Sie sind auf Seite 1von 18

PCSVN1602A

Warning Ask a qualified installer or contractor to install this product. Do not try to install the product by yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the user's manual carefully before using this product. The user's manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.

Air Conditioning System


Heat pump 50Hz

Specifications, designs and other content appearing in this brochure are current as of December 2016 but subject to change without notice.

c All rights reserved 12/16 SS


Daikin meets your needs with the line up of various types of indoor units and power supplies

CEILING MOUNTED CEILING SUSPENDED DUCT CONNECTION FLOOR STANDING


CASSETTE TYPE TYPE MIDDLE STATIC TYPE
PRESSURE TYPE

Product Lineup Heat pump


Series 71 100 125 140
CEILING MOUNTED
CASSETTE TYPE
Round Flow
Page 3 Indoor unit FCQ71KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA
Outdoor unit RQ71MV1 RQ71MY1 RQ100MV1 RQ100MY1 RQ125MY1 RQ140MY1

CEILING SUSPENDED TYPE

Page 7 Indoor unit FHQ71DAVMA FHQ100DAVMA FHQ125DAVMA FHQ140DAVMA


Outdoor unit RQ71MY1 RQ100MY1 RQ125MY1 RQ140MY1

DUCT CONNECTION
MIDDLE STATIC
PRESSURE TYPE
Page 9 Indoor unit FBQ71EVE FBQ100EVE FBQ125EVE FBQ140EVE
Outdoor unit RQ71MV1 RQ71MY1 RQ100MV1 RQ100MY1 RQ125MY1 RQ140MY1

FLOOR STANDING TYPE

Page 11 Indoor unit FVQ71CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB


Outdoor unit RQ71MV1 RQ71MY1 RQ100MV1 RQ100MY1 RQ125MY1 RQ140MY1

OUTDOOR UNIT
1 Phase 50Hz
220-230V

Page 13
Outdoor unit RQ71MV1 RQ100MV1

3Phase 50Hz
380-415V

Page 13
Outdoor unit RQ71MY1 RQ100MY1 RQ125MY1 RQ140MY1

1 2
CEILING MOUNTED CASSETTE TYPE Round Flow

Cassette air conditioner with 360° Avoids uneven temperature and discomfort caused by drafts

Comfort enhanced by Round Flow!


uniform airflow sets the standard 360° airflow Air movement is gentle
FCQ71/100/125/140KA With uniform temperature with Round Flow
distribution Enhanced Comfort
360° airflow can
maintain comfort
Airflow even if air
distribution discharge speed is
creates uniform lower.
comfort throughout
the space.
Velocity decreases by
25% when set
Room remains temperature is raised
comfortable even 1℃ to 1.5℃.
when set
Greater comfort temperature is
raised 1℃.

Option
Accessory required for indoor unit. Adapts easily to the installation space
Navigation Remote Controller Because air flows out from corner outlets, comfort spreads more widely
(Wired Remote Controller)
Typical flow patterns There are a total of 23 flow patterns.

BRC1E62 All-round flow 3-way flow


L-shaped Opposite
2-way flow 2-way flow
Note: Remote controller cable is not
included and must be procured
locally.

Wired LCD remote controller (E.g., installed in (E.g., installed (E.g., installed in (E.g., installed in
middle of ceiling) near a wall) a corner) a long room)
BRC1C61 4-way flow also possible.
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to
Note: Remote controller cable is not
close each unused outlet.
included and must be procured
locally. Operation sound increases when using 2-way or 3-way flow.

Grime prevention and antibacterial coating: Make cleaning easier


Wireless LCD remote controller
A signal receiver must be added to the indoor unit.
External panels are treated with a coating that
Heat pump BRC7F634F
repels dirt Treated
surface
Untreated
surface
To prevent dirt sticking to the
Signal receiver unit external panels, they have Resists
(Installed type) soiling
been coated with a surface Grimy
• Condition after exposure
to the smoke of 600
Wireless remote controller is supplied in a
set with a signal receiver.
treatment surface cigarettes in 1 m3
enclosed space.

Silver ion anti-bacterial Non-flocking flaps Filter has anti-mould and


drain pan antibacterial treatment
A built-in antibacterial treatment that uses Condensation does not easily form on Prevents mould and microorganisms
silver ion in the drain pan prevents and dirt does not cling to non-flocking growing out of the dust and moisture
the growth of slime, bacteria, and mould flaps. that adheres to the filters.
that cause smells and clogging. It is easy to clean.
3 4
CEILING MOUNTED CASSETTE TYPE Round Flow

Unified square panels Compact body and quiet operation Easier to maintain
Panel size is the same for all models, FCQ71-140KA. dB(A)
It is easy to maintain a neat appearance when multiple
Indoor unit
Sound pressure level The condition of the drain pan and the
open
units are installed in the same room.
High Middle Low drain water can be checked by Just on grille
!
71KA 35 31.5 28 c t i
mm 95 removing the drain plug and su
950 0m
Same for 100KA 43 37.5 32 Drain plug
m
125KA 44 39 34 suction grille
all models
140KA 44 40 36
With Ultra long-life filters (option), maintenance is not required in normal shops or offices
for up to four years
Optimal comfort and convenience Quick and easy to install
assured by 2 air discharge modes Just 256 mm high. Installable in tight
ceiling spaces (71KA)
Options required for specific operating environments

Air direction Standard setting1


Setting to prevent soiling Ultra long-life filter unit Sealing material of air discharge outlet
of ceiling2 (field setting)
Even in dusty environments where the air Sealing material block air discharge openings not used in 2-way or
Standard setting to Recommended for shops with 256 mm *1 266 mm *2 conditioning is on most of the time, the ultra long-life 3-way blow.
Desired light coloured ceilings that
situation prevent draft. must be kept spotless. filter only has to be cleaned once a year.
Filter chamber
Branch duct (direct-connection round duct)
*1 298 mm high with 100–140KA (Can be used with high-efficiency filter)
A round duct can be attached without the need for a chamber.
Auto-swing Auto-swing between Auto-swing between *2 308 mm high with 100–140KA A flanged port for direct connection of a round duct is provided. An
15° and 60° 25° and 60° existing branch duct chamber can also be fitted (square slit hole).
5-levels Easy height adjustment Ultra long-life filter Fresh air intake kit Note 1.2
air direction Outside
setting
Settable to 5 different Settable to 5 different Each corner of the Using this kit, a duct can be
levels between 15° and 60° levels between 25° and 60° Dusty area: annual filter change
unit has an Adjuster connected to take outdoor air
At heating startup and thermo OFF, air discharge Pocket that lets you *For dust concentration of 0.3 mg/m3 (Requires separately sold Air purifier.)
1 year (Approx. 5,000 hr) 15 hr/day x 28 day/month x 12 month/year in.There are two chamber types that
Draft prevention is automatically set to a near horizontal 25˚ or 30˚ easily adjust the
(In heating mode) have intake in two places: with
to prevent direct exposure to cool air drafts. unit's suspended Ordinary store or office: filter change every 4 years
T-duct joint and without T-duct joint.
height. *For dust concentration of 0.15 mg/m3
4 years (Approx. 10,000 hr) 8 hr/day x 25 day/month x 12 month/years
Auto air The air direction is set automatically to the
x 4 years The units can be installed in the following different ways.
Note:
direction control memorised position of the previous air direction.
If the wireless remote Chamber type (without T-duct joint) Note 3.4

Note:
controller is installed, a signal
receiver unit is housed in one
High-efficiency filter unit KDDP55B160
1
Air direction is set to the standard position when the unit is shipped from the factory. The of the adjuster pockets. Available in two types: 65% and 90% colorimetry. Flexible duct
position can be changed from the remote controller. (procured locally)
2
Closing of the corner discharge outlets is recommended. Filter chamber
T-duct joint
(Can be used with ultra long-life filter)
All models can be installed without Suction
(procured locally)

Suitable for high ceilings


Intake duct
using lifter because of the light weight chamber
(procured locally)
(duct length: 4 m max.)
Connection
Even in spaces with Standard Setting Setting High-efficiency filter chamber
high ceilings, a
comfortable airflow is
Installed in any direction Chamber type (with T-duct joint) Note 3.4
carried down to Since the orientation of
the floor level. 4.2 the suction grille can Insulation kit for high humidity KDDP55B160K

3.2 3.6 be adjusted after Please use if you think the temperature and humidity
m m Flexible duct
m installing, the direction inside the ceiling exceeds 30°C and RH 80%,
of the suction grille respectively. T-duct joint
lines can be unified Suction
when multiple units Top panel insulation(1) chamber Intake duct
(procured locally)
When all round flow is selected, ceilings up to 4.2 m in height can be are installed. Top panel insulation(2) Connection (duct length: 4 m max.)
accommodated. (100-140KA) Top panel insulation(3)
chamber

