Sie sind auf Seite 1von 79

To Know Hisense GLOBAL NETWORK

Hisense Group, headquartered in eastern China, is an international conglomerate founded in 1969 mainly
focusing on white goods and electronics. In the past several years, Hisense has held the record of being
the 3rd most popular TV brand worldwide and the 2nd most popular VRF brand in China respectively. Over
decades, we’ve dedicated ourselves to the technological innovation, quality assurance and integrated
service delivery. In the upcoming 2019, with the collaboration of R&D centers, branch offices and service
centers all around the world, Hisense VRF firmly hold confidence in providing excellent user experience
and service to our values clients globally.

INDUSTRIAL MODULES

Real Estate TV and Display Devices


High-end Plaza Chains Internet TV Operation
Mould Design and Manufacturing Mobile Communication Devices
Business Optical Communication Devices
Finance Chip

Real Estate and Multimedia


Modern Services

SPORTS MARKETING

IT Smart Systems Household Appliances

Smart City Refrigerator


Smart Community Freezer
Smart Transportation Air-conditioner
Smart Business Washing Machine
Medical Electronic Devices Kitchen Appliance
Smart Home System and Service
HIGH-EFFICIENCY AND ENERGY-SAVING

What is Hisense VRF


Hisense VRF is produced by Qingdao Hisense Hitachi Air-conditioning Systems Co., Ltd., jointly invested
by Hisense Group and Hitachi Air Conditioning(changed to Johnson Hitachi in 2015) for air-conditioning
manufacturing, technology development, marketing and service.
The strict quality control system is the trustworthy guarantee of Hisense VRF. From designing,
manufacturing to testing, Hisense VRF insists on abiding by the highest standard to keep high quality.

Computer Simulation Development---The Most Advanced and Energy Saving Development Mode
Excellence-led Manufacture Mode---Efficiency and Energy Saving
Strict Quality Control and Component Test---High Quality, High Efficiency and Low Energy Consumption

KEY FEATURES AND BENEFITS


003 High Efficiency
008 High Reliability
012 Best Comfort
017 More Flexibility Design
019 More Flexibility Installation and Maintenance

PRODUCT LINE
025 Outdoor Unit
CONTROL SYSTEM
Why Choose
027 Hi-FLEXi S Series
043 Hi-FLEXi G+ Series 124 Wired Controller
057 Hi-FLEXi X Series 127 Wireless Controller

Hisense VRF?
065 Hi-FLEXi R Series 127 Receiver Kit for Wireless Control-optional
075 Hi-FLEXi W Series Heat Recovery 128 Centralized Controller
083 Hi-Smart H Series 131 Building Management System
089 Air to Water Heat Pump
089 Hi-AquaSmart Series
093 MULTI-FUNCTION Series

OPTIONAL PARTS
High Technology and Outstanding Operation Performance 099 Indoor Unit
Comprehensive Product Lineup 113 ​Ventilation Solution​
Modular Combination Design Gives Greater Flexibility
More Space Saving​ 137 Support
Easier Transportation and Installation 141 Optional Parts
Intelligent Control System
Key Features
and Benefits
High Efficiency
High Reliability
Best Comfort
More Flexibility Design
More Flexibility Installation and Maintenance
03/04
HIGH EFFICIENCY
Key Features and Benefits

New Generation of Enhanced Vapor Injection Scroll Compressor


Anti-overcompression Technique
Hisense Hi-FLEXi S Series adopts a new generation of the high efficiency scroll compressor and the patented vapor
injection technology*1. It can greatly enhance the heating performance and achieve high energy-saving efficiency.
Powerful heating is guaranteed by Hi-FLEXi S Series, especially under low temperature with heating performance
increased up to 25%, compared with the standard model. Hisense high pressure chamber scroll compressor adopts
patented Release Valve Technique, which effectively
Note:*1. Patent number: a heat exchange cycle system and control methods and air conditioning, 201610909006.X
prevents the overcompression when compressor is
in partial load operation and drastically promotes the
intermediate pressure performance.
New Suction Structure
Increase efficiency at high speed and stability under large capacity.
○Orbiting Scroll Lifting Force Optimization is improved
Release Valve
Increase efficiency by reducing compression loss especially for medium and low capacity ○Leakage Loss Reduction
conditions. ○Improved Intermediate Pressure Performance

Injection Valve
Heating performance improvement under partial load conditions by injection valve.

New Scroll Shape


High efficiency by asymmetric scroll shape.
Compliant Frame Mechanism
High performance technology by reduce leakage loss and friction loss.
Featured Discharge System
High reliability due to minimum oil loss at any condtion due to refrigerant flow out The Latest Dual FOC 180° Sine Wave DC Variable
from center of compressor.
Oil Equalization Mechanism Speed Drive Technology
Capacity can be enlarged by plural compressors and oil balance between plural
compressors.
High Efficiency Motor
High efficiency by rare earth magnet and special designed motor. The inverter adopts double FOC 180° vector sine wave drive algorithm to drive the compressor motor in dual mode, and
Oil Seperation possesses various protective functions against over current, over voltage, under voltage, short circuit, modules and heat
High reliability by keeping oil in the compressor by this separation plate. sinks temperatures, power phase loss, bus voltage fluctuations and communication failures to ensure the efficiency and
High Reliability Oil Supply System reliability.
Oil supply system using pressure difference without any problem even at low speed or
partial load condition.
PVE Oil
Using PVE oil ensuring a high reliable and long life.
30° 120° 60° Current

120°
120°

Exclusive Asymmetric Scroll Square Wave

Time Voltage

The asymmetric scroll structure effectively reduces refrigerant gas leakage during suction and compression and
Conventional Control Mode
enhances operation efficiency and reliability.

Inside Chamber Pi=Ps


Achieve Suction Current
180°
180°

Square Wave

Voltage
Time

Reduce Suction Loss


and Leakage Loss 180° Sine Wave DC Inverter-Driven Technique
Outside Chamber Po>Pi
During Compression
High Efficiency
05/06
HIGH EFFICIENCY
Key Features and Benefits

Precise Capacity-output Control Stepped Fins


The inverter technique combined with elaborate control algorithm ensures responsive capacity-output adjustment based
on real-time indoor load, which reduces temperature fluctuation and provides coziness.
Previous fins The latest developed fins

Load% Load%

Capacity Output Capacity Output


Indoor Load Indoor Load

Φ9.53
Φ7.0
Overlapping section Overlapping section
surface of fins surface of fins

Wind direction Wind direction


Hisense Precise Inverter Control Time(h) Conventional Inverter Control Time(h) Thick Thin

Hierarchical diagram of hydrophilic aluminum foil

Stepless Fan-speed Control


Lubricating layer
● Not easy to frost in heating mode;
Hydrophilic coating ● Slow down the corrosion of heat exchanger by corrosive gases;
● Destroying the surface tension of water droplets accelerates the
Corrosion-resistant coating down flow speed of defrost water or condensate water and
improves the air conditioning performance.
The BLDC motor equipped in outdoor unit can realize stepless fan-speed adjustment to ensure system efficiency and Fin
stability.

Stepless

Improvement of Heat Transfer Reduction of Air Flow Resistance

Air Streamline Grille

Heat Transfer Coefficient

Air Flow Resistance


The stability of discharge pressure and suction pressure of compressor is assured
The stability of flow (capacity) dynamic allocation of indoor unit is assured
Efficient Axial Fan Quick response of control system is improved, accordingly the system stability,
durability and reliability are assured

Face Velocity Amount of Frost


07/08
HIGH EFFICIENCY HIGH RELIABILITY
Key Features and Benefits

Optimized Refrigerant Circuit Patented 360° Fitted Refrigerant Cooling


Technology, More Reliable Cooling System
The heat-exchange efficiency is substantially increased due to the specially designed refrigerant flow structure.

Gas Phase Liquid Phase Gas Phase Liquid Phase


With the patented 360° refrigerant cooling
technology, heat will be removed from the
main PCB. It can help to improve the electrical
Increase the liquid
reliability when it is running under high ambient
refrigerant volume temperature. This can effectively prevent poor
proportion
heat dissipation and ensure stability and safety
under cooling mode.

