STUDY OF SEISMIC ANALYSIS ON RC BUILDING


1 2
Author , Author ,
Introduction:

● Post tension slab are not complex where the construction technique, structure
behaviour and design are all simple.
The tendon install provide a suspension system within the slab and the simple
balancing load were used.
● This project focuses on studying the behaviour of PT slab and conventional slab
using Staad Pro.
● In this study response of the building with conventional slab and PT slab in
zone 2 and zone 5 subjected to earthquake load is analyzed by response
spectrum method.
● The different Spectral accelerations of the buildings with respect to time are
plotted in the response spectrum graph are compared for the results along with
the story displacement.
● A comparison study was done to identify the Response of the multi-story
building with different slab system during seismic analysis.
Results:

1. Displacement in Z- direction is more when compared to displacement in


X-direction.
Literature:
Ilinca Moldovan, Aliz Mathe (2015): Post-tensioned construction has for a long 2. There is no sudden change in displacement.
period of time occupied a significant position, especially in the construction of
bridges, storage tanks, but also in buildings. 3. When there is increase in the no of story Displacement is also increasing.
● In this paper are presented the aspects of a square shaped waffle slab calculation,
supported punctually and having a two-way post tensioning reinforcement 4.1Conventional slab responds for lateral loads at a frequency of 6.525cyc/sec in a
disposed parabolically. short period of 0.15326sec.
Sreenivasa Prasad Joshi (2016): Post-tensioned slabs are a preferred method for
industrial, commercial and residential floor slab construction. The increasingly
5.1. Displacement in X- direction is more inwhen compared to displacement in
extensive use of this method is due to its advantages and its nature of easy
application to a wide variety of structure geometry and design solutions. Z-direction.
● The use of post-tensioned floor slabs and reinforced concrete core walls has
become increasingly popular in high-rise construction. Conclusions:
Methodology: 1. The performance of building with conventional slab was observed to be
better when compared with the building with the post tension slab in the case of
3.5. Creation of Model in the STAAD PRO:
seismic Zone – 2.

● Creating new model : 2. In case of Zone – 5 it is observed that maximum displacement is 22.87% is

● Creating basic grid data more in Post Tension slab when compared to conventional slab with some

● Defining Material Properties measures like ductile detailing.

● Assigning supports 3. Displacement of the Post Tension slab is 1.35 times more at 3rdstory when
● Section property compared to conventional slab.

● Assigning loads
● Analyse the structure

 Important References:
● Creating grid in SAFE 

• 1. IS 456:2000, “Indian Standard Plain and reinforced concrete-Code of

 Practice”, Bureau of Indian Standards, New Delhi, 2000.
• 2. SP 16: Design Aids for Reinforced Concrete to IS 456:2000.
• IS-875 part 1 (Code of practice for design loads (other than earthquake) for
buildings