Client- M/s HESTER BIOSCIENCES AFRICA LIMITED DCPL INTERNATIONAL

Project- VACCINES PRODUCTION FACILITY


Project No.- 544

SUMMARY SHEET FOR CRP WORK

S.R. DESCRIPTION AMT IN USD $

1 CLEAN ROOM PANEL WORK 213,914.43

TOTAL AMOUNT 213,914.43

TOTAL AMOUNT IN MIO $ 0.21


BILL OF QUANTITY FOR CLEAN ROOM PANEL
PROJECT:- HESTER BIOSCIENCES AFRICA LTD.
Release For -TENDER Date : 10.08.18

PROJECT NO:- 544 544/AR/BQ/CRP/R-0 Version No.:V0.2

Based On Drawing No
CONSULTANTS:- DCPL INTERNATIONAL
HBL/544/01/AR(LYT)-111
BOQ of Clean Room Panel Work For Hester Biosciences Africa Ltd. (+/-10 %)
S.No. Item Description

POULTRY
BUILDING DISCRIPTION VACCINE LOWEST PROPOSED RATE
ANTIGEN

Unit Qty. RATE AMOUNT REMARKS


Note:- All rates should be quoted including QRO itmes.
CLEAN ROOM PANEL & ACCESSORIES:
Modular Wall Panels / Ceiling Panels (infill Rockwool)

1 (PCGI+PCGI:PCGI sheet Both Side) Double skin Polyester coated Mettalic Clean
Room Wall Panels (Thickness - 80/100 mm) with infill material as Rockwool
Sandwitched between panel along with all associated required fittings supportings
material & making cutouts & conduits for fixing all kind of provision like Switch Sq. M. 600 63.95 38,370
Boards, Manometers, Sleeves,Magnehaulic guage etc. by providing required
openings etc. complete.

2 (PCGI+PCGI:PCGI sheet Both Side) Double skin Polyester coated Mettalic Clean
Room Panels (Thickness - 50 mm) with infill material as Rockwool Sandwitched
between panel along with all associated required fittings supportings material &
making cutouts & conduits for fixing all kind of provision like Switch Boards, Sq. M. 0
Manometers, Sleeves,Magnehaulic guage etc. by providing required openings etc.
complete.

3 (PCGI+PCGI: PCGI sheet Both Side) Cladding with Double skin(Thickness 50


mm) to brick wall / R.C.C. columns with all associated accessories with infill Sq. M. 0
Rockwool.
4 (SS+PCGI: One side SS sheet & other side PCGI sheet) Double skin Clean
Room Wall Panels (Thickness - 80/100 mm) with infill material as Rockwool
Sandwitched between panel along with all associated required fittings supportings
material & making provision for fixing all kind of provision like Switch Boards, Sq. M. 0
Manometers, Sleeves, Magnehaulic guage etc. by providing required sizes of
cutouts /openings etc. complete.

5 (SS+PCGI: One side SS sheet & other side PCGI. Sheet) SS Cladding with
Double skin(Thickness 50 mm) to brick wall / R.C.C. columns with all associated Sq. M. 0
accessories with infill Rockwool.
6 (PCGI+PCGI:PCGI sheet Both Side-CEILING PANELS) Load bearing walk on
clean room double skin ceiling(Thickness - 80 mm) with Rockwool infill material
sandwitched between the panels including making provision for HVAC SA/RA,
electrical light fixtures, sleeves utilities (Pendants, Sleeves) etc. by providing Sq. M. 450 66.00 29,700
required sizes of cutout/opening etc. complete. The load bering capacity should
not be less than 150 kg/sq mtr

7 (PCGI+PCGI: PCGI sheet Both Side-CEILING PANELS) Non walkable clean


room Double skin ceiling 50 mm thick with Rockwool infill material sandwitched
between the panels including making provision for HVAC SA/RA, electrical light Sq. M. 0
fixtures, sleeves utilities (Pendants, Sleeves) etc. by providing required sizes of
cutout/opening etc. complete.
8 (SS+PCGI: One side SS sheet & other side PCGI Sheet-CEILING PANELS) Load
bearing walk on clean room double skin ceiling(Thickness - 80 mm) with
Rockwool infill material sandwitched between the panels including making
provision for HVAC SA/RA, electrical light fixtures, sleeves utilities (Pendants, Sq. M. 0
Sleeves) etc. by providing required sizes of cutout/opening etc. complete. The
load bering capacity should not be less than 150 kg/sq mtr

