Sie sind auf Seite 1von 6

Page :1/6

UNIT-3 : HEAT BALANCE CALCULATION

Date : 9/8/2008 DOSING AIR :


Section : KILN TEMPERATURE (OC) : 34 HEAT OUTPUT (KCAL/Kg CLINKER) :
Calculations by :PROCESS DEPT VOLUME (NM /KG) :
3
0.088
PLANT CAPACITY TPD : 3500
AMB. TEMPERATURE ( C) : O
29 PRIMARY AIR : 1. HEAT FOR CLINKERISATION : 409.37
TEMPERATURE (OC) : 33 2. HEAT CARRIED BY PH EXHAUST GAS : 151.21
CLINKER COMPOSITION : VOLUME (NM3/KG) : 0.056 3. HEAT CARRIED BY COOLER EXHAUST GAS : 68.04
% SiO2 : 22.38 4. HEAT CARRIED BY PH EXHAUST GAS DUST : 3.18
% Al2O3 : 5.47 RADIATION LOSSES (kcal/Kg CLINKER): 5. HEAT FOR MOISTURE EVAPORATION : 4.95
% Fe2O3 : 4.20 KILN SHELL: 29.655 6. HEAT CARRIED BY CLINKER : 35.97
% CaO : 64.89 PREHEATER : 29.994 7. RADIATION LOSSES : 70.405
% MgO : 1.19 COOLER SIDE : 10.756 8. HEAT CARRIED BY BYPASS GAS : 0.00
HEAT CARRIED BY BYPASS DUST : 0.00
PH EXHAUST GAS : DECARBONISATION LOSS : 0.00
TEMPERATURE (OC) : 295 BYPASS :
VOLUME (NM3/KG) : 1.56 VOLUME AT KILN INLET (NM3/KG) : 0.00
DUST LOAD (gms/NM3) : 50 % BYPASS CONSIDERED : 0 TOTAL HEAT OUTPUT (KCAL/Kg CLINKER) : 743.12
GAS TEMP. AT KILN INLET (OC) : 0
RAW MEAL : DUST LOAD (gms/NM3) : 0
AMOUNT (Kg/Kg of CLINKER) : 1.6 HEAT INPUT (KCAL/Kg CLINKER) :
TEMPERATURE ( C) :O
60
MOISTURE (%) : 0.5
SP. HEAT OF AMBIENT AIR (KCAL/NM3) : 0.310 1. HEAT FROM COOLING AIR : 5.20
CLINKER : SP. HEAT OF PH. EXHAUST GAS (KCAL/NM ) :
3 0.352 2. HEAT FROM DOSING AIR : 0.38
TEMPERATURE (OC) : 204 SP. HEAT OF COOLER EXH. GAS (KCAL/NM3) : 0.320 3. HEAT FROM PRIMARY AIR : 0.23
SP. HEAT OF DOSING AIR (KCAL/NM3) : 0.311 4. HEAT FROM RAW MEAL : 13.71
COOLER EXHAUST GAS : SP. HEAT OF RAW MEAL (KCAL/Kg) : 0.214 5. HEAT FROM FUEL : 723.61
TEMPERATURE ( C) :O
239 SP. HEAT OF KILN DUST (KCAL/Kg) : 0.231
VOLUME (NM3/KG) : 0.970 SP. HEAT OF CLINKER (KCAL/Kg) : 0.195
SP. HEAT OF DUST AT KILN INLET (KCAL/Kg) : 0.209 TOTAL HEAT INPUT (KCAL/Kg CLINKER) : 743.12
COOLING AIR : SP. HEAT OF GAS AT KILN INLET(KCAL/NM ) :
3 0.323

Calculation by: B.Ravindran


Page :2/6
UNIT-3 : HEAT BALANCE CALCULATION

TEMPERATURE (OC) : 29
VOLUME (NM3/KG) : 1.86

Note: Raw Meal to Clinker Factor = 1.60 kg / kg clinker.

Calculation by: B.Ravindran


Page :3/6
UNIT-3 : HEAT BALANCE CALCULATION

PH EXHAUST GAS : RAW MEAL : CLK. TEMPERATURE (OC) : 204


TEMPERATURE (OC) : 295 Kg/Kg of CLINKER : 1.6 COOLER EXHAUST GAS :
VOLUME (NM3/KG) : 1.56 TEMPERATURE (OC) : 60 TEMPERATURE (OC) : 239
DUST LOAD (gms/NM3) : 50 MOISTURE (%) : 0.5 VOLUME (NM3/KG) : 0.97
409.37
151.21
68.04 HEAT OUTPUT KCAL/ Kg CLINKER HEAT INPUT KCAL/ Kg CLINKER
3.18
4.95 Clinkerisation
35.97 55.09% 409.37 Sensible heat cooling air
70.405 5.20
0.00 PH Exhaust gas
0.00 20.35% 151.21
0.00 Sensible heat dosing air
Cooler Exhaust gas 0.38
9.16% 68.04
743.12
PH Exhaust dust PLANT CAPACITY Sensible heat primary air
0.43% 3.18 3500 TPD 0.23

Moisture AMB. TEMP.


0.67% 4.95 29 OC Sensible heat raw meal
5.20 13.71
0.38 Exit clinker
0.23 4.84% 35.97
13.71 FUEL
723.61 Radiation losses 723.61
9.47% 70.405

743.12 By pass losses


0.00% 0.00

Calculation by: B.Ravindran


Page :4/6
UNIT-3 : HEAT BALANCE CALCULATION

743.12 TOTAL HEAT INPUT (KCAL/Kg CLINKER) :

Calculation by: B.Ravindran


Page :5/6
UNIT-3 : HEAT BALANCE CALCULATION

COOLING AIR :
TEMPERATURE (OC) : 29
VOLUME (NM3/KG) : 1.86
DATE: 9/8/2008

HEAT INPUT KCAL/ Kg CLINKER

0.70%

0.05%

0.03%

1.84%

97.37%

Calculation by: B.Ravindran


Page :6/6
UNIT-3 : HEAT BALANCE CALCULATION

TOTAL HEAT INPUT (KCAL/Kg CLINKER) : 743.12

Calculation by: B.Ravindran