Sie sind auf Seite 1von 15

1

12
7
10

11

4
3

2
1

ITEM PART NUMBER DESCRIPTION QTY Torque Length


NO.
1 SRM EXTRUDE 2.4 Spyder Rail (10', 17', 20') 2 126"
2 SRM EXTRUDE 2.4 Splice 16" 2 16"
3 SRM EXTRUDE 2.4 Extension Rail 2 24"
4 SRM FOOT 1.0 Aluminum Foot 8
5 B18.2.3.4M - Hex flange screw, M8 x 16mm Serrated Flange 8 10 ft/lbs 16mm
M8 x 1.25 x 16 --16N Bolt
6 Roll in T-slot nut 13x10 Roll-in-nut for Foot and Splice 12 tel: 905-532-0770 520 Applewood Cresent
fax: 905-532-0593 Vaughan ON, L4K 4B4
7 Enphase M 215 Inverter 3
www.sentinelsolar.com
8 096HS081904M0820ES02 M8 x 20mm T-Bolt 3 20mm
9 B18.2.2.4M - Hex flange nut, M8 x M8 Serrated Flange Nut 3 10 ft/lbs
PROPRIETARY AND CONFIDENTIAL
1.25 --N THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE

10 Solgate 210-260 Module Solar Panel 3


PROPERTY OF Sentinel Solar. ANY REPRODUCTION IN PART OR
Assembly AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
Sentinel Solar IS PROHIBITED.
11 Single Module Clamp Assembly 46mm Clamp 4 5 ft/lbs
12 Dual Module Clamp Assembly Dual Module Clamp 4 5 ft/lbs Drawn By
DWG. NO. REV

13 B18.2.3.1M - Hex cap screw, M8 x M8 x 40mm Bolt for Splice 4 10 ft/lbs 40mm
AW SRM 2.4 Assembly Manual
0
1.25 x 40 --40N
14 Metal Roof Foot Gasket Rubber Mounting Gasket 8
(Metal Roof's Only) SCALE: 1:18 SHEET 1 OF 8
5 4 3 2 1
Mounting Foot to SRM Rail 2

Start by installing a foot at the first truss, then another


at the last truss (first/last truss for the length of rail
being used). A chalk line may be required to ensure
the rail lines up properly. A length of rail can then be
installed at the desired height.
Now you have a level rail even if the roof itself is not.
The rest of the feet can then be installed.

Push the Roll-in-Nut into the rail with you're thumb


and slide it into the approximate position. Thread
the M8 x 16mm Bolt into the Roll-in-Nut just enough
so it stays. You can then slide the SRM Rail onto the
foot and torque the bolt at the desired height.

Note:
14
The bolt hole on the foot Note:
must ALWAYS be on the
high end of the slope. Rubber Foot Gasket only
applies to metal roof's. It is not tel: 905-532-0770 520 Applewood Cresent
required for asphalt roof's. fax: 905-532-0593 Vaughan ON, L4K 4B4

www.sentinelsolar.com
PROPRIETARY AND CONFIDENTIAL
ITEM PART NUMBER DESCRIPTION QTY THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
NO. PROPERTY OF Sentinel Solar. ANY REPRODUCTION IN PART OR
1 SRM EXTRUDE 2.4 Spyder Rail (10', 17', 20') 2 AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
Sentinel Solar IS PROHIBITED.
4 SRM FOOT 1.0 Aluminum Foot 8
B18.2.3.4M - Hex flange screw, DWG. NO. REV
5 M8 x 1.25 x 16 --16N M8 x 16mm Serrated Flange Bolt 8 Drawn By

6 Roll in T-slot nut 13x10 Roll-in-nut for Foot and Splice 8


AW SRM 2.4 Assembly Manual
0
14 Metal Roof Foot Gasket Rubber Mounting Gasket 8 SCALE: 1:2 SHEET 2 OF 8
5 4 3 2 1
Height Options for Mounting Foot 3

At MAX height,
minimum engagement
for teeth on foot to be 2

Note:
Depending where the SRM Foot
lands, it may need to be trimmed
at minimum height.

tel: 905-532-0770 520 Applewood Cresent


fax: 905-532-0593 Vaughan ON, L4K 4B4

www.sentinelsolar.com
2.98" MAX

5.15" MAX
1.25" MIN

3.41" MIN
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF Sentinel Solar. ANY REPRODUCTION IN PART OR
AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
Sentinel Solar IS PROHIBITED.

Drawn By
DWG. NO. REV
AW SRM 2.4 Assembly Manual
0
Bottom of Rail Bottom of Module
SCALE: 1:1 SHEET 3 OF 8
5 4 3 2 1
Foot Placement 4

Starting and end of


rails will have 2 feet
Existing Roof Truss Installed Blocking per truss as shown.

