I PA S _ I n t e l l i g e n t P rox i m ity Alert System

180309_Rev. 1.00

KIGIS IPAS User Manual


Crossway Zone Tag(ZT)

1
Contents

1. What is Crossway Zone Tag? 3


2. Caution / Warning for Safety 4
3. Components / Names of Parts 5
4. Specifications 6
5. Installation 7
6. Setting 8
7. Operations 9
8. Check list before reporting failure 10
9. Warranty 11

Thanks for purchasing KIGIS IPAS product from KYUNGWOO SYSTECH, Inc.
This product is a safety-assisting device to prevent collisions of vehicles in crossway at industrial
working sites and manufacturing facilities.
Any property or life damage caused by the breach of safety regulation and user's carelessness will not
be held responsibility. Before using this product, please read this manual carefully.

·Model No : PAS-K01-50
·FCC ID : ZE8-PAS-K01-12
·Manufacturer : KYUNGWOO SYSTECH, Inc. / KOREA
* This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions : (1) this device may
not cause harmful interference, and (2) this device must accept any interference received, including interference that may
cause undesired operation.
* CAUTION : Changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
* NOTE : This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment
is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required
to correct the interference at his own expense.
2
1. What is Crossway Zone Tag?

IPAS Crossway Zone Tag is a safety-assisting device which prevents collisions of vehicles
running in crossway at industrial working sites and manufacturing facilities.
This product is suitable to avoid collisions caused by limited visibility in warehouses or
factories.
It makes voice alert, signal light, and LED spot-light(red/blue) on the floor by detecting
vehicle tags when multiple vehicles approach the crossway simultaneously.
Vehicle Tag installed in each vehicle communicates with Crossway ZT and drivers receive a
voice alert to prevent collisions from Indicator.
High accuracy of UWB based proximity detection is an advantage of KIGIS IPAS. The
product is available without a registration or a rectification at initial installation.

Another vehicle is
approaching, watch out!

Vehicle in
intersection

※ This product communicates associated with Vehicle Tag.


Please refer to VT/PT Installation Guide and User Manual for installation and usage of VT.
3
2. Caution/Warning for Safety

Caution!
※ Failure not to observe the precautions in this manual may result in damage to the product or your property.
Use AC 110V / 220V. Do not place the
AC110V / 220V It is needed to use a product near
power plug adapter flammable materials,
when the standard stoves, candles or
voltage is different. fire. Otherwise, it
may cause fire and
product deformation.

Do not intentionally If the product smells,


immerse the product smokes, or makes
in water or wash it abnormal noises, turn
in running water. off the power and
Otherwise, it may contact the customer
cause trouble. service center
immediately.

Caution!
※ Failure to follow the warnings in this manual may result in damage to the product or serious injury.
Do not touch the Do not place heavy
connector or the objects on the
wiring with wet product or on wiring,
hands. or shock. It may
This may cause cause electric shock
electric shock or fire. or fire.

If a connector or a Do not disassemble or


wiring gets wet, wipe modify this product.
it with a dry towel. This may cause
Otherwise, it may trouble, and After-
cause electric shock Sale Service will not
or fire. be available.

Installation Precautions
Use the product indoors Be careful not
only. It is prohibited to make a drop
to use outdoors or accident caused by
indoors with extremely poor installation.
high/low temperature Any accidents
or humidity. are irrelevant to
manufacturer.

* It is recommended to use AC power connector for protection against thunderstorm or high inflow of voltage and current.

※ Any accidents that result from not following the instructions in this manual are the user’s responsibility.
4
3. Components/Names of Parts

Components

Crossway Zone Tag(ZT) AC Power Cable Remote Control Remote Control Cable
※ It is needed to use a power (Distance Setting)
plug adapter when the
standard voltage is different.

Optional Optional
User Manual Fixture Bracket / Screw(4pcs) Eyebolt(4pcs)

※ The appearance of the product may be slightly different from the actual product received.

Names of Parts

Signal Light( ○ ▽ X )
Power Switch

Fuse Holder

AC Power Cable
Connector

LED Spot-Light(Red/Blue)

Proximity Alert Sensor(UWB)

Speaker Hole
5
4. Specifications

120mm 380mm

252mm
m
120mm 0m
20

220mm

Specifications Crossway Zone Tag(ZT)


Power 100-240~, 1.1A, 50/60Hz

LED Spot-Light Output 20W


Electrical
Feature Built-In Speaker Output 20W

· Normal Operation : Green ○


Signal Status / Alert Type · Approach Warning : Orange ▽ or Red X
/ LED Spot-Light / Voice Alert

Size 380×380×282mm
Mechanical
Weight 5,500g
Feature
Mounting Method Mounting on the celling

Frequency 3993.6MHz

Bandwidth 500MHz
UWB
Feature
Measurement Distance 1 ~ 30m

Detdction Cycle 0.5s

Operating Temperature -30 ~ 85°C


Opereation
Specification
Storage Temperature -40 ~ 85°C

※ Some features may change without prior notice to improve the performance of the product.

