Fire Hydrant

Design High Flow Fire Hydrant


Fire Monitor
Flange With FM Flange Without FM Flange
Breakaway With BCV Without BCV With BCV Without BCV
Check Valve*
Body Ductile Iron Bronze Ductile Iron Bronze
Material****

Other: Other:
Underground 4" Riser with 6" Riser with 6" Riser with 4" Riser with 6" Riser with 6" Riser with
Riser Size and 8 holes 4" Riser with 8 holes 8 holes 4" Riser with 8 holes
8 holes (ANSI) 8 holes (ANSI) 8 holes (ANSI) 8 holes (ANSI)
Flange (ANSI) Default for (ANSI) Default for Other: (ANSI) Default for (ANSI) Default for Other:
Specifications Old 509 riser Old 509 riser
(Note 1) new Old 509 riser new (Note 1) new Old 509 riser new
at Facility facilities facilities facilities facilities
(Note 1) (Note 1)

Count of each

Water TDS
(ppm)

Pumper Outlet 5" unthreaded nozzle (Storz Connection) for areas responded primarily by Fire Protection Department
(choose one
type only;
other sizes are
not
allowed)**
4.5" NST threaded nozzle for areas responded primarily by Civil Defense

Saudi Aramco: Company General Use


Will be
installed in
Potable Water
System
(Indicate Yes
or No)**

Number of
Wrenches***

*Check SAES-B-017 to decide on which fire hydrants will need BCV.


**Fill one form for each fire water system to avoid mixing coating requirment and pumper nozzle type.
***Puchaser should estimate the needed number of wrenches based on actual need.
****Bronze bodies shall only be selected if the service conditions are extremely corrosive (untreated seawater, high ammonia/TDS/chlorides).

Note 1 For the the purchaser: The use of an adapter may cause the BCV burry line to be elevated above finished ground level; this installation will defeat the purpose of the BCV. If this is the
case, it is required to modify the 4" or 8" undergorund riser flange at site to be a standard 6" ANSI flange to avoid using any adapters.
For the Vendors: Vendor shall indicate if the fire hydrant base flange is other than the standard flange (Standard : 6" ANSI with 8 holes).

Fire Hydrant
Design Offshore Fire Hydrant
Other:

Underground 4" Riser


Riser Size and with 8
Flange holes
Specifications (ANSI)
at Facility Old 509 (Note 1)
riser
(Note 1)
Count of each

Saudi Aramco: Company General Use


Fire Hydrant
Design Temporary Construction Camp Fire Hydrant
Other:

Underground 6" Riser


Riser Size and with 8
Flange holes
Specifications (ANSI)
at Facility Default for (Note 1)
new
facilities
Count of each

Water TDS
(ppm)

Fill This Table if You Are Purchasing only BCVs


Without Fire Hydrants
Other:

Underground
Riser Size and
Flange 4" Riser 6" Riser (Note 1)
Specifications with 8 with 8
at Facility holes holes
(ANSI) (ANSI)
Old 509 Default for
riser new
(Note 1) facilities

Saudi Aramco: Company General Use


Brand and
model and
Count of
each*
(Brand and
Model are
important to
ensure
compatilbity)

*see below example


Fill This Table if You Are Purchasing only BCVs
Without Fire Hydrants (example)
Other:
Undergrou
nd Riser 4" Riser 6" Riser
Size and with 8 with 8
Flange holes holes
Specificatio (ANSI) (ANSI)
ns at Old 509 Default for (Note 1)
Facility riser new
(Note 1) facilities

4 AVK model 20- 8 AVK model 20-


Brand and 90 90
model and 6 James Jones 1 James Jones
Count of model 4060 model 4060
3 Clow model 2 Clow model
each 850 850