Conventional 2-in-1 Refrigerant Flow Path

Hi-FLEXi S Series Hi-FLEXi W Series


Common Refrigerant Circuit Optimized Refrigerant Circuit

Gas Liquid Gas Liquid


Oil Return
Refrigerant Refrigerant Refrigerant Refrigerant

The accumulator adopts porous oil return technology with a built-in fine strainer, which not only ensures oil balance
between compressors within one module, but also plays an important role in the oil balance between modules.
Gas Liquid Gas
Liquid
Refrigerant Refrigerant Refrigerant
Gas phase

Liquid phase

Gas phase

Liquid phase
Refrigerant
Gas-liquid Gas-liquid
mixed phase mixed phase
Gas Liquid Gas
Refrigerant Refrigerant Refrigerant

Outdoor unit 1 Outdoor unit 2


Increase the proportion of liquid refrigerant in the heat
exchanger to improve heat transfer efficiency

Two-stage Subcooling
A subcooling section is designed in the heat exchanger of outdoor unit to realize the first-stage subcooling. Furthermore,
Accumulator
a high efficient double pipe is applied to achieve the second-stage subcooling. The total subcooling degree is up to 27℃ ,
which improves cooling capacity and increases the total piping length.
Oil Return
Compressor Operation
Two-Stage Super-Cooling Cycle Diagram Two-Stage Super-Cooling Pressure Enthalpy Diagram Frequency
Except for this, the system implements oil-return
operation based on compressor frequency and
First Stage of
Super-cooling corresponding operation time. The oil-return High
operation takes 60 seconds, and can return to
previous operation state when it’s done. Time
Second Stage of
Super-cooling The Increased Cooling
Heat Exchanger Capacity in Super-cooling
Cycle
Sub-cooler Super-cooling Section
In winter under heating mode, this operation is t
implemented without changing to cooling, which Low T
○The two-stage super-cooling cycle improves cooling capacity;
○The pressure loss of the refrigerant flow in the pipe is reduced guarantees heating effect. t
○The increased super-cooling degree promotes the stable operation
of the electronic expansion valve;
○The increased super-cooling degree increases the total piping length.
Cooling Capacity
09/10
HIGH RELIABILITY
Key Features and Benefits

Oil Separation Rotational Operation


Regulating the operation time of each outdoor unit leads to load reduction on compressors, thus, outdoor unit endurance
First-stage oil separation is realized through efficient During second-stage oil separation, the small is improved.
oil separation structure inside high-pressure-chamber amount of oil discharged from compressor is
compressor. Only a small amount of oil is brought out of separated by a large-capacity, high-efficiency
the compressor. centrifugal oil separator, with efficiency over 99%.

A B C D A B C D
100h 101h 102h 103h 104h 101h 102h 103h
ON OFF OFF OFF OFF ON OFF OFF

A B C D B C D A

Rotational Operation

A B C D A B C D
First-stage oil separation Second-stage oil separation 104h 105h 106h 103h 104h 105h 102h 103h
OFF OFF OFF ON OFF OFF ON OFF

D A B C C D A B

Oil Balance Double Back-up Function

Through adjusting the amount of discharge oil and return oil in the compressor, accumulator and oil separator, In single module system, one compressor can start to operate when another fails. In module combination, one outdoor
oil balance is perfectly achieved without oil balance pipe. This can avoid fluctuations of system pressure and unit can start to operate when another fails. Double back-up function ensures reliability and stability of Hisense VRF
temperature to ensure stability, and simplify the construction work. system.

Standby Operating Failed


Status Status Status

Liquid pipe

Gas pipe Without oil


balance pipe Compressor Backup Outdoor Unit Backup
11/12
HIGH RELIABILITY BEST COMFORT
Key Features and Benefits

Anti-corrosion Refrigerant Temperature Control

Hisense refrigerant temperature control can provide best comfort for users. The evaporating temperature value can
The anti-corrosion treated outdoor units have been be adjusted either automatically according to indoor load in a certain range or manually according to the application
designed to provide corrosion resistance against acid environment.
rain and salt corrosion.

Features:
1.Evaporating temperature can be adjusted between 2°C to 16°C
Fan Protection which is the widest on the market.
2.Rapidly cooling depends on the lower evaporating temperature.
Convention 3.Preventing cold draft bases on the higher evaporating temperatures.
4.Save energy by increasing seasonal efficiency.

Instantaneous reverse
rotation with sudden
increased torque may
cause damage to the
blades

External forces make the fan

Precise Temperature Control


Counter-rotate

Fan Protection Function


Multiple thermal probes in indoor unit to provide 2000-step electronic expansion valve to ensure
precise real-time temperature feedback. precise flow adjustment based on the actual load of
Indoor Unit.

Unique Design
outlet air temperature sensor

External forces make the fan The fan stops before the Forward rotation with small starting
torque, protect fan blades 2000-step Electronic Expansion Valve
Counter-rotate unit starts

Condensed Water Leakage Protection Conventional


Temperature Control
Too Hot
Precisely judge indoor temperature:
Float switch is a standard part in Hisense indoor unit. To protect the ceiling from getting wet or soaked, the float switch
(1)Air return temperature. sensor Most Comfortable
will work to stop indoor unit when condensed water can’t be drained in time because of blockage of drain pump or drain ±0.5
Comfortable
pump breakdown. (2)temperature. sensor on Wired remote controller
(3)Based on the average value.
Operating Condensed Water Warning Stop Too Cold Hisense
Setting temperature.
Suitable for irregularly Temperature Control

shaped room
13/14
BEST COMFORT
Key Features and Benefits

Rapid Heating Start-up Outdoor Unit Noise Control

Night Mute Control


Combing the soft start of DC inverter compressor and rapid start of fixed speed compressor, the system can
achieve 100% heating capacity output instantly to meet the air conditioning demand. Night-shift function is equipped to reduce the noise by up to 15 dB.

HP
Load Change Curve
90 seconds rapid start-up
Peak Temperature
100% Capacity Output

Temperature Change Curve

Common Models
Noise Change Curce

Hisense Hi-FLEXi S Series

0 90seconds 5min Time


*Taking 66HP as an example Low Noise Mode
The user can flexibly select the noise reduction
value according to the actual requirement and
meet the ability requirements. In addition, the
Intelligent Defrosting Mode operation period of low noise mode can be
determined by external input (Signal input).

The outdoor unit adopts 3 sensors to precisely grasp the defrosting opportunity. Also, it has an anti-frost structure at the
bottom, both of which reduces the amount of frost to only 1/3 compared to ordinary defrosting mode.

Hisense optimal defrost mode


Defrosting VIP Mode
Heating operation Heating operation

Hisense outdoor units have VIP mode setting function. Under this mode, the system will satisfy the cooling need of the
Little frost Still not much frost Little frost Still not much frost
VIP room firstly.

Heating operation Heating operation Heating Heating operation Heating operation


operation

Traditional defrosting mode


Heating operation Heating operation Heating operation Heating operation Heating operation
Anti-frost Structure

Note: this function is an optional function. It can be set according to the actual requirement ( a system can set max.5 indoor units as VIP ) . Under the
severe operating condition, other indoor units' capacity may be influenced when customers use this function.
15/16
BEST COMFORT
Key Features and Benefits

Demand Mode
Automatically Adjust Setting Temperature
The intelligent demand mode can adjust the air conditioning operation automatically according to peak-valley requirements With Motion Sensor, the indoor unit will automatically adjust the setting temperature according to the indoor heat source
of electricity. It achieves balance between comfort and energy-saving while meeting the power demand for daily work. load. The indoor unit will be turned off automatically when no people in room. The sensor also comes with draft functions
to direct the air blowing people or avoiding people.

