CB-142
INSTALLATION
AND
OWNER’S MANUAL
MB-070102-1E- CB
KS-090404
INTRODUCTION
This manual explains correct installation, operation, maintenance and inspection of the sys-
tem with cautionary remarks. Please read this manual carefully before installing the com-
ponents and starting operation to ensure correct usage of the system.
Keep this manual on board in a safe and dry place. If you transfer or resell the system, be
sure to hand this manual to the new owner.
The illustrations and/or contents of this manual may slightly differ from the actual product
due to changes in specification, etc.
z Remote steering control is performed electrically by the Portable Controller PT-10C and
the Helm Controller DTX-10 (DTX-10D) which are connected to the Control Amplifier
CB-142.
z Total of three remote controllers can be used.
INSTRUCTION SYSBOLS
WARNING: Involves hazards or unsafe practices which could result in severe per-
sonal injury or death.
CAUTION: Involves hazards or unsafe practices which could result in minor injury
or product/property damage.
2
SAFETY PRECAUTIONS
WARNING
Thunder/Lightning
● When thunder/lightning occurs, do not touch metal parts or the power switch as there is a
danger of getting an electric shock by inductive lightning.
Operation
z Misoperation and/or malfunction of the system due to the damage to its components may
cause an accident. Severe damages to human life and the environment as well as dam-
ages to the vessel may result.
z Complete understanding of the characteristics of the system, of its capability and limitations
are required. Become familiarized with operations and pay utmost attention when using the
system.
Emergency Operation
z Familiarize yourself with the emergency operation and be able to perform it smoothly should
something happen.
z If malfunction of the system should occur, slow down the vessel and set the operation mode
to MANUAL to steer the vessel with the manual helm pump.
Maintenance Service
z In the course of maintenance, pay extra attention not to touch the moving steering gear
when getting in the steering gear room.
z Use proper fuses when replacing them. Use of improper fuses may cause damage to the
device and cause a fire.
Installation
● Use the correct DC voltage. Do not use alternate currents or non-specified DC power
sources. Using a wrong power source may cause fires, electric shocks and/or damage to
the system components.
● Do not strain or scratch the cables. Damaged cables may cause fires or electric shocks.
● Components such as, Control Amplifier and Solenoid Valve Unit, are not watertight. Do not
let the components get wet; fires or electric shocks may result. Should the component get
wet, turn off the power switch and inspect it promptly.
3
CAUTION
Operation
z Do not hit the Portable Controller against the wall or floor as it may break.
z Do not start the engine after switching on the DC power to the system. It may cause a mal-
function due to a sharp DC voltage drop.
Installation
● Do not install components at locations:
・ wet by rain or sea water splash
・ hard to service for inspection and maintenance
・ under direct sunlight and/or high heat
・ near severe vibration
● Install the Solenoid Valve Unit so that the solenoid valve is aligned to a horizontal plane.
● Turn off the power switch during wiring work.
● Confirm the terminal marks and mark tubes of cables when making connections.
● Fix the screws and connectors securely.
● Adjusting the volumes of the circuit board may be required while the DC power is on. Be
careful not to short circuit.
● To avoid radio interference, install the Control Amplifier apart from any radio communication
device.
Hydraulic oil
● Check oil level of the power unit and fill oil as necessary. Use specified hydraulic oil (ISO
VG22). NEVER USE BRAKE OIL!!
High temperature
● Power Unit, piping and Helm Pump become hot during operation. Do not touch them care-
lessly.
4
TABLE OF CONTENTS
INTRODUCTION ……………………………………………………………………………………………. 2
FEATURES OF THE SYSTEM ………………………………………………………………………………… 2
INSTRUCTION SYMBOLS …………………………………………………………………………………… 2
SAFETY PRECAUTIONS …………………………………………………………………………………….. 3
5
1. SYSTEM LAYOUT
1) Addition to MSSA type (Engine Drive or AC Motor Drive) power steering system
Power
Electric Helm Helm Pump
DTX-10 HO -**
Control Amplifier
CB-142
Belt Drive
Power Unit
Feedback Unit FT-10-2 PU-**
Control Amplifier
CB-142 DC Motor
Controller
CB-25Ⅱ
Solenoid Valve Unit
SPF-1SV-LV
DC Motor Pump
Feedback Unit FT-10-2 HRP-04B
6
2. INSTALLATION
☞ NOTE
For the dimensional drawings of the system components, please refer to Appendix.
