Sie sind auf Seite 1von 4

PC3SF11YVZA/PC3SF11YVZB

Reinforced Insulation Type


PC3SF11YVZA/ Phototriac Coupler for
PC3SF11YVZB Triggering
■ Features ■ Outline Dimensions (Unit : mm)
1. Isolation voltage between input and output (Viso (rms):5kV)
Internal connection
2. High critical rate of rise of OFF-state voltage 2.54±0.25
diagram
(dV/dt:MIN. 1 000V/µs) 6 5 4

3. Internal isolation distance (0.4mm or more)


Anode 3SF11
4. Recognized by UL (File No. E64380) mark

6.5±0.3
Approved by VDE (VDE0884, File No.127413) NC
1 2 3
Approved by BSI (BS415, File No.6690,
BS7002, File No.7421) 1 2 3
Approved by SEMKO (File No.0033029/01-04) 0.6±0.2
1.2±0.3
Approved by DEMKO (File No.310107-01)
Approved by FIMKO (File No.15795) 7.12±0.3 7.62±0.3
❈ PC3SF11YVZA, PC3SF11YVZB are for 200V line

3.5±0.3
■ Applications

2.5MIN.
1. Home appliances
2. OA equipment, FA equipment
0.5±0.1 10.16±0.5
3. SSRs

■ Model Line-up 1 Anode 4 Anode, Cathode


Minimum trigger current (IFT[MAX.]) for AC 200V line 2 Cathode 5 No external connection
3 NC 6 Anode, Cathode
10mA PC3SF11YVZA
7mA ❈ Pin 5 is not allowed external connection
PC3SF11YVZB

■ Absolute Maximum Ratings (Ta=25°C)


Parameter Symbol Rating Unit
*1
Forward current IF 50 mA
Input
Reverse voltage VR 6 V
*1
RMS ON-state current IT (rms) 0.1 A
Output Peak one cycle surge current Isurge 1.2 (50Hz sine wave) A
Repetitive peak OFF-state voltage VDRM 600 V
*2
Isolation voltage Viso (rms) 5 kV
Operating temperature Topr −30 to +100 °C
Storage temperature Tstg −55 to +125 °C
Soldering temperature Tsol 260 (For 10s) °C
*1 The derating factors of absolute maximum ratings due to ambient temperature are
shown in Fig.1, 2
*2 AC for 1 min, 40 to 60%RH, f=60Hz

Notice In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet Internet address for Electronic Components Group http://sharp-world.com/ecg/
PC3SF11YVZA/PC3SF11YVZB

■ Electro-optical Characteristics (Ta=25˚C)


Parameter Symbol Conditions MIN. TYP. MAX. Unit
Forward voltage VF IF=20mA − 1.2 1.4 V
Input
Reverse current IR VR=3V − − 10−5 A
Repetitive peak OFF-state current IDRM VD=VDRM − − 10−6 A
ON-state voltage VT IT=0.1A − − 2.5 V
Output
Holding current IH VD=6V 0.1 − 3.5 mA

Critical rate of rise of OFF-state voltage dV/dt VD=1/√2 • VDRM 1 000 2 000 − V/µs
PC3SF11YVZA − − 10
Transfer Minimum trigger current IFT VD=6V, RL=100Ω mA
PC3SF11YVZB − − 7
charac-
teristics Isolation resistance RISO DC=500V, 40 to 60%RH 5×1010 1011 − Ω
Turn-on time ton VD=6V, RL=100Ω, IF=20mA − − 100 µs

Fig.1 RMS ON-state Current vs. Ambient Fig.2 Forward Current vs. Ambient
Temperature Temperature
175 70

150 60
RMS ON-state current Ir (rms) (mA)

Forward current IF (mA)

125 50

100 40

75 30

50 20

25 10

0 0
−30 −20 −10 0 10 20 30 40 50 60 70 80 90 100 −30 −20 −10 0 10 20 30 40 50 60 70 80 90 100
Ambient temperature Ta (˚C) Ambient temperature Ta (˚C)

Fig.3 Forward Current vs. Forward Voltage Fig.4 Minimum Trigger Current vs. Ambient
Temperature
10
VD=6V
100 9 RL=100Ω
Ta=75˚C
Minimum trigger current IFT (mA)