Insulation for decoration panel Direct installation type


Side panel insulation
Criteria for ceiling height and number of air discharge outlets Drain pump is Suspension bracket insulation KDDP55X160A
(Ceiling height is reference value)
equipped as
Number of air discharge outlets used
standard 850 mm
71KA 100–140KA Panel spacer
All round 4-way 3-way 2-way All round 4-way 3-way 2-way accessory with 175 mm Use when only minimal space is available between Duct flange
flow flow flow flow flow flow flow flow
Standard 2.7 m 3.1 m 3.0 m 3.5 m 3.2 m 3.4 m 3.6 m 4.2 m 850 mm lift drop ceilings and ceiling slabs.
(with insulation material)
Intake duct
Ceiling (procured locally)
High ceiling 3.0 m 3.4 m 3.3 m 3.8 m 3.6 m 3.9 m 4.0 m 4.2 m
height
High ceiling 3.5 m 4.0 m 3.5 m - 4.2 m 4.5 m 4.2 m -
Note: Factory settings are for standard ceiling height and all-round flow.
High ceiling settings (1) and (2) are set with the remote controller by field setting. Transparent drain socket Note: 1 Use of options will increase operating sound.
2 Connecting ducts, fan, insect nets, fire dampers, air filters, and other parts
40mm should, as required, be procured locally.
Panel spacer 3 When a local-procured fan is used, an interlock with air conditioner is
Two selectable temperature-sensors See page 19 necessary.Optional PCB(KRP1C63)is required for interlocking.
4 It is recommended that the volume of outdoor air introduced through the kit is
DIII-NET communication standard Note: Some ceiling constructions may hinder installation.
limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher
Switchable fan speed: High/Middle/Low Connection to a centralised control system
Contact your Daikin Dealer before installing your unit.
quantities will increase the operating sound and may also influence temperature
sending.
Control of airflow rate has been improved from 2-step to 3-step. is available without option.
5 6
CEILING SUSPENDED TYPE

Comfortable airflow travels The latest stylish


model
Installation flexibility for
freedom of design
throughout the room Sophisticated
design
Flexible installation
The unit fits more snugly 30 mm 30 mm
Flap neatly closes into tight spaces. or more or more

FHQ71/100/125/140DA when not in use. *Water used in the test-run can be drained from the air
discharge opening rather than from the side as was
formerly the case.
White colour
Drain pump kit (option) can 600
mm
be easily incorporated

Comfortable Drain pipe connection can be done


inside the unit. Refrigerant and drain
pipe outlets are at the same opening.
Drain pump kit
(built inside
the unit)
The technology of the DC fan motor, wide
sirocco fan, and large heat exchanger DIII-NET communication standard
combine for greater airflow and quiet Connection to a centralised control system is available without
operation option.

All wiring and internal servicing can be done


Option
Auto swing (up and down) and louvers from under the unit
Accessory required for indoor unit.
(left and right by hand) bring comfort to Easier piping work for
Navigation Remote Controller the room
(Wired Remote Controller) rear side by removable
frame
BRC1E62 Louver manually adjusts for straight or
wide angle airflow
Note: Remote controller cable is not
included and must be procured
locally.
Easy maintenance
Drain pump kit (option) includes a silver ion
Wired LCD remote controller antibacterial agent that assists in preventing
the growth of slime, bacteria, and mould that
BRC1C61 cause smells and clogging
Note: Remote controller cable is not
included and must be procured
locally. Non-flocking flap
Suitable for high ceilings Condensation does not easily form on and
dirt does not cling to non-flocking flap.
It is easy to clean.
Wireless LCD remote controller Non-flocking flap

A signal receiver must be added to the indoor unit.


4.3
3.5 m
m Easy-clean, flat surfaces
Heat pump BRC7GA53 It is easy to wipe dirt off the flat side and lower surfaces of the unit.

71DA 100-140DA

71DA 100DA 125/140DA Quiet operation dB(A)


Standard 2.7m or less 3.8m or less 4.3m or less
Signal receiver unit (Installed type)
High ceiling 2.7m~3.5m 3.8m~4.3m - Sound pressure level
Wireless remote controller is supplied in Indoor unit
a set with a signal receiver. High Middle Low
Note: Factory settings is “standard”.
“High ceiling” are set with remote controller by field setting. 71DA 38 36 34
100DA 42 38 34
125DA 44 41 37
140DA 46 42 38
Two selectable temperature-sensors
See page 19

Switchable fan speed: High/Middle/Low


Oil resistant grille
Oil-resistant plastic is used for the air suction grille. This satisfies
durability in restaurants and other similar environments.
Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification
Programme "Dry" See page 19 is not suitable for kitchens or other harsh environments.

7 8
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

Thinner design allows greater Design and installation Using a DC fan motor, the external static
pressure can be controlled to within a range

installation flexibility flexibility


With a height of only 245 mm, installation is
of 50 Pa to 150 Pa
Adjustable external static pressure

FBQ71/100/125/140E
possible even in buildings with narrow ceiling 50 Pa 150 Pa
spaces
Set to low static Set to high static pressure for

245mm pressure when ducts


are short.
advanced needs such as when
using dampers and long ducts.

Comfort airflow is achieved in accordance with conditions such


One of the industry’s most compact bodies as duct length.
in the mid-static pressure range.
Indoor unit 71E 100/125/140E Airflow rate auto adjustment function
Height 245
Controls the airflow rate using a remote controller during test run.
(mm)

Width (mm) 1,000 1,400 It is automatically adjusted to approximately ±10% of the rated H
Depth (mm) 800 tap airflow.

Higher lift is realized by utilising built-in DC


Interlock control
Option drain pump with standard accessory As an energy saving feature, the room air conditioning unit can be
Accessory required for indoor unit. interlocked with the hotel key card system.
Middle & High static
Navigation Remote Controller pressure type Using a 3rd-party building
(Wired Remote Controller)
850mm (FBQ-D series) management system, air
conditioning and lighting can
700mm be interlocked. Interlock
BRC1E62 * Field setting with remote
controller
Note: Remote controller cable is not
included and must be procured
Bottom suction is available
locally.
Wiring and servicing
can be done from the unit
DIII-NET communication standard
joist
underside of the unit (an Easier communication and connection with the centralised control
option part required). system.
Wired LCD remote controller Air suction
ceiling

BRC1C61
Note: Remote controller cable is not
included and must be procured
Rear suction Bottom suction
Easy maintenance
Air suction flange Sield plate for side plate(option)
locally.
Position of drain pan inspection opening has
been modified for easier inspection work

Wireless LCD remote controller Drain pan maintenance check window


A signal receiver must be added to the indoor unit.
This makes it possible
Control box to inspect for drain pan
BRC4C65
Switch bottom plate with
Heat pump cover Bottom Air suction
plate
air suction flange.
flange dirt and to confirm Inspection
Make the control box Bottom plate opening for
face inward. drainage during drain pan
installation without the Drain pan
Signal receiver unit use of tools. maintenance
(Separate type) check window

Wireless remote controller is supplied in a


set with a signal receiver. Easy maintenance because the drain
Control box faces outward.
Control box cover
Control box faces inward.
pan can be removed

Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening) Comfort High efficiency
When air conditioning two rooms Door-installed Wall-installed
Under-door cutout Switchable fan speed:High/Middle/Low and Auto DC fan motor and DC drain pump are utilised
simultaneously, the air discharged into ventilation grille ventilation grille
each room must be circulated back to (“Auto” is applicable when BRC1E62 is used.) to improve energy efficiency
the air conditioner. To achieve this, a
ventilation duct should be installed for
Clean
Ventilates air through
Partitioning wall
the partitioning wall.
each room or one of the indicated (See right)
ventilation grilles should be installed Ventilation grille Ventilation grille Under-door cutout
on the partitioning wall or under the
Note: The under-door cutout method should be used only when there is a small volume of airflow. Silver ion anti-bacterial drain pan
door between the rooms.
A built-in antibacterial treatment that uses silver ion in the drain pan prevents
the growth of slime, bacteria, and mould that cause smells and clogging.
9 10
FLOOR STANDING TYPE

New airflow control for New comfortable airflow control


more comfort 1) Left and right directions (by remote controller)
Auto swing direction is selectable from 3 patterns to suit the layout of the room.
(Applicable when BRC1E62 is used.)
Pattern 1 Swing wide across the front Pattern 2 Swing across left side Pattern 3 Swing across right side

FVQ71/100/125/140C

When installed in the center of a wall. When installed in the corner of a room.

2) Up and down directions (by hand)


Independent up-and-down airflow directions facilitate even room temperature and help save energy.

Freely select Example applications


New unit
both up and Upper louver (1)
When cooling
down airflow Upper interlocking louvers (4)
Turning louvers
BRC1E62
direction with Lower interlocking louvers (2)
and upward
Lower louver (1)
can be 8-louver and leaving
and horizontal
incorporated (horizontal Each set of louvers to will reduce
into the blade) setting. can be independently uneven room
indoor unit. adjusted. (Manual adjustment) temperature.

Comfortable fan speed Quiet operation dB(A)

control Indoor unit


Sound pressure level
71C 100C 125C 140C

Option
Switchable fan speed: High 43 50 51 53

Accessory required for indoor unit.


High/Middle/Low and Auto Middle 41 47 48 51
("Auto" is applicable when BRC1E62 is used.)
Low 38 44 46 48
Navigation Remote Controller
Auto airflow rate is selectable
(Wired Remote Controller)

BRC1E62
Airflow rate is automatically controlled in accordance with the
difference between room temperature and set temperature.
Quick and easy installation
Note: Remote controller cable is not
and maintenance
included and must be procured
locally. High fan speed mode (applicable for FVQ71/100) Lightweight indoor unit
To carry airflow to the far side of the room, airflow rate can be
increased 5% or 10% depending on the installation condition or Enables smooth transport and installation of the indoor unit.
(kg)
customer's request. (Field setting by remote controller.)
Indoor unit 71C 100C 125C 140C
Wired LCD remote controller Programme "Dry" Weight 39 47
Dehumidification is microprocessor controlled to prevent abrupt
BRC1C61 and uncomfortable changes in air temperature. Long-life filter (standard) requires no
Note: Remote controller cable is not
included and must be procured
maintenance for about 1 year*
locally. The filter is washable and reused after 1 year.

Energy saving * For dust concentration of 0.15 mg/m3


-Two time settings (2500 hrs and 1250 hrs) are available to match the installation
environment. Maintenance time warning is displayed on the remote controller (filter sign).
-The periodical cleaning time for the filter can be shortened depending on the usage
DC fan motor improves efficiency environment.

Employs a safety lock function of suction grille


The grill will not open even upon impact.