CAUTION
Do not install the components at locations:
● wet by rain and sea water splash
● hard to service for inspection and maintenance
● under direct sunlight and/or high heat
● near severe vibration
☞ NOTE
Do not forget to install the cushion rubber.
Cushion rubber
CAUTION
Do not install the Control Amplifier to a
place where maneuverability is hindered.
7
2) Electric Helms DTX-10, DTX-10D and Portable Controller PT-10C
Tow types of controllers are provided; the Electric Helms and the Portable Controller PT-10C.
The Electric Helm comes in two mounting types; the foot-mount type DTX-10 and the dash
-mount type DTX-10D. Refer to the attached dimensional drawings.
CAUTION
Do not install to a place where;
● maneuverability is hindered
● wet by rain and sea water splash
● under high heat and near severe vibration
DTX-10: Foot Mount, Cord length: 3m DTX-10D: Dash Mount, Cord length: 3m
CAUTION
Though PT-10C has watertight construction,
do not keep it in the area where frequent
temperature changes are expected. Insu-
lation of electronic parts may be damaged.
CAUTION
Install the unit so that the solenoid valve
is aligned to the horizontal plane.
Horizontal plane
8
4) Feedback Unit FT-10-2
CAUTION
Apply watertight grease to the ball
joint of the tie-rod.
CAUTION
After correctly installed, tighten the
lock nuts of the tie rod.
9
5) DC Motor Pump HRP-04A
φ6mm
10
3. HYDRAULIC PIPING DIAGRAM
1) Addition to MSSA type (Engine Drive or AC Motor Drive power steering system)
☞ NOTE
For AC Motor Drive Power Unit, the Solenoid Valve Unit will be provided on the power unit.
Power
Helm Pump
HO -**
B T
B P
11
2) Addition to MSSB type (DC Motor Pump Drive power steering system)
T port
B port
A port
Manual
Helm Pump T
H-6**
B
B A
P
P
B T
T port P port
CAUTION
DR port
12
4. ELECTRIC WIRING
1) Precaution
① Keep the following matters when pro-
ceeding to the wiring.
● Turn off the power.
● Confirm ㊉ ㊀ terminals.
G 1F 2F 3F SOLbSOLa
● When making wiring connection,
confirm the markings of the cables
and the terminals of CB-142.
● Fix the cables tightly to the terminals.
CAUTION
● Adjusting the volumes of the circuit
board may be required while the
DC power is on. Be careful not to
short circuit.
13
2) Addition to MSSA type (Engine Drive or AC Motor Drive power steering system)
☞ NOTE
When only one Controller is used, connect it to the REMOTE 1 terminal.
Control Amplifier
CB-142
Circuit Protector
(Shipyard)
Breaker
Switch
SW-NFB-1
VCT-1.25-2-5M
14
3) Addition to MSSB type (DC Motor Pump Drive power steering system)
☞ NOTE
When only one Controller is used, connect it to the REMOTE 1 terminal.
(Shipyard)
Breaker
Circuit Protector Switch
SW-NFB-1
VCTF-3.5-2-5M
Control Amplifier
CB-142
DC Motor Controller
CB-25Ⅱ
DC Motor Pump
HRP-04B
VCT-1.25-3-5M
15
5. ADJUSTMENT
1) Control Amplifier CB-142
The rear panel of the CB-142 is shown below. Adjustments are made by six volumes shown
in the figure and their functions are listed below.
CAUTION
● The adjustment is made while the power switch is on. Pay attention not to short circuit.
● A circuit protector is built-in the rear panel. When CB-142 cannot be turned on, the
circuit protector may be tripped off. The button of the circuit protector is protruded
about 1mm in this case. Check the cause. When reset, turn off the power switch and
press the button.
16
2) DC Motor Controller CB-25-Ⅱ
The selection of Flow Control function and Over Current Protection is made by the DIP
switch setting shown in the table below.
The volume VR1 adjusts the oil flow rate and the volume VR2 adjusts the value of over cur-
rent amperage.
1 2 3 4
VR2
OFF
VR1
SW1
Mー M+ T+ Tー + + ー ー
DIP Switches
No. Function Factory Setting
1 Use flow control function (VR1) ON
2 Do not use flow control function (VR1) OFF
3 Use over current function (VR2) OFF
4 Motor start signal (T㊉ one wire) ON
CAUTION
● Do not set both switches 1 & 2 at the same ON or OFF positions. When No.1 is set ON,
No. 2 should be set OFF. When No. 1 is set OFF, No. 2 should be set ON.
