Sie sind auf Seite 1von 10

BULK STORAGE FACILITY

Safety Equipment Data Sheet

CQS-EPR-TS-GEN-DTS-001

27-06-16 3.0 Issued for Approval C.M.O A.E.O O.A.F

20-05-16 2.0 Issued for Review C.M.O A.E.O O.A.F

18-04-16 1.0 Issued for Interdiscipline Check C.M.O A.E.O O.A.F

Date Rev Description Prepared by Reviewed by PM


Approval
Bulk Storage Facility CQS-EPR-TS-GEN-DTS-001
Safety Equipment Data Sheet Rev 3.0

TABLE OF CONTENTS

1.0 INTRODUCTION .................................................................................................. 3


2.0 SCOPE ................................................................................................................. 3
3.0 ABBREVIATIONS ................................................................................................ 4
4.0 REGULATION AND REFERENCE DOCUMENTS ............................................... 5
4.1 Codes and Standards: .......................................................................................... 5
4.2 Reference Documents: ......................................................................................... 5
5.0 EXTINGUISHERS PLACEMENT .......................................................................... 6
6.0 FIRE FIGHTING EQUIPMENT DATA ................................................................... 7
6.1 50kg CO2 Wheel Fire Extinguisher .................................................................... 7
6.2 10kg CO2 Portable Dry Chemical Extinguisher .................................................... 7
6.3 Mobile Foam Monitors Type ................................................................................ 7
6.4 Fixed Water/Foam Monitors ................................................................................. 8
6.5 Fire Hydrant .......................................................................................................... 8
6.6 Foam Proportioning Bag Tank .............................................................................. 8
6.7 Hose Rack/Box ..................................................................................................... 9
6.8 CCTV Detector ..................................................................................................... 9
6.9 Combination emergency shower and eyewash .................................................. 10

Page 2 of 10
Bulk Storage Facility CQS-EPR-TS-GEN-DTS-001
Safety Equipment Data Sheet Rev 3.0

1.0 INTRODUCTION
Eko Petrochem and Refining Company Limited wishes to construct and commission 20
new PMS storage tanks on a green field maximizing its capacity utilization.

In view of this, Crystaquantum Solutions has been awarded the contract to carry out
the Detailed Engineering Design and the requisite design to meet industry and
regulatory requirements.

The facility is intended to hold storage of one white product, Premium Motor Spirit
(PMS). The tank farm has a combined storage capacity of 453,640 cubic metres of
PMS.

1.1 SCOPE
The firefighting equipment data sheet is to specify the numbers and types of firefighting
equipments required on BULK STORAGE FACILITY PROJECT.

The under listed safety equipments shall be addressed in this datasheet.

 10kg CO2 Portable Dry Chemical Extinguisher.


 50kg CO2 Mobile Fire Extinguisher
 Mobile Foam Monitor
 Fixed foam/water monitor
 Fire Hydrant
 Hose reel/Boxes
 Ambulance
 First Aid Kit
 CCTV Detector
 Combination Emergency Shower and Eyewash
 Foam Bladder Tank

Page 3 of 10
Bulk Storage Facility CQS-EPR-TS-GEN-DTS-001
Safety Equipment Data Sheet Rev 3.0

2.0 ABBREVIATIONS
 AR-AFFF Alcohol Resistant Aqueous Film Forming Foam
 API American Petroleum Institute
 NFPA National Fire Protection Association
 ABS American Bureau of Shipping
 BV Bureau VERITAS
 CCTV Closed Circuit Television
 BS/EN British Standard/European Norm

Page 4 of 10
Bulk Storage Facility CQS-EPR-TS-GEN-DTS-001
Safety Equipment Data Sheet Rev 3.0

3.0 REGULATION AND REFERENCE DOCUMENTS


3.1 Codes and Standards:
This report shall conform to the latest issue of the following relevant codes and
standards:

 BS/EN 3-7 Portable Fire Extinguisher Characteristics, Performance,


Requirements and Test Methods.

 BS/EN 1866 Mobile Fire Extinguishers.

3.2 Reference Documents:


 Safety Design Specification

 Escape Route/Firefighting Equipment layout

Page 5 of 10
Bulk Storage Facility CQS-EPR-TS-GEN-DTS-001
Safety Equipment Data Sheet Rev 3.0

4.0 EXTINGUISHERS PLACEMENT


Generally, portable fire extinguishers shall be placed as near as possible to exits or
stairways. Advantage of normal routes of escape should be taken by placing
extinguishers in positions where they shall readily be seen by persons following the
natural impulse to get out of danger.

