Copyright and Trademark Notices

This document contains information that is protected by copyright. All rights are reserved. No part
of this document may be photo copied, reproduced or translated to another language without prior
written consent of Contec Medical Systems Co., Ltd. The information contained in this document
is subject to change without notice.

Responsibility of the User


 KT88-3200 digital brain electric activity mapping should be used by the physicians who have
received professional training.
 The user should read this operational manual carefully before operating KT88-3200, and
operate it in accordance with the manual.
 The user should observe KT88-3200 and the patient when operating it.
 The user is responsible to supply the use situations of KT88-3200 to Contec Medical Systems
Co., Ltd.

Responsibility of Contec Medical Systems Co., Ltd


 Contec Medical Systems Co., Ltd supplies the standard product to the user.
 Contc Medical Systems Co., Ltd installs and debugs KT88-3200 and trains the physicians.
 KT88-3200 should be repaired by Contec Medical Systems Co., Ltd.
 Contec Medical Systems Co., Ltd should use original accessories to repair KT88-3200.
 Contec Medical Systems Co., Ltd is responsible to answer the questions about KT88-3200 on
time.

Other Important Information


The information in this document is subject to change without notice.

Contec Medical Systems Co., Ltd makes no warranty of any kind with regard to this material,
including, but not limited to implied warranties of merchant ability and fitness for a particular
purpose. Contec Medical Systems Co., Ltd assumes no responsibility for any errors of omissions
that may appears in this document. Contec Medical Systems Co., Ltd makes no commitment to
update nor to keep current the information contained in this document.

Warranty Information
Your CONTEC Warranty

Contec Medical Systems Co., Ltd (hereinafter referred to as “ Contec”) hereby warrants that
Contec products (hereinafter referred to as “Products”) shall be free from defects in material and
workmanship under normal use, service and maintenance for the warranty period of such Product
from Contec or an authorized distributor or representative of Contec Normal use, service and
maintenance means operation and maintenance in accordance with appropriate instructions and/or
information guides. This Warranty does not apply to the Products caused by any or all of the
following circumstances or conditions:
 Freight damage;

I
 Part and/or accessories of the Products not obtained from or approved by Contec;
 Misapplication, misuse, abuse, and failure to follow the Product instruction sheets and/or
information guides;
 Accident, a disaster affecting the Products;
 Alterations or modifications to the Products not authorized by Contec;
 Other events outside of Contec ’s reasonable control or not arising under normal operating
conditions.
The remedy under this warrenty is limited to the repair or replacement without charge for labor or
materials, or any productrs found upon examination by contec to have been defective. This
remedy shall be conditioned upon receipt of notice by contec of any alleged defects promptly after
discovery thereof within the warranty period. Contec ’s obligation under the foregoing warranty
will further be conditioned upon the assumption by the purchase of the products ( ⅰ) of all carrier
charges with respect to any products returned to contec’s principal place or any other place as
specifically designated by contec or an authorized distributor or representative of contec, and ( ⅱ)
all risks of loss in transit. It is expressly agreed that the liability of contec is limited and that
contec does not function as an insurer. A purchase of a product, by its acceptance and purchase
thereof, acknowledges and agrees that contec is not liable for loss, harm or damage due directly or
indirectly to an occurrence or consequence therefrom relating to the products. If contec should be
found liable to anyone under any theory (except the expressed warranty set forth herein) for loss,
harm or damage, the liability of contec shall be limited to the lesser of the actual loss, harm or
damage, or the original purchase price of the product when sold.
Excluded from the limited warranty set forth above are consumable items such as paper, batteries,
electrodes, patient cable, lead wires and magnetic storage mediums.
Except as set forth herein with respect to reimbursement of labor chages, a purchase’s sole
exclusive remedy against contec for claims relating to the products for any and all losses and
damages resulting from from any cause shall be the repair or replacement of defective products to
the extent that the defect is notice and contec is notified within the warranty period. In no event,
including the claim for negligence, shall contec be liable for incidental, special or consequential
damages, or for any other loss, damage or expense of any kind, including loss of profits, whether
under tort, negligence or atrict liability theories of law, or otherwise. This warranty is expressly in
lieu of any other warranties, express or implied, including, but not limited to the implied warranty
of merchant ability and the warranty of fitness for a particular purpose.
Preface
This operation manual introduces you the total function of the KT88-3200 digital brain electric
activity mapping and the detail operation procedure.
Please read the manual carefully before use the machine, which makes you easier to use it.

