Sie sind auf Seite 1von 8

Water Technology System Co.

,
Technical/Commercial Proposal
Customer: MAC CARPET
Capacity: WWRP 60 m3/Day
Location: 1st Industrial Zone, 10th RAMADAN City
1. INTRODUCTION AND DESIGN BASIS
WATER TECHNOLOGY SYSTEM Co., Considered one of the most important companies which
works in water treatment/wastewater field, where is specialized in creation, maintenance, and
operation of Reverse Osmosis Units for seawater and brackish well water desalination and supply of
all its spare parts addition to Industrial/Domestic wastewater
WATER TECHNOLOGY SYSTEM Co., works within continuous innovative management methods,
is marked by monitoring of operation and maintenances of all company projects in all parts of the
Republic, follows-up implementation of operating plans constantly, and providing the means of
communication to be enabled to contact directly with customer to overcome sudden problems as
well as reporting of daily log sheets.

WATER TECHNOLOGY SYSTEM Co., is continually striving to improve our products and services,
and would appreciate any feedback on these Offer.
The following Offer lays out the general Specification and characterization the Industrial Wastewater
Reuse Plant 60 m3/day, consists of a compact wastewater treatment plant, based on physical-
chemical treatment. The plant is working in one stream.
The design and calculations of the Waste Water Treatment Compact Equipment Plant (dimensions
of the settlement tank, the dosing system, etc.), are conceived so that it will have the following
characteristics:

 Ease for transporting.


 Automatic functioning.
 Low demand for highly skilled workers.
 Compact design.
 Minimum demand for construction work.
 Minimum used area.
 Fast and easy start up.
 High performance.
 Constant survey and control of the plant operation.
 Safe working conditions for the staff.

Nevertheless, it is subjected to modifications, since water analyses could being processed for
better accuracy of these values.

Special attention has been paid to the quality of the produced water which can be reused again.
2. DESIGN BASIS
The design for the Industrial Wastewater Reuse Unit is in line with the feed Stream characteristics
indicated in the table below, providing 60 m3 based on 24 hr. operation. For the Present project,
Three (3) identical units will be provided.

2.1. Feed Wastewater Characteristics


Raw Water Flow rate, m3/Hr. 2.5
Feed Water Temperature, oc 25 - 35
TSD, ppm 2000
COD, mg/l as O2 4000
BOD, mg/l as O2 2000
TSS, mg/l 3000

Target of Wwtp&Reuse Unit is obtaining an effluent which parameters are according with the
“general conditions and technical specifications manual”

2.2. Treated Wastewater Characteristics

Product Water Flow rate, m3/Hr. 2


Feed Water Temperature, oc 25 - 30
pH 6:8
COD, mg/l as O2 <1100
BOD, mg/l as O2 <600
TSS, mg/l <800

3. PLANT COMPONENTS:
 Coagulation/Flocculation System.
 Lamella Settler Basin.
 De-watering Sludge Unit.
Technical Details of Wastewater Treatment Plant
1. Coagulation/Flocculation System.
Coagulation and Flocculation are employed to separate suspended solids/Dissolved Organic
Matters/Dyes/Color and Inks, which caused increasing in COD Value, from Wastewater.
Coagulation/Flocculation Process depending on Many Factors such as Coagulant Type, Mixers and
Retention time.
Coagulation is the destabilization of colloidal particles brought about by the addition of a chemical
reagent called as coagulant.
Flocculation is the agglomeration of destabilized particles into microfloc and after into bulky floccules
which can be settled called flocs. The addition of another reagent called flocculants or a flocculants
aid may promote the formation of the flocs

Cat. Coagulant Dosing Pump:


Dosing Pump
Type: Etatron or Equivalent.
Capacity & Pressure: 5 Liter/ hr. @ 5 bar.
Material of Construction: Polyethylene/PVDF
Power: 37 Watt.
Origin: Italy or Equivalent.
Qty : One
Tank:
Volume 100 Liter.
Material of Construction: Polypropylene.
Origin : Local.
Qty: One.