DIII-NET communication standard


Connection to a centralised control system is available
without option.
11 12
OUTDOOR UNIT
Whatever your space, give it the comfort
Outdoor unit it deserves

RQ71MV1 RQ100MV1 RQ125MY1


RQ71MY1 RQ100MY1 RQ140MY1

Easy installation and maintenance


Pre charged for up to 30 metres 4-direction piping offers Facilitates pump down
If the refrigerant piping length does not greate rlayout freedom (Refrigerant recovery function)
exceed 30 m, there is no need for on-site A pump-down switch is provided to make it
gas charging. The outer panel for the piping easier to collect refrigerant if the unit is to be
connection part of the front, right side moved or layout modified.
and backside can be removed and is
easier for post-installation piping work. *Pump-down function is available for pre-charged
Long piping length refrigerant amount.

Allowed refrigerant piping length Removable part of bottom Easy centralised installation
and level difference
frame makes the piping with the module oriented
RQ71-140M
work easier design
Pre
charged1 30 m
Depth of 71-140M are standardised as
Max. 50 m 320 mm. Horizontal continuous mounting
length (Equivalent length 70m) is available.
Max. level Suction
difference 30 m

Note : 1Additional refrigerant charging is 320 mm 71M 100M 125M 140M


required if the refrigerant pipe is Separation
longer than the length. available
Discharge

900 mm 900 mm 900 mm 900 mm

Compact and lightweight Durability


Reduced installation work thanks to
light, compact outdoor unit. As the bottom frame is subject
Reduced by to corrosion, a corrosion-proof
Comparison of outdoor units 175 mm
galvarium steel plate is
RY140LUY1 RQ140MY1
1170 Reduced by
adopted to enhance the
mm
1170 mm 11 kg
Height 1,345 mm
durability
Weight 112 kg 101 kg
RY140LUY1 RQ140MY1
Heat exchange fins are
provided with anti-corrosion
Operation range treatment
Construction
Suited for year-round Wide operation range
Non-treated fin Aluminium
cooling applications 50
Hydrophilic treatment
40
46˚C Anti corrosion
Aluminium
Cooling is efficient even in winter 30 DB treated fin Corrosion resistant
when indoor temperatures are higher resin
than those outside, such as in 20 Cooling
underground public spaces or offices 10 15˚C
with many computers. -5˚C WB
Heating
0 DB
-10˚C
-10
WB

-20
Outdoor temp(˚CDB) Outdoor temp(˚CWB)

13 14
REMOTE CONTROLLER Optional accessory

Easy-to-read LCD remote controller allows various system control configurations and can control multiple indoor units.
Remote controller options are shown on the page introducing each indoor unit model.

Navigation Remote Controller Wired LCD remote controller


Wired remote controller has
(Wired LCD Remote Controller) Easy to read because of large LCD screen.
built-in temperature-sensor
The rubber switch and the (Applies to wired remote controllers (BRC1C61/1E62))
oil-resistant plastic casing are Enables temperature sensing closer to target
This simple, modern designed remote controller with fresh white adopted for durability. area for improved comfort. (When using remote
colour matches your interior design. Operation is much easier Only 17 mm thick. Can be control from another room, temperature-sensor in
indoor unit's air inlet must be selected.)
and smoother, just follow the indications on the navigation remote installed either recessed or
exposed.
controller.
Facilitates maintenance and repair
All initial settings can be set from the remote
controller. After interior construction is complete,
BRC1E62 BRC1C61 ceiling mounted cassette type can be remotely
set without having to use stepladder access for
manual setting.
Clear Display Setting contents: High ceiling use, air direction, filter type, address
Wireless LCD remote controller for centralised control (group control address is set automatically).

Dot matrix display Backlight Remote controller is equipped with model name
A combination of fine dots display The wireless remote controller is and failure display functions. This facilitates
enables various icons. supplied in a set with a signal service in the unlikely event of a malfunction.
receiver. (Model name display function applies to BRC1E62 only.)
Large text display is easy to
see. Signal receiver unit is contained
inside decoration panel or indoor
unit. SkyAir shares common control with
Shape of signal receiver unit Heat Reclaim Ventilator and the
differs according to the indoor other Daikin air-conditioning units,
unit. thus simplifying interlocking
Energy saving BRC7F634F
operations.
NEW Setpoint auto reset NEW Setpoint range set Signal receiver unit Easily adaptable to large-scale, high-function,
Wireless remote (For ceiling mounted Note: The signal receiver unit shown in the centralised remote control systems.
controller cassette type) photograph is for mounting inside
- Even if the set temperature is changed, after a preset period new set - Saves energy by limiting the Installing and connecting control wiring between
the decoration panel of the ceiling
temperature returns to preset value. min. and max. set temperature. mounted cassette type. SkyAir and other Daikin air-conditioning
- Period selectable from 30, 60, 90, or 120 min. - Avoids excessive heating or equipment is easy.
Restaurant example cooling.
Restaurant opened Full tables at lunchtime After 30 minutes* - This function is convenient if the Wireless remote controller for each indoor unit type
Temperature is set to 27ºC Then is lowered to 24ºC for Automatically returns to preset remote controller is installed Heat pump
crowded room temperature (27ºC)
Returns to where anyone can change the CEILING MOUNTED CASSETTE TYPE BRC7F634F
27°C 24°C 27°C
automatically
settings. CEILING SUSPENDED TYPE BRC7GA53
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE BRC4C65

*Preset-return time can be set

Off timer (programmed)


at 30, 60, 90, or 120 min

- Sets and saves setting for an increment of time that automatically turns off air LCD panel shows operating status in letters, numbers, and motion.
conditioner after a preset period of time for each time operation starts.
- Period can be preset from 30 to 180 minutes in10-minute increments. Airflow / swing display Displays auto-swing operating status and setting position of air discharge angle.
Preset temperature / operation mode display Displays preset room temperature and operating status (fan, dry, cool).
Operation start and stop time can be set for individual timers up to 72 hours. The LCD also shows
Convenience Programming time display
when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning.
Self-diagnosis function Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs.
Weekly schedule Multilingual display
- 5 actions per day can be scheduled for each day Display is available in 11
of the week. languages.
- The holiday function will disable schedule timer (English, German, French, Spanish,
for the days that have been set as holiday. Italian, Portuguese, Greek, Dutch,
Russian, Turkish, and Polish).
NEW - 3 independent schedules can be set.
(e.g. summer, winter, mid-season)

15 16
REMOTE CONTROLLER Optional accessory FUNCTIONS
CEILING MOUNTED DUCT CONNECTION MIDDLE
CASSETTE TYPE CEILING SUSPENDED TYPE FLOOR STANDING TYPE

Functions
Round Flow
STATIC PRESSURE TYPE

System variation to control multiple indoor units


Control pattern Wired remote controller Wireless remote controller
overview Indoor unit FCQ71-140KAVEA FHQ71-140DAVMA FBQ71-140EVE FVQ71-140CVEB
Control by 1 (Basic system) Heat pump RQ71/100MV1 RQ71/100MV1 RQ71/100MV1
remote controller Outdoor unit RQ71-140MY1
RQ71-140MY1 RQ71-140MY1 RQ71-140MY1
Non-polar, double-core Signal receiver unit installed
(max. wiring length 500 m) on indoor unit Auto swing
Swing pattern selection
For control from 2 Draft prevention function (heating)
Control by 2 locations such as in
remote controllers room and control room, Independent up-and-down airflow
Connects 2 wired remote Not possible
exits, etc. DC fan mortor (Indoor unit)
controllers (See note 1) (See note 2, 3)
Switchable fan speed 3step 3step 3step 3step
Comfort Auto airflow rate *1
For simultaneous
High fan speed mode *5
Group control control of up to 16
indoor units. Automatic address setting function Automatic address setting function Programme “Dry”
Signal receiver unit installed High ceiling application *6
on 1 indoor unit
Two selectable temperature-sensors *2
Operation and monitoring Hot start
is carried out using the
Control by contact signal from the
(Command from outside) (Command from outside)
Year-round cooling applicable
external command operation control box in
the monitoring room. Optional wiring adaptor for Optional wiring adaptor for
electrical appendices is necessary electrical appendices is necessary Setpoint auto reset *1
Setpoint range set *1
Central remote controller (option) Remote
Central remote controller (option) Weekly schedule timer *1
Controller
Centralised control of Off timer (programmed) *1
Centralised remote up to 64 indoor groups On/Off timer *3
control from remote location
up to 1 km away.
Anti-bacterial air filter *7
Cleanliness
Silver ion anti-bacterial drain pan

Heat Reclaim Heat Reclaim


Ventilator Ventilator Drain pump mechanism *7
Link by remote Pre-charged for up to 30 m *4
controller group control.
Can be operated simultaneously Can be operated simultaneously Long-life filter *7
or independently by remote controller by remote controller Work &
(set by ventilation mode) (set by ventilation mode) Filter sign
Interlock control servicing
with Heat Reclaim Central remote controller (option) Central remote controller (option)
Ceiling soiling prevention
Ventilator Emergency operation
Self-diagnosis function
Zone link control by
centralised control. Heat Reclaim Heat Reclaim
Ventilator Ventilator
Auto-restart
Heat Reclaim Ventilator for indoor units within a zone are operated by Heat Reclaim Ventilator for indoor units within Auto-cooling/heating change-over
interlocking. Can also be operated independently by remote controller. a zone are operated by interlocking
Control by 2 remote controllers
Note:1BRC1E62 can connect to BRC1E62 only. 2It is not possible to use two wireless remote controllers. 3BRC1E62 cannot connect to wireless remote controller.
Control Group control by 1 remote controller
features External command control *7 *7 *7 *7
Central remote control
Easily adaptable to large-scale, high-function, centralised remote control system. Interlock control with Heat Reclaim Ventilator
Central remote controller Unified on/off controller Schedule timer DIII-NET communication standard
DCS302CA61 (Option) DCS301BA61 (Option) DST301BA61 (Option) DCS601C51 (Option)
High-efficiency filter
Options Ultra long-life filter
Fresh air intake kit