Page 6 of 10
Bulk Storage Facility CQS-EPR-TS-GEN-DTS-001
Safety Equipment Data Sheet Rev 3.0

5.0 FIRE FIGHTING EQUIPMENT DATA


5.1 50kg CO2 Wheel Fire Extinguisher

50kg CO 2 Wheel Fire Extinguisher


Quantit y 10
Tag Number -
Installat ion Outdoor/Indoor
Type W heeled Mobile
Extinguisher Carbon Dioxide
Manuf acturer Model Note1

5.2 10kg CO2 Portable Dry Chemical Extinguisher

10kg CO 2 Portable Dry Chemical Extinguisher


Quantit y 43
Tag Number -
Installat ion Outdoor/Indoor
Type Portable
Extinguisher Carbon Dioxide
Manuf acturer Model Note1

5.3 Mobile Foam Monitors Type


Mobile Foam Monit ors Type
Quantit y 6
Tag Number -
Installat ion Outdoor
Solid Beam Axles Maintenance - Free
Auto Reverse Braking
Yes
System
Full Road Lighting Yes
Suit able f or all Foam
Yes
Concentrates
 TM-1 light trailer without drum support
 MM-L body 3” ASA 150lbs flange, manual
action by lever
 FBP-S 15 nozzle rated 1500l/min at 7 bar,
self suction
General applicat ion
 Cover of the roof at a 25m radius throw
 Cover of gantry at 55m direct shot radius
throw.

Page 7 of 10
Bulk Storage Facility CQS-EPR-TS-GEN-DTS-001
Safety Equipment Data Sheet Rev 3.0

5.4 Fixed Water/Foam Monitors

Fixed Water/Foam Monitors


Quantit y 4
Tag Number -
Installat ion Outdoor
Positioning Fixed
Suit able f or all Foam
Yes
Concentrates
 MM-L body 3” ASA 150 lbs flange, manual
action lever
 FBP-S 15 nozzles rated 2000 l/min at 7 bar,
self suction
 1 tank of 1000L of foam agent rated 3% to
General applicat ion
be dispatched at monitor location
 Cover of the roof at a 25m radius throw
 Cover of gantry at 55m direct shot radius
throw.

5.5 Fire Hydrant

Fire Hydrant
Quantit y 20
Tag Number -
Installat ion Outdoor
Spacing Distance 60m
couplings 2 valves for couplings
Coupling type 2xBS 336 couplings, 2’’1/2
Fabricated schedule 40 body
General applicat ion Zinc primary coating
Epoxy finish coating

5.6 Foam Proportioning Bag Tank

Foam Proportioning Bag Tank


Quantit y 1
Tag Number ABJ-0601
Installat ion Outdoor
Positioning Fixed
Ver y low Fire W ater Consumption
A carbon steel body with 12 bar
General Applicat ion
maximum oper ation pressure
A CE approval f or pressure equipment

Page 8 of 10
Bulk Storage Facility CQS-EPR-TS-GEN-DTS-001
Safety Equipment Data Sheet Rev 3.0

ASA 150 Ibs f langes

2 x 4. 5000L bladder tank


To be connected together with one
Type 6”mixer
9000L of AR-AFFF new generat ion
f oam agent rated 3%
Tank Capacit y 9m 3

5.7 Hose Rack/Box

Hose Rack/Box
Quantit y 9
Tag Number HB
Installat ion Outdoor
 30 m long
General applicat ion  65 mm diameter
 All European approvals for fire brigades
 BS 336 couplings in light alloy

5.8 CCTV Detector


CCTV Detector
Quantit y 8
Tag Number CCTV
Installat ion Outdoor/Indoor
Corrodible Component 316L Stainless Steel
Pictur e High resolut ion colour zoom camera
At ever y enter ing gate, an exit gate
Locat ions/ Placement control rooms and Sensitive areas
around the f acilit y.
Telemetr y receiver(Auto f ocus)
OCN IPTC MK1 EX. Explosion proof
Transmitter type
camera only if it is located in the
hazardous area.
Measurement Range 60meters
W eight Note1
4 seconds Pan speed of 6 0 /sec and t ilt
Response Time
speed of 3 0 /sec
Output High resolut ion colour
Accuracy (% of calibrated Pan 360 0 , tilt±90 0
span)
Pan 360 0 , tilt±90 0 adjustable limit
Calibration mode switches f urther secured by mechanical
back up limitat ion
Power Supply 24vdc
Case Mater ial Note1

Page 9 of 10
Bulk Storage Facility CQS-EPR-TS-GEN-DTS-001
Safety Equipment Data Sheet Rev 3.0

5.9 Combination emergency shower and eyewash

Combination Emergency Show er and Eyew ash


Tag Number -
Quantit y 1
Installat ion Outdoor/Indoor
 Eye W ash And Emer gency Bath
 Shower with Hand release
 Eye washer with f oot release
General applicat ion  Color Green
 Fully CE approved and with all
European agreements
 UL listed
Note1: Vendor to Advise

Page 10 of 10