Beruflich Dokumente
Kultur Dokumente
Estación: YESERA
NORTE Lat. S.: 21º 22' 20''
Provincia: CERCADO Long. W.: 64º 33' 03''
Altura: 2.277
Departamento: TARIJA m.s.n.m.
AÑO ENE. FEB. MAR. ABR. MAY. JUN. JUL. AGO. SEP. OCT. NOV. DIC. MAXIMA
1977 33.7 37.0 42.0 10.0 9.0 0.6 0.0 19.0 10.5 16.0 30.0 12.3 42.0
1978 11.0 38.0 16.6 20.0 0.0 0.0 0.0 0.0 0.0 21.4 15.0 24.3 38.0
1979 53.2 26.3 23.6 9.4 2.5 12.5 10.0 0.0 2.2 20.0 19.4 27.3 53.2
1980 25.3 34.2 25.0 11.0 8.0 0.5 0.0 10.3 0.0 19.0 17.5 42.3 42.3
1981 50.0 73.0 34.0 15.3 1.5 1.0 2.5 4.0 3.5 4.0 15.0 55.2 73.0
1982 24.0 23.0 23.0 19.0 2.4 0.0 0.0 0.0 2.3 14.2 28.0 40.2 40.2
1983 35.2 27.0 10.0 4.0 3.3 0.0 5.5 1.5 11.0 20.0 18.0 15.0 35.2
1984 49.0 19.3 97.0 0.0 0.0 0.0 0.0 32.2 0.0 33.5 28.5 22.3 97.0
1985 19.3 43.0 27.5 20.0 3.0 0.0 1.5 14.0 5.3 35.0 46.0 40.0 46.0
1986 35.0 60.5 30.5 55.0 0.0 0.0 0.0 0.0 8.0 20.0 22.5 68.0 68.0
1987 48.2 26.5 21.0 28.4 0.0 0.0 0.0 0.0 0.0 16.3 46.2 24.0 48.2
PRECIPITACIÓN
AÑO
(mm)
1977 42.0
1978 38.0
1979 53.2
1980 42.3
1981 73.0
1982 40.2
1983 35.2
1984 97.0
1985 46.0
1986 68.0
1987 48.2
1988
1989
1990
1991 67.0
1992 52.0
1993 71.0
1994 49.5
1995 51.0
1996
1997 47.5
1998 55.0
1999 52.5
2000 69.0
2001 47.0
2002 59.0
2003 45.0
2004 30.0
2005 52.5
Promedio aritmético:
_
x=
∑x
Donde: n
_
x = Precipitación promedio en mm
n = Precipitación anual en mm
x = Numero de años correspondiente al periodo
_
x = 53.244 mm
Desviación Típica:
n ∑ x 2 −(∑ x ) 2
σ=
n(n − 1)
Donde:
x = Precipitación anual en mm
n = Numero de años correspondiente al periodo
σ = 14.528 mm
Moda:
_
Ed = x − 0,45 σ
Donde:
_
x = Precipitación anual en mm
n = Numero de años correspondiente al periodo
Ed = 46.706 mm
Característica:
σ
Kd =
0,557 Ed
Donde:
σ = Desviación típica en mm
E d = Moda en mm
K d = 0.558
hdt = Ed ∗ (1 + K d ∗ LogT )
Donde:
T = Periodo de retorno de 25 años
hdt = 83.169 mm
Tiempo de concentración:
El tiempo de concentración se calculará a partir de una media ponderada de las fórmulas de:
4 A + 1.5 ∗ L
tc = Giamdotti
25,3 ∗ J ∗ L
0.77
L
tc = 0,066 ∗ California
J
A
tc = 0,05 ∗ Ventura-Hera
J
0.385
L3
tc = 0.871∗
Chereque
H
Donde:
Tc = Tiempo de concentración en hrs
A = Área de la cuenca km2
L = Longitud entre alcantarillas o desagüe en km
J = Pendiente de la cuneta m/m
H = Desnivel máximo en m
Las precipitaciones máximas para 24 hrs. de duración y distintos periodos de retorno se
encontraran mediante la expresión propuesta por Ven Te Chow.