Others Anti corrosion treated heat exchangers *4


Centralised control, with a setting as Centralised control of on/off by Unified control of weekly schedule With its high functionality, the full
simple as it is with a standard group or all at once for up to 256 for up to 1,024 indoor units. colour “all-in-one” graphic controller
facilitates management of SkyAir
Note: *1 : Applicable when BRC1E62 is used *5 : Applicable for FVQ71-100
remote controller, of up to 64 groups indoor units. Schedule timer sets on/off time in 1 minute units
(1,024 indoor units) is possible. to be executed twice a day for a week at a time. System in a variety of ways. *2 : Applicable when wired remote controller is used *6: Installable on max. 3.5 m(71) and 4.3 m (100-140) high ceiling
*3 : Applicable when BRC1C61 is used *7: Option
*4: For outdoor units
17 18
FUNCTIONS

Abundance of functions that provide comfortable


air-conditioning in stores and offices. Work and Servicing
Note: Some features only available on selected models. See overview pages for full list of features applicable to each unit. Drain pump mechanism Filter sign
Steeper gradient realises more efficient condensate drainage. The filter sign warns you when it is time to clean the filter.

Comfort High-lift is especially useful for long lengths of drain piping. *When using a wired remote controller the sign is displayed in the LCD. When using
a wireless remote controller the filter sign lamp illuminates on the signal receiver unit.

Auto-swing Programme "Dry"


Delivers comfortable
air-conditioning to all areas, near to
The air flow direction can be
fixed at your desired angle by
Dehumidification is microprocessor controlled to prevent abrupt and
uncomfortable changes in air temperature. Useful for reducing
Ceiling soiling prevention
and far from the air-conditioner. the remote controller. uncomfortable humidity without uncomfortable cooling of the room. Daikin's innovative air discharge mechanism keeps airflow away from
the ceiling. Ceiling cleaning is less frequently required.

Swing pattern selection High-ceiling application


You can freely set air discharge settings by remote controller. Delivers air-conditioning Pre charged for up to 30 m Emergency operation
comfort all the way
(1) standard setting (2) Ceiling soiling prevention setting
If refrigerant piping length does not exceed 30 m, there is no need Even if there is a malfunction elsewhere in the system, the fan or
down to the floor in for on-site gas charging.
air-conditioning zones
compressor can still be operated. (depending on the malfunction)
with high ceilings.
Self-diagnosis function
Long-life filter The operating parameters of indoor and outdoor units, and sensor
data at critical locations throughout the system, are constantly
Draft prevention function (heating) Note:When units are installed on high ceilings, depending on the model, various Maintenance is not required for one year*. monitored using a microcomputer. To facilitate quick response in the
To prevent cold air drafts, automatically adjusts airflow to near
restrictions concerning maximum height, air discharge direction, and choice of The filter is washable and can be reused. event of a malfunction, a message appears on the LCD of the remote
options may apply.
horizontal position when heating initially starts or when the thermo off. *For dust concentration of 0.15 mg/m3 controller and an LED on the unit illuminates.

Two selectable temperature-sensors


Independent up-and-down airflow
Temperature-sensors are included in the indoor unit and optional Control features
Independently adjust (manually) the eight horizontal blade louvers in wired remote controller. Temperature sensing closer to target area is
both up and down directions to achieve an airflow that reduces
uneven room temperature.
possible to further increase the Auto-restart External command control
comfort level.
Use the temperature-sensor in the indoor unit when controlling air If there is a power outage while the equipment is operating, Operation and monitoring is carried out using the contact signal
operations will restart in the same mode as before the power cut from the operation control box in the building monitoring room.
DC fan motor (indoor unit) conditioning from another room.
when electricity is restored. *An option is required.
DC fan motor improves efficiency. Note: Wireless remote controllers have no
temperature-sensor.
Auto-cooling / heating change-over
Central remote control
Switchable fan speed Detects difference in preset temperature and actual room
temperature and automatically switches to cooling or heating Optional central remote controller enables centralised control of
High setting provides maximum reach while low setting minimises accordingly. up to 1024 indoor units (64 groups) from up to 1 km away.
drafts.

Hot start Control by 2 remote controllers


Auto airflow rate Cold air flow is avoided when heating operation starts or when Using 2 remote controllers you can operate the equipment locally or Interlock control with Heat Reclaim Ventilator
Airflow rate is automatically controlled in accordance with the switching to heat after defrosting. from a remote location. Enables interlocking control with external equipment such as Heat
difference between room temperature and set temperature. Note: When a wireless remote controller is used, remote control by two remote Reclaim Ventilator.
Year-round cooling applicable controllers is not possible.

High fan speed mode Efficient cooling even in winter when the indoor temperatures are Group control by 1 remote controller
You can increase fan speed approximately 10% higher than the higher than those outside, such as in underground public spaces or DIII-NET communication standard
"high" setting. offices with many computers. You can turn up to 16 indoor units on/off with a single remote
controller. (When using connected indoor units, the settings must all Standardly equipped interface enables connection to centralised
be the same and on/off will be simultaneous.) control system without need of an adaptor.

Remote Controller
Options
Setpoint auto reset Off timer (programmed)
Even if the set temperature is changed, after a preset period Sets and saves setting for an increment of time that automatically High-efficiency filter Fresh-air intake kit
new set temperature returns to preset value. turns off air conditioner after a preset period of time for each time
Two types are available: 65% and 90% colorimetry. You can provide air-conditioning with fresh air from outside. Convenient
operation starts.
Setpoint range set for places where a ventilation fan cannot be installed.

Saves energy by limiting the minimum and maximum set On/Off timer Ultra long-life filter
temperatures. Avoids excessive heating and cooling. Operation starts when the preset time of the ON timer elapses and
Requires no maintenance for about 4 years* (10,000h) in stores and
stops when the preset time of the OFF timer elapses.
Weekly schedule timer offices.
*For dust concentration of 0.15 mg/m3
Up to five operation ON/OFF settings can be programmed per day for
each day of the week. Not only can the time be set for the operation
ON setting, but also the temperature.

Others
Cleanliness Anti corrosion treated heat exchangers
Anti-bacterial air filter Silver ion anti-bacterial drain pan To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, Anti corrosion treated fin for heat
exchangers (with special coating) are used for the heat exchanger of the outdoor unit. In high corrosive areas, regular maintenance
The air filter has an anti-bacterial treatment to help prevent the A built-in antibacterial treatment that uses silver ion in the drain needs to be carried out.
growth of bacteria and mould on it. pan prevents the growth of slime, bacteria, and mould that cause
smells and clogging.

19 20
SPECIFICATIONS

CEILING MOUNTED CASSETTE TYPE DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
71 100 125 140 71 100 125 140
Indoor unit FCQ71KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA Indoor unit FBQ71EVE FBQ100EVE FBQ125EVE FBQ140EVE
Model Model
Name RQ71MV1 RQ100MV1 Name RQ71MV1 RQ100MV1
Outdoor unit RQ125MY1 RQ140MY1 Outdoor unit RQ125MY1 RQ140MY1
RQ71MY1 RQ100MY1 RQ71MY1 RQ100MY1
Power supply Outdoor unit V1 1 Phase, 220–230 V, 50 Hz ---------- Power supply Indoor unit 1 Phase, 220–240 V, 50 Hz
Y1 3 Phase, 380-415 V, 50 Hz Outdoor unit V1 1 Phase, 220–230 V, 50 Hz ----------
Cooling capacity1,3 kW 7.1 10.0 12.5 14.0 Y1 3 Phase, 380-415 V, 50 Hz
Rated (Min. - Max.) Cooling capacity1,3 kW 7.1 10.0 12.5 14.0
Btu/h 24,200 34,100 42,700 47,800
Heating capacity2,3 Rated (Min. - Max.) Btu/h 24,200 34,100 42,700 47,800
kW 8.0 11.2 14.0 16.0
Rated (Min. - Max.) Heating capacity2,3 kW 8.0 11.2 14.0 16.0
Btu/h 27,300 38,200 47,800 54,600
Power consumption Rated (Min. - Max.)
Cooling1 2.72 3.83 4.66 4.91 Btu/h 27,300 38,200 47,800 54,600
kW
Heating2 2.85 3.75 5.06 4.97 Power consumption Cooling 1
2.71 3.78 4.67 5.02
kW
COP Cooling 2.61 2.61 2.68 2.85 Heating2 2.49 3.91 4.52 4.91
W/W
Heating 2.81 2.99 2.77 3.22 COP Cooling 2.62 2.65 2.68 2.79
W/W
Indoor Colour Unit ---------- Heating 3.21 2.86 3.10 3.26
unit Decoration panel Fresh white Colour ----------
Indoor
Airflow rate (H/M/L) m3/min 21/17.5/13.5 32/26/20 33/28/22.5 unit Fan Airflow rate (H/M/L) m3/min 23/19.5/16 32/27/22.5 36/30.5/25
cfm 741/618/477 1,130/918/706 1,165/988/794 cfm 812/688/565 1,130/953/794 1,271/1,077/883
Sound pressure level4 (H/M/L) dB(A) 35/31.5/28 43/37.5/32 44/39/34 44/40/36 External static pressure 4
Pa Rated 50 (50-150)
Dimensions Unit mm 256X840X840 298X840X840 Sound pressure level5 (H/M/L) dB(A) 38/35/33 38/35.5/33 40/37.5/35
(HXWXD) Decoration panel mm 50X950X950 Air filter6 ----------
Machine Unit kg 21 24 Dimensions (HXWXD) mm 245X1,000X800 245X1,400X800
weight Decoration panel kg 5.5 Machine weight kg 37 47
Certified Cooling °CWB 12 to 25 Certified Cooling °CWB 12 to 25
Operation range Heating °CDB 15 to 27 Operation range Heating °CDB 15 to 27
Outdoor Colour Ivory white Outdoor Colour Ivory white
unit Coil Type Cross fin coil unit Coil Type Cross fin coil
Compressor Type Hermetically sealed scroll type Compressor Type Hermetically sealed scroll type
Motor output kW 2.2 3.0 3.75 2.9 Motor output kW 2.2 3.0 3.75 2.9
Refrigerant charge (R-410A) kg 2.7 3.7 Refrigerant charge (R-410A) kg 2.7 3.7
(Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m)
Sound pressure level4 Cooling / Heating dB(A) 50/52 53/56 54/56 Sound pressure level5 Cooling / Heating dB(A) 50/52 53/56 54/56
Dimensions (HXWXD) mm 770X900X320 1,170X900X320 Dimensions (HXWXD) mm 770X900X320 1,170X900X320
Machine weight kg 84(V1), 83(Y1) 103(V1), 101(Y1) 108 101 Machine weight kg 84(V1), 83(Y1) 103(V1), 101(Y1) 108 101
Certified Cooling °CDB -5 to 46 Certified Cooling °CDB -5 to 46
Operation range Heating °CWB -10 to 15 Operation range Heating °CWB -10 to 15
Piping Liquid (Flare) mm 9.5 Piping Liquid (Flare) mm 9.5
connections Gas (Flare) mm 15.9 connections Gas (Flare) mm 15.9
Drain Indoor unit mm VP25 (I.D 25XO.D 32) Drain Indoor unit mm VP25 (I.D 25XO.D 32)
Outdoor unit mm 26.0 (Hole) Outdoor unit mm 26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70) Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30 Max. installation level difference m 30
Heat insulation Both liquid and gas piping Heat insulation Both liquid and gas piping
Note : Note :
1
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
2
2
Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
3
3
Capacities are net, including a deduction for cooling for indoor fan motor heat. Capacities are net, including a deduction for cooling for indoor fan motor heat.
4
4
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection. External static pressure is changeable in 11 stages by remote controller.
5
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
6
Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency(gravity method) 50% or more.

