2-wire type
The sensor housing is thick and tough. The sensor is securely
tightened to prevent loosening caused by vibration or shock.
Proximity Sensors
EV Series
Flexible joint
The cable is connected to the sensor head with a highly flexible joint
that can be bent to a 90-degree angle while still preventing cable
wire breakage.
ASK KEYENCE
1-888-KEYENCE
www.keyence.com/ASKG
FREE DOWNLOAD
www.keyence.com/DLG
Free downloads for product and technical support are readily available in
one convenient location
218
2-wire type Proximity Sensors EV EV
EZ
ED
Specifications
PROXIMITY SENSORS
EM
DC 2-wire type ES
ET
Type Shielded Non-shielded
TA
N.O. type EV-108M EV-112M EV-118M EV-130M1. EV-108U1. EV-112U EV-118U EV-130U
Model EG
N.C. type EV-108MC EV-112MC EV-118MC EV-130MC1. EV-108UC1. EV-112UC EV-118UC EV-130UC
Size M8 M12 M18 M30 M8 M12 M18 M30 DD
Appearance
Detecting distance 1.5 mm 0.06" ±10% 2.5 mm 0.10" ±10% 5 mm 0.20" ±10% 10 mm 0.39" ±10% 4 mm 0.16" ±10% 8 mm 0.31" ±10% 15 mm 0.59" ±10% 27 mm 1.06" ±10%
Detectable object Ferrous metals (see Characteristics for nonferrous metals)
Standard target
10 x 10 mm 0.39" 12 x 12 mm 0.47" 18 x 18 mm 0.71" 30 x 30 mm 1.18" 20 x 20 mm 0.79" 30 x 30 mm 0.47" 50 x 50 mm 1.97" 70 x 70 mm 2.76"
(iron, t=1 mm 0.04")
Hysteresis 10% max. of detecting distance 20% max. of detecting distance, within -10 to +70°C (14 to 158°F)
Response frequency 800 Hz 600 Hz 350 Hz 250 Hz 800 Hz 600 Hz 350 Hz 250 Hz
-5 to +20%,
±10% max. of detecting distance at 23°C (73.4°F), ±10% max. of detecting distance,
Temperature fluctuation within -10 to +70°C
within -25 to +70°C (-13 to +158°F) within -10 to +70°C (14 to 158°F)
(14 to 158°F)
Operation mode N.O./N.C. (Differs by model)
Control output
5 to 80 mA 5 to 200 mA 5 to 80 mA 5 to 200 mA
(switching capacity)
Reversed polarity, Reversed polarity,
Protection circuit Reversed polarity, short-circuit, surge voltage Reversed polarity, short-circuit, surge voltage
surge voltage surge voltage
Power supply 12 to 24 VDC, Ripple (p-p) 20% max. New Products
Ratings Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m 6.6' cable)
Enclosure rating IP67
Fiberoptic
Ambient temperature -25 to +80°C (-13 to +176°F), No freezing
Sensors
Relative humidity 35 to 95%, No condensation
Vibration resistance 10 to 55 Hz, 1.5 mm 0.06" double amplitude in X, Y, and Z directions, 2 hours
500 m/s 1640.4' in X, Y, and Z
2
1,000 m/s 3280.8' in X, Y, and Z
2
500 m/s 2 1640.4' in X, Y, and Z 1,000 m/s 2 3280.8' in X, Y, and Z
Photoelectric
Shock resistance Sensors
directions, 3 times respectively directions, 3 times respectively directions, 3 times respectively directions, 3 times respectively
Housing Stainless steel Nickel-plated brass Stainless steel Nickel-plated brass
Cable length 2 m 6.6' Proximity
Weight
Approx. 42 g Approx. 110 g Approx. 150 g Approx. 300 g Approx. 42 g Approx. 110 g Approx. 140 g Approx. 260 g Sensors
(including cable and nuts)
1. This product does not comply with CE marking. Safety
Equipment
Connector type (DC 2-wire type)
Flow/
Type Shielded Non-shielded Pressure/
Model EV-108MSO (2091) EV-112MSO (2062) EV-118MSO (2063) EV-130MSO (2064) 1. EV-112USO (2065) EV-118USO (2066) 1. Temperature
Size M8 M12 M18 M30 M12 M18
Detecting distance 1.5 mm 0.06" ±10% 2.5 mm 0.10" ±10% 5 mm 0.20" ±10% 10 mm 0.39" ±10% 8 mm 0.31" ±10% 15 mm 0.59" ±10% Measurement
Detectable object Ferrous metals (see Characteristics for nonferrous metals) Sensors
Standard target
10 x 10 mm 0.39" 12 x 12 mm 0.47" 18 x 18 mm 0.71" 30 x 30 mm 1.18" 50 x 50 mm 1.97"
(iron, t=1 mm 0.04")
Hysteresis 10% max. of detecting distance
20% max. of detecting distance, Controls
within -10 to +70°C (14 to 158°F)
Response frequency 800 Hz 600 Hz 350 Hz 250 Hz 600 Hz 350 Hz
±10% max. of detecting distance at 23°C (73.4°F),
±10% max. of detecting distance, Static
Temperature fluctuation within -10 to +70°C Eliminators
within -25 to +70°C (-13 to +158°F)
(14 to 158°F)
Operation mode N.O.
