Beruflich Dokumente
Kultur Dokumente
DOCUMENT NO DATE
PROJECT: Design, Construction, Testing, Commissioning and Operation and Maintenance of Infrastructure Works for Roads, Drains, Culverts, Bridges, Water Supply, Sewerage, Street Lighting and Utility Duct in the Smart City area in Rajkot
LNT-RSC-FS-DWG-7001 26.12.19
Invert depth (As Per Hydraulic Design LNT-RSC-FS-DC-2001 Hydraulic Design of Sewer
m = 2 3 4 5 6 7 8 9
Sheet of Sewer Network) Network
Internal diameter of pipe mm = 900 900 900 900 900 900 900 900
Barrel wall thickness IS 458:2003, Table 3 Pg 8 mm = 100 100 100 100 100 100 100 100
External diameter of pipe (Bc) = DN + 2*Barrel thickness DN + 2*Barrel thickness DN + 2*Barrel thickness DN + 2*Barrel thickness DN + 2*Barrel thickness DN + 2*Barrel thickness DN + 2*Barrel thickness DN + 2*Barrel thickness
mm = 1100 1100 1100 1100 1100 1100 1100 1100
IL - Inner dia of pipe -Barrel IL - Inner dia of pipe -Barrel IL - Inner dia of pipe -Barrel IL - Inner dia of pipe -Barrel IL - Inner dia of pipe -Barrel IL - Inner dia of pipe -Barrel IL - Inner dia of pipe -Barrel IL - Inner dia of pipe -Barrel
Height of crown below Ground Level (H) =
Wall Thickness Wall Thickness Wall Thickness Wall Thickness Wall Thickness Wall Thickness Wall Thickness Wall Thickness
m = 1 2 3 4 5 6 7 8
Wheel load (P) Class AA load as per CPHEEO Manual & IRC 6 KN = 62.5 62.5 62.5 62.5 62.5 62.5 62.5 62.5
Three edge bearing strength of pipe (Ul) CPHEEO Manual Appendix A 3.9 Pg A - 74 KN/m = 99.44 99.44 99.44 99.44 99.44 99.44 99.44 99.44
Factor of Safety ( fs ) = 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5
CPHEEO Section 3.50.3.3 Chapter 3 Pg - 83 = (W * fs) / Ul (W * fs) / Ul (W * fs) / Ul (W * fs) / Ul (W * fs) / Ul (W * fs) / Ul (W * fs) / Ul (W * fs) / Ul
Bedding factor
= 1.13 1.12 1.31 1.51 1.67 1.82 1.93 2.03
Type of Bedding required = B B B B B B Aa Aa