● The DIP switch 4 must be kept at ON position when used with Marol control amplifier.
Volumes
100% at the clockwise end. It is set at 100%
VR1 Flow Control of DC Motor Pump
when shipped from the factory.
Turn clockwise to make setting large.
VR2 Over current amperage setting It is set at the maximum value of 100A when
shipped from the factory.
CAUTION
The adjustment is made while the power switch is on. Pay attention not to short circuit.
17
3) Flow Control of Solenoid Valve Unit SPF-1SV
Adjustment of cylinder speed may become
necessary. Adjust the oil flow rate with the
flow adjust screw of the Solenoid Valve Unit
SPF-1SV (LV). Loosen the lock nut and turn Lock Nut
the adjust screw clockwise to decrease oil
flow and turn the adjust screw counter- Flow Adjust Screw
clockwise to increase oil flow. After ad-
justment, tighten the lock nut.
Refer to the attached drawing for flow rate.
☞ NOTE
The flow adjust screw is set at the maximum flow rate when shipped from the factory.
If the cylinder speed (rudder movement) is too fast, reduce the flow rate.
6. OPERATION
CAUTION
Confirm the function of the system before each sailing.
1) Manual Operation
① Turn on the power switch.
② Set the selector switch of CB-142 to MANUAL position.
③ Operate the manual helm pimp or the emergency helm pump.
2) Electric Operation and Control Method
① Turn on the power switch.
② Confirm that all the controllers are set at neutral positions.
③ Set the selector switch of CB-142 to REMOTE position.
④ Operate either the Portable Controller PT-10C or Helm Controller DTX-10.
CAUTION
When finishing the operation, set all the controllers at their neutral positions.
18
7. PERIODICAL INSPECTION AND MAINTENANCE OF THE SYSTEM
Brush Terminal
☞ NOTE
● Required to replace the brush
when it wears out to 12mm.
12 mm ● Two brushes are used, one for each
side.
19
8. TROUBLESHOOTING
20
6) Rudder does not move occasionally.
① DC Motor Pump is not working right.
→ Check the brush and replace it if required.
② Battery voltage is low.
→ Charge the battery
③ Solenoid Valve is not working properly.
→ Check the sticking of its spool. Clean the valve. If it does not cure, need repair
or replacement.
7) Rudder makes chattering while PT-10C or DTX-10(D) is steered at certain position.
① Air purging of hydraulic system is not enough.
→ Purge the system.
② Battery voltage is low.
→ Charge the battery
③ Control Amplifier is not working properly.
→ Requires repair or replacement.
④ Loose cylinder installation or loose mechanical linkage of the cylinder to the tiller
and/or Feedback Unit to the tiller.
→ Check the installation and fix it.
⑤ Loose parts inside of Feedback Unit.
→ Disassemble the unit and check the parts. Fit the parts if loose. May require re-
placement of the parts.
⑥ Loose linkage of Feedback Unit.
→ Check the linkage and fix it.
8) Rudder moving speed is too slow.
① Battery voltage is low.
→ Charge the battery
② The brush of DC Motor Pump is worn out.
→ Check the brush and replace it. (Refer to page 19)
③ The DC Motor Controller CB-25-Ⅱis not working right.
→ May require repair or replacement.
④ Hydraulic system is not properly installed or maintained. Piping size is too small, filter is
plugged, oil viscosity is too high, or V belt of power unit is loose, etc.
→ Check the hydraulic steering system.