CEILING SUSPENDED TYPE FLOOR STANDING TYPE


71 100 125 140 71 100 125 140

Model Indoor unit FHQ71DAVMA FHQ100DAVMA FHQ125DAVMA FHQ140DAVMA Indoor unit FVQ71CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB
Name Model
Outdoor unit RQ71MY1 RQ100MY1 RQ125MY1 RQ140MY1 Name RQ71MV1 RQ100MV1
Outdoor unit RQ125MY1 RQ140MY1
Power supply Outdoor unit 3 Phase, 380-415 V, 50 Hz
RQ71MY1 RQ100MY1
Cooling capacity1,3 kW 7.1 10.0 12.5 14.0
Rated (Min. - Max.) Power supply Outdoor unit V1 1 Phase, 220–230 V, 50 Hz ----------
Btu/h 24,200 34,100 42,700 47,800
Y1 3 Phase, 380-415 V, 50 Hz
Heating capacity2,3 kW 8.0 11.2 14.0 16.0
Cooling capacity1,3 kW 7.1 10.0 12.3 14.0
Rated (Min. - Max.) Btu/h 27,300 38,200 47,800 54,600 Rated (Min. - Max.) Btu/h 24,200 34,100 42,000 47,800
Power consumption Cooling1 kW 2.70 3.75 4.51 4.87
Heating capacity2,3 kW 8.0 11.2 14.0 16.0
Heating2 kW 2.85 4.13 5.00 4.94 Rated (Min. - Max.)
COP Cooling 2.63 2.67 2.77 2.87 Btu/h 27,300 38,200 47,800 54,600
W/W Power consumption Cooling1 kW 2.87 3.95 4.79 5.44
Heating 2.81 2.71 2.80 3.24
Colour Light ivory Heating2 kW 3.04 3.75 4.67 5.28
Indoor Cooling 2.47 2.53 2.57 2.57
Airflow rate (H/M/L) m3/min 20.5/17/14 28/24/20 31/27/23 34/29/24 COP
unit W/W
cfm 724/600/494 988/847/706 1,094/953/812 1,200/1,024/847 Heating 2.63 2.99 3.00 3.03
Sound pressure level (H/M/L)
4
dB(A) 38/36/34 42/38/34 44/41/37 46/42/38 Indoor Colour Fresh white
mm 235X1,270X690 235X1,590X690 unit Fan Airflow rate (H/M/L) m3/min 18/16/14 28/25/22 28/26/24 30/28/26
Dimensions (HXWXD)
Machine weight kg 32 38 cfm 635/565/494 988/883/777 988/918/847 1,059/988/918
Certified Cooling °CWB 12 to 25 Sound pressure level (H/M/L) 4
dB(A) 43/41/38 50/47/44 51/48/46 53/51/48
Operation range Heating °CDB 15 to 27 Dimensions (HXWXD) mm 1,850X600X270 1,850X600X350
Colour Ivory white Machine weight kg 39 47
Outdoor Certified Cooling °CWB 12 to 25
unit Coil Type Cross fin coil
Type Hermetically sealed scroll type Operation range Heating °CDB 15 to 27
Compressor
Motor output kW 2.2 3.0 3.75 2.9 Outdoor Colour Ivory white
Refrigerant charge (R-410A) 2.7 3.7 unit Coil Type Cross fin coil
kg (Charged for 30 m) (Charged for 30 m) Compressor Type Hermetically sealed scroll type
Sound pressure level4 Cooling / Heating dB(A) 50/52 53/56 54/56 Motor output kW 2.2 3.0 3.75 2.9
Dimensions (HXWXD) mm 770X900X320 1,170X900X320 Refrigerant charge (R-410A) 2.7 3.7
Machine weight kg 83 101 108 101 kg (Charged for 30 m) (Charged for 30 m)
Certified Cooling °CDB -5 to 46 Sound pressure level4 Cooling / Heating dB(A) 50/52 53/56 54/56
Operation range Heating °CWB -10 to 15 Dimensions (HXWXD) mm 770X900X320 1,170X900X320
Piping Liquid (Flare) mm 9.5 Machine weight kg 84(V1), 83(Y1) 103(V1), 101(Y1) 108 101
connections Gas (Flare) mm 15.9 Certified Cooling °CDB -5 to 46
Drain Indoor unit mm VP20 (I.D 20XO.D 26) Operation range Heating °CWB -10 to 15
Outdoor unit mm 26.0 (Hole) Piping Liquid (Flare) mm 9.5
Max. interunit piping length m 50 (Equivalent length 70) connections Gas (Flare) mm 15.9
Max. installation level difference m 30 Drain Indoor unit mm VP20 (I.D 20XO.D 26)
Heat insulation Both liquid and gas piping Outdoor unit mm 26.0 (Hole)
Note : Max. interunit piping length m 50 (Equivalent length 70)
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). Max. installation level difference m 30
2
Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) Heat insulation Both liquid and gas piping
3
Capacities are net, including a deduction for cooling for indoor fan motor heat.
4 Note :
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection. 1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
3
Capacities are net, including a deduction for cooling for indoor fan motor heat.
4
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