When the power consumption value exceeds


the set range, it will be restricted
Power Saving 20%-60%
Power Consumption

Setting Power

Greater efficiency within the set range

Normal Operating Cost Demand Mode


Daily running time
Operating Cost

More Health
Morning Night

Duct Adapter
More Reasonable Air Distribution In order to satisfy the fresh air intake function, the Duct Adapter as the optional part
equips at the mini 4-way cassette type and 4-way cassette type.

Unser-friendly Air Supply Mode and Louvers Control Independently Humidity Sensor
a. The unit has the breeze mode that provides miniature draft through the holes at the four flat corners.
Humidity Sensor has the automatic dehumidification function that will create comfortable
b. The 4 air louvers can be controlled independently and 4 air speed adjustment are available to meet various indoor environment for users. Humidity Sensor possesses the low temperature
requirement. dehumidification function.

Environmental Protection Fresh Air Introduction


Hisense VRF adopts reliable eco-friendly refrigerant R410A, Hisense VRF system can introduce outdoor fresh air into
which is non-toxic to human and does not damage the indoor space through fresh air equipment such as all fresh
Earth’s ozone layer. Also, we actively respond to Europe air indoor unit and heat recovery ventilator, which constantly
RoHS directive, controlling the use of hazardous substance supplies fresh air and creates a healthy environment for users.
strictly.

Environment-friendly Refrigerant
17/18
MORE FLEXIBILITY DESIGN
Key Features and Benefits

Summary of Pipe Length Fan Static Pressure Adaptive Technology Making


Installation Space More Flexible
With static pressure adaptive technology, the fan of the outdoor unit can be adjusted in free static pressure based on
Series W system requirements to meet a variety of needs in different environments. The maximam external static pressure of the
Unit S G+ X R heat recovery
Item outdoor unit can be up to 110Pa*, which provides better conditions for the layered installation and centralized installation.
Higher static pressure and further distance of air supply of the outdoor unit ensure the smooth flow of air and solve
condensing problems of the outdoor unit effectively.Enough already been said about the static and flexibility so delete last
Total Piping Length m 1000 1000 1000 1000 500 sentence.

Max. piping Length


m 190(165) 190(165) 190(165) 190(165) 190(165)
Equivalent (actual)
Up to
Height difference
110Pa*
m 30 30 30 30 15
between Indoor Units

Piping Length between 1st


m 90 90 90 90 40
Branch and indoor unit

Outdoor Unit
Height difference m 90* 90* 90* 50 50
is higher Layered installing outdoor units Easy to conceal outdoor unit, Air flow diagram
between outdoor easily dealing with heat dissipation problem. good looking of facades
unit and indoor
unit Outdoor Unit
m 90* 90* 90* 40 40 *Note: By the note corresponding, eternal static pressure of the outdoor unit can be up to 110Pa.
is lower For detailed information, please contact Hisense’s technical staff.

Largest pipe length of pipes


m 10 10 10 10 10
between outdoor units

*Note: For detailed information, please consult the technical staff.


Minimized Floor Space
The large capacity outdoor units achieves the minimized floor space.
Wide Operating Range Meets Greater Demand

With a wide operating temperature range, the outdoor


unit can operate from -25°C WB to 16.5°C WB. The °C WB
heating effect in winter is strong, which perfectly °C WB

meets the customers’ needs in different environments.


The unit is able to operate in -25°C WB ambient, °C WB VS
when the unit is heating mode and also operate at °C WB

52°C WB ambient in cooling mode.


24HP 24HP

previous New previous New


19/20
MORE FLEXIBILITY INSTALLATION AND MAINTENANCE
Key Features and Benefits

Compact and Light-weight Design One-touch Test Run

The one-touch test run can be operated at the outdoor unit side as well as the indoor unit side, which makes it much
easier for commissioning.

ON ON

Easy for transportation


1 2 3 4 5 6 1 2 3 4 5
Cooling mode test run Heating mode test run

Elevator Realizing test run through the Realizing test run through the DIP-switch
controller at the indoor unit side at the outdoor unit side.

7-segment LED on the Outdoor Intelligent Detection

The 7-segment LED on the outdoor unit makes it easy to monitor and check the details about the operating status The specially designed Data collector can automatically detect the systems running condition. With real time monitoring,
such as refrigerant temperature, pressure, compressor frequency, alarm code, etc., which makes both operation system parameters, trouble shooting and preventative maintenance can be managed.
management and maintenance more convenient.

Automatic Detection
Through Computer

Indoor Unit Indoor Unit Indoor Unit

Data Collector H-Assist DeviceOutdoor Unit


21/22
MORE FLEXIBILITY INSTALLATION AND MAINTENANCE
Key Features and Benefits

Easy-to-read Error Automatic Restart

The access hole is designed on the electrical box plate, which makes more convenient and safety checking PSW When power resumes, the AC will has two modes. Mode 1: the AC will re-start, no matter what status the AC is before
button and SEGD without taking down the electrical box plate. power failure. Mode 2: the AC will return to previous setting automatically.

Service Service
Window Window

The system operates normally After power off ( memory storage ) Restore to the previous state when
before power off system stops running the power supply is recovered

Handle
01 02 03
Hi-FLEXi S Series Hi-FLEXi W Series

Automatic Addressing Urgent Power-off Maintenance of Indoor Units


Hisense VRF system can assign indoor unit addresses automatically, It is convenient in the case of large system
with a lot of indoor units. When one indoor unit need maintenance, it can be powered off separately. Also, it does not need any setting on
outdoor, automatically re-regist all indoor unit and have no influence on the whole system.
Product Line

Product
Line
Outdoor Unit
Air to Water Heat Pump
Indoor Unit
​Ventilation Solution​
25/26
OUTDOOR UNIT Product Line

HP 2.5 3 4 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 102 104 106 108 110 112

G+

MULTI-
FUNCTION

Hi-AquaSmart
27/28
OUTDOOR UNIT Product Line

Patented 360°
Hi-FLEXi S Series Fitted Refrigerant Cooling Technology, More Reliable Cooling System

With the patented 360° refrigerant cooling technology, Hi-FLEXi S Series will remove the heat from the main PCB,
inverter module and outdoor unit's electrical box stably and efficiently. It can help to improve the electrical reliability of the
unit when it is running under high ambient. This ensures stability and safety of the outdoor unit running and also prevents
poor heat dissipation caused by the fan cycle rotation or stop mode.

Latest enhanced capacity series:

G-type heat exchanger, more efficient


Enhanced vapor injection scroll compressor with rapid heating performance
Float switch design, ensuring decoration safety
Wide operating range, precise temperature control ◎ The refrigerant heat sink of aluminum alloy with
high thermal conductivity and the internal mechanical
tube can integrate closely to keep the heat transfer
efficiency.

Patent Number:
1.Processing method of refrigerant heat sink, air conditioning and
refrigerant cooling, 201710413663.X
2.Refrigerant heat sink and air conditioning, 201720645923.

New Generation of Enhanced Vapor Injection Scroll Compressor

Hisense Hi-FLEXi S Series adopts a new generation of the high efficiency scroll compressor and the patented vapor
injection technology*1. It can greatly enhance the heating performance and achieve high energy-saving efficiency.
Powerful heating is guaranteed by Hi-FLEXi S Series, especially under low temperature with heating performance ◎ A tin heat conductor is added between the refrigerant pipe and the heat sink built-in the electrical component to
increased up to 25%, compared with the standard model. increase the heat transfer efficiency. Made by imported lead-free solder film with high thermal conductivity, the tin heat
conductor greatly improve the overall performance.
Note:*1. Patent number: a heat exchange cycle system and control methods and air conditioning, 201610909006.X
Patent Number:
3.Testing device and method of a refrigerant heat sink, 201710456157.9
4.Testing device and method for refrigerant heat sink, 201710601662.8

DC Frequency Inverter Technology in Compressor

Load %
Hisense VRF adopts a wide range and high-precision Tube Expander Refrigerant Pipe Heat Sink
Air conditioning capacity output Heat Sink
inverter technology. Its adjustment range is 0-450Hz
Indoor load
and the control accuracy is 0.01Hz. The running speed
of outdoor DC inverter compressor can be adjusted
continuously and freely, which improves the user Heat Conductor

experience and also enhances the energy efficiency of


the unit. Heat Sink Built-in
Electrical Component
Precise Inverter Control Time (h)
29/30
OUTDOOR UNIT Product Line