21
218 14 80 30
186
CONTROL AMPLIFIER
MODEL CB-142 VR000:舵角左端調整 左回し→小、右回し→大
SPEC DC12V/DC24V VR001:舵角右端調整 左回し→小、右回し→大
Control Amplifier
MFG.No ******* VR000 VR001 VR002 VR003 VR004 VR005 VR002:表示中立調整 左回し→右、右回し→左
CB−142 VR003:表示右端調整 左回し→大、右回し→小
MAROL CO.,LTD MADE IN JAPAN
VR004:表示左端調整 左回し→大、右回し→小
40 30 20 10 0 10 20 30 40
REMOTE1 REMOTE2 REMOTE3 VR005:感度調整 左回し→鋭、右回し→鈍
遠隔管制器1 遠隔管制器2 遠隔管制器3 サーキットプロテクタ
:トリップ状態
61 61 61 :通常状態
5 7 2 5 7 2 5 7 2
120
4 3 4 3 4 3
切 手動 遠隔 中立 明るさ
MANUAL TRIM BRIGHTNESS
OFF REMOTE
0 FT SOL PW
4 4 追従発信器 電磁弁 電源
G 1F 2F 3F SOLb SOLa COM T+ T−
8 8
71
120
40 40
4−φ5
仕 様
電源電圧 DC10.8V∼DC30V
50
30
消費電流(電磁弁OFF時) 0.2A
消費電流(電磁弁ON時) 2.7A(DC12V)
1.5A(DC24V)
使用温度 0℃∼50℃
ケース塗装色 DIC555
質量 2.5kg
品名 制御増幅器
NAME CONTROLLER / AMPLIFIER
型式
MODEL CB−142
整理番号
No. MGE−100001
製品図番
Drawing No. SM049004−100
色
COLOR DIC555
尺度 質量
SCALE MASS 2.5kg
Note : Contents are subject to change without notice. All rights reserved by MAROL CO., LTD. 注意:データの内容は予告なしに変更になる場合があります。 データの所有権は、マロール株式会社が全て保有しています。
30
20 L
φ10
40
10
T 0 STBD
63
POR
10
40
20 30
50 60
配線図 1
120 68 CONNECTION 2
3 1 6
シールド/Shield
黒/B 白/W
1 4 2 7 5
青黄/SY 赤/R 3 4
2 5
青赤/SR 黒/B
3 6
I矢視
7 VIEW I
B=Black, R=Red, W=White, S=Blue, Y=Yellow
66.5
40
8
品名 ポータブル発信器
NAME PORTABLE CONTROLLER
型式
MODEL PT−10C
製品図番 整理番号
DRAWING No. D01−973102 D01−973109−21D01−973109−25D01−973109−26 No. MGE−411000
L寸法
12m 3m 20m 25m m
製品図番 別表参照
LENGTH L Drawing No. SEE TABLE
質量 色
MASS 1kg 0.53kg 1.4kg 1.7kg kg COLOR 黒/BLACK
備考 標準 オプション 尺度 質量
NOTE STANDARD OPTION SCALE MASS
Note : Contents are subject to change without notice. All rights reserved by MAROL CO., LTD. 注意:データの内容は予告なしに変更になる場合があります。 データの所有権は、マロール株式会社が全て保有しています。
L寸法
配線図 LENGTH L 3m m
CONNECTION 質量
3 黒/B MASS 3.5kg kg
1
2 白/W 備考 標準 オプション
40 30 20 10 0 10 20 30 40
2
M10×1.5 NOTE STANDARD OPTION
1 黒/B
LP 3 1 6
PORT
3 黄/Y
4 2 7 5
φ114
2 緑/G
120
140
5 3 4
1 赤/R
6
A矢視
STBD
7 VIEW A
B=Black, R=Red, W=White, Y=Yellow, G=Green 1/12 TAPER 操作角度
OPERATION ANGLE ±325゚
4−φ9
10 50 10
45
70
L
φ180
121
A
64
12
品名 ヘルム発信器
NAME HELM CONTROLLER
型式
MODEL DTX−10
整理番号
No. MGE−430000
製品図番
42.5 10 50 10 Drawing No. D01−97215
83.5 色
COLOR 黒/BLACK
151.5 尺度 質量
SCALE MASS
Note : Contents are subject to change without notice. All rights reserved by MAROL CO., LTD. 注意:データの内容は予告なしに変更になる場合があります。 データの所有権は、マロール株式会社が全て保有しています。
L寸法
配線図 LENGTH L 3m m
CONNECTION 質量
3 黒/B MASS 4kg kg
1
2 白/W 備考 標準 オプション