Return Air (RA) Riser Duct Panels:


9 Providing GI powder coated Return Air Riser Ducts with removable grill of size
750x450 mm for 900x80/100 size and height in as per F/C LVL. (Above the celling
up to 200mm )The 200 mm box above riser should be provided with MS angle Nos. 34 275.00 9,350
iron / GI flange and with matching flange bolted with suitable GI nut bolts

10 Providing GI powder coated Return Air Riser Ducts with removable grill of size
600x450 mm for 750x80/100 size and height in as per F/C LVL. (Above the celling
up to 200mm )The extended flange of 200 mm should be provided with MS angle Nos. 6 231.80 1,391
iron flange/ suitable GI flange and matching flange bolted with suitable GI nut bolts

11 Providing GI powder coated Return Air Riser Ducts with removable grill of size
450x450 mm for 600x80/100 size and height in as per F/C LVL. (Above the celling
up to 200mm )The extended flange of 200 mm should be provided with MS angle Nos. 17 187.59 3,189
iron flange/ suitable GI flange and matching flange bolted with suitable GI nut bolts

12 Providing GI powder coated Return Air Riser Ducts with removable grill of size
300x450 mm for 450x80/100 size and height in as per F/C LVL. (Above the celling
up to 200mm )The extended flange of 200 mm should be provided with MS angle Nos. 3 143.74 431
iron flange/ suitable GI flange and matching flange bolted with suitable GI nut bolts

Doors/Windows/View Panels in CRP Work 0


Flush Double door (D0)2000X2100mm (Clear opening) including SS hinges &
13 flush view panel 450x750 mm flush to partition wall panels including required Nos. 725.00 0
ironmongry and automatic door closer.(TS-73 -Dorma or eq.)
Flush Double door (D0)1800X2100mm (Clear opening) including SS hinges &
14 flush view panel 450x750 mm flush to partition wall panels including required Nos. 0
ironmongry and automatic door closer.(TS-73 -Dorma or eq.)
Flush Double door (D1)1500X2100mm (Clear opening) including SS hinges &
15 flush view panel 450x750 mm flush to partition wall panels including required Nos. 30 259.56 7,787
ironmongry and automatic door closer.(TS-73 -Dorma or eq.)
Flush Double door (D1SS)1500X2100mm (Clear opening) for wash area
including SS hinges & flush view panel 450x750 mm flush to partition wall panels
16 including required ironmongery and automatic door closer.(TS-73 Dorma or eq.) Nos. 0
(With SS sheet one side & PCGI sheet up to full height on other.)

Flush Single door (D2) 1200X2100mm (Clear opening) including SS hinges &
17 flush view panel 450x750 mm flush to partition wall panels & including required Nos. 5 207.64 1,038
ironmongery and automatic door closer.(TS-73 -Dorma or eq.)

2
BILL OF QUANTITY FOR CLEAN ROOM PANEL
PROJECT:- HESTER BIOSCIENCES AFRICA LTD.
Release For -TENDER Date : 10.08.18

PROJECT NO:- 544 544/AR/BQ/CRP/R-0 Version No.:V0.2

Based On Drawing No
CONSULTANTS:- DCPL INTERNATIONAL
HBL/544/01/AR(LYT)-111
BOQ of Clean Room Panel Work For Hester Biosciences Africa Ltd. (+/-10 %)
S.No. Item Description

Flush Single door (D3)900X2100mm (Clear opening) including SS hinges & flush
18 view panel 450x750 mm flush to partition wall panels including required Nos. 34 155.74 5,295
ironmongery and automatic door closer.(TS-73/TS-68 Dorma or eq.)
Flush Single door (D4)750X2100mm (Clear opening) including SS hinges & flush
view panel 350x750 mm flush to partition wall panels with frosted glass including
19 required ironmongery and automatic door closer.(TS-68 Dorma or eq.) Nos. 0

Emergency door (ED1) 1500X2100mm (Clear opening) including SS hinges &


20 flush view panel 450x750 mm flush to partition wall panels including required Nos. 1 259.56 260
ironmongery and panic bar.
Emergency door (ED3) 900X2100mm (Clear opening) including SS hinges & flush
view panel 450x750 mm flush to partition wall panels including required Nos. 0
ironmongery and panic bar.
Flush View Panel units (VP) in modular partition. 600 x 1100 mm made out of
5mmx2(Thickness) toughened glass with all necessary arrangements.(80-100 mm
21 thick),should be provided with Silica gel arrangement to absorb the moisture. Nos. 0