Powerful Heating Performance Under Low Temperature Extra Long Pipe Enabling The Height Difference Between
Indoor and Outdoor Units up to 90 Meters *
With extra long pipe, the height difference between the indoor unit and outdoor unit is up to 90 meters *, which
The system uses the vapor injection two-stage compressor technology and intelligent defrost technology to achieve makes installation more flexible.
strong heating efficiency which ensures the strong heating performance even under -25℃ .
Maximum length of a single pipe: 190 meters
total length of pipes: 1000 meters

Maximum height difference between largest pipe length of pipes


Snowing Snowing indoor and outdoor units: between outdoor units: 10 meters
the upper face of the outdoor unit is 50m
and the bottom of the outdoor unit is 40m

By the note corresponding:


when the outdoor unit is above:90m*
when the outdoor unit is below:90m*
Maximum length from the first branch
pipe to the farthest indoor unit: 90m

Feel Cold Feel Comfortable Maximum height difference of


indoor units: 30m

Rapid Heating Under Low Temperature


*NOTE: For detailed information, please consult the technical staff.

When the Hi-FLEXi S Series is running at a low outdoor ambient of -15oC, the outlet air temperature of the indoor
unit can reach up to 40oC or higher* in a short time. The outdoor unit has a fast and powerful heating efficiency, so it Fan Static Pressure Adaptive Technology Making
can offer you a warm and comfortable environment in winter. Installation Space More Flexible
With static pressure adaptive technology, the fan of the outdoor unit can be adjusted in free static pressure based on
system requirements to meet a variety of needs in different environments. The maximam external static pressure of the
Heating at -15 C
o

outdoor unit can be up to 110Pa*, which provides better conditions for the layered installation and centralized installation.
This test result is based 50
Higher static pressure and further distance of air supply of the outdoor unit ensure the smooth flow of air and solve
on the 10HP outdoor unit and 2 indoor units condensing problems of the outdoor unit effectively.Enough already been said about the static and flexibility so delete last
40 sentence.
Test conditions:
Outdoor suction temperature: -15oC(dry bulb),
30
Relative humidity:75%,
Indoor unit suction temperature:20oC(dry bulb), high air volume.
Length of indoor and outdoor pipes: 6 meters. 20
Measurement sites: laboratory of constant temperature.
Time (Mins)
10
Note: The actual heat time depends on the heat load, models and building structure.
0 5 10 15 20 25 30 35

Hisense Hi-FLEXi S Series Common models Layered installing outdoor units Easy to conceal outdoor unit, Air flow diagram
easily dealing with heat dissipation problem. good looking of facades
*Note: By the note corresponding, eternal static pressure of the outdoor unit can be up to 110Pa.
For detailed information, please contact Hisense’s technical staff.
31/32
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

Hi-FLEXi S Series HP 8HP 10HP 12HP 14HP 16HP 18HP Hi-FLEXi S Series HP 20HP 22HP 24HP 26HP 28HP

Model AVWT-76HKSS AVWT-96HKSS AVWT-114HKSS AVWT-136HKSS AVWT-154HKSS AVWT-170HKSS Model AVWT-190HKSS AVWT-212HKSS AVWT-232HKSS AVWT-250HKSS AVWT-272HKSS

Combination — — — — — — Combination — — — — —

Power Supply 380-415V 3N~ 50Hz / 60Hz Power Supply 380-415V 3N~ 50Hz / 60Hz
Rated Capacity kW 22.4 28.0 33.5 40.0 45.0 50.0 Rated Capacity kW 56.0 61.5 68.0 72.5 80.0
Cooling Operation*1 Power Consumption kW 5.21 7.00 8.65 10.53 12.50 15.63 Cooling Operation*1 Power Consumption kW 17.90 20.50 22.82 24.58 27.59
EER 4.30 4.00 3.87 3.80 3.60 3.20 EER 3.13 3.00 2.98 2.95 2.90
Rated Capacity kW 25.0 31.5 37.5 45.0 50.0 56.0 Rated Capacity kW 63.0 69.0 75.0 80.0 90.0
Heating Operation*1 Power Consumption kW 5.77 7.59 9.21 11.72 13.70 16.97 Heating Operation*1 Power Consumption kW 19.87 22.48 24.59 26.67 30.41
COP 4.33 4.15 4.07 3.84 3.65 3.30 COP 3.17 3.07 3.05 3.00 2.96
Air Flow Rate m³/min 183 183 183 200 200 200 Air Flow Rate m³/min 267 296 296 350 350
Noise level*2 dB(A) 59 60 62 62 62 62 Noise level*2 dB(A) 63 64 66 67 67
Cabinet Color*3 Grayish White Cabinet Color*3 Grayish White
Compressor Type Enhanced Vapor Injection Compressor Compressor Type Enhanced Vapor Injection Compressor
Refrigerant Type R410A Refrigerant Type R410A
Gas Line mm Φ19.05 Φ22.20 Φ25.40 Φ25.40 Φ28.60 Φ28.60 Gas Line mm Φ28.60 Φ28.60 Φ28.60 Φ31.75 Φ31.75
Liquid Line mm Φ9.53 Φ9.53 Φ12.70 Φ12.70 Φ12.70 Φ15.88 Liquid Line mm Φ15.88 Φ15.88 Φ15.88 Φ19.05 Φ19.05
H mm 1730 1730 1730 1730 1730 1730 H mm 1730 1730 1730 1730 1730
Out Dimension W mm 950 950 950 1210 1210 1210 Out Dimension W mm 1350 1350 1350 1600 1600
D mm 750 750 750 750 750 750 D mm 750 750 750 750 750
H mm 1930 1930 1930 1930 1930 1930 H mm 1930 1930 1930 1930 1930
Packing Dimension W mm 1015 1015 1015 1275 1275 1275 Packing Dimension W mm 1420 1420 1420 1665 1665
D mm 790 790 790 790 790 790 D mm 790 790 790 790 790
Max.number of connectable IDU 13 16 19 23 26 29 Max.number of connectable IDU 33 36 40 43 47
Max. Fuse Current A 25 32 32 40 40 50 Max. Fuse Current A 63 63 63 80 80
Max. Running Current A 17.2 22.5 23.5 28.6 33 38.6 Max. Running Current A 44.5 49.8 52.4 56.9 58.2
Net Weight kg 224 244 245 297 298 347 Net Weight kg 361 369 370 414 415
Gross Weight kg 243 263 265 321 322 371 Gross Weight kg 395 396 397 446 447
Connection Ratio 50% - 150% Connection Ratio 50% - 150%
Compressor Quantity PC 1 1 1 1 1 2 Compressor Quantity PC 2 2 2 2 2
Condenser Fan Quantity PC 1 1 1 2 2 2 Condenser Fan Quantity PC 2 2 2 2 2
Height Difference Between ODUs is Higher Than IDUs m 50 (90*4) Height Difference Between ODUs is Higher Than IDUs m 50 (90*4)
ODUs and IDUs ODUs is Lower Than IDUs m 40 (90*4) ODUs and IDUs ODUs is Lower Than IDUs m 40 (90*4)
Height Difference Between IDUs m 30 Height Difference Between IDUs m 30
Cooling DB -5oC~ 52oC*5 Cooling DB -5oC~ 52oC*5
Operation Range Operation Range
Heating WB -25oC*5~ 16.5oC Heating WB -25oC*5~ 16.5oC
Max. Total Piping Length m 1000 Max. Total Piping Length m 1000

Notes: Notes:
1. Rated cooling capacity and rated heating capacity are tested in the following conditions: 1. Rated cooling capacity and rated heating capacity are tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m Cooling conditions: indoor air inlet temperature: 27oC DB 19℃ WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m
Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7℃ DB 6℃ WB, pipe length: 7.5m, pipe height difference : 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene. 2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products. 3.The final appearance of outdoor units is subject to the actual products.
4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer. 4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer.
5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer. 5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer.
33/34
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