HT = u + KT
Donde:
HT = Precipitación máxima en 24 horas para distintos periodos de retorno
U = Media aritmética de la serie de observaciones
S = Desviación típica de la serie
KT = Factor de frecuencia que depende del periodo de retorno, responde a la Ley de
Gumbel, la formula es la siguiente
Intensidad máxima:
hdt
imax =
Tc
Donde:
imax = Intensidad máxima de la lluvia para un periodo de duración igual a Tc
hdt = Precipitación máxima diaria
Tc = Tiempo de concentración [hr]
Caudal maximo:
Con la fórmula racional determinamos el caudal que transportaran las cunetas:
Q = C * imax * A / 360
Donde:
Q = Caudal máximo de escorrentía [m3/seg.]
C = Coeficiente de escorrentía [adimensional]
imax = Intensidad máxima de la lluvia [mm/hr.]
A = Área de aporte [ha]
DISEÑO DE ALCANTARILLAS
Primeramente se determino la intensidad máxima y el caudal máximo para cada alcantarilla y
el diámetro de las alcantarillas de alivio fue determinado mediante la ecuación de Manning:
1 2 / 3 1/ 2
Q= R S A
n
Debido a que el tubo trabaja al 0,80 del diámetro (y = 0,8 d):
d2 d θ − Senθ
A= (θ R − Senθ ) R = R
8 4 θR
2y θπ
θ = 2 Cos -1 1 − θR =
d 180
Coeficiente de Manning
(n): 0.013 Alcantarilla rectangulares de concreto
Para una relación Y/D =
0,8
1 0+241.23 5.000 0.998 0.0288 0.252 0.315 1.00 Alcantarilla cuadrada 100x100cm
2 1+200.00 5.000 1.620 0.0291 0.353 0.441 1.00 Alcantarilla cuadrada 100x100cm
3 1+862.21 5.000 2.622 0.0185 0.597 0.746 1.00 Alcantarilla cuadrada 100x100cm
4 3+019.07 5.000 0.789 0.0195 0.245 0.306 1.00 Alcantarilla cuadrada 100x100cm
5 3+278.02 5.000 0.740 0.0246 0.216 0.270 1.00 Alcantarilla cuadrada 100x100cm
6 3+960.32 5.600 0.312 0.0137 0.148 0.184 1.00 Alcantarilla cuadrada 100x100cm
7 5+044.14 5.600 1.754 0.0846 0.256 0.320 1.00 Alcantarilla cuadrada 100x100cm
8 5+370.00 21.000 4.132 0.0800 0.088 0.088 0.53 Badem 21m de Largo
9 6+160.00 13.000 9.273 0.0984 0.172 0.172 0.33 Badem 13m de Largo
10 6+380.00 5.600 1.455 0.0246 0.347 0.434 1.00 Alcantarilla cuadrada 100x100cm
11 6+760.00 5.600 0.189 0.0165 0.100 0.125 1.00 Alcantarilla cuadrada 100x100cm
12 7+030.00 14.500 13.111 0.0778 0.211 0.211 0.36 Badem 14.5m de Largo
13 7+420.00 5.600 1.163 0.0293 0.278 0.348 1.00 Alcantarilla cuadrada 100x100cm
14 7+740.00 14.000 10.408 0.1177 0.168 0.168 0.35 Badem 14m de Largo
15 7+920.00 5.600 1.889 0.0346 0.370 0.463 1.00 Alcantarilla cuadrada 100x100cm
16 8+460.00 31.000 2.202 0.0661 0.051 0.051 0.78 Badem 31m de Largo
17 8+720.00 9.000 3.027 0.1176 0.105 0.105 0.23 Badem 9m de Largo
18 9+154.98 10.000 3.734 0.1100 0.114 0.114 0.25 Badem 10m de Largo
19 9+560.00 10.000 5.502 0.0981 0.146 0.146 0.25 Badem 10m de Largo
20 9+760.00 5.600 1.817 0.0135 0.509 0.637 1.00 Alcantarilla cuadrada 100x100cm
