Beruflich Dokumente
Kultur Dokumente
2. Mainframe System
NONE
3. Open System
NONE
HDS Confidential 1 of 3
The change of contents for Version 70-03-34-00/00-MO97
1 Failure of error check by write sequence number
Phenomena For SATA-E DP volumes, an error check by write sequence number
might not be performed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) SATA-E drives are used for a DP/DT pool.
(2) The last 2 bits of data slot number is 00. (The error check is not
performed once every 4 times.)
Affected Products/Version DKCMAIN: 70-02-03-00/00 and higher
Fixed Product/Version DKCMAIN: 70-03-34-00/00
Category Open or Mainframe
Changed Part DKCMAIN
HDS Confidential 2 of 3
4 Logic path blockage at PS ON or DKC addition
Phenomena At PS ON or DKC addition, a logic path of an ESW PCB was blocked
and SIM=7603 and SSB=3306 were output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when one of the following conditions is met.
(1) PS ON is performed for a DKC with a configuration of 4 MPBs and 2
ESW PCBs.
(2) A DKC is added with a configuration of 4 MPBs and 2 ESW PCBs.
Affected Products/Version DKCMAIN: 70-03-32-00/00 and higher
Fixed Product/Version DKCMAIN: 70-03-34-00/00
Category Open or Mainframe
Changed Part DKCMAIN
HDS Confidential 3 of 3