Control output Vision
5 to 80 mA 5 to 200 mA
(switching capacity) Systems
Reversed polarity, surge
Protection circuit Reversed polarity, short-circuit, surge voltage
voltage
Power supply 12 to 24 VDC
Marking
Current consumption
Equipment
(leakage current): 1.0 mA
Ratings Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. max.,
Residual voltage: 3.6 V Code Readers
max. (with 2-m 6.6' cable)
Enclosure rating IP67
Ambient temperature -25 to +80°C (-13 to +176°F), No freezing Handheld Mobile
Relative humidity 35 to 95%, No condensation Computers
Housing Stainless steel Nickel-plated brass
Cable length 500 mm 19.69"
Weight (including cable and Microscopes
Approx. 30 g Approx. 55 g Approx. 95 g Approx. 245 g Approx. 55 g Approx. 140 g
connector)
1. This product does not comply with CE marking. Projector/
3D Measurement
Systems
ED
PROXIMITY SENSORS AC 2-wire type
EM
Type Shielded
ES
Model EV-12M1. EV-18M1. EV-30M1.
ET
Size M12 M18 M30
TA
EG
DD
Appearance
Safety Weight
Approx. 110 g Approx. 150 g Approx. 300 g
(including cable and nuts)
Equipment
1. This product does not comply with CE marking.
Flow/
Pressure/
Temperature
Term Configuration Definition
Measurement
Sensors
• T he sensing coil is encased in a metal-shielding.
Shielded type • T his type is less affected by surrounding metal, and
Controls can be embedded in a metal base.
Metal
Marking
Equipment
Code Readers
Handheld Mobile
Computers
Microscopes
Projector/
3D Measurement
Systems
PROXIMITY SENSORS
EM
EV Series EV Series ES
DC 2-wire type AC 2-wire type ET
TA
Brown*
1 Load EG
Brown*
Load
DD
protection circuit
Main circuit
Main circuit
protection circuit
12 to 24 to
Overcurrent
24 VDC 240 VAC
Overcurrent
Current
detection
circuit Blue
4 Blue
* L oad can also be connected between blue wire and negative terminal of power supply. * Load can also be connected between blue wire and power supply.
The M8 sensor does not contain short-circuit protection or a current detection circuit.
1 and 4 in the circuit diagram shows the pin number of the connector type.
Connections
EV Series: DC 2-wire type/Connector type EV Series: AC 2-wire type
1 Load Load
4
Fiberoptic
Connection to built-in DC power supply type PLC Sensors
(externally connected power supply)
Series connection
Photoelectric
+ 24 V Up to 3 proximity sensors can be Load Sensors
connected in Series. For this, the 500 kΩ -
IN supply voltage must be within the 10 MΩ Proximity
Brown 1
range of 85 to 240 VAC. If sensor 500 kΩ - Sensors
COM 0V 10 MΩ
Blue 4 operation is unstable, connect resistors
Safety
PLC with a resistance of 500 kΩ to 10 MΩ
Equipment
Connection to built-in DC power supply type PLC parallel to the sensor in order to balance the supply
(internally connected power supply) voltage. Flow/
Pressure/
Temperature
+ 24 V
COM Measurement
Parallel connection
Sensors
Brown IN Connect proximity sensors in parallel
1 Load
Blue
only if the sensors do not operate
4 0V Controls
simultaneously. Note, however, that
PLC the leakage current will increase in
Connection to PLC having no internal DC power supply proportion to the number of sensors Static
Eliminators
connected.