21 10+020.00 5.600 1.572 0.0146 0.444 0.555 1.00 Alcantarilla cuadrada 100x100cm
22 10+300.00 5.600 2.130 0.0170 0.526 0.658 1.00 Alcantarilla cuadrada 100x100cm
23 10+560.00 21.000 9.833 0.0593 0.160 0.160 0.53 Badem 21m de Largo
24 10+840.00 5.600 0.762 0.0135 0.272 0.339 1.00 Alcantarilla cuadrada 100x100cm
25 11+081.47 18.000 35.590 0.0360 0.407 0.407 0.45 Badem 18m de Largo
26 11+300.00 5.600 1.837 0.0214 0.433 0.541 1.00 Alcantarilla cuadrada 100x100cm
27 11+440.00 5.600 1.814 0.0186 0.451 0.564 1.00 Alcantarilla cuadrada 100x100cm
28 11+541.48 5.600 1.218 0.0192 0.334 0.417 1.00 Alcantarilla cuadrada 100x100cm
29 11+780.00 16.000 7.145 0.0482 0.163 0.163 0.40 Badem 16m de Largo
30 11+981.69 5.600 0.994 0.0236 0.269 0.336 1.00 Alcantarilla cuadrada 100x100cm
31 12+141.67 5.600 0.993 0.0246 0.265 0.331 1.00 Alcantarilla cuadrada 100x100cm
INTENSIDAD MAXIMA
Nº Prog. Longitud Area de aporte (km2) Pend. Desnivel Tiempo de concentración (hrs) Intensidad Coeficiente Caudal
km Del camino Del terreno Total m/m m Giamdotti California Ventura-Hera Chereque Promedio mm/hr Escorrentia m3/seg
1 0+241.23 0.869 0.0000 0.1355 0.1355 0.02876 25.00 4.390 0.232 0.109 0.234 1.241 66.290 0.400 0.998
2 1+200.00 0.654 0.0000 0.2199 0.2199 0.02907 19.00 5.942 0.186 0.138 0.187 1.613 66.290 0.400 1.620
3 1+862.21 1.104 0.0000 0.3560 0.3560 0.01850 20.42 7.824 0.331 0.219 0.333 2.177 66.290 0.400 2.622
4 3+019.07 0.462 0.0000 0.1071 0.1071 0.01948 9.00 8.792 0.166 0.117 0.167 2.311 66.290 0.400 0.789
5 3+278.02 0.284 0.0000 0.1005 0.1005 0.02465 6.99 9.576 0.104 0.101 0.105 2.471 66.290 0.400 0.740
6 3+960.32 0.219 0.0000 0.0423 0.0423 0.01370 3.00 15.180 0.107 0.088 0.107 3.870 66.290 0.400 0.312
7 5+044.14 0.709 0.0000 0.2382 0.2382 0.08463 59.99 1.987 0.131 0.084 0.132 0.583 66.290 0.400 1.754
8 5+370.00 0.749 0.0000 0.5610 0.5610 0.08000 59.92 2.717 0.140 0.132 0.140 0.782 66.290 0.400 4.132
9 6+160.00 1.630 0.0000 1.2590 1.2590 0.09844 160.46 1.708 0.235 0.179 0.236 0.589 66.290 0.400 9.273
10 6+380.00 0.605 0.0000 0.1975 0.1975 0.02464 14.91 7.119 0.187 0.142 0.188 1.909 66.290 0.400 1.455
11 6+760.00 0.789 0.0000 0.0256 0.0256 0.01649 13.01 5.541 0.267 0.062 0.269 1.535 66.290 0.400 0.189
12 7+030.00 2.318 0.0000 1.7800 1.7800 0.07778 180.29 1.932 0.337 0.239 0.339 0.712 66.290 0.400 13.111
13 7+420.00 0.803 0.0000 0.1580 0.1580 0.02931 23.54 4.693 0.217 0.116 0.218 1.311 66.290 0.400 1.163
14 7+740.00 1.532 0.0000 1.4130 1.4130 0.11768 180.29 1.546 0.209 0.173 0.210 0.535 66.290 0.400 10.408
15 7+920.00 0.986 0.0000 0.2565 0.2565 0.03457 34.08 4.064 0.238 0.136 0.240 1.170 66.290 0.400 1.889
16 8+460.00 0.993 0.0000 0.2990 0.2990 0.06608 65.62 2.215 0.187 0.106 0.188 0.674 66.290 0.400 2.202
17 8+720.00 0.374 0.0000 0.4110 0.4110 0.11759 43.98 2.809 0.071 0.093 0.071 0.761 66.290 0.400 3.027