40 30 20 10 0 10 20 30 40
2
M10×1.5 NOTE STANDARD OPTION
1 黒/B
LP 3 1 6
PORT
3 黄/Y
4 2 7 5
φ114
2 緑/G 操作角度
φ80
5 3 4
OPERATION ANGLE ±325゚
1 赤/R
6
A矢視
STBD
7 VIEW A
4−φ9 95
B=Black, R=Red, W=White, Y=Yellow, G=Green 1/12 TAPER
1
φ8
95
45
4−φ9
パネルカット寸法図
PANEL CUT DIMENSION
L
φ180
115
95
品名 ヘルム発信器
NAME HELM CONTROLLER
型式
MODEL DTX−10D
整理番号
95 10 No. MGE−430002
製品図番
115 42.5 83 28 Drawing No. D01−97219−51
125.5 (63) 色
COLOR 黒/BLACK
尺度 質量
SCALE MASS
Note : Contents are subject to change without notice. All rights reserved by MAROL CO., LTD. 注意:データの内容は予告なしに変更になる場合があります。 データの所有権は、マロール株式会社が全て保有しています。
A C D
4
M8 M8
42
55
3
F
97
2F
13
1F
32
L
80 4−φ9
100
Note : Contents are subject to change without notice. All rights reserved by MAROL CO., LTD. 注意:データの内容は予告なしに変更になる場合があります。 データの所有権は、マロール株式会社が全て保有しています。
SOLb
SOLa
L1寸法(参考)
COM
使用シリンダ型式 LENGTH L1
CYLINDER MODEL
(APPROXIMATE)
MRB−50A 7.5mm
MRB−63* 8.5mm
MRB−75* 9.5mm
MRB−80* 10mm SOLa
L2
MRB−100* 11mm
MSB−*35 8.5mm A PORT
MS−*42 9mm T PORT Rc3/8
Rc3/8
MS−*42L 9.5mm
MS−*55L 10.5mm
MS−*33V 10mm
13
減少
流量調整ネジ
35
13
MS−*40V 10.5mm
A P B
増加
5334
210
80
MS−*46V 11mm
B A
MS−*55V 11.5mm
35
13
MS−*66V 12mm
P
C
MS−*70V 13mm
MS−*80V 15mm
P PORT
MS−*33W/TW 11.5mm Rc3/8 B PORT
4−φ7.5
MS−*40W/TW 12mm Rc3/8
MS−*46W/TW 13mm 3
MS−*55W/TW 13.5mm 34.5
24 SOLb 12
MS−*66W/TW 14.5mm 54.5
MS−*70W/TW 15mm 66.5 34.5
90 62
14 A B
〔L/min〕
12 110 167
SOLa SOLb
10
8
6 P L1 増加 減少
FLOW
4 INCREASE DECREASE
流量/
2 T
0
5 10 15 油圧記号 流量調整ネジ
L1〔mm〕 SYMBOL FLOW ADJUST SCREW
品名 電磁弁ユニット
型式 NAME SOLENOID VALVE UNIT
MODEL SPF−1SV−12 SPF−1SV 型式 SPF−1SV−12
製品図番
10 MODEL SPF−1SV
DRAWING No. M01−7416221 M01−74162 C部詳細 整理番号
L2寸法 備考 DETAIL C No. MGH−300000
最大流量
MAX. FLOW 20L/min LENGTH L2 NOTE 製品図番 別表参照
流量調整範囲 標準 Drawing No. SEE TABLE
0∼14L/min 8m STANDARD
FLOW ADJUSTABLE RANGE 色
COLOR 黒/BLACK
使用圧力 2 12m
WORKING PRESSURE 7.8MPa{80kgf/cm } オプション 尺度 質量
16m OPTION SCALE MASS 5kg
電源電圧
VOLTAGE DC12V DC24V
Note : Contents are subject to change without notice. All rights reserved by MAROL CO., LTD. 注意:データの内容は予告なしに変更になる場合があります。 データの所有権は、マロール株式会社が全て保有しています。
SOLb
SOLa
L1寸法(参考)
COM
使用シリンダ型式 LENGTH L1
CYLINDER MODEL
(APPROXIMATE)
MRB−50A 7.5mm
MRB−63* 8.5mm
MRB−75* 9.5mm
MRB−80* 10mm SOLa
L2
MRB−100* 11mm
MSB−*35 8.5mm A PORT
MS−*42 9mm T PORT Rc3/8
Rc3/8
MS−*42L 9.5mm
MS−*55L 10.5mm
MS−*33V 10mm 13
減少
流量調整ネジ
35
13
MS−*40V 10.5mm
A P B
増加
5334
210
80
MS−*46V 11mm