II
Table of Contents

Chapter 1 Introduction....................................................................................................................1

Chapter 2 The main technical index..............................................................................................1

Chapter 3 Technical device..............................................................................................................2

Chapter 4 Software and Hardware setup Wizard........................................................................3

Chapter 5 The system operation...................................................................................................13

Chapter 6 Notice.............................................................................................................................37

III
Chapter 1 Introduction
The features of digital brain electric activity mapping:
The digital brain electric activity mapping transit head bioelectrical activity into marked
intuitionistic image, it becomes an advanced, no wound technical instrument for skull sickness,
qualitative analysis for head enginery. Characters for this equipment are as follows:
 Help to bulge and recognize EEG partial features.
 Recognize the subtle features which was easy to be ignored ago.
 Help to academic communication, especially for the amateurs.
 Evaluate the unusual conditions in the traditional EEG and the unexplained situations by eye
measure.

Chapter 2 The main technical index


1. Channels: 16 lead EEG, 19 lead ECG, 32 lead EEG or user-defined lead EEG
2. The normal working condition

a) The range of environment temperature 5℃~40℃

b) Relative humidity range:≤85%

c) Voltage:USB DC 5V

d) Atmospheric pressure range:700hPa~1060hPa


3. Calibration voltage: sinusoidal signal 5mm / 50μV; error: ± 5%
4. Scan speed: 30mm / s ± 5%

5. Noise level: ≤ 5μV

6. Common-mode rejection ratio: ≥ 90dB

7. Instrument's largest energy-consuming ≤ 250VA

8. Baseline drift: ≤ 1mm

9. Input Impedance> 10MΩ

10. 50 Hz interference suppression: ≥ 30 dB

11. Frequency Characteristics: Instrument Input 0.8 Hz ~ 30 Hz, -3 dB, 50μV sinusoidal AC

signal should not be distorted.

12. Resistance to polarization voltage: Add ± 300mV DC polarization voltage deviation is

less than ± 5%

13. Power: 220V ± 22V; 50 Hz ± 1 Hz

14. Fuse: AC 220V; 3A

15.Number of channels: 16-channel EEG

16. Registration Standard Number: Q/QKT01-2007

1
17. Product registration number: Hebei drug possession of firearms (quasi-) character No.

2,210,019, No. 2003

18.Medical Device Manufacturing Enterprise License: Hebei Food Drug Administration

20,050,526 Number of firearms production

19. Transport and storage

a)The range of Environment temperature:-40℃~55℃

b)Relative Humidity range:≤90%

c)Atmospheric pressure range:86kPa~106kPa

20. Product Safety Type: II Class BF-based Application Part

This operation manual is used for KT88series digital brain electric activity mapping. Because of
the different setup in every series of machines, this manual is accordance to the largest
configuration.

This operation manual is used for KT88-3200 series digital brain electric activity mapping.
Because of the different setup in every series of machines, this manual is accordance to the largest
configuration.

Chapter 3 Technical device


CPU:Pentium, more than 4 2.0G(Dual Core Processor if have the function of video )
EMS memory:more than 512M(more than 1G DDR2 if have the function of video)
Mainboard:Support USB2.0,Recommend to use Intel chipset motherboard
Hard drive:More than 80G
Display card:More than 64M
Printer:600dpi Laser printers
Screen: >17 Inch
CD-ROM:More than 24X CD-ROM(or choose CD-ROM system)
Operation System:Microsoft Windows 2000/XP(Recommended Windows XP)
resolution ratio:More than 1024*768
Color:More than 24 colors
Font: Natural
interface:USB2.0
Those intercalate can changed in Windows operating system Display Properties, if you have
doubt in change the system configuration, please refer to Windows operating system to get help.

