Beruflich Dokumente
Kultur Dokumente
Y - PVC insulation
Cables for electronics
ø
Technical data Construction
Temperature range: 1. Conductor: bare copper conductor, fine wired stranded,
• during installation and application with class 5 acc. to IEC 60228 / HD 383 / DIN VDE 0295 (at some
bending: -5 °C up to +70 °C producers certain cross-sections with 7-wire conductors)
• fixed installed: -30 °C up to +70 °C 2. Insulation: PVC compound of type TI2, acc. to DIN VDE
0281 part 1
Nominal voltage: 250 V (cable not applied for supply
purposes) • conductors stranded in layers
Insulation resistance: min. 100 MΩ x km • core colour marking defined acc. to DIN 47100, but
without repeating of colours (see page 354 of catalogue)
Inductance: approx. 0,7 mH/km
3. Separator: transparent plastic foil
Impedance: approx. 85 Ω
4. Electrostatic screen: braid of tinned copper wires with
Mutual capacitance: (at 800 Hz) max
approx. 85% overlap
• core - core: 120 nF/km
5. Sheath: PVC-compound TM2 acc. to DIN VDE 0281 part 1
• core - screen: 160 nF/km
• sheath colour: light grey (RAL 7001), grey (RAL 7032) or
blue (RAL 5015)
Conductor cross-section 0,14 mm2 ≥ 0,25 mm2
Operating voltage, max. (V) 300 500
Test voltage, max. (V) 1200 1500
Application
Flexible cable with protective screen against electromagnetic impacts, for transmission of analogue and digital signals, suitable for
fixed and mobile installations in device production, for electronic, computer and measurement systems, in mobile and production
conveyers, for office devices. Usage with shifting is only possible if not exposed to stress and mechanical loads.
Laid in dry and damp premises, but outdoor application is not recommended, except in special cases under protection against direct
sunlight. Not for direct laying in ground or water, not intended for supply purposes. Oil resistant.
190
191
conductor cross-section
nominal approx. approx.
N x mm2 mm kg/km kg/km
50 x 0,25 16 203 324 CUT
52 x 0,25 16,2 233 330 CUT
56 x 0,25 16,6 237 343 CUT
61 x 0,25 20 287,2 365 CUT
192
*) Packing: c.100 = coil 100 m d.500 = drum 500 m CUT = cable in different lengths on drum or reel, possible cutting at required length
193