B A
MS−*55V 11.5mm
35
13
MS−*66V 12mm
P
C
MS−*70V 13mm
MS−*80V 15mm
MS−*33W/TW 11.5mm B PORT
4−φ7.5
MS−*40W/TW 12mm Rc3/8
MS−*46W/TW 13mm 3
MS−*55W/TW 13.5mm 34.5
24 SOLb 12
MS−*66W/TW 14.5mm 54.5 P PORT
MS−*70W/TW 15mm Rc3/8 66.5 34.5
90 62
14
〔L/min〕
A B
12 110 207
10
8
6 L1 増加 減少
FLOW
4
SOLa SOLb INCREASE DECREASE
流量/
2
0 P 流量調整ネジ
5 10 15
L1〔mm〕 FLOW ADJUST SCREW
T
品名 電磁弁ユニット
型式 NAME SOLENOID VALVE UNIT
MODEL SPF−1SV−LV−12 SPF−1SV−LV 油圧記号 型式 SPF−1SV−LV−12
製品図番 SYMBOL
10 MODEL SPF−1SV−LV
DRAWING No. M01−74167 C部詳細 整理番号
L2寸法 備考 DETAIL C No. MGH−300100
最大流量
MAX. FLOW 20L/min LENGTH L2 NOTE 製品図番 別表参照
流量調整範囲 標準 Drawing No. SEE TABLE
0∼14L/min 8m STANDARD
FLOW ADJUSTABLE RANGE 色
COLOR 黒/BLACK
使用圧力 2 12m
WORKING PRESSURE 7.8MPa{80kgf/cm } オプション 尺度 質量
電源電圧
16m OPTION SCALE MASS 7.6kg
VOLTAGE DC12V DC24V
Note : Contents are subject to change without notice. All rights reserved by MAROL CO., LTD. 注意:データの内容は予告なしに変更になる場合があります。 データの所有権は、マロール株式会社が全て保有しています。
リリーフ弁設定圧力 2
RELIEF VALVE SET PRESSURE7.8MPa{80kgf/cm }
吐出量(7.8MPa時)
Rc3/8(PT3/8)
DELIVERY FLOW at 7.8MPa 2.4L/min
Dr
電源電圧
VOLTAGE DC24V
最大消費電流
max. CURRENT INTENSITY 30A
タンク容量
1.5L
45.5
TANK CAPACITY
T
T
180
110
196
HRP−04A
2
PRESSURE
圧力/ 〔 kgf/cm
〕
NO.
eering and Control Systems
MAROL
MODEL
0 10 20 30 40 50 60 70 80
15.5
P
P
吐出量/ 〔 〕
.marol.co.jp
吐出量 30
/
L/min
4 FLOW(
D C28V)
〔 〕A
3 20
ENT 吐出量/
CURRENT
URR F LOW (
/C
FLOW
DC2 4V
電流 )
2
電流/
10
1 8−φ12 40 30 90 30 20
210 196
0 0
0 1 2 3 4 5 6 7 406
圧力/
PRESSURE
〔 MPa
〕
2−φ10,φ12
Rc1/4(PT1/4) 給油口栓
FILLER CAP
Rc3/8(PT3/8)
(201)
品名 DCポンプユニット
NAME DC PUMP UNIT
105
型式
MODEL HRP−04B
整理番号
4.5
No. MGE−210004
製品図番
Drawing No. M01−78148
色
COLOR
圧力計(オプション)接続口 Rc1/4(PT1/4) 尺度 質量
PRESSURE GAGE (OPTION) PORT SCALE MASS 18kg
Note : Contents are subject to change without notice. All rights reserved by MAROL CO., LTD. 注意:データの内容は予告なしに変更になる場合があります。 データの所有権は、マロール株式会社が全て保有しています。
30
過電流ランプ
210
170
2−φ6
(23)
170 10
190
40 40
品名 DCモータ制御盤
NAME DC MOTOR CONTROLLER
(61.5)
型式
MODEL CB−25−2
57
整理番号
MGE−102000
26
No.
1
製品図番
Drawing No. M01−97413
色
COLOR 10B 6.5/2
尺度 質量
SCALE MASS 1.5kg
Note : Contents are subject to change without notice. All rights reserved by MAROL CO., LTD. 注意:データの内容は予告なしに変更になる場合があります。 データの所有権は、マロール株式会社が全て保有しています。
MAROL CO., LTD.
2-1-34 Ohashi-cho, Nagata-ku, Kobe, JAPAN 653-0037
Phone: 078-611-2151
Facsimile: 078-641-2908
URL: http://www.marol.co.jp