2
Chapter 4 Software and Hardware setup Wizard
Software Setup Wizard:
First of all, put the KT883200 CD-ROM into drive, and then function the KT883200
Setup.exe. The following will pop-up the dialog box "Welcome to the KT883200 Setup Wizard"

chart 1
To continue, click next, if you would like to select a different folder, click Browse. Click
“continue” 3 times

3
ch
ar
t
2

ch
ar
t
3

chart 4
There will be shown "ready to install", click to install, pop-up "finish install wizard
KT883200", the installation is complete.

4
ch
ar
t
5

chart 6

Chart 7
Select language
and video and then c
lick the button of
"OK" to enter the
KT883200 system.

Uninstalling the
software:
Method 1.
Click "Start" menu in the
"All Programs" to find the installation package to install KT883200, click the following iconto
uninstall the software.
Method 2.
Find KT883200's installation directory (usually installed by default under the C drive), open the
installation directory to find and double-click the icon below to unload

5
Hardware Wizard:
(1)Amplifier and Flash lamp
After installing the software, Link the EEG amplifier and the USB of computer main frame, then
the computer will be prompted to find a new hardware:

chart 8
Choose the third one:”no not this time”, click to next to continue, then will show a Notice, click to
continue.

ch
ar
t
9

6
chart 10
There will be shown “Completing the Wizard”, click “Finish”.
NOTICE :
after click "finish",the computer will be prompted to find a new hardware again. And you
can setup the hardware according to the steps above again. The hardware will finish the
setup when setup is complete.

chart 11
(2) Video (Optional Function)
(1)Link the video class and one of USB port in computer , then the computer will setup the
driver automatically.
(2}Please the softdog inset into one of USB port in computer, the softdog`s driver will be setup
as same as the ampliter`s driver.

Electrode Wizard:
1 The placement of electrode
This system use silver chloridize channel electrode, drip in brine liquor at 5% at work.. Wash
down with clean water after using and airing everyday. Cover it to avoid exposal to protect the
chlorination on electrode.

7
2 Method of electrode placement
10 ~ 20 international standards Electrodes
Nowadays, Placement method become internationally accepted methods , It is simple,
reasonable, clear anatomical landmark, while its electrode spacing equivalent, symmetry, and easy
to compare and placement.

8
All
the
name
of
the
poles
are:
FP1,
FP2,
F3,
F4,
C3,
C4,
P3,
P4,

O1,
O2,
F7,
F8,
T7,
T8, P7, P8;(标准 16 导)
Fz, Pz, Cz, PG1, PG2, AFz, FCz, CPz,
CP3, CP4, FC3, FC4, TP7, TP8, FT7, FT8(附加 16 导)
The pole location on the head shows int the follow picture:

9
3.Connection lead
At least two electrodes for EEG was recorded, an electrode linking with the first gate of ECG
equipment, another one in second gate, Between the two electrode potential difference recorded
EEG was formed.
The electrode Placed in scalp is named active electrode or detection electrodes, the electrode
Placed in ear or zero potential is named unrelated electrode or reference electrode. EEG leads have
2ways: one is unrelated electrode unipolar leads method, another way is only use the bipolar lead
of the activity electrode to instead of the unrelated electrode.
(1) Unipolar lead (Reference lead): The activity of the scalp electrodes and unrelated to the
ipsilateral electrode is linked; Its depiction of the EEG recorded activity for the electrode and
unrelated to the potential difference between electrodes.
(2) Bipolar lead: It’s the way of described and record two Active electrode in scalp and the two
gate in ECG is linked to instead of use unrelated to the electrod.

10
Picture of Connecting Flashlight

Picture of Connecting Amplifier

Picture of Actual Connecting appearance


Place the electrode according to international system electrode emplacement.

Chapter 5 The system operation


Turn on the Brain.exe and enter to the map below.

11
Picture 1
Click the “ New Patient”; the physician input the parameters according to the patients’ condition.
The name item could input English or Chinese. Press “Ctrl+ Space” in keyboard would switch into
Chinese input mode, and then input Chinese name. The physician can choose the acquired method
(Roll View or Movie View) by mouse’s arrowhead. Click “Gather” and enter the picture 3.

