EC Formulation DUCT -1 & 2 Charcoal Tower Sizing
Re 2864.92
fp 1.802
Using Ergun equation we can find pressure drop across tower
∆p Charcoal Tower Pr. Drop 898.022
0.8980
0.0090
6.825
∆p1 Tower Pressure Drop 92
Duct Line Loss Calculation
Re Reynold's No for gas th' duct 261935.483870968
f Friction Factor 0.0139858186
∆p2 100.1224773729
0.1001224774
0.751
∆p2 Duct Pressure Loss 10
mmwc
mmwc
m3/hr
mm
m/s
m3/hr
mm
Kg/m3
Kg/m s
Kg/m3
m/s2
mm
mm
m2
m/hr
m/s
pa
Kpa
Bar
mmhg
mmwc
on
pa
Kpa
mmhg
mmwc
pa
Kpa
mmhg
mmwc
mmwc
mmwc
m2
Kg
kg/m3
m
mm
Charcoal Tower Costing
Thickness of tower 6 mm
Volume of Tower 1.88E-01 m3
Density of MS 8000 Kg/m3
Total Weight 1507.2 Kg
MS Material+ Fabrication 150 Rs.
Cost of Tower 226080 Rs.
Nozzle, Leg, Plate, Railing 100000 Rs.
Total 326080 Rs.
Basis:-
1. Charcoal Tower sizing is based on available pressure drop/ blower suction & volumetric capacity of blowe
2. 8 mm size Activated Carbon Granuals to be used as adsorbent for organics removal from inlet gases.
3. Charcoal Tower MOC considered MS with Epoxy coating on all the contact parts.
`
apacity of blower.
inlet gases.
n
Cost (Lakh)
7.60
2.50
1.00
0.50
2.50
14.10
15.51
15.50
Barchart for Odour Removal System Installation in EC formulation
March-19 April-19
1 Both Tower Inlet & Outlet Flange to be fabricated from M/S Guruji. To be communicate with simit/dharmit
2 Both Tower Inlet & Outlet Flange must be Loose with Stubend
3 For D-2 Tower one GI Spoole piece is required to fabricated from M/S Guruji
4 Service PR for Epoxy coating inside both tower & Holding plate to be raised
5 Activated Charcoal 8 mm particle size 1.2 T PR to be raised