Sie sind auf Seite 1von 10

PROJECT:

BILL OF QUANTITIES - DUCTLESS VENTILATION SYSTEM


SL NO. DESCRIPTION UNIT QTY UNIT SUPPLY SUPPLY AMOUNT
RATE (RS) (RS)
A

A B1
1 S/I/T/C of CEILING MOUNTED JET VENT FAN(Axial Type)

Supply, installing, testing and commissioning of Ductless Ventilation / Axial type Jet fans as per
attached specifications for normal ventilation & smoke exhaust . Each fan shall be complete with
dual speed motor and die cast aluminium impeller. Casing shall be made of Hot dipped
Galvanized steel. The Motor shall be run on the electrical power suitable for 415V/3Ph/ 50Hz.

Supply, installing, testing and commissioning of Ductless Ventilation / Jet fans as per
Specifications for Normal Ventilation and Smoke Exhaust. . The complete fan assembly with its Nos. 0
casing, impeller and motor ( not only motor or one of the item ) shall be sourced from one
manufacturer and certified and tested as per EN12101-3-:2015 300 degree for 2 Hrs
operation.Silencer lenght should be Minimum of 2D.Each Jet Fan assembly shall connect to a
composite PLC Panel controlled by CO Sensors / Fire Alarm System for Smoke Extraction.Model
1.1 AJR 315-2/4 (B) (0.8/0.16kW),Dia of fan 315mm

2 S/I/T/C of TUBE AXIAL FAN WITH IE2 MOTOR(Basement Exhaust)


Supply, installation, testing and commissioning of Direct drive Tube Axial fans complete with Pre
Galvanised/MS Powder coated Casing with spun flanges, adjustable pitch die cast aluminium
impeller (Hub and Aerofoil blades) and IE2 motors.Long Casing position shall be as per the job
requirement and shall be marked on the fan assembly.The complete fan assembly with its casing,
impeller and motor ( not only motor or one of the item ) shall be sourced from one manufacturer
and certified and tested as per EN12101-3- 2015 300 degree for 2 Hrs operation.Axial fan should
be licensed to bear AMCA seal for air performance and sound performance or must be
demonstrated in AMCA accredited laboratory as per AMCA publication. The complete assembly
must have certificate of consistency of performance by BSI and must bear CE marking.

ZONE (1 &2 )- (Normal Mode + Emergency Mode Exhaust )-Capacity- 15600 cfm @ 20mm Wg
2.1 Nos. 0
Static Pressure Fan should be : 800 dia / 4.0 kw
ZONE (1 &2)- (Emergency Mode Exhaust )-Capacity- 15600 cfm @ 20mm Wg Static Pressure Fan
2.2 should be : 800 dia / 4.0 kw (In case of Emergency/fire mode All 4 Ex Air Fans need to be Nos. 0
switched on in order to get 12 acph)

3 S/I/T/C of TUBE AXIAL FAN WITH IE2 MOTOR(FOR FRESH AIR)

Supply, installation, testing and commissioning of Direct drive Tube Axial fans complete with Pre
Galvanised Steel/MS Powder Coated Casing with spun flanges, adjustable pitch die cast
aluminium impeller (Hub and Aerofoil blades) and IE3 motors. Casing position shall be as per the
job requirement and shall be marked on the fan assembly.The complete fan assembly with its
casing, impeller and motor ( not only motor or one of the item ) shall be sourced from one
manufacturer.Axial fan should be licensed to bear AMCA seal for air performance and sound
performance or must be demonstrated in AMCA accredited laboratory as per AMCA publication.
The complete assembly must have certificate of consistency of performance by BSI and must
bear CE marking.

ZONE (2 )- (Freshair )-Capacity- 12500 cfm @ 20mm Wg Static Pressure Fan should be : 710
3.1 Nos. 0
dia / 3.0 kw
Nos.
4 S/I/T/C OF CO SENSORS

4.1 Supply, installation, testing and commissioning of CO Sensors (0 - 250 PPM detection Range) Nos. 0
Make: Honeywell

5 CFD Analysis

5.1 The specific aim of the CFD is to find the optimal locations, number & configuration of the Jet Nos. 0
fans required for the ventilation of the car parking lot, for the given positions of inlets and
exhaust, and given configuration of the exhaust & fresh air fans, such that it meets requirements
of CO exposure limit set by health and safety regulations(FOR BASEMENT)

6 CONTROL PANELS

Supply of Electrical cum PLC Panel for Lower Basement with MCB feeders with starters for for s
dual speed 3 phase Jet Fan fans of 0.8/0.16 kW each,MCCB feeders with starters for Exhaust fans
6.1 single speed & Fresh Air Fan of . controlled by CO Sensors, with suitable incomer MCCB, Set
metering panel, aluminium bus bar , PLC logic controller with necessary internal control wiring
etc

6.2 Basement for ZONES - 1 & 2 - SINGLE PANELS


Design,manufacture, supply of indoor type
floor mounting PLC panel consisting of following.
a. Incomer
1 nos 250 A TP MCCB with AL busbar.- 1 Nos
b. Outgoing Feeders
i. 10 A TP MCB,3 nos 9 A contactor,1 no OLR suitable
ON and OFF INDICATION LAMP.For 0.8 KW(high speed)
and 0.16 KW(low speed)Jet fan:-10 nos
ii.4.0 KW VFD for Normal Mode Exhaust Air fans - RO
ii.4.0 KW VFD for Fire Mode Exhaust Air fans - RO
ii.3.0 KW VFD for FreshAir fans - RO
iii. PLC feeder consists of SCHNEIDER make PLC suitable for 5 Nos CO sensors required
no of control relays,rectifier, SMPS lockable type automanual selector switch back up
MCB,terminals wiring etc.
Above mentioned panel Nos

7 Installation of Jet fans Nos

8 Installation of Axial fans


4.0 Kw & 3 KW Nos
9 Installation of CO Sensors Nos

Supply andlaying of power and control cables

6C X 2.5 sqmm Cu armoured cables(for jet fans) Nos


2 runs of 3C X 16 sqmm Al armoured cables(for axial fans) Nos
4C X 2.5 sqmm Cu aromured cables(for CO sensors) Nos

End terminations for above mentioned cables(double compression)

6C X 2.5 sqmm Cu armoured cables(for jet fans) Nos


3C X 16 sqmm Al armoured cables(for axial fans) Nos
4C X 2.5 sqmm Cu aromured cables(for CO sensors) Nos

Supply and installation of GI ladder type cable trays

150mm(W) x 50mm(H) x 1.6mm(T) Nos


200mm(W) x 50mm(H) x 1.6mm(T) Nos
300mm(W) x 50mm(H) x 1.6mm(T) Nos

Earthing
8 SWG GI wire Nos
25 x 3mm GI flat Nos

Total Basic Amount (INR) Inclusive of Freight Till Site SUPPLY INR 0
GST @ 18 % WHEREVER APPLICABLE (INR) INR 0
TOTAL VALUE (INR) INR 0
` DATE:

UNIT INSTALLATION TOTAL (RS)


INSTALLATION AMOUNT (RS) A+B
RATE (RS) B

0 0
0 0

0 0

0 0
0 0

0 0
INSTALLATION INR 0 INR 0

Das könnte Ihnen auch gefallen