12
Picture 2
The physician can choose the gather mode(16 montages or 19montages or 32 montages or User-
defined), Click “OK” and enter the picture 4.

13
Picture 3
The video setup
Click “OK” and enter video setup(as picture 4). The physician can set up the quality, differentiate
rate and other parameters of acquired picture.

14
Picture
4
The

acquisition control panel


In the acquisition interface, the left is the acquired wave to display the patient’s EEG at real time
and the right is the acquisition control pannel to display various of premiums events and control
the acquired methods.

15
Picture 5

The acquisition control panel


In the acquisition interface, the left is the acquired wave to display the patient’s EEG at real time
and the right is the acquisition control panel to display various of premiums events and control the
acquired methods.
Click button, the physician
could chose acquired velocity
in practice.
Click button, the physician could
adjust the plus of EEG in practice.
Click button, the “frequency disturb”
would get rid of AC work frequency disturb which is recommended to use for batter images.

16
Click button,the physician could chose
the Band stop filter of EEG in practice.LBD would light if one of them was in bad connection.
Click button to choose acquisition
method according to practical use.
Click button , the physician could
chose reference electrode at will
when gather EEG according to
practice.

Picture 6
Click “end” to stop EEG acquisition.

17
Picture 7
This interface is for user to replay EEG in sequence.
button is used to display 32-channel EEG in same screen.
button is used to display 16-channel EEG in same screen..
button is used to display 8- channel EEG in same screen.
Physicians can be where it is needed to add tag information, specifically as follows:
Click the toolbar button, click left mouse button where you want to add a tag, pop-up shown in
picture Picture 8 window, the corresponding location displays the flag icon .

18
Picture 8

The
physician can
choose a
segment of
EEG to
analyze. The
method is as
follow:
remove the
mouse to the
beginning,
click the left
button inside the time rectangle, you can see a small red triangle, then select the end of the EEG
with the right button of the mouse in the same way. so as to choose the EEG segment.
The chosen EEG
segment turns into
white. Remove the
mouse to EEG, Click the
right key of the mouse, and
appear items. Move
mouse to “Display Speed”,
it changes to , The physician
could chose display speed in
practice. Move mouse to “display Amp”, it changes to the physician could chose display plus in
practice. Move mouse to “Auto Play”, and then the physician can choose to play EEG actually.

If you want to cancel the segment of EEG, you can just click buttont. Finally, Click
button to dispose the chosen EEG segment to FFT exchange and insert value operation.
After the data disposal is over, the EEG is to be analyzed. Click button enter menus as follows:
This menu is to observe power chart distributing map. Click left button of mouse on any power
chart map could magnify this special lead power chart map.

19
Picture 9 Power Spectrum Graph
Click button as follows:
The left of this menu is to display the patient’s EEG, and the right is
the look down relief map.
button is used to switch in the absolute relief map and
comparative relief map.

20
Picture 10 BEAM

Click button as picture11:

Picture 11
The physician
can design
compressed
chart map
according to
menu tips:

After the
design is over,

21
Click “OK” button as picture 12:

This menu is used to display compressed chart map of any two lead of the patient.
X means frequency , the unit is Hz.
Y means power, the unit is µ v2 /Hz.
Z means dimension of the compressed chart map , it can be decided by the physician

Picture 12 Compressed Spectrum Graph


Click button , and enter the picture 13.
The left of this menu is the patient’s EEG. The right is the patient’s 1—30Hz relief map.
Click button to exchange absolute EEG relief map and comparative EEG relief map.

22
Picture 13 Monochromatic View BEAM
Click button , and enter the picture 14.

The right of the menu is the patient’s three-dimension stereoscopic EEG.


Press every EEG and turn it, which is easy for the physician to definite it.
Click to exchange absolute EEG and comparative EEG.

23
Picture 14 Three--dimensional rotary BEAM
Click button and enter picture 15.
Click button to observe the patient’s side-view EEG from left or right.
Click button to exchange absolute EEG and comparative EEG.
This menu is the patient’s side-view EEG.