21 22
OPTIONS

Indoor unit Indoor unit


CEILING MOUNTED CASSETTE TYPE CEILING SUSPENDED TYPE
Kit name Kit name
Name of option Remark Name of option Remark
FCQ71KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA FHQ71DAVMA FHQ100DAVMA FHQ125DAVMA FHQ140DAVMA
Decoration panel BYCP125K-W1 Replacement long-life filter Resin net KAFP501A80 KAFP501A160
Sealing material of air discharge outlet KDBH55K160F Fresh air intake kit KDDQ50A140
Panel spacer KDBP55H160FA Drain pump kit KDU50P140VE
Fresh air Chamber Without T-duct joint KDDP55B160 (Components:KDDP55C160-1, KDDP55B160-2)2 L-type piping kit (for upward direction) KHFP5N160
intake kit1 type With T-duct joint KDDP55B160K (Components:KDDP55C160-1, KDDP55B160K2)2 Remote controller Wireless type Heat pump BRC7GA53
Direct installation type KDDP55X160A Wired type1 BRC1C61
High-efficiency filter unit (Colorimetric method 65%) KAFP556C80 KAFP556C160 Navigation Remote Controller Wired type1 BRC1E62
(including filter chamber) (Colorimetric method 90%) KAFP557C80 KAFP557C160 Central remote controller2 DCS302CA61
Replacement (Colorimetric method 65%) KAFP552B80 KAFP552B160 Unified ON/OFF controller2 DCS301BA61
high-efficiency filter (Colorimetric method 90%) KAFP553B80 KAFP553B160 Schedule timer2 DST301BA61
Filter chamber KDDFP55C160 intelligent Touch Controller2 DCS601C51
Replacement long-life filter KAFP551K160 Wiring adaptor for electrical appendices KRP1BA54
Ultra long-life filter unit (including filter chamber) KAFP55C160 Wiring adaptor for electrical appendices3 KRP4AA52
Replacement ultra long-life filter KAFP55H160H Installation box for adaptor PCB KRP1D93A
Branch duct chamber KDJP55B80 KDJP55B160 Remote sensor (for indoor temperature) KRCS01-4B
Chamber connection kit3 KKSJ55KA160 Electrical box with earth terminal (3 blocks) KJB311AA
Insulation kit for high humidity KDTP55K80 KDTP55K160 Electrical box with earth terminal (2 blocks) KJB212AA
Remote controller Wireless type Heat pump BRC7F634F Note: 1Wiring for wired remote controller to be procured locally.
Wired type4 BRC1C61 2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
Navigation Remote Controller Wired type4 BRC1E62
3
Installation box for adaptor PCB(KRP1D93A) is necessary.
Central remote controller5 DCS302CA61
Unified ON/OFF controller5 DCS301BA61
Schedule timer5 DST301BA61 DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
intelligent Touch Controller5 DCS601C51 Kit name
Adaptor for wiring6 KRP1C63 Name of option Remark
FBQ71EVE FBQ100EVE FBQ125EVE FBQ140EVE
Wiring adaptor for electrical appendices(2)6 KRP4AA53 High-efficiency filter1 65% KAFP632B80 KAFP632B160
Installation box for adaptor PCB KRP1H98A 90% KAFP633B80 KAFP633B160
Remote sensor (for indoor temperature) KRCS01-4B Filter chamber(for rear suction)1 KDDFP63B80 KDDFP63B160
Note: 1Refer to page 6 for the details. Long-life filter1 KAFP631B80 KAFP631B160
2
Please order using the names of both components instead of set name. Service panel White KTBJ25K80W KTBJ25K160W
3
Required for installing high-efficiency filter unit and ultra long-life filter unit.
4
Wiring for wired remote controller to be procured locally. Fresh white KTBJ25K80F KTBJ25K160F
5
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. Brown KTBJ25K80T KTBJ25K160T
6
Installation box for adaptor PCB (KRP1H98A) is necessary. Air discharge adaptor KDAP25A71A KDAP25A140A
Shield plate for side plate KDBD63A160
Remote controller Wireless type Heat pump BRC4C65
Wired type2 BRC1C61
Round flow type: List of optional parts required to achieve different flow patterns Navigation Remote Controller Wired type2 BRC1E62
For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option Adaptor for wiring KRP1C64
(shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect. Wiring adaptor for electrical appendices(2) KRP4AA51
A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation. Remote sensor KRCS01-4B
Mounting plate for adaptor PCB.3,4,5 KRP4A98
Central remote controller6 DCS302CA61
All round flow 4-way flow Unified ON/OFF controller6 DCS301BA61
Optional accessory parts Wireless Fresh air intake kit Fresh air intake kit Insulation kit High-efficiency Ultra-long-life Schedule timer6 DST301BA61
Panel spacer1
Independently installable optional parts remote controller (Chamber type)1,2 (Direct installation type) for high humidity filter unit2 filter unit2 intelligent Touch Controller6 DCS601C51
Panel/grille related Panel spacer1 o o o x o o Note: 1If installing high efficiency filter and long-life filter to the unit, filter chamber is required. 4
Up to 2 adaptors can be fixed for each mounting plate.
Operation control related Wireless remote controller o o o o o o 2

3
Wiring for wired remote controller to be procured locally. 5
Only one mounting plate can be installed for each indoor unit.
o o x x o o Mounting plate is necessary for each adaptor marked . The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
6
Auxillary function related Fresh air intake kit (Chamber type)1,2
Fresh air intake kit (Direct installation type) o o x o o o
Insulation kit for high humidity x o x o x x
Filter related High-efficiency filter unit2 o o o o x x
Ultra-long-life filter unit2 o o o o x x
FLOOR STANDING TYPE
3-way flow 2-way flow Name of option Remark
Kit name
Wireless Fresh air intake kit Fresh air intake kit Insulation kit High-efficiency Ultra-long-life FVQ71CVEB FVQ100CVEB FVQ125CVEB FVQ140CVEB
Optional accessory parts Panel spacer 1
Independently installable optional parts remote controller (Chamber type)1,2 (Direct installation type) for high humidity filter unit2 filter unit2 Replacement long-life filter KAFJ95L160
o3 x x o3 Remote controller Wired type1 BRC1C61
Panel/grille related Panel spacer1 o3 o3
Navigation Remote Controller Wired type1 BRC1E62
Operation control related Wireless remote controller o3 o o o x o Central remote controller2 DCS302CA61
Auxillary function related Fresh air intake kit (Chamber type)1,2 o3 o x x x o Unified ON/OFF controller2 DCS301BA61
Fresh air intake kit (Direct installation type) o3 o x o x o Schedule timer2 DST301BA61
Insulation kit for high humidity x o x o x x intelligent Touch Controller2 DCS601C51
Filter related Ultra-long-life filter unit2 o3 o o o x x Adaptor for wiring3 KRP1BA57
Wiring adaptor for electrical appendices KRP4AA52
Installation box for adaptor PCB KRP4AA95
Branch duct connection Note: 1Wiring for wired remote controller to be procured locally.
2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
Optional accessory parts Wireless Fresh air intake kit Fresh air intake kit Insulation kit High-efficiency Ultra-long-life
Panel spacer 1 3
Installation box for adaptor PCB (KRP4AA95) is necessary.
Independently installable optional parts remote controller (Chamber type)1,2 (Direct installation type) for high humidity filter unit2 filter unit2
Branch duct chamber 1 1-way branch / unit 3-way flow o o o o 4 x x o
(Round duct type) 2-way branch / unit 2-way flow x o o o 4 x x o
1
1-way branch / unit 2-way flow x o o o 4 x x o Outdoor unit
In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to check
whether or not joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable. Kit name
2
Use a chamber connection kit if two different types of optional chamber are used together. In this case, the fresh air intake kit must be installed in the upper position.
3
It is not possible to use panel spacers in a 2-way flow installation. Name of option Heat pump
4
It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed. RQ71MV1 RQ100MV1
RQ125MY1 RQ140MY1
RQ71MY1 RQ100MY1
Central drain plug KKPJ5F180

23 24
DIMENSIONS (Unit: mm)

CEILING MOUNTED CASSETTE TYPE CEILING SUSPENDED TYPE

[FCQ71-140KAVEA] [FCQ71-140KAVEA] [FCQ71KAVEA] [FCQ100-140KAVEA]


[FHQ71DAVMA]
210 Connection position of fresh air intake kit
B 156
Connection position 105 φ100(Knock out hole)
860~910(Ceiling opening space) (Note 4) 81 2x100=200 85 Connection position 81 2 100=200 85 of branch duct 18 17 20 16 120
300 102 9
or less 710(Hanging bolt pitch) 950 124 of branch duct 160 (round shape type) 131 57 90

35
Note 2 C/L (round shape type) C/L
420 8 16-M4 Hole
9 16-M4 Hole

157 63
92
175
87
30

163
189
100
67

210

115
90
160

160
Piping Connection

195
860~910(Ceiling opening space) (Note 4)
Side

167
780(Hanging bolt pitch)

93

40
63

110
95
124

bolt pitch)
(Hanging
116

29
95
157 51 60 134 59

260
Connection position 157
Connection position 12
350 of branch duct 350 10
of branch duct

950
C Position slit hole for taking out in pipe back
(square-shaped type) (square-shaped type)
B arrow view

(Required space)
B arrow view
6 (View from the front)
8
Drain Connection

(Required space)
220
Side 103
7 [FCQ71KAVEA] [FCQ100-140KAVEA] 1230 19 15
690 (Hanging bolt pitch)
160 160

5
420 A arrow view 167
Connection position 124 93 67 Hanging bolt 4 5 11

175
of branch duct 109 Connection position
of branch duct 95

5
(square-shaped type) 4-M8~M10 1
95 (square-shaped type) 29

91
131
20-M4 20-M4

197

197
[FCQ71KAVEA] [FCQ71KAVEA] Prepared hole Prepared hole Position : Hole of wall for taking out in pipe back

235
16-M4 Prepared hole

2 100=200 80
2x100=200 80
Adjustable(0~675)

55 840 55 Connection position 27-M4 Prepared hole (View from the front)
3

(Required space)
From the floor side 2500 or more
of branch duct 57

160
124
340 55 840 55 6

For height installation

300 or more
(square-shaped type) 13 14
80 2 100=200 80

25
25
81 2x100=200 85 5 57 φ45

157
350
157
350
124 64 C/L C/L
850

124
110

30 or more 1270 30 or more


95

50

124
110
105

(Service space) (Service space)


60

95

213
213
The Front 1 Air discharge grille
124

80
256

80
ø1 Obstacle Brand name plate
ø1
160
246

175

160
2 Air suction grille
150

Connection position
(kn 00
10

29

Connection position (kn 00

130
(Note.2)
42
125
165

of branch duct

90
90
of branch duct ock Floor side
35 or less (round shape type) hole (round shape type) holock 3 Air filter
20 C/L 256 35 or less ) 90 e)
90 4 Gas pipe connection

From the floor side 2500 or more


(required space)
50
40

(Note 4)

For height installation


157 (Note 4) Connection position

1500 or more
157 Connection position 183 of fresh air intake kit 196
Hanging bolt 350 Connection position Connection position of fresh air intake kit Drain piping connection VP20 5 Liquid pipe connection
4-M8~M10 4 1 2 of branch duct 350 of branch duct (direct installation type) C arrow view (direct installation type) C arrow view 6 6 Drain pipe connection
280 (For left pipe)
330 (round shape type) A (square-shaped type)
Connection position 7 Earth terminal (inside the control box) (M4)
of branch duct
(round shape type) 8 Hanger
9 Rear pipe penetration cover

268
268

221
214
10 Top panel penetration cover
11 Right side pipe connection
76 83 12 Left back drain pipe connection
[FCQ100-140KAVEA] [FCQ100-140KAVEA] 3 2 7 5 105 4 13 Left side drain pipe connection
156 14 Right side drain pipe connection
16-M4 Prepared hole 15 Hole of wall for taking out in pipe back
3 55 Notes:
Adjustable(0~675)

55 840 55 Connection position 840 55


of branch duct 2 100=200 27-M4 Prepared hole 1
Location of unit's Name Plate: Bottom of fan housing inside the suction grille. 16 Upward drain pipe connection
340 81 85 Required space 1500mm or more
(square-shaped type) 64 160 2
In case of using wireless remote controller, this position will be a signal receiver. 17 Upward gas pipe connection
80 2 100=200 80 5 200mm or more
850

18 Upward liquid pipe connection


167

160 50 1500mm Refer to the drawing of wireless remote controller in detail.


