Beruflich Dokumente
Kultur Dokumente
CFRP
Ef 165000 MPA
Ffu 2900 MPA
FRP strength reduction factor 0.85
Environmental reduction factor CE 0.95
Af
No. of the CFRP strips 8
No. of plies (layers) n 2
tf 1.2 mm
width wrap Wf 100 mm
Afv 1920 mm2
H 1750 mm
B 500 mm
C 20 mm
d 1730 mm
T 150 mm
Ec 29913.7 MPA
ns 6.6859
nf 5.51587
fc 40 MPA
As 1960 mm2
Ɛbi 0.00070804
Ɛfd 0.004120655
Ɛfe 0.004120655 ACI 440.2R-0810-16,17
Ɛc 0.000966109
Ɛc' 0.002273207
Ɛs 0.004762469 ACI 440.2R-08 10-10
reinforcement
as follows:
ρs= 0.002240
ρf= 0.002194
K= 0.207809
Kd= 359.5 mm
Af
No. of the CFRP strips 10
No. of plies (layers) n 1
tf 1.2 mm
width wrap Wf 100 mm
Afv 1200 mm2
H 1750 mm
B 500 mm
C 20 mm
d 1730 mm
T 150 mm
Ec 29913.7 MPA
ns 6.6859
nf 5.51587
fc 40 MPA
As 1960 mm2
As 3920 mm2
Ɛbi 0.000520577
Ɛfd 0.005827486
Ɛfe 0.005827486 ACI 440.2R-0810-16,17
Ɛc 0.001313763
Ɛc' 0.002273207
Ɛs 0.006260499 ACI 440.2R-08 10-10
reinforcement
as follows:
ρs= 0.004480
ρf= 0.001371
K= 0.239281
Kd= 414.0 mm
Calculate the stress level in the reinforcing
steel using Eq. (10-14) and verify that it is less
than the recommended limit per Eq. (10-6).