24
25
Picture 15 Side View BEAM
Click button and enter the picture 16.This menu is Numerical BEAM.
This menu is patient’s power chart distributing map.

Picture 16 Numerical BEAM


Click button to switch to power chart map. Click any lead , you could magnify it.

26
Picture 17 Spectrum Rectangle Graph
Click button and enter the picture 18.
The physician could divide frequency segment according to this menu. Click “OK”
button to save and return or “Cancel” button to cancel and return after partition.

Picture
18
Click
button
after
return
and enter
picture
19.

27
Picture 19
In this menu, the physician can choose the channel method.(monochannel or double-channel).
After the choice, Click “yes” and display the accordant EEG.
Lead setting instruction: click right of the mouse to customize the any lead from 3 to 9 lead (t
he first two are default leads which can not be modified), click the left of the mouse to drag any le
ad out of the channel list box, and this operation finishes the delete of one lead. If you need to add
lead only by using the mouse to click any two electrodes in the dialog box to complete a operation
of add Settings, click the button of "ok" after finish 32 leads setting. The next time you check lead
s, the setting will show to you.

Click button and enter the picture 20.

28
Picture 20
In this
menu, the
physician
can design
filter
according to
the patient’s
EEG to
clear EEG’s
disturbance
and false
balance.
Click “OK”
button and
appear EEG
which has being filtered.

Play
Click button in the toolbar would play EEG from beginning to end automatically, and
button in the toolbar to stop play.(picture 21)

29
Picture 21

Double click the left of mouse in the EEG waveform area, dialog box will
appear as shown in the figure 4-19, and select the any one of the three red l
ine in the dialog, after that drag the mouse and the gain of waveform, period
and frequency will be changed.

30
Picture 22

In "under control" menu select "the system Settings" menu items, as shown in figure, 23 dialog
box will appear.

Picture 23
As the menu on the left side:
(1)Select" infromation setting", you can edit the information of hospital.( as shown figure 23);
(2)Select"parameter setting", you can set the parameters in the process of waveform replay.

31
( as shown figure 24).
(3)Select "color setting", you can set color of background the induced event and so on.( as
shown figure 25);
The operation of this function is following:
Click the left of the mouse to the button for color after the color change in advance.
(4)Select" event add setting", the user can add the event himself , name it and select color ( as
shown in figure4-26).
The operation is following:
Click the left of mouse to the edit fram after "name" and input the name of the
adding event, click the color button below, click the "add" button to finish the
adding of the user-defined induced event; if you need to delete the induced event,
you can select the induced event item with the left of the mouse and click "delete"
button, in this way the delete is completed.
Click" default setting", all the information will be defaulted and show in this window. Click
"definite" to save it and if you open the case again, all the information is the same as the defaulted
information.( each time you set the parameters, and it will come into effect the next time you
open it).

Picture 24

32
Picture 25

33
Picture 26
Click ,you will come into the figure 27video replay control panel will appear on the
right side of the replay graph. The doctor can control replay in this panel. "play" will
make the waveform show from beginning to end consequently and "stop" will make it stop. Under
the situation of no play, beginning and ending are those of EEG, and "increase degree" and
"decrease degree" is the gain which can adjust the EEG.

Picture 27
Click to come into the calibrate interface which only used for manufacture's checking.

Click,the report will be print out,shown in picture 28。

34
Picture 28

You can choose the different model of printing in the " printing model" of the "printing out"
menu. You can also choose the "model editor" to edit the report model and save it.

Graph printing :

According to picture 5,pictures 7-15, user can print out the graph according to the need.
The operation is following : in the any interface of picture 5,pictures 7-15,clickand
the menu 29will appear ,and then click “definite”,you can print out the topographic map
and EEG graph.
As show in the figure 29, you can set the printing area range and you can input the number
of the first page and the last page, if you want the current page, set the range to 1-1.

35
Picture 29

Select patients :

Click “Select patient” in the menu as picture 1 and enter picture 30.