Flush View Panel units (VP1) in modular partition. 900 x 1100 mm made out of
6mmx2(Thickness) toughened glass with all necessary arrangements.(80-100 mm
22
thick),should be provided with Silica gel arrangement to absorb the moisture.
Nos. 26 79.84 2,076

Flush View Panel units (VP1FH) in modular partition. 900 x 1800 mm made out of
6mmx2(Thickness) toughened glass with all necessary arrangements.(80-100 mm
23 thick),should be provided with Silica gel arrangement to absorb the moisture. Nos. 0

Flush View Panel units (VP2) in modular partition. 1800 x 1100 mm made out of
24 6mmx2(Thickness) toughened glass with all necessary arrangements.(80-100 mm Nos. 3 159.65 479
thick)
Flush View Panel units (VP2FH) in modular partition. 1800 x 1800 mm made out of
6mmx2(Thickness) toughened glass with all necessary arrangements.(80-100 mm
25 thick),should be provided with Silica gel arrangement to absorb the moisture. Nos. 0

Emergency break glass Flush View Panel (ED1-BR) in modular partition. 1500 x
26 2000 mm made out of 6mm(Thickness) toughened glass with all necessary Nos. 12 300.00 3,600
arrangements.

Flush External Window View Panel units W in CRP / External Panel (integrated)
with wall clading partition of size 1200x1100 mm made out of 6mmx2(Thickness)
27 toughened glass with all necessary arrangements. As per site, should be provided Nos. 0
with Silica gel arrangement to absorb the moisture.

Flush External Window View Panel units W in CRP / External Panel (integrated)
with wall clading partition of size 1500x1100 mm made out of 6mmx2(Thickness)
28 toughened glass with all necessary arrangements. As per site, should be provided Nos. 0
with Silica gel arrangement to absorb the moisture.

Coving:

3
BILL OF QUANTITY FOR CLEAN ROOM PANEL
PROJECT:- HESTER BIOSCIENCES AFRICA LTD.
Release For -TENDER Date : 10.08.18

PROJECT NO:- 544 544/AR/BQ/CRP/R-0 Version No.:V0.2

Based On Drawing No
CONSULTANTS:- DCPL INTERNATIONAL
HBL/544/01/AR(LYT)-111
BOQ of Clean Room Panel Work For Hester Biosciences Africa Ltd. (+/-10 %)
S.No. Item Description

29 The Aluminium coving of required radius/size shall be fixed on Aluminium frame


work of angle and flats. The required jointing fixtures like 2D/3D shall be fixed at
required locations. Corners caps should be fixed at all corners. The coving shall Rmt. 0
be wall to wall and wall to ceiling. The workmanship as regards line, level and
plumb should be of high standard.
(a) Wall to ceilling Rmt. 800 5.37 4,296
(b) Wall to wall Rmt. 550 5.37 2,954
(c) Wall to floor 0
30 The PVC coving of required radius/size shall be fixed on Aluminium frame work of
angle and flats. The required jointing fixtures like 2D/3D shall be fixed at required
locations. Corners caps should be fixed at all corners. The coving shall be wall to Rmt. 0
wall/wall to ceiling . The workmanship as regards line, level and plumb should be
of high standard.
(a) Wall to ceilling Rmt. 0
(b) Wall to wall Rmt. 0
31 Floor coving of required radius & size in Epoxy Rmt. 0
a) Wall to floor Rmt. 840 0
0
Cutouts for HEPA If required. Extra afterwards
32a H-1- (600x600) mm Nos 25 Inclusive
32b H-2-(600x600) mm Nos 13 Inclusive
32c H-3-(300x300) mm Nos 8 Inclusive

Cutouts for Air diffuser - 4 way type ( Cutouts ) Extra afterwards

33a SD / RD - 1-(600x600) mm RO Inclusive


33b SD / RD - 2-(450x450) mm RO Inclusive
33c SD / RD - 3-(300x300) mm RO Inclusive

Air diffuser - swirl type ( Cutouts ) Extra afterwards


34a SD / RD - 1-(600x600) mm Nos 19 Inclusive
34b SD / RD - 3-(450x450) mm Nos 13 Inclusive
34c SD / RD - 4-(300x300) mm RO 18 Inclusive