8
50
Forward current IF (mA)

50˚C 7

20 6
25˚C 0˚C
5
10
4
5 3
−25˚C
2
2
1
1 0
0.9 1 1.1 1.2 1.3 1.4 1.5 −40 −20 0 20 40 60 80 100
Forward voltage VF (V) Ambient temperature Ta (˚C)
PC3SF11YVZA/PC3SF11YVZB

Fig.5 ON-state Voltage vs. Ambient Fig.6 Holding Current vs. Ambient
Temperature Temperature
10
IT=100mA VD=6V
2.4

2.2

Holding current IH (mA)


ON-state voltage VT (V)

1.8
1

1.6

1.4

1.2

1 0.1
−40 −20 0 20 40 60 80 100 120 −40 −20 0 20 40 60 80 100
Ambient temperature Ta (˚C) Ambient temperature Ta (˚C)

Fig.7 Repetitive Peak OFF-state Current vs. Fig.8 Relative Repetitive Peak OFF-state
Ambient Temperature Voltage vs. Ambient Temperature
1 1.3
Repetitive peak OFF-state current IDRM (µA)

VD=600V
Relative repetitive peak OFF-state voltage

1.2
VDRM (Tj=Ta) / VDRM (Tj=25˚C)

0.1
1.1

0.01 1

0.9
0.001
0.8

0.0001 0.7
−40 −20 0 20 40 60 80 100 −40 −20 0 20 40 60 80 100
Ambient temperature Ta (˚C) Ambient temperature Ta (˚C)

Fig.9 Turn-on Time vs. Forward Current

1 000
VD=6V
RL=100Ω
Ta=25˚C
Turn-on time tON (µS)

100

10
1 10 100
Forward current IF (mA)
NOTICE
● The circuit application examples in this publication are provided to explain representative applications of SHARP
devices and are not intended to guarantee any circuit design or license any intellectual property rights. SHARP takes
no responsibility for any problems related to any intellectual property right of a third party resulting from the use of
SHARP's devices.
● Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. SHARP
reserves the right to make changes in the specifications, characteristics, data, materials, structure, and other contents
described herein at any time without notice in order to improve design or reliability. Manufacturing locations are
also subject to change without notice.
● Observe the following points when using any devices in this publication. SHARP takes no responsibility for damage
caused by improper use of the devices which does not meet the conditions and absolute maximum ratings to be used
specified in the relevant specification sheet nor meet the following conditions:

(i) The devices in this publication are designed for use in general electronic equipment designs such as:
- - - Personal computers
- -- Office automation equipment
- -- Telecommunication equipment [terminal]
- - - Test and measurement equipment
- - - Industrial control
- -- Audio visual equipment
- -- Consumer electronics

(ii) Measures such as fail-safe function and redundant design should be taken to ensure reliability and safety when
SHARP devices are used for or in connection with equipment that requires higher reliability such as:
- -- Transportation control and safety equipment (i.e., aircraft, trains, automobiles, etc.)
- - - Traffic signals
- - - Gas leakage sensor breakers
- - - Alarm equipment
- -- Various safety devices, etc.

(iii)SHARP devices shall not be used for or in connection with equipment that requires an extremely high level of
reliability and safety such as:
- - - Space applications
- -- Telecommunication equipment [trunk lines]
- -- Nuclear power control equipment
- -- Medical and other life support equipment (e.g., scuba).
● Contact a SHARP representative in advance when intending to use SHARP devices for any "specific" applications
other than those recommended by SHARP or when it is unclear which category mentioned above controls the
intended use.
● If the SHARP devices listed in this publication fall within the scope of strategic products described in the Foreign
Exchange and Foreign Trade Control Law of Japan, it is necessary to obtain approval to export such SHARP devices.
● This publication is the proprietary product of SHARP and is copyrighted, with all rights reserved. Under the copyright
laws, no part of this publication may be reproduced or transmitted in any form or by any means, electronic or
mechanical, for any purpose, in whole or in part, without the express written permission of SHARP. Express written
permission is also required before any use of this publication may be made by a third party.
● Contact and consult with a SHARP representative if there are any questions about the contents of this publication.

Das könnte Ihnen auch gefallen