Deck Design Data Sheet

COMPOSITE DECK
C omposite deck and Dofireshear studs affect
ratings?
Most UL floor assembly fire ratings
Arerequired?
shear studs

Shear studs are used to make steel


accept studs as an option. beams composite. They are not
composite beams are necessary to make the deck composite

natural partners in steel


W hat is the size of
the shear stud?
A 3/4” diameter stud is the maximum
but they enhance the load capacity of
the composite slab - as an example 3”
20 gage Lok Floor (40 ksi yield) with
allowed by the AISC specifications - a 5.5” 3 ksi normal weight concrete
smaller sizes are rarely, if ever used. slab has the following factored LRFD
The stud must be at least 1 1/2” nominal moments:
construction. Some of the longer than the depth of the deck rib. Stud Spacing ?Mn, in.k.
on Beams

frequently asked questions I s the location of the stud within


the deck rib important?
Yes - for the beams, but no for
1’
2’
3’
74.7
71.2
65.3
the deck. For best construction of No studs 53.5
about the combination of composite beams place studs in the At times shear studs are not used to
portion of the deck closest to the make beams composite but are
beam ends. The stud shear strength present to transfer diaphragm shear
is affected by deck profile and stud
shear studs and composite location in the corrugation.
loads into the frame. In this case the
AISC spacing rules (for composite
construction) do not apply.
deck are the subject of
Does Canam
sell studs?
No - we sell the deck that studs go
this data sheet.
D o shear studs act through as they are welded to the
structural steel.
to fasten the deck?

Canthrough
Yes - shear studs can replace the
welds used to attach the deck to the
studs be welded
beams; however, if the studs are galvanizing?
spaced greater than 12” o.c., welds Yes - G90 is the maximum
(5/8” min.) should be used where the recommended. Welding is also
studs are missing. Studs are installed possible through cellular deck.
after floors are decked. Safety Gage combinations greater than
requires the SDI minimum of 5/8” welds 18/18 require special care.
to stabilize deck during the interim.