Lights ( Cutouts ) Extra afterwards


35a Cutouts (600 x 600 mm) Nos 118 Inclusive
35b Cutouts (300 x 300 mm) Nos 40 Inclusive
35c Cutouts (600 x 300 mm) FLP Nos Inclusive
36 Utility cutouts (for pendant & pipes) Nos Inclusive
37 Electrical Modular switch boards Nos Included Inclusive
38 Electrical Industrial Socket Outlets Nos Included Inclusive
39 Providing & fixing 50mm dia SS 304 pipe for guard rail Rmt. 82 68.00 5,576
STATIC PASS BOX

40a 1000 x 1000 Nos


40b 900 X 900 Nos
40c 600 X 600 Nos 0
40d 450 X 450 Nos 0
DYNAMIC PASS BOX

41a 1800 x 1800 Nos


41b 1200 x 1500
41C 1200 x 1200 Nos 0
41d 1000 x 1000 Nos 3 3,259.35 9,778
41e 900 X 900 Nos
41f 1500 x 1500 Nos 0
41g 600 x 600 Nos 1 2,068.94 2,069
41h 450 x 500 Nos
TOTAL
COST IN 127,638
USD
ADD EXTRA AS APPLICABLE : -
1 INSTALLATION CHARGES OF BASIC VALUE 40000
ADD TRANSPORTATION CHARGES from Ex-factory to Dar ES
45000
2
Salaam Port

3 PACKING CHARGES INCLUDED

1% 1276
4 TRANSIT INSURANCE from Ex-factory to Dar ES Salaam Port

GRAND TOTAL IN USD 213,914

NOTE:

4
Globion India Pvt. Ltd. Doshi Consultants (P) Ltd.

Project:- Globion India Pvt. Ltd. BILL OF QUANTITY FOR Chapter No.:
Project N o.:-- 298. CLEAN ROOM PANEL (R & D LAB)
Consultant:- Doshi Consultants Pvt. Version No.: 00
Ltd. Release for :- TENDER
Drawing No. : - 3/298/GLOBION/R&D/AR-121 (R-7) Date: 08.02.2008.

"BOQ" of Clean Room Panel Work at M/s Globion India Pvt. Ltd. (R & D Lab), at Karakapatla Village.

S.No. Item Description Qty. Unit Rate Amount

Note:- 1) All rates should be quoted including QRO itmes.

CLEAN ROOM PANEL & ACCESSORIES:

Modular Wall Panels / Ceiling Panels :

1 a) Double skin modular Clean Room Panels (Thickness - 80-100 mm)


with Rockwool bonded (38 kg/cu.m. density) / PUF Sandwitched
between panel along with all associated necessary fittings,
QRO Sq. M. 3,450.00
supporting materials, all kind of cutout/opening provisions like
Switch Boards, Manometers, Sleeves, etc.

1 b) Double skin modular Clean Room Panels (Thickness - 40-50 mm) with
Rockwool bonded (38 kg/cu.m. density) / PUF Sandwitched between
panel along with all associated necessary fittings, supporting
180 Sq. M. 3,150.00 567000
materials, all kind of cutout/opening provisions like Switch Boards,
Manometers, Sleeves, etc.

2 Single skin cladding (Thickness 40-50 mm) to brick wall / R.C.C.


columns with all associated accessories. 95 Sq. M. 2,750.00 261250

3 Load bearing walk on ceiling Panels (Thickness - 80-100 mm) with


Rockwool bonded (150 kg/cu.m. density) / PUF Sandwitched between
panel along with all associated necessary fittings, supporting
materials, all kind of cutout/opening provisions for HVAC (Supply QRO Sq. M. 3,750.00
Air, RA Risers), Electricals (Light Fixtures, Sleeves), Utilities
(Pendants, Sleeves) etc.

3 a) Single Skin False Ceiling Panels (40 to 50 mm thick) fixed on R.C.C.


slab / Beam, including all kind of cutout/opening provisions for
HVAC (Supply Air, RA Risers), Electricals (Light Fixtures, Sleeves), 175 Sq. M. 2,900.00 507500
Utilities (Pendants, Sleeves) etc.

0
Return Air (RA) Riser Duct Panels: 0
4 Flush riser duct panels & coupling to main HVAC ducting. (RA1-
750x150mm) - Single Wall Panel QRO Nos. 14,500.00

5 Flush riser duct panels & coupling to main HVAC ducting. (RA2-
600x150mm) - Single Wall Panel QRO Nos. 14,500.00

Page 5
Globion India Pvt. Ltd. Doshi Consultants (P) Ltd.