Hi-FLEXi S Series HP 30HP 32HP 34HP 36HP 38HP Hi-FLEXi S Series HP 40HP 42HP 44HP 46HP 48HP

Model AVWT-290HKSS AVWT-308HKSS AVWT-324HKSS AVWT-344HKSS AVWT-360HKSS Model AVWT-380HKSS AVWT-402HKSS AVWT-422HKSS AVWT-444HKSS AVWT-464HKSS

Combination AVWT-154HKSS AVWT-154HKSS AVWT-170HKSS AVWT-190HKSS AVWT-190HKSS Combination AVWT-190HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS
AVWT-136HKSS AVWT-154HKSS AVWT-154HKSS AVWT-154HKSS AVWT-170HKSS AVWT-190HKSS AVWT-170HKSS AVWT-190HKSS AVWT-212HKSS AVWT-232HKSS
Power Supply 380-415V 3N~ 50Hz / 60Hz Power Supply 380-415V 3N~ 50Hz / 60Hz
Rated Capacity kW 85.0 90.0 95.0 101.0 106.0 Rated Capacity kW 112.0 118.0 124.0 129.5 136.0
Cooling Operation*1 Power Consumption kW 23.03 25.00 28.13 30.40 33.53 Cooling Operation*1 Power Consumption kW 35.80 38.45 40.72 43.32 45.64
EER 3.69 3.60 3.38 3.32 3.16 EER 3.13 3.07 3.05 2.99 2.98
Rated Capacity kW 95.0 100.0 106.0 113.0 119.0 Rated Capacity kW 126.0 131.0 138.0 144.0 150.0
Heating Operation*1 Power Consumption kW 25.42 27.40 30.67 33.57 36.84 Heating Operation*1 Power Consumption kW 39.74 41.56 44.46 47.07 49.18
COP 3.74 3.65 3.46 3.37 3.23 COP 3.17 3.15 3.10 3.06 3.05
Air Flow Rate m³/min 400 400 400 467 467 Air Flow Rate m³/min 534 496 563 592 592
Noise level*2 dB(A) 67 67 67 67 67 Noise level*2 dB(A) 67 67 68 68 69
Cabinet Color*3 Grayish White Cabinet Color*3 Grayish White
Compressor Type Enhanced Vapor Injection Compressor Compressor Type Enhanced Vapor Injection Compressor
Refrigerant Type R410A Refrigerant Type R410A
Gas Line mm Φ31.75 Φ31.75 Φ38.1 Φ38.1 Φ38.1 Gas Line mm Φ38.1 Φ38.1 Φ38.1 Φ41.3 Φ41.3
Liquid Line mm Φ19.05 Φ19.05 Φ19.05 Φ19.05 Φ19.05 Liquid Line mm Φ19.05 Φ19.05 Φ19.05 Φ22.2 Φ22.2
H mm 1730 1730 1730 1730 1730 H mm 1730 1730 1730 1730 1730
Out Dimension W mm 1210+1210 1210+1210 1210+1210 1210+1350 1210+1350 Out Dimension W mm 1350+1350 1210+1350 1350+1350 1350+1350 1350+1350
D mm 750 750 750 750 750 D mm 750 750 750 750 750
H mm 1930 1930 1930 1930 1930 H mm 1930 1930 1930 1930 1930
Packing Dimension W mm 1275+1275 1275+1275 1275+1275 1275+1420 1275+1420 Packing Dimension W mm 1420+1420 1275+1420 1420+1420 1420+1420 1420+1420
D mm 790 790 790 790 790 D mm 790 790 790 790 790
Max.number of connectable IDU 49 52 55 59 62 Max.number of connectable IDU 64 64 64 64 64
Max. Fuse Current A 80 80 100 100 100 Max. Fuse Current A 125 125 125 125 125
Max. Running Current A 61.6 66 71.6 77.5 83.1 Max. Running Current A 89 91 96.9 102.2 104.8
Net Weight kg 595 596 645 659 708 Net Weight kg 722 717 731 739 740
Gross Weight kg 643 644 693 717 766 Gross Weight kg 790 768 792 793 794
Connection Ratio 50% - 150% Connection Ratio 50% - 150%
Compressor Quantity PC 2 2 3 3 4 Compressor Quantity PC 4 4 4 4 4
Condenser Fan Quantity PC 4 4 4 4 4 Condenser Fan Quantity PC 4 4 4 4 4
Height Difference Between ODUs is Higher Than IDUs m 50 (90*4) Height Difference Between ODUs is Higher Than IDUs m 50 (90*4)
ODUs and IDUs ODUs is Lower Than IDUs m 40 (90*4) ODUs and IDUs ODUs is Lower Than IDUs m 40 (90*4)
Height Difference Between IDUs m 30 Height Difference Between IDUs m 30
Cooling DB -5oC~ 52oC*5 Cooling DB -5oC~ 52oC*5
Operation Range Operation Range
Heating WB -25oC*5~ 16.5oC Heating WB -25oC*5~ 16.5oC
Max. Total Piping Length m 1000 Max. Total Piping Length m 1000

Notes: Notes:
1. Rated cooling capacity and rated heating capacity are tested in the following conditions: 1. Rated cooling capacity and rated heating capacity are tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m
Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene. 2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products. 3.The final appearance of outdoor units is subject to the actual products.
4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer. 4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer.
5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer. 5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer.
35/36
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

Hi-FLEXi S Series HP 50HP 52HP 54HP 56HP Hi-FLEXi S Series HP 58HP 60HP 62HP 64HP

