04 — Fan Motor Driver Unit, Grounded or Open Circuit

211
ATC
40 Alarm level:

LX12234,0000CF5 –19–02SEP03–1/1

Diagnostics

Reaction of controller: Temperature control is restricted.

Additional references:

Electrical information: Reference 210-15-001, General References - Summary.

Reference 245-ATC-100, Theory of Operation.

Reference 290-15-200, ClimaTrak —Checks.

Reference 290-20-200, Operation of the ATC (ClimaTrak ).

– – –1/1

1 Preliminary test 1.1 OK: If the diagnostic


trouble code is no longer
generated: Diagnosis
completed.

NOT OK: If the diagnostic


trouble code is active or
is regenerated after it has
been deleted and a
functional test has been
carried out: GO TO 1.2

1.2 OK: GO TO 2

Check the power supply to the fan motor driver unit: NOT OK: Recondition as
required and do an
Bridging plug K10/1. Operational Check for
Fuse F05/13. Fan Motors, see
Fuse F05/1. 245-ATC.

– – –1/1

TM4726 (01NOV03) 211-ATC-40 6020 to 6920S tractors


022204
PN=62
2 Checking the fan Ignition ON. OK: GO TO 5.
control Turn the fan speed control as far as it will go to the left (OFF).
Turn the temperature control as far as it will go to the left (Lo). NOT OK: GO TO 3.
Access address ATC005.
Slowly turn the fan speed control through its entire range till it stops at the other
extreme.
211
Make sure that the information displayed at address ATC005 complies with the
ATC
following:
41
ATC005 - Fan speed, shown in percent—Specification
Display:—Fan OFF ...................................................................................................... 000
Fan control turned as far to the right as
it will go .............................................................................................................. 038 - 100
Fault in circuit or driver unit ......................................................................................... Err
– – –1/1

3 Initial component test In the heater/evaporator housing, perform a visual inspection of the driver unit for fan OK: If there are no signs
motors (A59) and of the contacts associated with it: of damage: GO TO 4.

NOT OK: Recondition


sub-assemblies,
connectors or contacts as
required and do an
Operational Check for
Fan Motors, see
245-ATC.

LX1025931 –UN–30SEP03

A59—Driver unit for fan motors

Check for signs of damage or dirt.


Check the electrical connections for bad, loose, widened, slid-back or corroded
contacts.

– – –1/1

4 Checking the circuit Do a Circuit/Harness Test for Fan Motor Driver Unit (A59), see 245-ATC. OK: GO TO 5.

NOT OK: Recondition as


required and do an
Operational Check for
Fan Motors, see
245-ATC.

– – –1/1

TM4726 (01NOV03) 211-ATC-41 6020 to 6920S tractors


022204
PN=63