36
Picture 30
As shown in the figure of 30, click any one case with one click of the left mouse, the
information of the patient will be shown in the right side of the column; if there are many cases
you need to choose, you can also do conditional fast search to find the case you need.

The operation is following:


Select the "select search" with the left of mouse,click the left of mouse to select in the small rect
angular box before screening case conditions, input condition content and click the "search" . T
he content that accords with the case condition will be displayed in the list on the left,and for th
ose cases do not meet the conditions of the case, the system will point out, Click the "clear up",
the content of the user input will be delect.

by clicking the left of mouse to select cases, and clicking the "open" button ( or double click
cases), you can enter the cases of patient according to the figure of4-5. The rest operation is the

37
same to that of the "new patient".

Patient list management :

Click “Patient list management” in the menu and enter picture 31.

Picture 31
As shown in the menu of figure 4-31, you can choose cases(You can also make use of the
function of research to find the case you need.), and modify it (them) in the right side of the
column. After that , click "save" and the prompt will appear, and you click "yes", you can save the
modified case. You can also delete the cases, click and select the number of the case you need to
delete, and them click "delete", you delete the case.

Data format conversion:

38
As shown in the figure 4-1, click " data format conversion", you can come into the figure 32.
With the tools of format conversion, you can transform the case into EDF、ASCII form in order
to data or academic exchange.
Click the button of "Data Type" to select the product model and click "Browse"Button to find
the cases file path (* eeg) on the second line left side, click the button "Data Transform" to begin
the data format conversion, if the conversion is successfully, the system will offer prompt.

Picture 32
Segment saving:
Open the patient case to examine, physician can choose a segment of given
waveform to save according to the requirement. And the steps are as follows:
below the last one lead waveform of the beginning place of the waveform segment selected ,click
the left key of mouse , and there will be the red triangle sign "". Correspondingly , at the end of
the waveform.,click the right key of mouse ,and you will pitch on a segment of waveform. As
shown in the figure4-1, you select " save segment" in the menu, the figure 33 will appear.

input the name of the segment,


Pict click " OK" to save it. If you
ure 33 need to view the old cases, you
can choose one case with left of
the mouse, click the "segment:"
shown in the figure 30 and
prompt of the segment selection
according to the figure 34.select
the segment and open the
waveform.

39
Picture 34
Event list :
Click the press in the tool column, and come into the event list as shown in the
figure35, you can find the name of the induced events and time of those events happen
with the mouse or the up/down
P arrow to select the event, and click
the right forward arrow to switch
icture 35 into the waveform of the induced
event.
Multilingu
al
interface :

In the Chinese
interface,
choose
"system
control" - > "Language Select" - > "English" switch to English interface state ;if System is in
English interface state, choose the "System Configure" - > "Language the Select ->"Chinese"
switch the system to Chinese interface state. The same operation ia also applicable to other
languages.

Exits :
Choose the item of "Exit" in the manu of "Case Management" or click on top right
corner of the menu to exit from KT88 analytical system of digital network EEG
topography.

Chapter 6 Notice

The notice for installation


 Don’t hang anything on the power wire and be treaded by people.
 The machine needs good ground cable. The electric resistance isn’t more than 4 . don’t use
the heat pipe or water pipe as the temporary ground cable.
 All the holes at the back of the machine should not be covered. Otherwise, the machine will
be damaged because it’s too heat.
The notice for application
 The power voltage and frequency should be 220V and 50Hz.
 Don’t cover anything on the holes at the back of the machine.
 Don’t put the machine in a humid environment. When cleaning the machine, please take the
plug away from the socket. Don’t use the liquid cleaner or the alcohol to wash it. Please use
the wet cloth to wipe it. When the machine meets thunderstorm or it stays for a long time,

40
make sure that the plug is taken away from the socket.
 The cables should be used in a correct way.
 In the cold winter, make the machine heat in advance and then use: in the hot summer, don’t
turn on the machine for a long time. For example, when the temperature in the room is over
35℃, the machine should be turned off after used for over 2 hours, and then turn it on again.
 In the process of waveform collection by using apparatus, please don't keep the screen savers
setup being on in order to avoid affecting waveform collection. At the same time , in the
process of waveform collection , don't run other program or course, and pay attention to keep
float windows such as the input methods window hiding.
The notice for protection
 Don’t open the machine without authorization. The machine should be opened by the
experienced technicians.
 Please take the plug away from the socket when meeting the following conditions:
 The power wire and the plug are broken.
 Something drops into the machine.
 The machine can’t work.

