Notes:
The data is for stock beams. For information on sizes not listed, please use BC CALC® software or consult with Boise EWP Engineering.
Consult Boise EWP Engineering for additional design stresses for nonstandard applications and stability issues.
Horizontal Holes
Allowable Holes in Glulam Beams
See Note 3
1/3 Depth
1/3 Depth
1/3 Depth
End Bearing
Notes: Interior Bearing
1) Square and rectangular holes are not permitted. 6) These limitations apply to holes drilled for plumbing
2) Round holes may be drilled or cut with a hole saw or wiring access only. The size and location of holes
anywhere within the shaded area of the beam. drilled for fasteners are governed by the provisions
of the National Design Specification® for Wood
3) The horizontal distance between adjacent holes shall
Construction.
be at least two times the diameter of the larger hole.
7) Beams deflect under load. Size holes to provide
4) Do not drill more than three access holes in any 4-foot
clearance where required.
long section of beam.
8) This hole chart is valid for BOISE GLULAM® beams
5) The maximum round hole diameter permitted is: supporting uniform load only. For beams supporting
9" & concentrated loads or for beams with larger holes,
Beam Depth 6" & 71/2" greater contact Boise EWP Engineering.
9) For vertical holes, see page 28 for provisions with ridge
Maximum Hole Diameter 1" 2"
beams or contact Boise EWP Engineering.
Common Details
G1 G2 G3
Beam Framing to Wall Beam Bearing for Header Beam to Wall with
Lateral
Beam Support
to Wall with Lateral Support
Beam Bearing for Header
Beam Framing to Wall
Strap per code if top plate is not BCI® Joist or engineered rimboard
continuous over beam blocking for lateral support
Strap per code if top plate is
not continuous over beam
P
TO
P TO
TO P
G4 G5 G6 G7
End Wall Bevel Plate Beam to Beam Beam to Concrete / BeamBeam to Column
to Column Connection
End Wall Bevel Plate Connection Masonry Wall Connection
Beam to Concrete/Masonry Wall
Beam to Beam Connection Minimum 1/2" air space
between beam and
P
concrete/masonry wall
TO
P
TO
TO Should be
TO
located in the
lower section of
the beam to
Verify hanger avoid splitting
Beveled Plate capacity with
manufacturer's Moisture barrier BOISE GLULAM®
specifications at bearing column or studs,
full width of beam
G8 G9 G10
Beam Depth Change at Sloped Seat Cut Bevel Cutting
Intermediate Support
Beam Depth Change
at Intermediate Support