Weekly Elevator Inspection Checklist.

Before you start - Inform ECR. Tick the box if step completed. ☒
1. Place the warning notice signs on each floor. ☐
2. Call the elevator to main deck (4th level) secure the front door.
3. Insert the Otis key №1 to keep car’s rea door in park position. ☐
4. Use the Vacuum cleaner with narrow adapter for sliding doors travel space cleaning. ☐
5. Go to 8th floor and cleaned the car’s front sliding doors travel space ☐
6. Proceed to main deck (4th level) and bring the elevator car in service position.
7. Activate the RTES (em.stop) and set TCIB to “SERVICE” ☐
8. Check rear SUPRA device for:
• Mounting bolts and screws properly tight. ☐
• Clean the rails with dry cloth. ☐
• Check tension of ropes. ☐
• Check condition and tension of the driving belt ☐
• Check limit switches for proper position and screw tightness ☐
9. Check rear sliding doors:
• Gap between doors in closed position. ☐
• The adjustable bolts tightness. ☐
• Operation of sliding doors in service mode. ☐
10. PRS reader:
• Check reader’s shoes for proper mounting. ☐
• Check gap between PMS reader and guide plate. ☐
• PRS reader wiring connector ☐
• PRS reader mounting screws ☐
11. Front door and Hoistway inspection:
• Enter on top of elevator car, close the front deck door ☐
• Release the RTES (em.stop) ☐
• Ropes connections (car ropes) in good condition and tight ☐
• Drive the elevator to 2-nd floor (ECR floor)
• Activate the TES (em. Stop), open and secure the deck door ☐
12. Check Front SUPRA device for:
• Mounting bolts and screws properly tight. ☐
• Clean the rails with dry cloth. ☐
• Check tension of ropes. ☐
• Check tension of the driving belt ☐
• Check limit switches for proper position and screw tightness ☐

Date: Signature:
13. Check front sliding doors:
• Gap between doors in closed position. ☐
• The adjustable bolts tightness. ☐
• Operation of sliding doors in service mode. ☐
14. Enter inside the Hoistway, close the 2 –nd floor door and release the TES ☐
• Travel to lower flat, the elevator will stop itself when it reach the lower point ☐
15. Travel from lower flat to top of hoistway.
16. Counterweight inspection:
• All lower and upper sides bolts, secured ☐
• Ropes are in good condition ☐
17. Lightning and Magnets.
• All light fixtures in good condition and illuminate. ☐
• All level magnets in good order and on right places ☐
18. Top of hoistway:
• When you reach the upper car’s position, it stops itself by limit switch 6LS ☐
• Check blocks for cracks and proper position ☐
• OS 1 and OS 2 in good condition ☐
20. Drive to main deck (4th floor):
• Activate the RTES ☐
• Open the deck door and secure it ☐
• Collect all tools and materials ☐
• Check position of SCS (em. escape hatch) ☐
• Check SOS (safety operated switch) position ☐
• Set the TCIB to “NORMAL” ☐
• Check both supra board control, set to Normal ☐
• Release the RTES and close the deck door ☐
21. Call the elevator to 4th deck
• Collect all warning notice signs ☐
• Check for any abnormal elevator behavior ☐
• Check for any unusual noise when traveling up and down ☐
22. Elevator machinery room:
• Machinery room fan in operation ☐
• The elevator control cabinet’s fan in good condition ☐
• The filters in good condition, replace if require ☐
• Clean transformer, cabinet, electrical motor surfaces with dry cloth ☐

Date: Signature: