effective clinical programs High power output (1000 W in pulsed mode and
16 memorable program numbers 400 W in continuous mode)
3 types of pulsed output modes selectable Auto-tuning function installed

38 39
+
PM-810 / PM-820
Specifications
Microwave Diathermy

Microwave Diathermy
PM-810+ PM-820
Power supply AC 110, 220 or 230 V, 50/60 Hz

Microwave Therapy 110 V: 850 VA 110 V: 880 VA


Power consumption 220 V: 760 VA 220 V: 820 VA
230 V: 770 VA 230 V: 880 VA
Number of channels 1 2
Safety class according to IEC 60601-1 Class I, Type B
Dimensions 330 (W) × 395 (D) × 790 (H) mm (main unit)
Weight 28 kg (without applicator) 36 kg (without applicator)
Output mode Continuous, Pulsed Pulsed
Continuous: 100 W
100 W mean power, a fixed peak
Maximum output power Pulsed: 100 W mean power, a fixed peak
power of 1500 W
power of 1500 W
Frequency 2450 MHz
Timer Max. 30 min.
Rectanglar Applicator: 293 × 150 mm
Applicators
Circular Applicator: ø170

Ordering Data
Standard Kit *Standard kit includes main unit.
PM-810+
012040 Rectangular Applicator with HF Cable, 290 mm in width
151196 Tool for Tightening Arm Joint
180350 Power Supply Cord (220−240 V, Type F) or
180349 Power Supply Cord (110−120 V, Type A)
PM-820
012040 Rectangular Applicator with HF Cable, 290 mm in width
012041 Circular Applicator with HF Cable, 170 mm in diameter
151196 Tool for Tightening Arm Joint
180350 Power Supply Cord (220−240 V, Type F) or
180349 Power Supply Cord (110−120 V, Type A)

PM-820

012040 012041
PM-810+

151196

Microwave diathermy is classified as high frequency therapy which utilizes electromagnetic


waves. As the energy from these waves is absorbed in high water content such as muscle
and will make them warm, microwave diathermy will be practical and suitable for
reduction of pain, relaxation of muscle and improvement of range of motion and treatment
for pathologies in the muscles. Treatment Images
The smaller dimensions of PM-810+ and PM-820 do not occupy much space of treatment
room. You can easily switch between Pulsed and Continuous modes by pressing button on
the operating panel (PM-810+). PM-820 has ALTERNATE MODE for the irradiation of two
treatment areas simultaneously with effortless operation.

Features
Effortless transition between pulsed and Alternate mode installed (PM-820 only)
continuous mode (PM-810+ only) Space-saving design
Two types of applicators supplied as standard kit
(PM-820 only)

40 41
HOT MAGNER Specifications
Heat Therapy with Magnetic Fields and Vibration

Heat Therapy with Magnetic Fields and Vibration


HM-2SC-A HM-101 HM-202 HM-204

HM-2SC-A / HM-101 / HM-202 / HM-204


Power supply AC 110 or 220 V, 50/60 Hz
Power consumption 340 VA 200 VA 320 VA 640 VA
Number of channels 2 1 2 4
Safety class according to
Heat Therapy Unit with Magnetic Field and Vibrations IEC 60601-1
Class I, Type B

Dimensions 450 (W) × 300 (D) × 205 (H) mm 260 (W) × 225 (D) × 125 (H) mm 440 (W) × 300 (D) × 320 (H) mm 440 (W) × 300 (D) × 320 (H) mm
Weight 12 kg 5 kg 17 kg 19 kg
Selectable temperature 40℃ , 50℃ , 60℃ or 65℃ 35℃ , 43℃ , 50℃ or 60℃
Micro-vibration
50–120 64, 71, 127
(times per sec.)
Timer Max. 30 min.

Ordering Data
Standard Kit *Standard kit includes main unit. Optional Accessories
HM-2SC-A Super Magner Pack MS (4PIN) 390 × 200 × 25 mm
8004255
Super Magner Pack LX (4PIN) 470 × 200 × 25 mm (w/pack cover)
8004269
(w/pack cover), 2x Super Magner Pack OS (4PIN) 390 × 390 × 25 mm
8004244
8004222 Strap (S), 50 × 1200 mm, 2x (w/pack cover)

8004223 Magnetic Detector Super Magner Pack ES (4PIN) 390 × 310 × 25 mm


8004256
(w/pack cover)
HM-101
Super Magner Pack OX (4PIN) 390 × 390 × 25 mm
Super Magner Pack LX (4PIN) 470 × 200 × 25 mm 8004266
Standard 2-channel unit 8004269 (w/pack cover, for only HM-2SC-A)
(w/pack cover)
HM-2SC-A 8004222 Strap (S), 50 × 1200 mm 8004267
Super Magner Pack EX (4PIN) 390 × 310 × 25 mm
(w/pack cover, for only HM-2SC-A)
A cart is optional. 8004223 Magnetic Detector
Super Magner Pack MX (4PIN) 390 × 200 × 25 mm
HM-202 8004268
(w/pack cover, for only HM-2SC-A)
Super Magner Pack MS (4PIN) 390 × 200 × 25 mm Super Magner Pack LX (4PIN) 470 × 200 × 25 mm
8004255 8004269
(w/pack cover), 2x (w/pack cover)
8004222 Strap (S), 50 × 1200 mm, 2x Super Magner Pack KX (4PIN) 430 × 420 × 25 mm
8004270
4-channel unit 8004223 Magnetic Detector (w/pack cover, for only HM-2SC-A)
HM-204 Super Magner Pack WX (4PIN) 210 × 200 × 25 mm
HM-204 Super Magner Pack MS (4PIN) 390 × 200 × 25 mm
8004271
(w/pack cover, for only HM-2SC-A)
A cart is optional. 8004255
(w/pack cover), 2x Magner Pack N (4PIN) 500 × 130 × 25 mm
8004207
Super Magner Pack OS (4PIN) 390 × 390 × 25 mm (w/pack cover)
8004244
(w/pack cover), 2x 8004213 Pack Cover for L, M, N, MS
8004221 Strap (L), 100 × 1200 mm, 2x 8004219 Pack Cover for O, OS
Deluxe 2-channel unit
Compact 1-channel unit 8004222 Strap (S), 50 × 1200 mm, 2x 8004221 Strap (L), 100 × 1200 mm
HM-202
A cart is optional. HM-101 8004223 Magnetic Detector 8004222 Strap (S), 50 × 1200 mm
8004220 Strap for Magner Pack E, 50 × 1200 mm
8004239 Cart for HM-202, HM-204
8004245 Cart for HM-2SC-A

An alternating pulsed magnetic field (PRMF) is used to vary the strength and direction of 8004223 Magnetic Detector
8004280 6P4P/4P6P Conversion Cable
the magnetic flux with a constant rhythm, in order for the magnetic flux to act effectively
in balance with the body. Magnetic flux alters the electric potential of nerves and cells,
providing pain-relief effects and healing of injured tissue. A semi-Markov series is used to
generate a pleasing “1/f fluctuation” biological rhythm, which ensures even more pleasant
treatment.
HOT MAGNER series has various types and sizes of packs to suit the treatment on each
part of body; low back, knee, shoulder, thigh, etc. Comparing with conventional hot pack
system, you do not need to spend much time in maintenance. Since the pack is always dry
and can be applied from on garments, you are only required to do visual check on the unit
before starting treatment.

Features
Three types of energies in one device Easy temperature setting
Time saving working procedure Various types of exclusive packs can be supplied
Easy to keep hygienic Exclusive carts available (Optional)

42 43
TM-400
Specifications
Traction Therapy

Traction Therapy
Power supply AC 100–240 V, 50/60 Hz
Power consumption 75 VA

Powered Traction Unit Display 116 (W) x 87 (H) mm


Safety class according to IEC 60601-1 Class I, Type B
Dimensions 260 (W) × 350 (D) × 295 (H) mm
Weight 14 kg
Force range 1–90 kg (1–198 lbs)
Intermittent, Static, Progressive-intermittent, Progressive-static,
Traction mode
Progressive-regressive, Cyclic-intermittent, Cyclic-static, Cyclic
User-defined protocol memories 30
Timer Max. 99 min.

