ALLCELL TECHNOLOGIES LLC 2321 West 41st Street, Chicago, Illinois 60609 USA PH:+(1) 773.922.1155
SECTION 2: MATERIAL AND INGREDIENTS INFORMATION
Battery Cells
Other Components
ALLCELL TECHNOLOGIES LLC 2321 West 41st Street, Chicago, Illinois 60609 USA PH:+(1) 773.922.1155
SECTION 5: FIRE-FIGHTING MEASURE
- Suitable extinguishing media: Utilize a Halon, Halon replacement or water fire extinguisher to
prevent the spread of the fire to adjacent battery cells and materials. Pour water, or other non-
alcoholic liquid, from any available source over the cells immediately after knockdown or
extinguishment of the fire.
- Specific hazards: Corrosive gas may be emitted during fire.
- Specific methods of fire-fighting: When the battery burns with other combustibles
simultaneously, use the fire extinguishing method which correspond to the combustibles.
- Special protective equipment for firefighters:
o Respiratory protection: Respiratory equipment of a gas cylinder style or protection-
against-dust mask
o Hand protection: Protective gloves
o Eye protection: Goggle or protective glasses designed to protect against liquid splashes
o Skin and body protection: Protective cloth
Storage Store in a cool, well-ventilated, dry area. Do not expose to temperature above 60°C.
Handling Do not disassemble, crush or short circuit. Do not open the battery.
Battery Energy Rate The cell capacity at shipment is 30 – 60 % of the full capacity.
Disposal Dispose in accordance with applicable federal, state and local regulations.
ALLCELL TECHNOLOGIES LLC 2321 West 41st Street, Chicago, Illinois 60609 USA PH:+(1) 773.922.1155
- Skin Protection: Not necessary under normal use. Wear rubber apron and rubber gloves if
handling a ruptured or leaking battery cell.
Appearance
- Physical state: Solid
- Form: Irregular/Rectangle
- Color: Black outer case
- Odor: No odor
- pH: NA
- Specific temperatures/temperature ranges at which changes in physical state occur. There is no
useful information for the product as a mixture.
- Flash point: NA
- Explosion properties: NA
- Density: NA
- Solubility: Insoluble in water
This product does not produce toxicological properties during routine handling and use.
Sensitization: NO Teratogenicity: NO Reproductive toxicity: NO Acute toxicity: NO
- Irritation: Risk of irritation only occurs if battery cells are mechanically, thermally or electrically
abused and the enclosure is comprised.
- Neurological Effects: Not applicable.
- Sensitization: Not applicable.
- Teratogenicity: Not applicable.
- Reproductive Toxicity: Not applicable.
- Mutagenicity (Genetic Effects): Not applicable.
- Toxicologically Synergistic Materials: Not available.
ALLCELL TECHNOLOGIES LLC 2321 West 41st Street, Chicago, Illinois 60609 USA PH:+(1) 773.922.1155
SECTION 13: DISPOSAL CONSIDERATIONS
Recommended methods for safe and environmentally preferred disposal:
- Product (waste from residues): Do not throw out a used battery cell. Recycle it through the
recycling company.
- Follow all federal, state, and local regulations.
- Contaminated packaging: Neither a container nor packing is contaminated during normal use.
When internal materials leaked from a battery cell contaminates, dispose as industrial wastes
subject to special control.
In the case of transportation, avoid exposure to high temperature and prevent the formation of any
condensation. The container must be handled carefully.
The product has been evaluated and passed the UN Manual of Tests and Criteria.
Lithium Ion batteries are considered to be “Rechargeable batteries” and meet the requirements of
transportation by the U.S. Department of Transportation (DOT), International Civil Aviation
Administration (ICAO), International Air Transport Association (IATA) Dangerous Goods Regulations
(54th Edition) and International Maritime Dangerous Goods (IMDG) Code.
Page 5 of 5