Refer to Module
Specifications
36-48"

To match
purlin/strapping
spacing, if applicable.

48" 24"
Note: Actual dimensions to match truss spacing
tel: 905-532-0770 520 Applewood Cresent
If truss spacing is less than 36", foot fax: 905-532-0593 Vaughan ON, L4K 4B4
placement can be staggered as
shown. Anymore than 36", every www.sentinelsolar.com
truss/blocking must be used.
PROPRIETARY AND CONFIDENTIAL
EVERY TRUSS UNDER THE SOLAR THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
SYSTEM IS TO BE PENETRATED PROPERTY OF Sentinel Solar. ANY REPRODUCTION IN PART OR
AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
Sentinel Solar IS PROHIBITED.

Drawn By
DWG. NO. REV
AW SRM 2.4 Assembly Manual
0
SCALE: 1:15 SHEET 4 OF 8
5 4 3 2 1
Mounting Inverters 5

7
10

Note:
WEEB washer is optional, grounding
8 the inverter can also be done using
a #6 bare copper wire or what is
recommended by electrician.

The inverter may not slide


right up until the bolt
The inverter mounts so that the brushed reaches the end of the
steel plate faces up. It will slide onto the bracket's slot.
rail until the inverter touches the side of
the rail.

tel: 905-532-0770 520 Applewood Cresent


fax: 905-532-0593 Vaughan ON, L4K 4B4

www.sentinelsolar.com
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF Sentinel Solar. ANY REPRODUCTION IN PART OR
ITEM PART NUMBER DESCRIPTION QTY AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
NO. Sentinel Solar IS PROHIBITED.
7 Enphase M 215 Inverter 3
DWG. NO. REV
8 Weeb SMC Grounding WEEB Washer 3 Drawn By

9 096HS081904M0820ES02 M8 x 20mm T-Bolt 3


AW SRM 2.4 Assembly Manual
0
B18.2.2.4M - Hex flange nut,
10 M8 x 1.25 --N M8 Serrated Flange Nut 3 SCALE: 1:4 SHEET 5 OF 8
5 4 3 2 1
Inverter Placement 6

Note:
This only applies if there are additional rows
and therefore may not apply to all systems.

Install inverters on additional rows


so that one row uses the top rail
and the other row uses the bottom
rail.
This will help maximize the use of
the Enphase trunk line.

40.00 21.5
May differ depending on module

tel: 905-532-0770 520 Applewood Cresent


fax: 905-532-0593 Vaughan ON, L4K 4B4

www.sentinelsolar.com
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF Sentinel Solar. ANY REPRODUCTION IN PART OR
AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
These dimensions are approximate. The 21.5" from the Sentinel Solar IS PROHIBITED.
end of the rail includes a 2.25" space so that the first
panel does not sit at the edge of the rail. Drawn By
DWG. NO. REV
Inverters mount so they are approximately centered AW SRM 2.4 Assembly Manual
0
under their corresponding panel.
SCALE: 1:20 SHEET 6 OF 8
5 4 3 2 1
Installing Modules 7

Note:
Dual and Single module
clamps use this 'ClicLoc'
connection system.

A
As the bolt tightens, the 'bell'
raises and spreads the claws
which then grab the rail.
Be sure to keep all the panels Torque to 5 ft/lbs
flush at the ends and
centered between the rails.

12

10

11

Single Module clamps are only


used on the first and last panels in a
row. All others are fastened down
using the Dual Module Clamp.

tel: 905-532-0770 520 Applewood Cresent


fax: 905-532-0593 Vaughan ON, L4K 4B4

www.sentinelsolar.com
PROPRIETARY AND CONFIDENTIAL

DETAIL A THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE


PROPERTY OF Sentinel Solar. ANY REPRODUCTION IN PART OR

SCALE 1 : 10 ITEM
AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
Sentinel Solar IS PROHIBITED.

NO. PART NUMBER DESCRIPTION QTY


Solgate 210-260 Module DWG. NO. REV
10 Assembly Solar Panel 3 Drawn By

11 Single Module Clamp 46mm Clamp, Torque to 5 ft/lbs 4


AW SRM 2.4 Assembly Manual
0
Assembly
Dual Module Clamp
12 Assembly Dual Module Clamp, Torque to 5 ft/lbs 4 SCALE: 1:30 SHEET 7 OF 8
5 4 3 2 1
Splicing Rails 8

2 6

tel: 905-532-0770 520 Applewood Cresent


13 fax: 905-532-0593 Vaughan ON, L4K 4B4
Splice use to connect a row of rails together
to make one continuous length of rail.
www.sentinelsolar.com
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF Sentinel Solar. ANY REPRODUCTION IN PART OR
ITEM PART NUMBER DESCRIPTION QTY AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
NO. Sentinel Solar IS PROHIBITED.
2 SRM EXTRUDE 2.4 Splice 16" 2
Drawn By
DWG. NO. REV
3 SRM EXTRUDE 2.4 Extension Rail 2
6 Roll in T-slot nut 13x10 Roll-in-nut for Foot and Splice 4
AW SRM 2.4 Assembly Manual
0
13 B18.2.3.1M - Hex cap screw, M8 x 40mm Bolt 4
M8 x 1.25 x 40 --40N SCALE: 1:20 SHEET 8 OF 8
5 4 3 2 1
SRM Splice Installation 9

Splice piece is rotated 180 and


flipped upside down so that it can
slide into the adjacent rails.