Ordering Data
Standard Kit *Standard kit includes main unit. Traction Packages
010850 Patient Switch Fixed Traction Table Package, including TM-400 traction unit
180350 Power Supply Cord (220−240 V, Type F) or Fixed Height Traction Table including 2 Armpit Holders,
8005700
180290 Power Supply Cord (110−120 V, Type A) 600 × 2500 mm
011977 Cervical Harness
011978 Pelvic Harness
010850 012003 Spreader Bar

Optional Accessories
011843 Traction Rope Kit
011975 Triangular Flexion Stool TM-400 + 8005700
011976 Pillow Electric Traction Table Package, including TM-400 traction unit
011977 Cervical Harness 8005702 Electric Variable Height Traction Table, 640 × 2540 mm
011978 Pelvic Harness 011977 Cervical Harness
011990 Thoracic Harness 011978 Pelvic Harness
012003 Spreader Bar 011990 Thoracic Harness
8005760 Armpit Holder, 2pcs/set
Traction therapy is one of the easiest and most effective methods for spinal decompression. Fixed Height Traction Table including 2 Armpit Holders,
012003 Spreader Bar
8005700
Traction therapy influences the pressure between the vertebrae. Because of the pressure 600 × 2500 mm
8005702 Electric Variable Height Traction Table, 640 × 2540 mm
decrease during traction, a mechanical effect on the nerves is generated and a biophysical
effect on the circulation and oxygen supply to the local structures occurs. This can result
in immediate pain relief, but also in a structural improvement in the long run. 011977 012003

TM-400 is installed with most common effective 8 traction modes. Parameter of each
mode can be modified to suit your particular needs. Innovative automatic calibration
function for traction force is installed. It contributes to maintaining accurate and suitable TM-400 + 8005702
traction force.
011975

Cervical Traction
Features 8005760

8 traction modes 10 languages available (English, German, French,


011990 011978
30 memorable program numbers Italian, Spanish, Portuguese, Danish, Dutch,
Automatic calibration for traction force Swedish & Chinese)
Large and high-visibility LCD screen Set and actual values of traction force are displayed
Lumbar Traction
Selectable pulling speed on the same screen
Exclusive traction table available (optional) Patient switch for safe treatment
Various types of traction harnesses can be suppied

44 45
ES-160
Specifications
Electroacupuncture

Electroacupuncture
Power supply DC 6 V
Number of channels 6 semi-independent

6-channel Programmable Electroacupuncture Safety class according to IEC 60601-1 Internally powered equipment, Type BF
Dimensions 239 (W) × 174 (D) × 41 (H) mm
Weight 600 g (without batteries)
Output mode Constant, Burst, Surge, Fast+Slow, Sweep, Random prog. 1, Random prog. 2, Random prog. 3
Maximum amplitude 8 mArms
Frequency 0.5 Hz, 0.7 Hz, 1–500 Hz
Pulse shape Symmetric bi-phasic rectangular pulse
Phase duration 50–400 μs
Timer Max. 60 min.

Ordering Data
Standard Kit *Standard kit includes main unit.
011380 Search/Stimulation Probe
011324 Electrode Cable (Black)
011325 Electrode Cable (Brown)
011326 Electrode Cable (Red)
011327 Electrode Cable (Green)
011328 Electrode Cable (Blue)
011329 Electrode Cable (Gray)
B060999 Exclusive Clips (Black), 6x
B061000 Exclusive Clips (Red), 6x
NOTE: Batteries are not included.