PAC Dosing Pump:


Dosing Pump
Type: Etatron or Equivalent.
Capacity & Pressure: 5 Liter/ hr. @ 5 bar.
Material of Construction: Polyethylene/PVDF
Power: 37 Watt.
Origin: Italy or Equivalent.
Qty : One
Tank:
Volume 100 Liter.
Material of Construction: Polypropylene.
Origin : Local.
Qty: One.
Anionic Coagulant Dosing Pump:
Type: Etatron or Equivalent.
Capacity & Pressure: 5 Liter/ hr. @ 5 bar.
Material of Construction: Polyethylene/PVDF
Power: 37 Watt.
Origin: Italy or Equivalent.
Qty : One

Tank:
Volume 100 Liter.
Material of Construction: Polypropylene.
Origin : Local.
Qty: One.

Electric Agitator (Flush Mixer) Unit:


It's consist of an electric motor, a gear box, a lantern, a shaft and two sloping blade impeller.
Diameter: 0.3 m.
Shaft Length: 1 m.
Treated Volume : Upto 3 m3.
Revolution Speed: 140 RPM.
Power Supply: 0.25 KW.
Origin: Local.
Qty: One.

Electric Agitator (Slow Mixer) Unit:


It's consist of an electric motor, a gear box, a lantern, a shaft and two sloping blade impeller.
Diameter: 0.5m.
Shaft Length: 1.3 m.
Treated Volume : Upto 10 m3.
Revolution Speed: 20 RPM.
Power Supply: 0.37 KW.
Origin: Local.
Qty: One.
2. Lamella Settler Basin
Lamella settlers usually come after a physical-chemical treatment to settle particles for water
clarification .Our settlers are built in galvanized steel.
Lamella clarifier is a water treatment process that features a core of inclined PVC /PS plates, which
cause flocculated material to precipitate from water that flows across the plates.
An Inclined plate settlers or lamella clarifiers are primarily used in the water and wastewater treatment
industries to separate solids from liquids in effluent streams.
Lamella package made from PVC/PS, Antistatic, and Consist of a series of sloped (55°:60°)
Tubes.
Material of Construction: Epoxy Coated Carbon Steel.
Dimension of tank: 1 m * 4 m * 1.5 m (H*L*W).
Settling Area: 20 m2.
Efficiency: 90:95%.
Origin: Local.
Qty : One

3. Filter Bag Unit


After clarification treatment of wastewater, participated flocs combined together and settles in
sludge hopper, Sludge pump sucked it to filter bag unit which made from Polyester fiber.
Pump Type: Submersible Pump
Capacity & Pressure: 10 LPM @ 4 bar.
Max. Air inlet Pressure: 1 bar.
Material of Construction: Poly/PTFE.
Inlet/outlet: 1 inch.
Origin: China or Equivalent.
Qty : One
4. Control panel

Control Panel consisting of Schneider works to control Automatic or


manual in operation, its components are provided after contracting.

MAIN DISCONNECT
This switch will interrupt all three phases of system power simultaneously.
This disconnect switch has to be turned off before accessing the control
panel enclosure, so the supply of hazardous voltage will be diminished for
security of personnel.

MOTOR STARTERS
These soft starter relays are located in electrical control enclosure.
Heavy duty rated relays will start and stop the pump motors

BREAKERS AND RELAYS


Breakers and relays will feature state-of-the-art components.

NEEDED REQUIREMENT TO BUILD UP THE UNIT:


 Area space (3 m X 10 m) with electric source and drainage.
 Provide 3 phases electric source (220 -380 Volte) inside the location
 Provide wastewater tank 20 m3 .

GUARANTEE
 Our company guarantee the wastewater treatment unit for a full year against
manufacture defects, but not against wrong usage.
 Company will provide the unit maintenance and consumed parts should be replaced
by our company.
FINANCIAL OFFER
Total price is 160,000 L.E (One Hundred and sixty thousand pounds only)

 Notes:
A price above doesn't include sales taxes.
Delivery time: 60 days after the P.O.

 Payment conditions:-
75% down payment with the P.O.
15% after supply.
10% after installation & operation immediately.

 Guarantee: one year against manufacturer defects.


 Validity: FOUR weeks

We hope that our offer meets your requirements and remain with best regards.

Yours,
Sales Manager.
Ahmed Hamam
01024230483