Vision
Brown 1 IN Systems
COM
Blue 4
Marking
Equipment
PLC
For connections indicated by the dotted lines, Code Readers
reverse brown and blue sensor wires.
Handheld Mobile
Computers
Pin arrangement of connector type
2 1 Microscopes
Projector/
3 4 3D Measurement
Systems
1 and 4 in the circuit diagram shows the pin number of the
connector type.
ED
EM
PROXIMITY SENSORS Characteristics
ES Detecting range (Typical)
ET
DC 2-wire type AC 2-wire type
TA EV-108M/112M/118M/130M EV-108U/112U/118U/130U EV-12M/18M/30M
EG Y Y Y
Detecting distance Y (mm inch)
20 0.79"
EV-118M EV-118U EV-18M
5 0.20" 5 0.20"
EV-112M 10 0.39" EV-12M
EV-112U
EV-108M
EV-108U
0 0 0
-8 -4 0 4 8 - 20 - 10 0 10 20 -8 -4 0 4 8
-0.31" -0.16" 0.16" 0.31" -0.79" -0.39" 0.39" 0.79" -0.31" -0.16" 0.16" 0.31"
Distance X (mm inch) Distance X (mm inch) Distance X (mm inch)
8 0.8 1
Leakage current (mA)
6 0.7
4 0.6 0.5
2 0.5
New Products
0 0.4 0
5 10 30 50 100 0 10 20 30 40 100 200
Load current (mA) Supply voltage (V) Supply voltage (V)
Fiberoptic
Sensors
Photoelectric
Detecting distance vs. size and material of target (Typical)
Sensors DC 2-wire type
EV-108M EV-112M EV-118M EV-130M
Y 0.04" Y 0.04" Y 0.04" Y 0.04"
t=1 t=1 t=1 t=1
Proximity Iron Iron Iron Iron
Detecting distance Y (mm inch)
Detecting distance Y (mm inch)
Temperature 0 0 0 0
4 8 12 16 20 24 2.5 5 7.5 10 12.5 15 4 8 12 16 20 24 6 12 18 24 30 36
0.16" 0.31" 0.47" 0.63" 0.79" 0.94" 0.10" 0.20" 0.30" 0.39" 0.50" 0.60" 0.16" 0.31" 0.47" 0.63" 0.79" 0.94" 0.24" 0.47" 0.71" 0.94" 1.81" 1.42"
Measurement One side of target X (mm inch) One side of target X (mm inch) One side of target X (mm inch) One side of target X (mm inch)
Sensors
EV-108U EV-112U EV-118U EV-130U
Y 0.04" Y 0.04" Y 0.04" Y 0.04"
t=1 t=1 t=1 t=1
Detecting distance Y (mm inch)
Controls
Detecting distance Y (mm inch)
AC 2-wire type
Code Readers EV-12M EV-18M EV-30M
Y 0.04" Y 0.04" Y 0.04"
t=1 t=1 t=1
Iron Iron Iron
Detecting distance Y (mm inch)
Detecting distance Y (mm inch)
PROXIMITY SENSORS
EM
Mounting When the load current is low ES
ET
When mounting the sensor, insert the attached toothed When the load current is less than 5 mA, connect a bleeder
TA
washer. Do not tighten beyond the torque specified in the resistor to give the sensor 5 mA or more load current. Make
EG
following table. sure the residual voltage is less than the reset voltage of the
DD
load.
Shielded type Non-shielded type
I (mA)
B A B A Load
Power supply voltage
Dimension A Tightening torque
Model Bleeder resistor R Vs
(mm inch) at A at B
EV-108M, EV-108U 3 0.12" 8 N·m max. 9 N·m max.
EV-12M, EV-112M,
6 0.24" 15 N·m max. 30 N·m max. Calculate the resistance (R) and rated bleeder resistor
EV-112U
EV-18M, EV-118M, wattage (P) from the following expressions:
7 0.28" 60 N·m max. 70 N·m max.
