Version: 60 Hz
Description
The BF/CBF units are extraction fans manufactured from ABS plastic. These fans, can be
connected either through the light switch, so that they start when the light is turned on, or to a
separate switch. The CBF has a spring-loaded back draft damper.
There are three models: standard model (S), a model with timer (T) and a model with timer and
humidity sensor (TH). A time delay of between 1 and 20 minutes can be set on the timer after
removing the unit’s front cover. The humidity sensor can be set to a value between 40 and 95%
relative humidity. The BF fan has an adjustment knob that is easily accessible at the bottom of
the fan. To adjust the humidity sensor on the CBF fan, the front cover should be removed first.
Technical parameters
Voltage 230 V
Frequency 60 Hz
Phase 1 ~
Current 0,18 A
Weight 1 kg
Insulation class B
Accessories
Accessories
BDS150 Back draught shutter (5929)
BVK 150 Wall vent kit (5967)
Document type: Product card | Document date: 2018-07-20 | Generated by: Online catalogue
Performance
Diagrams
0,15
0,12
Pstat [in.wg]
0,09
0,06
0,03
0
0 25 50 75 100 125
Q [cfm]
30,5
30
P [W]
29,5
29
28,5
0 25 50 75 100 125
Q [cfm]
Max efficiency
Hydraulic data
Power 29,1 W
Current 0,182 A
Voltage 230 V
Inlet dB(A) 13 49 51 53 52 47 39 29 58
Outlet dB(A) 38 58 59 57 46 46 38 28 63
Document type: Product card | Document date: 2018-07-20 | Generated by: Online catalogue
Dimensions
□A øB C
203 150 81 [mm]
Document type: Product card | Document date: 2018-07-20 | Generated by: Online catalogue