Sie sind auf Seite 1von 2

PUNCHING SHEAR CHECK

Dia of Pile = 900 mm


Maximum Load on Pile = 768.6 KN ( Load case - 78 Pile - P18)
( From Staad analysis - Strength case )
Check for Punching Shear Near Pile
Z
Mz d/2

MY
Y Y
a2

Z
a1
( Pile top End force & Moments are considered for two way shear check )

Critical Section for punching shear at a distance d/2 from the face of column
d/2 = 195 mm
Width of critical section for shear ,a1 = 1290 mm
Width of critical section for shear ,a2 = 1290 mm
Periphery of critical
section for shear, b0 = 4052.65 mm
Effective depth of Base slab d = 390 mm
Maximum Pile End forces
Compression = 768.6 KN
Moment, My = -20.388 KN.m
Moment, Mz = 141.137 KN.m
Ultimate Punching Shear, Vu = 768.6 KN

Fraction ,  = ( As per Cl. 31.3.3 - IS456:2000)

Width of critical section for shear ,a1


In Direction Moment (My) acts = 1290 mm

Width of critical section for shear ,a1


In Direction Moment (Mz) acts = 1290 mm
Fraction ,  = 0.6
Moment transferd by eccentricity of shear
about centroid of critical section , My shear = ( 1- x My
= -8.16 KN.m
Mz shear = 84.68 KN.m
polar moment of inertia of the critical section
about YY & ZZ (Axis about which the moment acts),
Jxx =

C1+d = a1 ( for Rectagle / Square)


C2+d = a2 ( From SP24- 1983)

= d x a13 / 6 + d x a13 / 6 + d x a1 x a22 / 2


= 390 x1290^3 / 6 + 390 x1290^3 / 6 +390 x1290^2 x1290 / 2
Jyy & Jzz = 6.97674E+11 mm4

Punching Shear v =

= Vu / b0d + My shear a1 / 2xJyy + Mz shear a2 / 2xJzz


= 0.55703 N/mm2
Permissible shear stress c = 0.16fck
= 0.87636 N/mm2
HENCE OK