Model AVWT-482HKSS AVWT-504HKSS AVWT-522HKSS AVWT-544HKSS Model AVWT-552HKSS AVWT-570HKSS AVWT-592HKSS AVWT-612HKSS

Combination AVWT-250HKSS AVWT-272HKSS AVWT-272HKSS AVWT-272HKSS AVWT-212HKSS AVWT-190HKSS AVWT-232HKSS AVWT-232HKSS


AVWT-232HKSS AVWT-232HKSS AVWT-250HKSS AVWT-272HKSS Combination AVWT-170HKSS AVWT-190HKSS AVWT-190HKSS AVWT-190HKSS
AVWT-170HKSS AVWT-190HKSS AVWT-170HKSS AVWT-190HKSS
Power Supply 380-415V 3N~ 50Hz / 60Hz
Power Supply 380-415V 3N~ 50Hz / 60Hz
Rated Capacity kW 140.5 148.0 152.5 160.0
*1 Rated Capacity kW 161.5 168.0 174.0 180.0
Cooling Operation Power Consumption kW 47.40 50.41 52.17 55.18
Cooling Operation*1 Power Consumption kW 51.76 53.70 56.35 58.62
EER 2.96 2.94 2.92 2.90
EER 3.12 3.13 3.09 3.07
Rated Capacity kW 155.0 165.0 170.0 180.0
Heating Operation*1 Rated Capacity kW 181.0 189.0 194.0 201.0
Power Consumption kW 51.26 55.00 57.08 60.82
Heating Operation*1 Power Consumption kW 56.42 59.61 61.43 64.33
COP 3.02 3.00 2.98 2.96
COP 3.21 3.17 3.16 3.12
Air Flow Rate m³/min 646 646 700 700
Air Flow Rate m³/min 696 801 763 830
Noise level*2 dB(A) 70 70 70 70
Noise level*2 dB(A) 70 70 70 70
Cabinet Color*3 Grayish White
Cabinet Color*3 Grayish White
Compressor Type Enhanced Vapor Injection Compressor
Compressor Type Enhanced Vapor Injection Compressor
Refrigerant Type R410A
Refrigerant Type R410A
Gas Line mm Φ41.3 Φ41.3 Φ41.3 Φ41.3
Gas Line mm Φ44.5 Φ44.5 Φ44.5 Φ44.5
Liquid Line mm Φ22.2 Φ22.2 Φ22.2 Φ22.2
Liquid Line mm Φ22.2 Φ22.2 Φ22.2 Φ22.2
H mm 1730 1730 1730 1730
Out Dimension H mm 1730 1730 1730 1730
W mm 1350+1600 1350+1600 1600+1600 1600+1600
Out Dimension W mm 1210+1210+1350 1350+1350+1350 1210+1350+1350 1350+1350+1350
D mm 750 750 750 750
D mm 750 750 750 750
H mm 1930 1930 1930 1930
H mm 1930 1930 1930 1930
Packing Dimension W mm 1420+1665 1420+1665 1665+1665 1665+1665
Packing Dimension W mm 1275+1275+1420 1420+1420+1420 1275+1420+1420 1420+1420+1420
D mm 790 790 790 790
D mm 790 790 790 790
Max.number of connectable IDU 64 64 64 64
A Max.number of connectable IDU 64 64 64 64
Max. Fuse Current 160 160 160 160
Max. Fuse Current A 160 160 160 200
Max. Running Current A 109.3 110.6 115.1 116.4
Max. Running Current A 127 133.5 135.5 141.4
Net Weight kg 784 785 829 830
Net Weight kg 1063 1083 1078 1092
Gross Weight kg 843 844 893 894
Gross Weight kg 1138 1185 1163 1187
Connection Ratio 50% - 150%
Connection Ratio 50% - 150%
Compressor Quantity PC 4 4 4 4
Compressor Quantity PC 6 6 6 6
Condenser Fan Quantity PC 4 4 4 4
Condenser Fan Quantity PC 6 6 6 6
Height Difference Between ODUs is Higher Than IDUs m 50 (90*4)
Height Difference Between ODUs is Higher Than IDUs m 50 (90*4)
ODUs and IDUs ODUs is Lower Than IDUs m 40 (90*4)
ODUs and IDUs ODUs is Lower Than IDUs m 40 (90*4)
Height Difference Between IDUs m 30
Height Difference Between IDUs m 30
Cooling DB -5oC~ 52oC*5
Operation Range Cooling DB -5oC~ 52oC*5
Heating WB -25oC*5~ 16.5oC Operation Range
Heating WB -25oC*5~ 16.5oC
Max. Total Piping Length m 1000
Max. Total Piping Length m 1000

Notes: Notes:
1. Rated cooling capacity and rated heating capacity are tested in the following conditions: 1. Rated cooling capacity and rated heating capacity are tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m
Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene. 2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products. 3.The final appearance of outdoor units is subject to the actual products.
4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer. 4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer.
5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer. 5.When the operation temperature is under 48oC~52oCor -25oC~-20oC, please contact our professional engineer.
37/38
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

Hi-FLEXi S Series HP 66HP 68HP 70HP 72HP Hi-FLEXi S Series HP 74HP 76HP 78HP 80HP

Model AVWT-634HKSS AVWT-654HKSS AVWT-676HKSS AVWT-696HKSS Model AVWT-714HKSS AVWT-732HKSS AVWT-754HKSS AVWT-776HKSS

Combination AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS Combination AVWT-250HKSS AVWT-250HKSS AVWT-272HKSS AVWT-272HKSS
AVWT-212HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS AVWT-250HKSS AVWT-250HKSS AVWT-272HKSS
AVWT-190HKSS AVWT-190HKSS AVWT-212HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS
Power Supply 380-415V 3N~ 50Hz / 60Hz Power Supply 380-415V 3N~ 50Hz / 60Hz
Rated Capacity kW 185.5 192.0 197.5 204.0 Rated Capacity kW 208.5 213.0 220.5 228.0
Cooling Operation*1 Power Consumption kW 61.22 63.54 66.14 68.46 Cooling Operation*1 Power Consumption kW 70.22 71.98 74.99 78.00
EER 3.03 3.02 2.99 2.98 EER 2.97 2.96 2.95 2.92
Rated Capacity kW 207.0 213.0 219.0 225.0 Rated Capacity kW 230.0 235.0 245.0 255.0
Heating Operation*1 Power Consumption kW 66.94 69.05 71.66 73.77 Heating Operation*1 Power Consumption kW 75.85 77.93 81.67 85.41
COP 3.09 3.08 3.06 3.05 COP 3.03 3.02 3.00 2.98
Air Flow Rate m³/min 859 859 888 888 Air Flow Rate m³/min 942 996 996 996
Noise level*2 dB(A) 70 70 70 71 Noise level*2 dB(A) 71 71 71 71
Cabinet Color*3 Grayish White Cabinet Color*3 Grayish White
Compressor Type Enhanced Vapor Injection Compressor Compressor Type Enhanced Vapor Injection Compressor
Refrigerant Type R410A Refrigerant Type R410A
Gas Line mm Φ44.5 Φ50.8 Φ50.8 Φ50.8 Gas Line mm Φ50.8 Φ50.8 Φ50.8 Φ50.8
Liquid Line mm Φ22.2 Φ25.4 Φ25.4 Φ25.4 Liquid Line mm Φ25.4 Φ25.4 Φ25.4 Φ25.4
H mm 1730 1730 1730 1730 H mm 1730 1730 1730 1730
Out Dimension W mm 1350+1350+1350 1350+1350+1350 1350+1350+1350 1350+1350+1350 Out Dimension W mm 1350+1350+1600 1350+1600+1600 1350+1600+1600 1350+1600+1600
D mm 750 750 750 750 D mm 750 750 750 750
H mm 1930 1930 1930 1930 H mm 1930 1930 1930 1930
Packing Dimension W mm 1420+1420+1420 1420+1420+1420 1420+1420+1420 1420+1420+1420 Packing Dimension W mm 1420+1420+1665 1420+1665+1665 1420+1665+1665 1420+1665+1665
D mm 790 790 790 790 D mm 790 790 790 790
Max.number of connectable IDU 64 64 64 64 Max.number of connectable IDU 64 64 64 64
Max. Fuse Current A 200 200 200 200 Max. Fuse Current A 200 200 200 200
Max. Running Current A 146.7 149.3 154.6 157.2 Max. Running Current A 161.7 166.2 167.5 168.8
Net Weight kg 1100 1101 1109 1110 Net Weight kg 1154 1198 1199 1200
Gross Weight kg 1188 1189 1190 1191 Gross Weight kg 1240 1289 1290 1291
Connection Ratio 50% - 150% Connection Ratio 50% - 150%
Compressor Quantity PC 6 6 6 6 Compressor Quantity PC 6 6 6 6
Condenser Fan Quantity PC 6 6 6 6 Condenser Fan Quantity PC 6 6 6 6
Height Difference Between ODUs is Higher Than IDUs m 50 (90*4) Height Difference Between ODUs is Higher Than IDUs m 50 (90*4)
ODUs and IDUs ODUs is Lower Than IDUs m 40 (90*4) ODUs and IDUs ODUs is Lower Than IDUs m 40 (90*4)
Height Difference Between IDUs m 30 Height Difference Between IDUs m 30
Cooling DB -5oC~ 52oC*5 Cooling DB -5oC~ 52oC*5
Operation Range Operation Range
Heating WB -25oC*5~ 16.5oC Heating WB -25oC*5~ 16.5oC
Max. Total Piping Length m 1000 Max. Total Piping Length m 1000
Notes: Notes:
1. Rated cooling capacity and rated heating capacity are tested in the following conditions: 1. Rated cooling capacity and rated heating capacity are tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m
Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene. 2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products. 3.The final appearance of outdoor units is subject to the actual products.
4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer. 4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer.
5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer. 5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer.
39/40
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

Hi-FLEXi S Series HP 82HP 84HP 86HP 88HP Hi-FLEXi S Series HP 90HP 92HP 94HP 96HP

