GENERAL:
2. In applications where heat transfer from process to RTD is slow and sheath is to
be installed in direct contact with the process; standard dwg.S35.406.current
revision refers.
3. When use of protective thermowells are not practical, such as elements used
for pipe surface temperature sensing; standard dwg.S35.411.current revision
refers. (Figure.2)
ENVIRONMENT:
DESCRIPTION.
For:
DIMENSIONS:
The sheath shall have a nominal outside diameter of 6.0mm ? 0.1mm. Length of
element measured from the sheath tip to the flange shall be specified in the purchase
order. Standard dwg.S35.409.current revision refers.
MATERIALS:
PERFORMANCE:
The resistance tolerances shall comply with class A or B according to IEC 751 as
specified in the purchase order.
Class A tolerance (ºC) 0.15 +0.002[t]
Class B tolerance (ºC) 0.3 +0.005[t]
[t] = modulus of temperature in degrees celsius without regard to sign.
If tolerance is not specified class B tolerance shall apply.
The insulation resistance of the compacted ceramic material shall have a minimum
resistance of 100Me at ambient temperature (15-35ºC ?5) and a relative humidity of
minimum 80%, with an applied 10 to 100 V. DC voltage in accordance with IEC 751.
Any decrease in insulation resistance at elevated temperatures shall be in accordance
with IEC 751.
IDENTIFICATION:
FACTORY TESTING:
WITNESS INSPECTION:
CERTIFICATION:
All items shall be clean and free from all foreign matter prior to packing.
REFERENCES:
American Standards.
Industrial platinum resistance thermometers. ASTM E1137
German Standards.
Stop flanges for TC and RTD thermometers. DIN 43734
sensor units for resistance thermometers. DIN 43762
International Standards.
Temperature, humidity and barometric pressure. IEC 654-1
industrial platinum resistance thermometer sensors. IEC 751
Standard Drawings.
Thermocouple assembly for stirring kettle. S35-406
thermometer assemblies in thermowells. S35-409
thermometer assembly surface mounting. S35-411