Main unit

011380

B061000
Electroacupuncture is to insert needles and apply electrical stimulation at ver y
precise acupuncture points. Needling the acupuncture points stimulates the ner vous Electrode
system to release chemicals in the muscles, spinal cord and brain. These chemicals B060999
Cable

either change the experience of pain, or they trigger the release of other chemicals
and hormones that influence the body’s own internal regulating system.
ES-160 has various safety functions for safe treatment. Semi-independent 6 electro
stimulation channels allow to treat various parts of body simultaneously. You can save
16 treatment parameters and quickly load & modify them as you like. The previous
treatment saving function is also installed.

Features
Semi-independent 6 electro stimulation channels Previous treatment parameter saving function & 16
Various stimulation modes installed (Constant, memorable program numbers
Burst, Surge, Fast+Slow, Sweep, Random-1, Acupuncture point search function with exclusive
Random-2, Randam-3) probe
Various safety functions for safe treatment

46 47
ES-130
Specifications
Electroacupuncture

Electroacupuncture
Power supply DC 9 V
Number of channels 3 semi-independent

3-channel Palm-sized Electroacupuncture Safety class according to IEC 60601-1 Internally powered equipment, Type BF
Dimensions 63 (W) × 27 (D) × 96 (H) mm
Weight 120 g (without battery)
Maximum amplitude 14 mArms
Frequency 1–500 Hz
Pulse shape Biphasic rectangular waveform
Phase duration 100 μs

Ordering Data
Standard Kit *Standard kit includes main unit.
260182 Carrying Bag
B180432 Electrode Cable with Clips (White)
B180433 Electrode Cable with Clips (Yellow)
B180434 Electrode Cable with Clips (Green)
NOTE: A battery is not included.

B180433

260182
B180432 B180434

Electroacupuncture is a method of encouraging the body to promote natural healing


and to improve functioning.
As the weight of ES-130 is less than 150 g (without batter y) and the unit size is
ver y compact, you can easily bring it anywhere you like. Semi-independent 3 electro
stimulation channels allow to treat for various parts of body simultaneously. “Semi-
independent channels” means that you can apply different current intensity for each
channel. Low/High intensity can be easily set by Selector Switch located at the back
side of main unit.

Features
Semi-independent 3 electro stimulation channels Frequency range selector switch
Easily portable Frequency table & fine frequency adjustment dial
Dual intensity setting (Low and High) for particular setting

48 49
VITER VR-7N Trolley-200
Others

Others
Professional-use Vibrator Mobile Cart

Electrode cable holders

Drawer for accessories Gel or water bottle tray

Large storage basket

Four lockable caster wheels

VITER VR-7N is designed to quickly produce an effect similar to that of massage Trolley-200 is feature-packed mobile cart, and it contributes to having effective
by hand. The level of intensity is selectable between High and Low to suit the body treatment with ITO devices.
conditions of patients. While you can massage yourself by using the device, we
recommend someone else’s support for more effective treatment. VITER VR-7N can
be used for almost all parts of body. Features
Both upper and lower tables on which equipment can be placed
Easily moved around with user-fliendly handle
Features
Quick massage effect Selectable High and Low stimulation intensity
Air-cooling mechanism enables continuous operation Multi-application device
Specifications
Convenient detachable handle for easy use and carry
Dimensions 529 (W) × 685 (D) × 1083–1203 (H) mm
Weight 27 kg
Available with EU series, ES series, US series, SU series
Specifications Gross weight: 35 kg
Packing detail
Power supply AC 110 or 220 V, 50/60 Hz Measurement: 950 (W) × 550 (D) × 720 (H) mm
Power consumption 35 / 45 VA
Dimensions 325 (W) × 270 (D) × 175 (H) mm
Weight 3.1 kg
High: 2900–3350 rpm
Turning Ratio
Low: 1450–1700 rpm

50 51
Best View Stand
Others

Triangular Tilt Stand

Best View Stand dramatically improves visibility and operability for therapists.

without stand with stand

Specifications
Available with EU-941, EU-921, ES-5400, ES-5200

52

Das könnte Ihnen auch gefallen