Model AVWT-794HKSS AVWT-816HKSS AVWT-824HKSS AVWT-844HKSS Model AVWT-866HKSS AVWT-886HKSS AVWT-908HKSS AVWT-928HKSS

Combination AVWT-272HKSS AVWT-272HKSS AVWT-232HKSS AVWT-232HKSS Combination AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS
AVWT-272HKSS AVWT-272HKSS AVWT-212HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS
AVWT-250HKSS AVWT-272HKSS AVWT-190HKSS AVWT-190HKSS AVWT-212HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS
AVWT-190HKSS AVWT-190HKSS AVWT-190HKSS AVWT-190HKSS AVWT-212HKSS AVWT-232HKSS
Power Supply 380-415V 3N~ 50Hz / 60Hz Power Supply 380-415V 3N~ 50Hz / 60Hz
Rated Capacity kW 232.5 240.0 241.5 248.0 Rated Capacity kW 253.5 260.0 265.5 272.0
Cooling Operation*1 Power Consumption kW 79.76 82.77 79.12 81.44 Cooling Operation*1 Power Consumption kW 84.04 86.36 88.96 91.28
EER 2.91 2.90 3.05 3.05 EER 3.02 3.01 2.98 2.98
Rated Capacity kW 260.0 270.0 270.0 276.0 Rated Capacity kW 282.0 288.0 294.0 300.0
Heating Operation*1 Power Consumption kW 87.49 91.23 86.81 88.92 Heating Operation*1 Power Consumption kW 91.53 93.64 96.25 98.36
COP 2.97 2.96 3.11 3.10 COP 3.08 3.08 3.05 3.05
Air Flow Rate m³/min 1050 1050 1126 1126 Air Flow Rate m³/min 1155 1155 1184 1184
Noise level*2 dB(A) 72 72 72 72 Noise level*2 dB(A) 72 72 72 72
Cabinet Color*3 Grayish White Cabinet Color*3 Grayish White
Compressor Type Enhanced Vapor Injection Compressor Compressor Type Enhanced Vapor Injection Compressor
Refrigerant Type R410A Refrigerant Type R410A
Gas Line mm Φ50.8 Φ50.8 Φ50.8 Φ50.8 Gas Line mm Φ50.8 Φ50.8 Φ50.8 Φ50.8
Liquid Line mm Φ25.4 Φ25.4 Φ25.4 Φ25.4 Liquid Line mm Φ25.4 Φ25.4 Φ25.4 Φ25.4
H mm 1730 1730 1730 1730 H mm 1730 1730 1730 1730
Out Dimension W mm 1600+1600+1600 1600+1600+1600 1350+1350+1350+1350 1350+1350+1350+1350 Out Dimension W mm 1350+1350+1350+1350 1350+1350+1350+1350 1350+1350+1350+1350 1350+1350+1350+1350
D mm 750 750 750 750 D mm 750 750 750 750
H mm 1930 1930 1930 1930 H mm 1930 1930 1930 1930
Packing Dimension W mm 1665+1665+1665 1665+1665+1665 1420+1420+1420+1420 1420+1420+1420+1420 Packing Dimension W mm 1420+1420+1420+1420 1420+1420+1420+1420 1420+1420+1420+1420 1420+1420+1420+1420
D mm 790 790 790 790 D mm 790 790 790 790
Max.number of connectable IDU 64 64 64 64 Max.number of connectable IDU 64 64 64 64
Max. Fuse Current A 250 250 250 250 Max. Fuse Current A 250 250 250 320
Max. Running Current A 173.3 174.6 191.2 193.8 Max. Running Current A 199.1 201.7 207 209.6
Net Weight kg 1244 1245 1461 1462 Net Weight kg 1470 1471 1479 1480
Gross Weight kg 1340 1341 1583 1584 Gross Weight kg 1585 1586 1587 1588
Connection Ratio 50% - 150% Connection Ratio 50% - 150%
Compressor Quantity PC 6 6 8 8 Compressor Quantity PC 8 8 8 8
Condenser Fan Quantity PC 6 6 8 8 Condenser Fan Quantity PC 8 8 8 8
Height Difference Between ODUs is Higher Than IDUs m 50 (90*4) Height Difference Between ODUs is Higher Than IDUs m 50 (90*4)
ODUs and IDUs ODUs is Lower Than IDUs m 40 (90*4) ODUs and IDUs ODUs is Lower Than IDUs m 40 (90*4)
Height Difference Between IDUs m 30 Height Difference Between IDUs m 30
Cooling DB -5oC~ 52oC*5 Cooling DB -5oC~ 52oC*5
Operation Range Operation Range
Heating WB -25oC*5~ 16.5oC Heating WB -25oC*5~ 16.5oC
Max. Total Piping Length m 1000 Max. Total Piping Length m 1000

Notes: Notes:
1. Rated cooling capacity and rated heating capacity are tested in the following conditions: 1. Rated cooling capacity and rated heating capacity are tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m
Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene. 2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products. 3.The final appearance of outdoor units is subject to the actual products.
4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer. 4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer.
5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer. 5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer.
41/42
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

Hi-FLEXi S Series HP 98HP 100HP 102HP 104HP Hi-FLEXi S Series HP 106HP 108HP 110HP 112HP

Model AVWT-946HKSS AVWT-968HKSS AVWT-988HKSS AVWT-1008HKSS Model AVWT-1026HKSS AVWT-1048HKSS AVWT-1066HKSS AVWT-1088HKSS

Combination AVWT-250HKSS AVWT-272HKSS AVWT-272HKSS AVWT-272HKSS Combination AVWT-272HKSS AVWT-272HKSS AVWT-272HKSS AVWT-272HKSS
AVWT-232HKSS AVWT-232HKSS AVWT-272HKSS AVWT-272HKSS AVWT-272HKSS AVWT-272HKSS AVWT-272HKSS AVWT-272HKSS
AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS AVWT-250HKSS AVWT-272HKSS AVWT-272HKSS AVWT-272HKSS
AVWT-232HKSS AVWT-232HKSS AVWT-212HKSS AVWT-232HKSS AVWT-232HKSS AVWT-232HKSS AVWT-250HKSS AVWT-272HKSS
Power Supply 380-415V 3N~ 50Hz / 60Hz Power Supply 380-415V 3N~ 50Hz / 60Hz
Rated Capacity kW 276.5 284.0 289.5 296.0 Rated Capacity kW 300.5 308.0 312.5 320.0
Cooling Operation*1 Power Consumption kW 93.04 96.05 98.50 100.82 Cooling Operation*1 Power Consumption kW 102.58 105.59 107.35 110.36
EER 2.97 2.96 2.94 2.94 EER 2.93 2.92 2.91 2.90
Rated Capacity kW 305.0 315.0 324.0 330.0 Rated Capacity kW 335.0 345.0 350.0 360.0
Heating Operation*1 Power Consumption kW 100.44 104.18 107.89 110.00 Heating Operation*1 Power Consumption kW 112.08 115.82 117.9 121.64
COP 3.04 3.02 3.00 3.00 COP 2.99 2.98 2.97 2.96
Air Flow Rate m³/min 1238 1238 1292 1292 Air Flow Rate m³/min 1346 1346 1400 1400
Noise level*2 dB(A) 72 72 72 73 Noise level*2 dB(A) 73 73 73 73
Cabinet Color*3 Grayish White Cabinet Color*3 Grayish White
Compressor Type Enhanced Vapor Injection Compressor Compressor Type Enhanced Vapor Injection Compressor
Refrigerant Type R410A Refrigerant Type R410A
Gas Line mm Φ50.8 Φ50.8 Φ50.8 Φ50.8 Gas Line mm Φ50.8 Φ50.8 Φ50.8 Φ50.8
Liquid Line mm Φ25.4 Φ25.4 Φ25.4 Φ25.4 Liquid Line mm Φ25.4 Φ25.4 Φ25.4 Φ25.4
H mm 1730 1730 1730 1730 H mm 1730 1730 1730 1730
Out Dimension W mm 1350+1350+1350+1600 1350+1350+1350+1600 1350+1350+1600+1600 1350+1350+1600+1600 Out Dimension W mm 1350+1600+1600+1600 1350+1600+1600+1600 1600+1600+1600+1600 1600+1600+1600+1600
D mm 750 750 750 750 D mm 750 750 750 750
H mm 1930 1930 1930 1930 H mm 1930 1930 1930 1930
Packing Dimension W mm 1420+1420+1420+1665 1420+1420+1420+1665 1420+1420+1665+1665 1420+1420+1665+1665 Packing Dimension W mm 1420+1665+1665+1665 1420+1665+1665+1665 1665+1665+1665+1665 1665+1665+1665+1665
D mm 790 790 790 790 D mm 790 790 790 790
Max.number of connectable IDU 64 64 64 64 Max.number of connectable IDU 64 64 64 64
Max. Fuse Current A 320 320 320 320 Max. Fuse Current A 320 320 320 320
Max. Running Current A 214.1 215.4 218.6 221.2 Max. Running Current A 225.7 227 231.5 232.8
Net Weight kg 1524 1525 1569 1570 Net Weight kg 1614 1615 1659 1660
Gross Weight kg 1637 1638 1687 1688 Gross Weight kg 1737 1738 1787 1788
Connection Ratio 50% - 150% Connection Ratio 50% - 150%
Compressor Quantity PC 8 8 8 8 Compressor Quantity PC 8 8 8 8
Condenser Fan Quantity PC 8 8 8 8 Condenser Fan Quantity PC 8 8 8 8
Height Difference Between ODUs is Higher Than IDUs m 50 (90*4) Height Difference Between ODUs is Higher Than IDUs m 50 (90*4)
ODUs and IDUs ODUs is Lower Than IDUs m 40 (90*4) ODUs and IDUs ODUs is Lower Than IDUs m 40 (90*4)
Height Difference Between IDUs m 30 Height Difference Between IDUs m 30
Cooling DB -5oC~ 52oC*5 Cooling DB -5oC~ 52oC*5
Operation Range Operation Range
Heating WB -25oC*5~ 16.5oC Heating WB -25oC*5~ 16.5oC
Max. Total Piping Length m 1000 Max. Total Piping Length m 1000