95

167
95

or more 19 Power supply wiring and a unit wiring back connection


93
105

3
1500mm Please do not place the thing been damp and troubled under an indoor unit.
60

29

or more When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. 20 Power supply wiring and a unit wiring upper connection
160
298

200mm
or more 1500mm or more
175
160
288

160
150
29
10

130
42
125
165

67

The necessary space is 500mm or more when the


20 C/L 35 or less 256 35 or less air-outlet is blocked with the accessory.
From the floor side 2500 or more
(required space)

CEILING SUSPENDED TYPE


50
40

For height installation

157 Moreover when the corner areas are blocked


1500 or more

(Note 4) 157 (Note 4)


Hanging bolt 350 Connection position Connection position (both right and left of the blocked air outlet),
4 1 2 350 the necessary space is 200mm or more.
4-M8~M10 280 of branch duct of branch duct
Connection position (round shape type) A (square-shaped type)
of branch duct 330
(round shape type) [FHQ100-140DAVMA]
210
156 Connection position of fresh air intake kit
105 120
18 17 20 16 102 φ100(Knock out hole)
9
Notes: 131 57 90

35
1
Sticking location for manufacture's label

157 63
92
manufacture's label for indoor unit:

87
30

163
189
100

90
210

175

115
195
Suction grille inner side's electric components box's lid surface 1 Liquid pipe connection
manufacture's label for decoration panel : 2 Gas pipe connection

40
Decoration panel's corner decoration cover inner surface 63

bolt pitch)
3

(Hanging
Drain pipe connection 116 51 60 134 59

260
2
In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller 12
in detail. 4 Transmission wiring connection 10
3 5 Remote controller wiring Position slit hole for taking out in pipe back
When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit

(Required space)
continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required. connection (View from the front)
4
Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less 6 Air-outlet 8
220

(Required space)
between the indoor unit and the ceiling opening so that 7 Suction grille 103
the panel overlap allowance can be ensured. 8 Corner decoration cover 1550 19 15
5
Please do not place the thing been damp and troubled under an indoor unit. 690 (Hanging bolt pitch)
9 Drain hose (accessory)

5
When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. Hanging bolt
4-M8~M10 1 4 5 11

175
5

91
131
197

197
235
Position : Hole of wall for taking out in pipe back
(View from the front)

From the floor side 2500 or more

(Required space)
57

For height installation


14

300 or more
13 6
57 30 or more 1590 30 or more
(Service (Service φ45
space) space)
The Front
1 Air discharge grille
Obstacle Brand name plate
2 Air suction grille
Floor side (Note.2)
3 Air filter
4 Gas pipe connection
Drain piping connection VP20 5 Liquid pipe connection
(For left pipe) 6 6 Drain pipe connection
7 Earth terminal (inside the control box) (M4)
8 Hanger
9 Rear pipe penetration cover

268

268
221
214
10 Top panel penetration cover
11 Right side pipe connection
76 83 12 Left back drain pipe connection
3 2 7 5 105 4
13 Left side drain pipe connection
156 14 Right side drain pipe connection
Notes: 15 Hole of wall for taking out in pipe back
1
Location of unit's Name Plate: Bottom of fan housing inside the suction grille. 16 Upward drain pipe connection
2
In case of using wireless remote controller, this position will be a signal receiver. 17 Upward gas pipe connection
Refer to the drawing of wireless remote controller in detail. 18 Upward liquid pipe connection
3
Please do not place the thing been damp and troubled under an indoor unit. 19 Power supply wiring and a unit wiring back connection
When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. 20 Power supply wiring and a unit wiring upper connection

25 26
DIMENSIONS (Unit: mm)

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE FLOOR STANDING TYPE

[FBQ71EVE] [FVQ71-140CVEB] 260


Inspection hatch 2 4- 14 Hole 130 215 This model to be fixed with fixture
30-φ4.7hole 134 630 10 450 or more CASE1) Control box (For bolt) 126 as shown below.
(All around) (Hanging bolt position) Inspection hatch 1 Suction grille
( Drain

300 or more
pan removal stopper
and part exchange. )
(450x450)

M
Inspection hatch 3 In case of fixing it at the bottom
7

200 or less
8 ※When can work enters (SAME AS THE INDOOR
UNIT SIZE +300 OR MORE) In case vibration resistance is

P
the space under the unit,
required, fix it at both the bottom

N
inspection hatch 2 is Control box

130
unnecessary. and the rear.
Control box
0.7
9 Inspection hatch Fig.A
Ceiling

1300 or more
11x65=715
1038(Hanging bolt position)

CASE 2),3) Detail View

1000 or more
Control box
50
835

Inspection hatch1 (Two both sides) or

30
(450x450) 600 68 D 330 mo

18
or less
20 or more
Air Air inlet re 50

200
outlet Control box
Pull out or

13x65=845
800 or more 800 or more mo

1000
36-φ4.7hole Inspection hatch 2 re

500
Inspection hatch View B-1 View B-2 direction

500

(All around) (SAME AS THE INDOOR
Ceiling UNIT SIZE OR MORE)
Unit base of air-filter
Fixture

314
Air inlet (Accessory) 2-7X15 re
mo
Air outlet
oblong hole
0 or
(For wood screw) 50

(Pull out dimension of air-filter)


Suspention 1
200 or less

Inspection hatch 2※ Required space


450 16-8x12 oblonghole (4pieces) bolt Fig. A-1
(450X450)
53
(Service space)

65
69

(All around)
450 or more

740 or more
13
176
100
194

677
Notes:
Drain pan 5x156=780 26 1 Suction grille
138

maintenance space 1
Locations of Manufacturer's Label:Surface of a control box
792 8 2 Air filter
Control Box
2
Make sure to mount the air filter inside the air passage on
Inspection hatch 1 815
maintenance space the suction side. (Select Duct Collection Efficiency 1 3 Through hole for side piping

1850
450 or more 800 or more
View <Gravimetric Method>50% or more.) 9
(Service space) (70x90 oblong slit hole)
(From the Air outlet) 3
If the temperature and humidity in the ceiling is likely to Approx.46
12 exceed 30℃ and RH80%, strengthen heat insulation by 4 Through hole for side piping
10 Full open
3x50=150

( 80 slit hole)
(643 or less)

1 2 6 5 3
300 or less 499 applying the additional insulation materials such as glass
2x50=100

position of
207 Adjustable

wool or polyethylene that has thickness of 10mm or more. suction grille 3 5 Through hole for side piping
850 or less

4
Do not put things that should not get wet under the indoor unit. G 6 ( 27 slit hole)
Dews may drop when humidity reaches over 80%, a drain E

825
5 6 6 Through hole for rear
245

gets stuck or air filters are not clean. F

222
Air Air inlet
6
183

208
136

226
123

(Note.2)
outlet 5
Space for Service Works piping/wiring

616
541
6x150=900
4 (80x130 oblong slit hole)
60

91 Provide service spaces for service work such as check and

95
38

4 7

50
952
300 or more

(A case without

179 50 maintenance of the control box and drain pump by one of the 7 Through hole for bottom
2500 or more

11

50
(Note.5)

977 following ways.


the ceiling)

300
piping/wiring

100
100
18-8x12 oblong hole (From the Air inlet) 1)Inspection hatch 1and 2(450x450) (Fig.A-1) and a space of

95
Drain pan maintenance 800
check hole (All around) 300mm or more under the unit. (Fig.A) A H
(126x130 square hole)
200 184 184
Note:Inspection hatch 2 is not needed when there is a space for B 8 Liquid pipe connection

75
Ceiling Floor surface 223 J

34
service work under the unit. C 9 Gas pipe connection
253 K
2)Inspection hatch 1(450x450) on the control box side, and
1 Liquid pipe connection 6 Remote control wiring connection 11 Socket(For maintenance) Inspection hatch 2 under the unit. (View B-1) 598 L 10 Drain pipe connection
2 Gas pipe connection 7 Power supply wiring connection 12 Drain hose(Accessory) 3)Inspection hatch 3 under the unit and control box. (View B-2)
3 Drain pipe connection 8 Air discharge flange 13 Drain hose connection(Accessory) A B C D E F G H J K L M N P
Provide enough space for maintenance and mount the drain
4 Earth terminal(terminal in Control box) 9 Air suction flange pan and control box. Notes: FVQ71CVEB 50 110 186 270 45 50 50 110 180 186 242 57 144 149
5 Control box(Inside) 10 Hanger Check the drawing of optional accessories when mounting 1
Sticking location for manufacturer’s label: on the surface of
optional accessories such as filter chamber and humidifier.
cover of switch box inside the suction grille. FVQ100/125/140CVEB 130 190 266 350 44 49 130 190 260 266 322 79 202 229

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

[FBQ100-140EVE]
44-φ4.7hole 134 630 10
(All around) (Hanging bolt position) 50-φ4.7hole
(All around) CASE1) Control box
8
9 Inspection hatch 1
(450x450) Inspection hatch 3
300 or more
200 or less

Inspection hatch 2
450 or more (SAME AS THE INDOOR
UNIT SIZE +300 OR MORE)
( Drain
and part exchange. )
pan removal Control box
Inspection hatch
1438(Hanging bolt position)

Control box Fig.A Ceiling


1700 or more
18x65=1170

※When can work enters


the space under the unit, CASE 2),3) Control box
20x65=1300

1400 or more
1235

inspection hatch 2 is Inspection hatch1


200 or less

unnecessary.
1400

(450x450)
20 or more

Control box
Air inlet 800 or more 800 or more
Air B Inspection hatch 2
Inspection hatch View B-2
500

outlet View B-1


Ceiling (SAME AS THE INDOOR
UNIT SIZE OR MORE)
Air inlet
500

Air outlet
Unit base

650 20-8x12 oblonghole bolt Inspection hatch 2※


Suspention
(All around) (4pieces) (450X450)
200 or less

Fig. A-1
(Service space)
450 or more

53
65
69

176
100
194

13 Notes:
Control Box 26
1
Locations of Manufacturer's Label:Surface of a control box
maintenance space 7x156=1092 2
Make sure to mount the air filter inside the air passage on
138

Drain pan 1192


maintenance space the suction side. (Select Duct Collection Efficiency
1215 <Gravimetric Method>50% or more.)
Inspection hatch 1
450 or more 800 or more View 3
If the temperature and humidity in the ceiling is likely to
(Service space) (From the Air outlet) exceed 30℃ and RH80%, strengthen heat insulation by
12 applying the additional insulation materials such as glass
3x50=150

300 or less
(643 or less)

699 wool or polyethylene that has thickness of 10mm or more.


