Sie sind auf Seite 1von 5

Saudi Arabian Saipem Ltd.

REPORT Page 1 of 1

SAIPEM

Electrical Supervisor Top Drive Team


Full Name: Herney Perdomo Badge Number: SAS 26039
Date: 18-08-2016 Location: DAMMAM BASE
Description: Additional communication system on Canrig Top Drive

CHARACTERISTIC OF TOP DRIVE:

Top Drive Canrig 1250AC-681 with Converteam Drive

DESCRIPTION OF SITUATION:

For the high vibration on the first section of drilling, the canrig top drive has some
problems.

• Frame to blower support has been broken.

• Auxiliary lower J-BOX on the torque guide has been fallen.

Name: Herney Perdomo


Date:
18-08-2016
Position: Electrical Supervisor Top Drive Team
Saudi Arabian Saipem Ltd.

REPORT Page 1 of 1

Electrical Supervisor Top Drive Team


Full Name: Herney Perdomo Badge Number: SAS 26039
Date: 18-08-2016 Location: DAMMAM BASE
Description: Additional communication system on Canrig Top Drive

• Cover for auxiliary J-BOX on the top drive has been fallen.

• Ethernet module in J-BOX top drive has been broken in special the fiber optic
connection.

To the last situation mentioned we had been down time.

Canrig company recommends the following:

• When the top drive is subject to high vibration, we need to do the inspections
recommended by CANRIG to reduce or prevent the problems on TOP DRIVE.
(attached the document)

1. Bulletin # 21

2. Bulletin # 28

3. Bulletin # 41

4. Inspection # 1

Name: Herney Perdomo


Date:
18-08-2016
Position: Electrical Supervisor Top Drive Team
Saudi Arabian Saipem Ltd.

REPORT Page 1 of 1
SAIPEM
Electrical Supervisor Top Drive Team
Full Name: Herney Perdomo Badge Number: SAS 26039
Date: 18-08-2016 Location: DAMMAM BASE
Description: Additional communication system on Canrig Top Drive

• Electrical top drive team has a proposal for the follow point:

Ethernet module in J-BOX top drive has been broken in special the fiber optic connection.

• When the top drive is drilling in hard condition (high vibration) a thing that has
problem is Ethernet module because it broken the fiber optic connection or the
Ethernet plug.

Ethernet connection

Fiber optic connection

• Normally the top drive working with fiber optic communication until the J-BOX TD after, it
use a short Ethernet cable directly to plc, according to following drawing:

Ethernet
cables to Fiber optic connection
plc

Ethernet module

Ethernet plug

Name: Herney Perdomo


Date:
18-08-2016
Position: Electrical Supervisor Top Drive Team
Saudi Arabian Saipem Ltd.

REPORT Page 1 of 1
SAIPEM
Electrical Supervisor Top Drive Team
Full Name: Herney Perdomo Badge Number: SAS 26039
Date: 18-08-2016 Location: DAMMAM BASE
Description: Additional communication system on Canrig Top Drive

The idea is put an additional communication system but it just use Ethernet cables from
the upper J-BOX to directly PLC, in conclusion, changed the fiber optic to Ethernet cable
in this case we will need.

Two parallel communication system.

Upper J-BOX
Additional Ethernet module and
Ethernet cables in service loop

Ethernet

Fiber optic

Fiber optic
Lower J-BOX

Ethernet cables

Note: attached you can find the Drawing for the additional communication system.

• Fiber Optic
• Additional communication Ethernet cables.

Name: Herney Perdomo


Date:
18-08-2016
Position: Electrical Supervisor Top Drive Team
Saudi Arabian Saipem Ltd.

REPORT Page 1 of 1
SAIPEM
Electrical Supervisor Top Drive Team
Full Name: Herney Perdomo Badge Number: SAS 26039
Date: 18-08-2016 Location: DAMMAM BASE
Description: Additional communication system on Canrig Top Drive

The purpose is, install the additional system in a Canrig top drive and start to test about
the additional system, after we will install in all Canrig top drive.

We will need the following material:

Item Description Part Quantity


number
1 ETAP, DLR, COPPER PORT, 2 FIBER PORTS N10880 1

2 CABLE, PATCH, ETHERNET CAT 7 100 FT


3 BACKPAN,TD,PLC,W/FIBER OPTIC RECPT/E-TAP AY19226 1
4 J-BOX 40x40x25 CM 1
5 GLAND ¼ IN 4
6 GLAND ½ IN 2
7 ETHERNET E14597 2

• We will need the top drive in Dammam base for make a modification.

Remarks

• Very important when the top drive is drilling on high vibration condition, you need to do a
Canrig recommendation inspection(mandatory)

• When the additional communication system has been installed, the proposal is reduce the
Down time from lost communication on the top drive, in case you could connect the
Ethernet communication and continue working.

Name: Herney Perdomo


Date:
18-08-2016
Position: Electrical Supervisor Top Drive Team