6
5. Installation

Caution! It is highly recommended to install IPAS with the power off.

It is recommended to install 4~6m from the ground.


Install with a fixture bracket or eyebolts as below. Switch on after connecting AC power cable.
(It is recommended to use AC power connector for protection against thunderstorm or high inflow of
voltage and current.)

Installation with Fixture Bracket

▶ Fixture Bracket(Optional)

▶ Install on the celling with


▶ Put a power cable appropriate methods
into the square hole depending on installation
condition (ex. welding)

Installation with Eyebolt(Wire)

▶ Eyebolt(Optional)

▶ Wire

※ In case of installation nearby an entrance, be careful not to let the product swing by wind.
7
6. Setting

Distance Setting
※ Set distance after installing and turning on the power.

Within 7m

① Connect a remote control ② Execute the setting ③ Locate the remote control
with a laptop using a USB program. nearby the crossway zone
remote control cable. tag. (within 7m)

Out of 7m range

④ ID will be automatically ⑤ Once the remote control is < Deactivated Screen >
registered in case of located out of 7m range,
successful connection. the setting screen will be
Adjust the setting and deactivated.
press SEND button.
(See the Note below)

※ Default setting : Alarm distance 20m / Volume 5


Setting Screen / Brightness 5 / Idle Time OFF

Activated when connected

Green LED light ON when connected

ID registered when connected(Crossway ZT)


Alarm distance : 1~30m
​Volume : 0(OFF)~5
Signal( ○ ▽ X ) Brightness : 1~5
Idle Time : 0(OFF)~50s
* What is Idle Time?
Time to stop voice alert and spot-light
by considering the vehicle non-existent until
the boundary of warning area when the one
has no movement during the setting time
8
7. Operations

Condition Operation

* Crossway ZT : No alarm sound

* LED signal : Green Circle


No vehicles in intersection * Down Spot-light : Off

* Crossway ZT
① : " A vehicle is approaching,
watch out."

* Vehicle ① : No alarm sound

* LED signal : Amber Triangle


A vehicle approaches * Down Spot-light : Blink

* Crossway ZT
: " Another vehicle is approching,
① watch out."

② * Vehicle ① : No alarm sound


* Vehicle ② : "Vehicle in intersection."
* LED signal : Red Cross
Two vehicles approach * Down Spot-light : Blink

* Crossway ZT
: " Another vehicle is approching,
① ③ watch out."

* Vehicle ① : No alarm sound



* Vehicle ② : "Vehicle in intersection."
* Vehicle ③ : "Vehicle in intersection."
* LED signal : Red Cross
More than two vehicles approach * Down Spot-light : Blink

※ This product is associated with Vehicle Tag.


The voice alert in ①~③ vehicles only operates with KIGIS IPAS VT/Indicator. 9
8. Check list before reporting failure

Question Reason Solution

Check the fuse in a fuse holder next


to the power switch on top of the
The product does Th glass tube fuse may be product. Change the fuse in case of
not turn on. disconnected. disconnection.
(Fuse specification :
6.3AL250V,ø5x20mm size)

The distance of The alert sounds in shorter


Reset the distance.
warning zone is not horizontal distance depending on
(Refer to 8P)
precise. the installation height of ZT and VT.

It is Idle Time function.


Time to stop voice alert and spot-
The alert stops in a light by considering the vehicle
You can change the Idle Time.
certain time after non-existent until the boundary of
(Refer to 8P)
sounding. warning area when the one has no
movement during the setting time.
(Default Idle Time : OFF)

Reset the volume.


The volume is low. The volume should be set low.
(Refer to 8P)

If you have any questions, please feel free to contact us at www.kyungwoo.com.


WARRANTY

Warranty Term 1 year from the purchase date

Product Name
Model Name
Place of Purchase
Date of Purchase
Name of Customer
Phone Number

* Service information
1. If a performance or functional failure occurs while proper using during the
warranty period, the repair service is free of charge.
2. When the repair service is required, please present the warranty card with all
information filled in.
3. The following cases will be charged for the repair regardless of warranty period.
· Failure due to careless use or improper repair or modification
· Failure due to non-compliance to the specifications stated in this manual
4. After the expiration of warranty period, a certain fee will be charged for the
repair service.
5. The warranty card cannot be reissued.

※ If failures occur when a person who is not in our service team tries to repair the
product and breaks down, or uses components from other companies, we will
not hold the responsibility for those failures.
※ Please contact the store where you purchased the product for the refund or
exchange of the product.

4F, Daeryung Post Tower 5, 68, Digital-ro 9-gil, Geumcheon-gu,


Seoul, 08512, Republic of Korea
T h in k Sm a rt ,
Work Safe

* Any inquiry about the purchased product is


Distributor(or purchasing store) contactable to distributor(or purchasing store) at below line.

KYUNGWOO SYSTECH, INC.


Manufacturer 4F, Daeryung Post Tower 5, 68, Digital-ro 9-gil, Geumcheon-gu,
Seoul, 08512, Republic of Korea
Tel. +82-2-985-8085 Fax. +82-2-985-8087 E mail. info@kigistec.com