2x50=100

2
207 Adjustable

1 6 5
850 or less

3 4
Do not put things that should not get wet under the indoor unit.
Dews may drop when humidity reaches over 80%, a drain
gets stuck or air filters are not clean.
226
208
245

Air inlet
60

222

Space for Service Works


183

Air 5
(Note.2)
136

123

outlet
91 Provide service spaces for service work such as check and
26-8x12 oblong hole
38

300 or more

4 7
(A case without

maintenance of the control box and drain pump by one of the


2500 or more

100 100 6x150=900 100 100


50
(Note.5)

11 179 (All around) following ways.


the ceiling)

300 1352
Drain pan maintenance 800 1377 1)Inspection hatch 1and 2(450x450) (Fig.A-1) and a space of
check hole (From the Air inlet) 300mm or more under the unit. (Fig.A)
Ceiling Floor surface Note:Inspection hatch 2 is not needed when there is a space for
service work under the unit.
2)Inspection hatch 1(450x450) on the control box side, and
1 Liquid pipe connection 6 Remote control wiring connection 11 Socket(For maintenance)
Inspection hatch 2 under the unit. (View B-1)
2 Gas pipe connection 7 Power supply wiring connection 12 Drain hose(Accessory) 3)Inspection hatch 3 under the unit and control box. (View B-2)
3 Drain pipe connection 8 Air discharge flange 13 Drain hose connection(Accessory)
Provide enough space for maintenance and mount the drain
4 Earth terminal(terminal in Control box) 9 Air suction flange pan and control box.
5 Control box(Inside) 10 Hanger Check the drawing of optional accessories when mounting
optional accessories such as filter chamber and humidifier.

27 28
DIMENSIONS (Unit: mm)

OUTDOOR UNIT // RQ71MV1/MY1 OUTDOOR UNIT // RQ125/140MY1

Hole for anchor bolt


4-M12
Hole for anchor bolt

30
4-M12

30

(345~355)

320
350

56
38
(345~355)

320
350

36

30
38
89

56
140 620 140
30 900
36
3

30
89
140 620 140 3 4
30 900 4 2
2
1 1
7 7 7
7
6

1170
6 6 7 6
5 5 5
6 5
770

55
55

423
422

55
60
341
339

223
223
60

54 95

53 95
84 55

95

95

95
54 95

89

84
54
24

54
89 19 19 80
89
24

52

53
89 19 19 80 52
142 145
13 67
71 16 142 145 13 67
8
58 16

8 71 16
70 102 117

1 Gas pipe connection 1 Gas pipe connection

16
2 Liquid pipe connection 2 Liquid pipe connection

70 102 117
3 Service port 3 Service port

58
4 Grounding terminal
5 5 Refrigerant piping intake
4 Grounding terminal
5 Refrigerant piping intake
45 376 191 6 Power supply wiring intake 5 6 Power supply wiring intake
7 Control wiring intake 7 Control wiring intake
8 Drain pipe connection 8 Drain pipe connection
45 376 191

OUTDOOR UNIT // RQ100MV1/MY1

Hole for anchor bolt


4-M12
30
(345~355)
350

320
38
56

36
30

89
140 620 140
30 900
3
4
2
1
7
7
1170

6
7 6
5
6 5
5
55
423
422
60

55

223
95

95
95
89

84
54
24

54

53

19 80 52
89 19
142 145 13 67

8 71 16
58 16

1 Gas pipe connection


70 102 117

2 Liquid pipe connection


3 Service port
4 Grounding terminal
5 5 Refrigerant piping intake
6 Power supply wiring intake
45 376 191 7 Control wiring intake
8 Drain pipe connection

29 30
DIMENSIONS (Unit: mm) Installation service space for outdoor unit

REMOTE CONTROLLER
For RQ71/100MV1, RQ71-140MY1 (Unit: mm)
The values in ( ) are for RQ71 type.

1 When there is an obstruction on the inlet side 2 When there is an obstruction on the outlet side
Wireless type
1) When the overhead space is open 1) When the overhead space is open
• Remote controller dimensions CEILING MOUNTED CASSETTE TYPE <Round Flow>
Transmitting part • Receiver installation procedure 1. For single unit installation 1. For single
When there is an obstruction only unit installation
Receiver
Refrigerant
piping side
on the inlet side
re
mo
0 or
157

50

0) 2. For series installation (more than two units)


0(5 re
10 r mo
o
When there are obstructions on
Drain piping
side both sides
62 17.5

•Remote controller holder Decoration panel


installation procedure
• Receiver detail
<installation to wall surface>
10 ore
0o rm
Liquid crystal rm 0 0o
remote controller ore 10
10 0
(wireless) 0o
rm 10 ore
Remote controller
ore or
m
2) When there is an obstruction in the overhead space
holder

2. For series installation (more than two units) 1. For single unit installation
s
les
When there are obstructions on both sides An obstruction
0 or
in the overhead 50

1000 or more
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE CEILING SUSPENDED TYPE
space
• Receiver detail • Receiver installation procedure
2-5x9 Slot

The Front Receiver


10
00
or
(Ceiling opening)

mo
re
83.5
120

106
72

) ore
20 00 rm
0o 0(2 re 0o
rm
ore 30 r mo 50
o
0.5
70 18 35 49
(Ceiling opening)
2. For series installation (more than two units)
Switch box
• Receiver detail ss
(field Supplied parts) r le
0o
50
2) When there is an obstruction in the overhead space

1000 or more
Service space for ceiling installation
Note :
(Srevice space)
More than 90

Do not install more than 3 receivers in


the vicinity of one another.
With 4 or more units, there is always 1. For single unit installation
the possibility of malfunction

When there is an obstruction on the inlet side


ss
Wired type r le

1000 or more
• Remote controller dimensions 0o
50
BRC1C61 • Installation method
An obstruction An obstruction re
A Exposed body, exposed cord B Exposed body, embedded cord C Exposed body, embedded code
in the overhead in the overhead mo
Conduit
or
17
Staple
space 0
space 00
Remote Remote
controller controller 1
Remote
42

controller
120

84

0
10 ore
117

3 When there are obstructions on both


38

m
0~5 or

the inlet and outlet sides


(Between remote
When there are obstructions on the inlet side and
17 Through hole
controller and
120 17 18 control box)
( 12- 16)
Cord
outlet 17
Control box both lateral sides An obstruction (When the obstruction on the outlet side is higher than the
23 28
hole in the overhead s
unit itself)

1000 or more
Specifications of cord r les
space 0o
46 Note) 50
Type Shield wire (insulated thickness: 1 mm or more) 1. Remote controller cord and staple are not
Size 0.75~1.25 mm 2 attached.
They are field supplied parts.
1) When the overhead space is open
Total length 500 m (There is no limit to the height of the obstruction on the
outlet side.)
BRC1E62 • Installation method
Upper case Lower case or 150
A Exposed cord
Staple
B Embedded cord C Embedded cord
(use switch box)
Condit mo
re 0
1. For single unit
or 150 15 ore
Top left 19 19
outlet
Top center
outlet mo
or
m installation
re

H
42

Operation
   
lamp

L
120

84

(Green)
2. For series installation (more than two units)
40

0)
84
84

0(5 re
40

Code outlet hole When there are obstructions on the inlet side and 10 r mo
0 o
120 19 28 5X15 oblong hole 48.5 Note)2 28 46 both lateral sides L H 50 ore
m
5X7 oblong hole 23 48.5 Through hole
( 8- 10) Switch box for one switch
0~5
Switch box for two switch (Between remote or
Left outlet
46 19 Lower case portion ex.) KJB111A ex.) KJB211A controller and
(optional accessory) (optional accessory)
2. For series installation (more than two units)
control box)
Lower case portion Switch box An obstruction
[field supplied part]
in the overhead
ss

1000 or more
Note) le
space or
1. Remote controller cord and staple are not attached. They are field 2.If the hole size is too large or the location 0
50
supplied parts. is not proper, the hole may come out from
Specifications of cord the remote controller.

Type Vinyl cord with sheath or cable (insulated thickness: 1mm or more)

H
1
Size 0.75~1.25 mm2 or 000
mo
Total length 500 m re
)
00
) 0(2 re
00 30 r mo
or 200 0(2 re o
30 r mo 00
mo o 10 ore
re L H or
m

Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book.
31 32
MEMO

33 34