Sie sind auf Seite 1von 8

1- GRB15-2 (B500x1750)(left and right)

CFRP
Ef 165000 MPA
Ffu 2900 MPA
FRP strength reduction factor 0.85
Environmental reduction factor CE 0.95

Manufacturer rupture strain Ɛfu 0.017575758


Manufacturer design strain Ɛfu 0.01669697

Af
No. of the CFRP strips 8
No. of plies (layers) n 2
tf 1.2 mm
width wrap Wf 100 mm
Afv 1920 mm2

H 1750 mm
B 500 mm
C 20 mm
d 1730 mm
T 150 mm
Ec 29913.7 MPA
ns 6.6859
nf 5.51587
fc 40 MPA
As 1960 mm2
Ɛbi 0.00070804
Ɛfd 0.004120655
Ɛfe 0.004120655 ACI 440.2R-0810-16,17

Ɛc 0.000966109
Ɛc' 0.002273207
Ɛs 0.004762469 ACI 440.2R-08 10-10

fs 420 mpa ACI 440.2R-08 10-11

ffe 679.908082 mpa ACI 440.2R-08 10-9

β1 0.694174631 ACI 318-05

α1 0.525502443 ACI 318-05

c 291.7597534 ok ACI 440.2R-0810-12

Mns 1340.773739 Kn.m


Mnf 2152.295995 Kn.m
φ 0.879523197
φMn= 2788.286722 Kn.m

Use 16 strip in 2 layers sika carbadur S1012


Check service stresses in the
reinforcing steel and the FRP
Calculate the elastic depth to the cracked
neutral axis. This can be simplified for a
rectangular beam without compression

reinforcement
as follows:

ρs= 0.002240
ρf= 0.002194

K= 0.207809
Kd= 359.5 mm

Calculate the stress level in the reinforcing


steel using Eq. (10-14) and verify that it is less
than the recommended limit per Eq. (10-6).

fss= 445.8248775 ≤ 336 ok

Check creep rupture limit at service of the FRP

Calculate the stress level in the FRP using


Eq. (10-15) and verify that it is less than
creep-rupture stress limit given in
Table 10.1. Assume that the full service load
is sustained.

ffs= 163.2 ≤ 1515.25 ok


GRB15-2 (B500x1750)(middle)
CFRP
Ef 165000 MPA
Ffu 2900 MPA
FRP strength reduction factor 0.85 p7
Environmental reduction factor CE 0.95 p24

Manufacturer rupture strain Ɛfu 0.017575758


Manufacturer design strain Ɛfu 0.01669697

Af
No. of the CFRP strips 10
No. of plies (layers) n 1
tf 1.2 mm
width wrap Wf 100 mm
Afv 1200 mm2

H 1750 mm
B 500 mm
C 20 mm
d 1730 mm
T 150 mm
Ec 29913.7 MPA
ns 6.6859
nf 5.51587
fc 40 MPA
As 1960 mm2

As 3920 mm2
Ɛbi 0.000520577
Ɛfd 0.005827486
Ɛfe 0.005827486 ACI 440.2R-0810-16,17

Ɛc 0.001313763
Ɛc' 0.002273207
Ɛs 0.006260499 ACI 440.2R-08 10-10

fs 420 mpa ACI 440.2R-08 10-11

ffe 961.5352308 mpa ACI 440.2R-08 10-9

β1 0.706435315 ACI 318-05

α1 0.660496383 ACI 318-05

c 300.0701305 ok ACI 440.2R-0810-12

Mns 2673.769951 Kn.m


Mnf 1896.928163 Kn.m
φ 0.9
φMn= 3857.543 Kn.m

Use 10 strip in 1 layer sika carbadur S1012


Check service stresses in the
reinforcing steel and the FRP
Calculate the elastic depth to the cracked
neutral axis. This can be simplified for a
rectangular beam without compression

reinforcement
as follows:

ρs= 0.004480
ρf= 0.001371

K= 0.239281
Kd= 414.0 mm
Calculate the stress level in the reinforcing
steel using Eq. (10-14) and verify that it is less
than the recommended limit per Eq. (10-6).

fss= 268.6185241 ≤ 336 ok


Check creep rupture limit at service of the FRP

Calculate the stress level in the FRP using


Eq. (10-15) and verify that it is less than
creep-rupture stress limit
given in
Table 10.1. Assume that the full service load
is sustained.

ffs= 117.7 ≤ 1515.25 ok