EV-118U
EV-30M, EV-130M,
EV-130U
10 0.39" 120 N·m max. 180 N·m max. AC 2-wire type:
VS VS2
P≤ (kΩ) P> (mW)
Surrounding metal 5-I R
Projector/
3D Measurement
Systems
ED
EM
PROXIMITY SENSORS Dimensions Unit: mm inch
ES DC 2-wire type
ET
EV-108M EV-112M
TA
Toothed washer
EG
Toothed washer Across-flats: 17 t= 4 0.67" t= 0.16"
DD Across-flats: 12 t= 3 0.47" t= 0.12"
M12, P=1
M8, P=1 Operation indicator
Operation indicator
ø0.23" ø5.9, 2-core x 0.5 mm2
2
ø0.14" ø3.5, 2-core x 0.15 mm Cable length: 2 m 6.6'
Cable length: 2 m 6.6'
27 9.5 36 6
1.06" 0.35" 1.42" 0.24"
46.5 52
1.83" 2.05"
EV-118M EV-130M
Fiberoptic
Sensors
36 6
1.42" 0.24" 39 7
Photoelectric 1.54" 0.26"
Sensors 52
2.05" 56
2.20"
Proximity
Sensors
EV-108U EV-112U
Safety
Toothed washer
Equipment Toothed washer
Across-flats: 12 t= 3 0.47" t= 0.31" Across-flats: 17 t= 4 0.67" t= 0.16"
Flow/ M12, P=1
M8, P=1
Pressure/ Operation indicator Operation indicator
Temperature ø0.41"
ø0.06" ø0.14" ø3.5, 2-core x 0.15 mm2 ø0.23"ø5.9, 2-core x 0.5 mm2
ø6.8 ø10.4 Cable length: 2 m 6.6'
Cable length: 2 m 6.6'
Measurement
Sensors
5.5 8
0.22" 0.31"
Controls
26.5 9.5 36 6
1.04" 0.37" 1.42" 0.24"
Static 52
46
Eliminators 1.81" 2.05"
Vision
Systems EV-118U EV-130U
Microscopes 12 12
0.47" 0.47"
38 6 39 7
1.50" 0.24" 1.54" 0.28"
Projector/
3D Measurement
Systems 54 56
2.13" 2.20"
PROXIMITY SENSORS
EV-108MSO (2091) EV-112MSO (2062) EM
ES
Toothed washer Toothed washer
Across-flats: 12 t= 3 0.47" t= 0.31" Across-flats: 17 t= 4 0.67" t= 0.16" ET
M8, P=1 M12, P=1 TA
Operation indicator Operation indicator EG
ø3.3 ø0.13" x 0.15 mm2 ø5.6 ø0.22" x 0.3 mm2 DD
ø14 ø14
ø0.55" ø0.55"
27 9.5 36 6
1.06" 0.35" 1.42" 0.24"
8 36 6
0.31" 1.42" 0.24"
36 6
1.42" 0.24" 52 500 44.5 New Products
2.05" 19.69" 1.75"
52 500 44.5
19.69" 1.75"
2.05" Fiberoptic
Sensors
EV-118USO (2066) EV-130MSO (2064)
Photoelectric
Toothed washer Sensors
Across-flats: 24 t=4 0.94" t= 0.16" Toothed washer
Across-flats: 36 t= 5 1.42" t= 0.20"
M18, P=1 Proximity
M30, P=1.5 Sensors
Operation indicator
Operation indicator
ø0.22" ø5.6, 2-core x 0.35 mm2
ø5.6 ø0.22" x 0.3 mm2
Cable length: 2 m 6.6' Safety
Equipment
ø15.5 ø14 ø14
ø0.61" ø0.55" ø0.55"
Flow/
12 Pressure/
39 7 Temperature
0.47" 1.54" 0.26"
38 6 44.5
1.50" 0.24" 56 1.75"
Measurement
54 500 44.5 2.20" Sensors
2.13" 19.69" 1.75"
Controls
AC 2-wire
EV-12M EV-18M EV-30M Static
Toothed washer Toothed washer Eliminators
Toothed washer
Across-flats: 24 t= 4 0.94" t= 0.16" Across-flats: 36 t= 5 1.42" t= 0.20"
Across-flats: 17 t= 4 0.67" t= 0.16"
M18, P=1 M30, P=1.5 Vision
M12, P=1 Operation indicator Systems
Operation indicator Operation indicator
ø0.23" ø5.9, 2-core x 0.5 mm
2 ø0.23"ø5.9, 2-core x 0.5 mm2
ø0.23" ø5.9, 2-core x 0.5 mm2 Marking
Cable length: 2 m 6.6' Cable length: 2 m 6.6'
Cable length: 2 m 6.6'
Equipment
Code Readers
36 6 36 6
1.42" 0.24" 1.42" 0.24" 39 7
52 52 1.54" 0.26" Handheld Mobile
2.05" 2.05" 56 Computers
2.20"
Microscopes
Projector/
3D Measurement
Systems