18 9+154.98 0.571 0.0000 0.5070 0.5070 0.11001 62.81 2.331 0.100 0.107 0.101 0.660 66.290 0.400 3.734
19 9+560.00 1.208 0.0000 0.7470 0.7470 0.09814 118.55 1.757 0.187 0.138 0.188 0.567 66.290 0.400 5.502
20 9+760.00 0.798 0.0000 0.2467 0.2467 0.01350 10.77 11.684 0.291 0.214 0.293 3.120 66.290 0.400 1.817
21 10+020.00 0.562 0.0000 0.2135 0.2135 0.01459 8.20 12.970 0.216 0.191 0.217 3.398 66.290 0.400 1.572
22 10+300.00 0.874 0.0000 0.2892 0.2892 0.01695 14.82 9.235 0.286 0.207 0.287 2.504 66.290 0.400 2.130
23 10+560.00 1.252 0.0000 1.3350 1.3350 0.05934 74.29 3.458 0.233 0.237 0.234 1.041 66.290 0.400 9.833
24 10+840.00 0.863 0.0000 0.1035 0.1035 0.01346 11.61 8.786 0.309 0.139 0.311 2.386 66.290 0.400 0.762
25 11+081.47 2.619 0.0000 4.8320 4.8320 0.03596 94.18 5.339 0.498 0.580 0.501 1.730 66.290 0.400 35.590
26 11+300.00 0.879 0.0000 0.2495 0.2495 0.02137 18.78 6.979 0.263 0.171 0.264 1.919 66.290 0.400 1.837
27 11+440.00 0.654 0.0000 0.2463 0.2463 0.01864 12.19 9.620 0.221 0.182 0.222 2.561 66.290 0.400 1.814
28 11+541.48 0.845 0.0000 0.1653 0.1653 0.01923 16.25 7.038 0.265 0.147 0.267 1.929 66.290 0.400 1.218
29 11+780.00 2.014 0.0000 0.9700 0.9700 0.04821 97.09 2.834 0.364 0.224 0.366 0.947 66.290 0.400 7.145
30 11+981.69 0.963 0.0000 0.1350 0.1350 0.02364 22.77 5.058 0.271 0.119 0.273 1.430 66.290 0.400 0.994
31 12+141.67 0.689 0.0000 0.1349 0.1349 0.02464 16.98 5.826 0.206 0.117 0.207 1.589 66.290 0.400 0.993
DISEÑO DE CUNETAS
Con la ecuación de Manning determinamos el área hidráulica:
1 2 / 3 1/ 2
Q= R S A
n
Para una sección triangular de las siguientes características:
A = y2 T = 2y
(
RH = y / 2 2 ) P = 2 2y
Donde:
Q = Caudal máximo de escorrentía [m3/seg.]
n = Coeficiente de Manning [adimensional]. Se adoptó 0,025 para superficie de tierra
del libro Hidráulica de Canales de Máximo Villón B., Pág. 70
R = Radio hidráulico [m]
S = Pendiente longitudinal [m/m]
A = Área hidráulica [m2]
Además se debe tomar en cuenta un borde libre de 7 cm y cuidar que la velocidad del agua no
sobrepase los 1,10 m/seg, para canales de tierra, y un máximo de 2,00 m/seg, para canales en
roca.
Con estas limitantes se llegaron a encontrar las dimensiones de ancho y alto de la sección
triangular para cada tramo:
DISEÑO DE CUNETAS (CANAL TRIANGULAR)
MEJORAMINETO CAMINO: SAN ROQUE - CHIGUAYPOLLA
Canales de tierra, alineados y uniformes
Coeficiente de Manning Porcentaje de error
(n): 0.025 (%): 1%
Talud del lado
Talud al lado del camino: exterior:
Horizontal: 1 Horizontal: 1
Vertical: 1 Vertical: 1
Como en la práctica es imposible construir secciones diferentes para cada tramo se tomara una
sección tipo de ancho 106.00 cm y alto 30.00 cm; teniendo en cuenta siempre el terreno
natural del lugar (tierra o roca).