Maintenance and troubleshooting


Problem Cause Correction
The power light isn’t light. 1. The power plug isn’t put in Put the power plug in the
the socket. socket.
2. The power isn’t connected Connect the power wire with
with the mainframe, or they’re the mainframe tightly.
not connected well.
3. The power is broken. Connect with the Technical
department of Contec Medical
Systems Co., Ltd
The display light isn’t light. 1. The display plug isn’t Connect the display plug with
connected with the mainframe. the mainframe.
2. The power of the display Turn on the power of the
isn’t turned on. display.
The display’s light is light but 1.The display’s wire isn’t Connect the display’s wire
no display. connected with the mainframe. with the mainframe.
2.The light-control button is Adjust the light-control button.
turned to the darkest.
3.The display is broken. Connect with the technical
department of Contec Medical
Systems Co., Ltd
The display’s light isn’t light The display is broken. Connect with the technical
and no display. department of Contec Medical
Systems Co., Ltd
The printer isn’t printed. Read the related part of the
operation manual.

41
The print’s color is too light or The ink is used up. Change another new ink.
not clear.
The printer doesn’t work. 1.The print line isn’t Connect the print line tightly.
connected.
2.The print line is broken. Change another new print line.
3.The procedure of the print is Turn off the computer, and
wrong. then turn on the printer, and
the computer.
EEG is disturbed a lot. 1.The ground cable isn’t Place the ground cable in a
connected well. standard way.
2.The electrode is corroded. Change the new electrode.
3.The cramp of the cable is Change the new cable.
corroded.
4.The cable is broken. Change the new cable.
5.The hair is too dirty. Wash the hair.
One part is disturbed a lot. The electrode of that place Wear the electrode again.
isn’t connected well.
Some channel is disturbed a The electrode of that place Wear the electrode again.
lot. isn’t connected well.

Appendix
The principle of EEG relief map
EEG relief map is a new method to analyze head bioelectricity in accordance with computer
technology and computer picture disposal technology. As a new method around the world right
now , it transforms huge complex but abnormity head bioelectricity to a form which could reflex
quantitative change and orientation by computer. It displays complexion about diversification of
head energy, it becomes an excellence , no wound and scientific method for skull sickness
diagnose and research on head energy quantitative analysis. It is useful to analysis correctly on
head energy using this technology .
Principle and method:
Placement of electrodes: lay 16 lead on outboard head according to international 10/20 system
method standard, collect head wave signals and make A/D (modules transform) transform.
F-transform:
Transform the collected head wave signals to power chart map form to display the relationship
about head wave frequency flied and power.
Frequency assort:
δfrequency flied: 0.8~3.8Hz
θ frequency flied: 4.0~7.8Hz
α1 frequency flied: 8.0~9.8Hz
α2 frequency flied: 10.0~12.8Hz
β1 frequency flied: 13.0~19.8Hz

42
β2 frequency flied: 20.0~29.8Hz

Insert value operation:


Find out some insert function according to two-dimension insert inside value principle based on
these known sixteen number, calculate 2500 point numbers.

Print:
Print the received data to module picture and get power relief picture.

Usual relief map:


Some power of δ wave relief map higher than regular value at 8 level and those exceed would
belong to abnormities.
Some power of θwave relief map exceed normal value at 10 level local or whole head belong to
abnormities.
Evident un-symmetry of αwave relief map about the distributing of the two hemispheres. Those
exceed 3 or 5 belong to abnormities.

Power chart relief map of patient:


Most of the patient’s relief map would be abnormity and main of those are power exceed of δwave
and θwave, especially evident in the forward of head. Followed by the increase of the power of
α2wave (namelyαwave) and the power of βwave also has trend to increase.

43