December 2019
Contents
Appendix A – Drawings
1.1 The objective of this report is to present the drainage design concept for the
proposed development.
2.1 The total land cover by the proposed site is 46.6 acre (18.9 ha).
2.2 The site is generally flat, undeveloped land, with existing ground level
completed by previous earthworks to a platform level of 55.00 O.D.L.
Vegetation is non-existent at the time of writing of this report.
2.3 The access to the proposed site is via existing roads within the Techpark 2
development.
2.4 The Key Plan and Location Plan are as shown in Figure 1 and Figure 2.
3.1 In the existing condition, the site is drained by temporary earth drains which
discharge to the existing sediment basin and subsequently to the existing
roadside drains.
3.2 The permanent drainage system of the proposed development will discharge
directly to the existing external roadside drains, and subsequently to an
existing Kolam Takungan Awam (KTA) centralized retention pond adjacent to
the Techpark 2 development, which caters for the catchment area of our site.
3.3 Please refer to Appendix C for the Catchment Layout Plan and flow direction
plan to the main drains and KTA.
3.4 To provide additional redundancy for the KTA, our drainage system proposal
includes additional OSD capacity.
3.5 The permanent drainage system of the proposed development will flow
through primary and secondary outlets at each discharge point to provide
OSD capacity to control the rate of discharge to the existing external roadside
drains.
Reference is made to Manual Saliran Mesra Alam Malaysia 2012, (MSMA 2nd.
Edition), Urban Stormwater Management Manual for Malaysia published by
Department of Irrigation and Drainage Malaysia.
The following main criteria are adopted in the design of Internal Drainage:
5.1 The minimum and maximum average flow velocity for open drain is 0.8 m/s
and 4.0 m/s respectively for lined channel drain.
5.2 The discharge for internal drain is designed for minor system based on
average recurrence interval (ARI) of 10 years and the major system is
checked to a 100-year ARI.
5.3 The total catchment shall be sub divided into sub catchments. Please refer to
the respective appendices for catchment layout plan and internal drainage
hydraulic design calculations.
5.4 Appendix A shows the proposed drainage system alignment on the Road and
Drainage Layout drawing. Appendix C shows the Catchment Layout Plan.
6.0 ON SITE DETENTION (OSD)
Reference is made to Manual Saliran Mesra Alam Malaysia, (MSMA 1st Edition),
Urban Stormwater Management Manual for wMalaysia published by Department of
Irrigation and Drainage Malaysia.
The following criteria are adopted in the design of the OSD systems.
6.1 The primary and secondary outlets are designed for an average recurrence
interval (ARI) of 10 years and 100-year ARI respectively.
6.2 Each catchment area shall be diverted to their respective OSD systems.
6.3 Appendix A shows the proposed drainage system alignment, including the
location of OSD systems, on the Road and Drainage Layout drawing.
6.5 Catchment areas for each catchment are shown graphically in Appendix C on
the Catchment Layout Plan.
OSD Site Storage Volume calculation for each catchment is calculated in the
OSD design calculations in Appendix D.