SECCIÓN TIPO
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Lugar: Proyecto:
Tramo: Revestimiento:
Talud (Z):
Rugosidad (n):
Tipo de flujo:
Cuneta Nº1
Worksheet for Irregular Channel
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.081000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.15 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.10 m
Flow Area 0.07 m²
Wetted Perimeter 0.90 m
Top Width 0.70 m
Height 0.20 m
Critical Depth -0.03 m
Critical Slope 0.016526 m/m
Velocity 2.08 m/s
Velocity Head 0.22 m
Specific Energy 0.12 m
Froude Number 2.11
Flow is supercritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.036000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.07 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.13 m
Flow Area 0.05 m²
Wetted Perimeter 0.77 m
Top Width 0.61 m
Height 0.17 m
Critical Depth -0.10 m
Critical Slope 0.018372 m/m
Velocity 1.26 m/s
Velocity Head 0.08 m
Specific Energy -0.05 m
Froude Number 1.37
Flow is supercritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.040000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.05 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.14 m
Flow Area 0.04 m²
Wetted Perimeter 0.70 m
Top Width 0.55 m
Height 0.16 m
Critical Depth -0.12 m
Critical Slope 0.018871 m/m
Velocity 1.25 m/s
Velocity Head 0.08 m
Specific Energy -0.06 m
Froude Number 1.42
Flow is supercritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.053000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.32 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.01 m
Flow Area 0.15 m²
Wetted Perimeter 1.31 m
Top Width 1.03 m
Height 0.29 m
Critical Depth 0.06 m
Critical Slope 0.015953 m/m
Velocity 2.17 m/s
Velocity Head 0.24 m
Specific Energy 0.23 m
Froude Number 1.81
Flow is supercritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.033000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.08 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.11 m
Flow Area 0.06 m²
Wetted Perimeter 0.85 m
Top Width 0.67 m
Height 0.19 m
Critical Depth -0.09 m
Critical Slope 0.017876 m/m
Velocity 1.28 m/s
Velocity Head 0.08 m
Specific Energy -0.03 m
Froude Number 1.33
Flow is supercritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.027000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.05 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.13 m
Flow Area 0.05 m²
Wetted Perimeter 0.74 m
Top Width 0.58 m
Height 0.17 m
Critical Depth -0.12 m
Critical Slope 0.019015 m/m
Velocity 1.06 m/s
Velocity Head 0.06 m
Specific Energy -0.08 m
Froude Number 1.18
Flow is supercritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.018000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.13 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.04 m
Flow Area 0.11 m²
Wetted Perimeter 1.15 m
Top Width 0.90 m
Height 0.26 m
Critical Depth -0.04 m
Critical Slope 0.016733 m/m
Velocity 1.16 m/s
Velocity Head 0.07 m
Specific Energy 0.02 m
Froude Number 1.03
Flow is supercritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.068000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.05 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.16 m
Flow Area 0.03 m²
Wetted Perimeter 0.62 m
Top Width 0.49 m
Height 0.14 m
Critical Depth -0.12 m
Critical Slope 0.019013 m/m
Velocity 1.50 m/s
Velocity Head 0.11 m
Specific Energy -0.05 m
Froude Number 1.82
Flow is supercritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.028000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.08 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.11 m
Flow Area 0.07 m²
Wetted Perimeter 0.87 m
Top Width 0.69 m
Height 0.19 m
Critical Depth -0.09 m
Critical Slope 0.017907 m/m
Velocity 1.20 m/s
Velocity Head 0.07 m
Specific Energy -0.03 m
Froude Number 1.23
Flow is supercritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.020000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.04 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.14 m
Flow Area 0.04 m²
Wetted Perimeter 0.70 m
Top Width 0.55 m
Height 0.16 m
Critical Depth -0.14 m
Critical Slope 0.019776 m/m
Velocity 0.88 m/s
Velocity Head 0.04 m
Specific Energy -0.10 m
Froude Number 1.01
Flow is supercritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.015000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.03 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.14 m
Flow Area 0.04 m²
Wetted Perimeter 0.71 m
Top Width 0.56 m