The splice piece has 2 pre-drilled holes through


it; these holes are used with the Bolt Cleat and
an M8 x 40mm bolt. The bolt is tightened
against the adjacent rail so that the splice can
no longer slide. The attaching rail will then slide tel: 905-532-0770 520 Applewood Cresent
into the splice and the same procedure is fax: 905-532-0593 Vaughan ON, L4K 4B4
followed.
www.sentinelsolar.com
PROPRIETARY AND CONFIDENTIAL

Building your own splice can be done by THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF Sentinel Power Sysetms Inc. ANY REPRODUCTION IN
using any off-cut piece of rail and drilling 2
PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
holes with the use of the groove in the Sentinel Solar Corp. ISPROHIBITED.
channel as a guide.
Drawn By
DWG. NO. REV
AW Splice Assembly 2.4
0
SCALE: 1:5 SHEET 1 OF 1
5 4 3 2 1
Asphalt Roof Installation 10

Foot Detail
Optional flashing kit can be used as added
protection over mounting foot and lag screws.
An appropriate sealant/adhesive is to be used
to secure the flashing to the roof.

See flashing manual for installation instructions.


Height of panels can be fully adjusted
for height differences in the roof
along the length of the rail. Height
variance of approximately 1 3/4" is
possible.

1.
00
Use rubber backed washer to seal
bolt head to top of mounting foot

Use an appropriate
sealant/adhesive to seal foot
to roof surface
Use 5/16" x 3" galvanized lag screws
to secure mounting foot to roof.
Minimum thread length of 2"

Minimum engagement of 2" into


roof truss, blocking or purlins. If 1.0 Asphalt Shingles
blocking is used it is to match top 0
cord.

Roof Sheeting

Roof Truss
tel: 905-532-0770 520 Applewood Cresent
fax: 905-532-0593 Vaughan ON, L4K 4B4

www.sentinelsolar.com
PROPRIETARY AND CONFIDENTIAL

Installation Note: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE


PROPERTY OF Sentinel Solar. ANY REPRODUCTION IN PART OR
Installer to take all necessary precautions to ensure that the AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
potential for roof leaks are minimized, use of an Sentinel Solar IS PROHIBITED.
appropriate sealant/adhesive is recommended.
Drawn By
DWG. NO. REV
AW Roof Assembly
1.0
SCALE: 1:5 SHEET 1 OF 1
5 4 3 2 1
Metal Roof Installation 11
Foot Detail

Use 5/16" x 3" galvanized lag screws Height of panels can be fully
to secure mounting foot to roof. adjusted for height differences
Minimum thread length of 2" in the roof along the length of
the rail. Height variance of
Minimum engagement of 2" into approximately 1 3/4" is
roof truss, blocking, or purlins. possible.
If blocking is used, it is to match top
cord.
Use rubber backed washer to seal
bolt head to top of mounting foot

Rubber gasket to separate


roof from foot, and to provide
water proofing barrier. Only
use gasket supplied by
Sentinel Solar.

Steel Roof Sheet

Roof Sheeting

Roof Truss tel: 905-532-0770 520 Applewood Cresent


fax: 905-532-0593 Vaughan ON, L4K 4B4

www.sentinelsolar.com
PROPRIETARY AND CONFIDENTIAL

Installation Note: THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE


PROPERTY OF Sentinel Solar. ANY REPRODUCTION IN PART OR
AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
Installer to take all necessary precautions to ensure that the Sentinel Solar IS PROHIBITED.
potential for roof leaks are minimized, use of an
appropriate sealant/adhesive is recommended.
Drawn By
DWG. NO. REV
AW Metal Roof Assembly
1.0
SCALE: 1:5 SHEET 1 OF 1
5 4 3 2 1
12