Project:- Globion India Pvt. Ltd. BILL OF QUANTITY FOR Chapter No.:
Project N o.:-- 298. CLEAN ROOM PANEL (R & D LAB)
Consultant:- Doshi Consultants Pvt. Version No.: 00
Ltd. Release for :- TENDER
Drawing No. : - 3/298/GLOBION/R&D/AR-121 (R-7) Date: 08.02.2008.

"BOQ" of Clean Room Panel Work at M/s Globion India Pvt. Ltd. (R & D Lab), at Karakapatla Village.

S.No. Item Description Qty. Unit Rate Amount

6 Flush riser duct panels & coupling to main HVAC ducting. (RA3-
450x150mm) - Single Wall Panel QRO Nos. 14,500.00

7 Flush riser duct panels & coupling to main HVAC ducting. (RA4-
300x150mm) - Single Wall Panel QRO Nos. 14,500.00

Page 6
Globion India Pvt. Ltd. Doshi Consultants (P) Ltd.

Project:- Globion India Pvt. Ltd. BILL OF QUANTITY FOR Chapter No.:
Project N o.:-- 298. CLEAN ROOM PANEL (R & D LAB)
Consultant:- Doshi Consultants Pvt. Version No.: 00
Ltd. Release for :- TENDER
Drawing No. : - 3/298/GLOBION/R&D/AR-121 (R-7) Date: 08.02.2008.

"BOQ" of Clean Room Panel Work at M/s Globion India Pvt. Ltd. (R & D Lab), at Karakapatla Village.

S.No. Item Description Qty. Unit Rate Amount

Doors/Windows/View Panels: 0
8 Flush Double door (D1) with required ironmongry* & flush view
panels 1500x2100mm (Flush to partition wall Panels) 2 Nos. 34,500.00 69000

9 Flush Single door (D2) with required ironmongry* & flush view panel
1200x2100mm (Flush to partition wall Panels) QRO Nos. 28,500.00

10 Flush Single door (D3) with required ironmongry* & flush view panel
900x2100mm (Flush to partition wall panels) 17 Nos. 22,000.00 374000

11 Flush Single door (D4) with required ironmongry* & flush view panel
750x2100mm (Flush to partition wall panels) QRO Nos. 19,500.00

12 Emergency door (ED) with required ironmongry* & flush view panel
1500X2100mm (Flush to partition wall panels) QRO Nos. 45,500.00

13 Flush ViewPanel units in modular partition. 1200 x 1200 mm made


out of 6mmx2(Thickness) toughened glasss with all necessary 7 Nos. 7,500.00 52500
arrangements.

Coving:
14 Aluminum Coving (walls to wall) 135 Rmt. 425.00 57375
15 Aluminum Coving (walls to ceilling) 195 Rmt. 425.00 82875

TOTAL COST IN RS. 1971500

Page 7
BILL OF QUANTITY FOR CLEAN ROOM PANEL
PROJECT:- HESTER BIOSCIENCES AFRICA LTD. Release For -TENDER Date : 28.03.2018
544/AR/BQ/CRP/R-0 Version No.:V0.2
Based On Drawing No:
PROJECT NO:- 544 HBL/544/01/AR(LYT)-111

CONSULTANTS:- DCPL INTERNATIONAL Technical Specifications of Clean Room Panel


CLEAN ROOM PANEL & ACCESSORIES (METAL)

Sr. Item Description DCPL RECOMMENDED SPECIFICATIONS MAKE VENDOR'S OFFERED SPECIFICATIONS
No.

1 Wall/Ceiling Panels
Galvanized Sheet of 120 GSM with polyster
a) G.I. Panel/ CRCA powder coated / CRCA
b) Stainless Steel (in Wash area) SS 304 panel
2 Panel Thickness

80/100 mm thick sandwitch panel properly


a) Wall Panels framed all around (Vendor to specify)

b) Wall/ Cladding panels 50 mm thick -do as above


c) Load Bearing Walk on Ceiling 50 /80 mm thick -do as above
d) Non load Bearing Ceiling 50 mm thick panel -do as above

1.0 mm thk. For partition & ceiling with


3 Sheet Thickness Rockwool Infill

4 Coating of Sheet Polyster Powder coated


5 Infill Material of Panels (Partitions) Rockwool 96 Kg/M3
6 Infill Material of Panels (Ceiling) Rockwool 144 Kg/M3

7 Gap in two panel Should be 4 mm maximum and uniform joint


8 Service temperature range -30 to + 250 deg cent.
9 Chemical resistance Resistance to Acid, Alkali & Detergent
10 Solvent Resistance Resistance to MEK-50, IPA-40 , Ethyl Alcohol
11 Tensile stress 75 to 90 KPA
Permissible Compressive stress at 5%
12 compression 45 to 50 KPA

13 Built in cutout for HVAC / Light Fitting Strengthened around cut outs & covered with
sheet so that no material (infill) to be exposed.

