G60

G40
PEM Fuel Cell
Component Test Station
TM

FCATS

Power Range 1W 50 W 500 W 1 kW 10 kW 100 kW 250 kW

G20 G500
G40 G100/G200 G700
G60 G400 G900

• G40 power range: 1 - 50 W


• G60 power range: 10 - 500 W
• Automated safety features
• Emerald™ control and automation software
• Turn-key test system
• Minimal footprint
• Fully automated for unattended operation
• Optional configuration for high temperature PEM research
• Available CE certificate of conformity
G40/60 Features
• Small footprint The G40 and G60 are designed as sophisticated, customizable and flexible low flow
• Automatic N² purge on shutdown test stations. Over 200 FCATS™ test stations of this power range have been
• Integrated fume hood with H² sensor
successfully delivered worldwide.
• 2 separate PID loops for cell
endplate heaters Emerald™ : Our flexible control software features a user-friendly interface, and is
• Widescreen monitor and PC included
enhanced with our proprietary automation capability. The flexible Emerald™ scripting
• Ample 19" rack space
language allows complex script assembly within minutes for all types of users; from
• Generous workspace for the test
article with Dri-Dek® work surface novices to experts.

Additional options include:


• Liquid stack cooling capability
Emerald™ Process Screen
• DMFC operation
• Humidifier gas by-pass
• Lexan safety enclosure

Specifications
APPROXIMATE POWER RANGE G40: 1 - 50 W G60: 1 - 500 W
PERFORMANCE COMMITMENT:
At Greenlight, we pride ourselves on GAS FLOWS (custom ranges available) 100:1 turndown MFC’s

making the world’s best fuel cell Standard anode flow range G40: 0.015 - 1.5 nlpm G60: 0.1 - 10 nlpm
testing equipment. We are Standard cathode flow range G40: 0.025 - 2.5 nlpm G60: 0.2 - 20 nlpm
committed to your satisfaction and
GAS HUMIDIFICATION TECHNOLOGY contact humidifier or optional low flow bubbler
we will do whatever it takes to meet
or exceed your expectations. Dew point control up to 95˚C † (203˚F)† optional high temperature operation

Gas temperature up to 110˚C † (230˚F)† optional high temperature operation

Dry gas by-pass optional; with automatic control

Includes 3 levels of safety: ELECTRICAL END PLATE HEATER CONTROL included; with software PID

1. Hard-wired interlocks LIQUID CELL COOLING optional; manual or automatic flow control, high temp option available
2. Factory software interlocks CELL PRESSURE CONTROL automated
3. User-configurable software
Back pressure control up to 3barg† (45psig)†; higher pressures available
interlocks (warning high/low alarms
and shut-down high/low alarms) LOAD BANK
• N² purge
Maximum load, current, voltage 350W, 80A, 50V l 650W, 125A, 50V
• H² sensor
CELL VOLTAGE MONITORING
• Manual emergency stop
• Optional safety enclosure Standard number of channels up to 800 additional channels available (accuracy +/- 1mV)

DIMENSIONS (L x W x H) (approximate) 890 x 710 x 1855 mm (32 x 28 x 73 in)


† Dependent on actual operating conditions - higher temperature, pressure options available

© Greenlight Innovation Corporation, Burnaby, B.C. Canada. All specifications and illustrations contained in this brochure are
based on the latest product information available at the time of printing. Greenlight reserves the right to make changes at any
time without notice in materials, equipment, specifications and models. Printed in Canada.

104A - 3430 Brighton Avenue


Burnaby, B.C. Canada V5A 3H4
tel +1.604.676.4000
fax +1.604.676.4111
sales@greenlightinnovation.com
The Test and Automation Specialists: greenlightinnovation.com

Das könnte Ihnen auch gefallen