Height 0.16 m
Critical Depth -0.15 m
Critical Slope 0.020069 m/m
Velocity 0.77 m/s
Velocity Head 0.03 m
Specific Energy -0.11 m
Froude Number 0.87
Flow is subcritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.027000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.11 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.08 m
Flow Area 0.09 m²
Wetted Perimeter 0.99 m
Top Width 0.78 m
Height 0.22 m
Critical Depth -0.06 m
Critical Slope 0.017142 m/m
Velocity 1.29 m/s
Velocity Head 0.08 m
Specific Energy 0.01 m
Froude Number 1.24
Flow is supercritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.070000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.06 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.16 m
Flow Area 0.04 m²
Wetted Perimeter 0.65 m
Top Width 0.51 m
Height 0.14 m
Critical Depth -0.12 m
Critical Slope 0.018734 m/m
Velocity 1.56 m/s
Velocity Head 0.12 m
Specific Energy -0.03 m
Froude Number 1.85
Flow is supercritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.070000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.03 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.18 m
Flow Area 0.02 m²
Wetted Perimeter 0.53 m
Top Width 0.42 m
Height 0.12 m
Critical Depth -0.15 m
Critical Slope 0.020072 m/m
Velocity 1.37 m/s
Velocity Head 0.10 m
Specific Energy -0.09 m
Froude Number 1.80
Flow is supercritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.011000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.06 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.10 m
Flow Area 0.07 m²
Wetted Perimeter 0.90 m
Top Width 0.71 m
Height 0.20 m
Critical Depth -0.12 m
Critical Slope 0.018824 m/m
Velocity 0.77 m/s
Velocity Head 0.03 m
Specific Energy -0.07 m
Froude Number 0.78
Flow is subcritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.009000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.02 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.17 m
Flow Area 0.03 m²
Wetted Perimeter 0.59 m
Top Width 0.46 m
Height 0.13 m
Critical Depth -0.19 m
Critical Slope 0.022191 m/m
Velocity 0.53 m/s
Velocity Head 0.01 m
Specific Energy -0.15 m
Froude Number 0.66
Flow is subcritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.040000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.03 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.17 m
Flow Area 0.03 m²
Wetted Perimeter 0.57 m
Top Width 0.45 m
Height 0.13 m
Critical Depth -0.16 m
Critical Slope 0.020320 m/m
Velocity 1.08 m/s
Velocity Head 0.06 m
Specific Energy -0.11 m
Froude Number 1.37
Flow is supercritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.027000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.02 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.18 m
Flow Area 0.03 m²
Wetted Perimeter 0.54 m
Top Width 0.43 m
Height 0.12 m
Critical Depth -0.17 m
Critical Slope 0.021269 m/m
Velocity 0.86 m/s
Velocity Head 0.04 m
Specific Energy -0.14 m
Froude Number 1.12
Flow is supercritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.047000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.02 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.20 m
Flow Area 0.02 m²
Wetted Perimeter 0.45 m
Top Width 0.36 m
Height 0.10 m
Critical Depth -0.18 m
Critical Slope 0.021847 m/m
Velocity 1.01 m/s
Velocity Head 0.05 m
Specific Energy -0.15 m
Froude Number 1.43
Flow is supercritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.015000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.04 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.13 m
Flow Area 0.05 m²
Wetted Perimeter 0.77 m
Top Width 0.61 m
Height 0.17 m
Critical Depth -0.14 m
Critical Slope 0.019514 m/m
Velocity 0.81 m/s
Velocity Head 0.03 m
Specific Energy -0.10 m
Froude Number 0.88
Flow is subcritical.
Project Description
Project File untitled.fm2
Worksheet Alcantarilla Nº1
Flow Element Irregular Channel
Method Manning's Formula
Solve For Water Elevation
Input Data
Channel Slope 0.050000 m/m
Elevation range: -0.3 m to 0.0 m.
Station (m) Elevation (m) Start Station End Station Roughness
0.00 0.00 0.00 1.06 0.025
1.00 -0.30
1.06 0.00
Discharge 0.03 m³/s
Results
Wtd. Mannings Coefficient 0.025
Water Surface Elevation -0.19 m
Flow Area 0.02 m²
Wetted Perimeter 0.51 m
Top Width 0.40 m
Height 0.11 m
Critical Depth -0.17 m
Critical Slope 0.020802 m/m
Velocity 1.13 m/s
Velocity Head 0.06 m
Specific Energy -0.12 m
Froude Number 1.51
Flow is supercritical.