14 Return air riser system Inbuilt riser in the panel with perforated Return
Air SS Grill as per size provided.

Vendor should submit the detailed drawing for


15 Vendors working drawing in detail approval with elevations for wall and panels

16 Return air riser depth vendor to confirm


17 Return air riser width 350 mm to 950 mm
Partition vendor will extend riser height 200
18 Riser height mm above the topside of the ceiling for duct
connection.

Perforated SS Grill (sheet) with or without


prefilter should flush with riser surface. Vendor
19 Return air grill in riser will submit the fixing arrangement for return air
perforated sheet.

Partition vendor shall provide 25/30 mm flange


20 End connection of return air riser to air duct to the riser with 8mm dia. hole at Interval of
150 mm
21 Sound Insulation 55dB
22 Glass 5 / 6 mm Toughned / plain Float Glass
23 Bonding of Glass 3 M double Adhesive 1.20 mm thick Tape 1/2"
width
24 Panel Size
a) Panel Width 1000 mm to 1500 mm / 1220 mm
2400/2700/3000/3100/3500/4500/ 6000 mm
b) Panel Height length of Single Panel

SS 304 Frame inside, both side flush with 6.00


25 View Panel mm Toughend glass, Powder Coated Frame

Flush doors with the same material of panel/


26 Door Type/Accessories 1.2 mm thick CRCA sheet frame and shutter
thickness 0.8/1.0 mm.

a)Dorma make, Clean room compatible (TS-73)


27 Door closer make and material with hold open arm, b) (TS-68) with standard
arm.

28 Door closer withstand to air pressure Differential pressure – 30 to 35 mm WG


BILL OF QUANTITY FOR CLEAN ROOM PANEL
PROJECT:- HESTER BIOSCIENCES AFRICA LTD. Release For -TENDER Date : 28.03.2018
544/AR/BQ/CRP/R-0 Version No.:V0.2
Based On Drawing No:
PROJECT NO:- 544 HBL/544/01/AR(LYT)-111

CONSULTANTS:- DCPL INTERNATIONAL Technical Specifications of Clean Room Panel


CLEAN ROOM PANEL & ACCESSORIES (METAL)

Sr. Item Description DCPL RECOMMENDED SPECIFICATIONS MAKE VENDOR'S OFFERED SPECIFICATIONS
No.
29 Door hinges SS 304, ball bearing , minium3 Nos per shutter
30 Door bottom seal type Movable drop seal
31 Door seal material Non particle sheding
32 Gasket type in-between door frame and leaf Rubber gasket EPDM non-particle sheding type.
33 Flush tower bolts in double door SS 304 concealed extended lever
1.2 mm thick SS - 304 , Ht. 400 mm along with
34 Kick plate door width both sides.
35 Data Sheet Vendor should fill the data sheet
36 Fire Rating Rating as per standard BT 476 Part 22/20

Directly self-supporting on panels or hanged


from true ceiling/suspended from ceiling /
37 Support System of Ceiling suspended from ceiling grid system. (All
suspender, Truss or Support structure included
in ceiling support system).

For installation & maintenance of


38 Service Panel conduits/pipes,etc. Pilaster panel and
demountable panel wherever required

39 Load bearing capacity of walkable ceiling 150/200 Kg / m2


40 Grid Vendor to specify
41 Ceiling Support Should be included in offer
To filled flush and neatly FDA approved food
42 Sealant included in offer for panel and grade silicone sealant - GE/ Dowcorning or
ceiling
equivalent

To be made within panels as per sample fitting


Provision for switch / socket & magnehalic and flush with the face of panel at proper height
43 gauge/light/filter etc and location shown in the drawings, including
provision of conduits/ pipe or sleeves required
for service to be casted within panel.

Ceiling panels should have provisions for light


fixtures, HEPA & diffusers support. Cut outs
44 Cut Outs should be done at factory or site and include
covering of all infill materials as per the sample
fitting.

45 Note: Vendor to provide and confirm along with offer all above.