4.0 48.0 24.00

1 4
2 5

tel: 905-532-0770 520 Applewood Cresent


ITEM PART NUMBER DESCRIPTION Length Used QTY
fax: 905-532-0593 Vaughan ON, L4K 4B4
NO.
www.sentinelsolar.com
1 SRM EXTRUDE 2.4 Spyder Rail (10', 17', 20') 10' 2
PROPRIETARY AND CONFIDENTIAL
2 SRM FOOT 1.0 Aluminum Foot 8 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF Sentinel Solar. ANY REPRODUCTION IN PART OR
3 Roll in T-slot nut 13x10 Roll-in-nut for Foot 8 AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
Sentinel Solar IS PROHIBITED.
4 Enphase M 215 Inverter 3
5 Solgate 210-260 Module Solar Panel 3 Drawn By
DWG. NO. REV
Assembly
6 Single Module Clamp Assembly 46mm Clamp, Torque to 5 ft/lbs 4
AW SRM 2.4 Assembly x3
0
7 Dual Module Clamp Assembly Dual Module Clamp, Torque to 5 ft/lbs 4 SCALE: 1:20 SHEET 1 OF 1
5 4 3 2 1
13

24.0 48.0

11.0 48.0
1 2 4 5

tel: 905-532-0770 520 Applewood Cresent


fax: 905-532-0593 Vaughan ON, L4K 4B4
ITEM PART NUMBER DESCRIPTION Length Used QTY
NO.
www.sentinelsolar.com
1 SRM EXTRUDE 2.4 Spyder Rail (10', 17', 20') 17' 2
PROPRIETARY AND CONFIDENTIAL
2 SRM FOOT 1.0 Aluminum Foot 11 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF Sentinel Solar. ANY REPRODUCTION IN PART OR
3 Roll in T-slot nut 13x10 Roll-in-nut for Foot 11 AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
Sentinel Solar IS PROHIBITED.
4 Enphase M 215 Inverter 5
5 Solgate 210-260 Module Solar Panel 5 Drawn By
DWG. NO. REV
Assembly
6 Single Module Clamp Assembly 46mm Clamp, Torque to 5 ft/lbs 4
AW SRM 2.4 Assembly x5
0
7 Dual Module Clamp Assembly Dual Module Clamp, Torque to 5 ft/lbs 8 SCALE: 1:25 SHEET 1 OF 1
5 4 3 2 1
14

24.0 48.0

3.0 1 2 4 5
48.0

tel: 905-532-0770 520 Applewood Cresent


fax: 905-532-0593 Vaughan ON, L4K 4B4
ITEM PART NUMBER DESCRIPTION Length Used QTY
NO.
www.sentinelsolar.com
1 SRM EXTRUDE 2.4 Spyder Rail (10', 17', 20') 20' 2
PROPRIETARY AND CONFIDENTIAL
2 SRM FOOT 1.0 Aluminum Foot 13 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF Sentinel Solar. ANY REPRODUCTION IN PART OR
3 Roll in T-slot nut 13x10 Roll-in-nut for Foot 13 AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
Sentinel Solar IS PROHIBITED.
4 Enphase M 215 Inverter 6
5 Solgate 210-260 Module Solar Panel 6 Drawn By
DWG. NO. REV
Assembly
6 Single Module Clamp Assembly 46mm Clamp, Torque to 5 ft/lbs 4
AW SRM 2.4 Assembly x6
0
7 Dual Module Clamp Assembly Dual Module Clamp, Torque to 5 ft/lbs 10 SCALE: 1:25 SHEET 1 OF 1
5 4 3 2 1
15

24.0 48.0

6.0 1 3 1 6 7
48.0

ITEM PART NUMBER DESCRIPTION Length QTY


NO.
1 SRM EXTRUDE 2.4 Spyder Rail (10', 17', 20') 10' 4 tel: 905-532-0770 520 Applewood Cresent
fax: 905-532-0593 Vaughan ON, L4K 4B4
2 SRM EXTRUDE 2.4 Splice 16" 16" 2
www.sentinelsolar.com
3 SRM FOOT 1.0 Aluminum Foot 13
PROPRIETARY AND CONFIDENTIAL
4 Roll in T-slot nut 13x10 Roll-in-nut for Foot and Splice 17 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE

5 B18.2.3.1M - Hex cap screw, M8 x 40mm Bolt for Splice 40mm 4


PROPERTY OF Sentinel Solar. ANY REPRODUCTION IN PART OR
M8 x 1.25 x 40 --40N AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
Sentinel Solar IS PROHIBITED.
6 Enphase M 215 Inverter 6
7 Solgate 210-260 Module Solar Panel 6 Drawn By
DWG. NO. REV
Assembly
8 Single Module Clamp 46mm Clamp, Torque to 5 ft/lbs 4
AW SRM 2.4 Assembly x6 splice
0
Assembly
9 Dual Module Clamp Assembly Dual Module Clamp, Torque to 5 ft/lbs 10 SCALE: 1:25 SHEET 1 OF 1
5 4 3 2 1

Das könnte Ihnen auch gefallen