Notes: Notes:
1. Rated cooling capacity and rated heating capacity are tested in the following conditions: 1. Rated cooling capacity and rated heating capacity are tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m
Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene. 2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products. 3.The final appearance of outdoor units is subject to the actual products.
4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer. 4.For height difference between ODU&IDU more than 50(40)m, please contact our professional engineer.
5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer. 5.When the operation temperature is under 48oC~52oC or -25oC~-20oC, please contact our professional engineer.
43/44
OUTDOOR UNIT Product Line

pole

Hi-FLEXi G+ Series 6-pole high-flux neodymium magnetic motor rotor


Motor rotor of the new type compressor uses the latest 6-pole high-
flux neodymium magneto structure, rotor shape design is optimized
and all rotational speed control is more efficient.
Original Latest

Hi-FLEXi G+ Series is the latest larger capacity full DC inverter-driven


multi-split central air conditioning product. It focuses on customers'
requirement and comfort, representing Hisense high quality and New improved concentrated stator winding
technology. It’s characterized by: The new type motor stator is equipped with a centralized winding
and more turns of windings, sets induced voltage to a higher value
(to reduce current) and improves efficiency of motor at low rotational
Latest enhanced capacity series: speed.

Brand new high-pressure chamber scroll compressor


Integrated high-strength structure and convenient installation
Improved super-cooling
Adoption of double larger fans and low-pressure loss heat exchanger
The optimization of finned tubes, increasing of
Max. 22HP single unit, 4 modules' combination fins number and reducing of height on the basis of
traditional secondary super-cooler reduces its pressure
loss, increases coefficient of heat conduction and
improves super-cooling performance.

Upgraded Core Technology High-precise multiple electronic expansion valves control technology
The multiple high-precision electronic expansion valves equipped
New Hitachi high-pressure chamber scroll compressor, enhancing the efficiency on the outdoor unit can adjust refrigerant flow of the unit rapidly and
accurately according to commands, reduce power consumption
Adoption of the brand new high-pressure chamber scroll compressor realizes high efficiency of motor, optimization of during operation, improve energy efficiency and reduce fluctuation of
scroll plate and optimum fuel feeding, etc. and increases operation efficiency of compressor under overall operating indoor temperature, thus making the environment more comfortable
conditions, especially, enhances intermediate performance greatly. and pleasant. Electronic expansion valve

High pressure Anti-overcompressing


chamber structure Technique
Exclusive asymmetric
Oil film sealing
scroll technology
Optimization of the four-way valve Optimization of ball check valve
technology
Exclusive inner oil Adoption of the new type high-capacity four-way The brand-new ball check valve, in which there
Discharge pipes separating pipe valve reduces compression at four-way valve is almost no part hindering fluid flow and thus
New centralized greatly, ensures suction intensity of compressor and the local pressure loss is improved significantly,
High strength stator winding improves performance of the complete machine. enhances efficiency of the whole system.
roller-bearing

Sensorless protection Hitachi patent neodymium


magnet motor rotor

Oil sump shield


High strength shell design High capacity and
Inner compressor less pressure
cleaning function loss four-way valve

Motor is the source of power of a compressor. Hi-FLEXi G+ Series compressor is equipped with a new DC motor
(with centralized winding) which enhances performance of the compressor significantly at a frequency of 20-80Hz
that the compressor operates at most frequently.
45/46
OUTDOOR UNIT Product Line

Wide Operation Range New Appearance

The built-in design of PP air duct ensures safety of inner core effectively
The highest working temperature Combination of the integrated sheet-metal upper cover and protecting wire net structure realizes built-in design of PP air
reaches upto 52°C in cooling mode, duct with optimal protection performance, effectively protecting important parts (e.g. fan) from being damaged when the
and lowest working temperature outdoor unit being hit by object from high altitudes.
reaches -20°C in heating mode.

A
Note: when the designed cooling temperature is over 43oC,
please contact our professional engineer. High strength motor bracket, more stable
A and quiet
B B

High strength frame structure with inside


More Flexible Refrigerant Piping Work B upright column

Max. piping length: 190m*


Max. total piping length: 1000m

Height difference between outdoor and indoor unit


Outdoor unit is higher: 90m* Integrated high-strength side plate decreases vibration and reduces noises
Outdoor unit is lower: 90m*
Compared with the form combining stand column with wire net, Hi-FLEXi G+ Series is equipped with integrated high-
strength side plates made from high-quality materials, which increases air handling area and reduces the vibration and
Height difference between indoor units: 30m* noises produced during operation of the machine.
Max. piping length between 1st branch and
indoor unit: 90m

Note: For data marked by *, please contact our professional engineer.

New-efficiency
Common air conditioner Hi-FLEXi G+ Series

The Hi-FLEXi G+ Series adopts new structure The 644mm large dual-fan leads the industry
and advanced technology, providing new High Hi-FLEXi G+ Series (20-22HP) is equipped with 644mm×2

644mm
efficiency combination solution. large fans characterized by low noise and large air
flow, greatly improving heat exchange efficiency of heat
exchanger.
Common double fans Hisense double large
diameter: 540mm fans diameter: 644mm
47/48
OUTDOOR UNIT Product Line

6-side heat exchanging of low pressure-loss ∑ type heat exchanger


New Installation
The low pressure-loss ∑ type heat exchanger is structurally designed with a 6-side heat exchange structure and dual-fan,
which realizes more uniform distribution of heat exchanger's wind field gradient under the same air-flow conditions, and
improves heat-exchanging efficiency of heat exchanger. Meanwhile, higher height, larger heat exchange area and low
pressure-loss optimization of flow in bypass branch of the heat exchanger itself improves heat-exchanging efficiency of
refrigerant and ensures strong heat-exchanging performance of the complete machine.
The modular design makes installation easier
Hi-FLEXi G+ Series is characterized by compact structure and modular
design by breaking up the whole system into parts, making it easier
for both installation and transportation. Taking 88HP as an example,
capacity of a single-module product is up to 22HP. And, it can be an
assembly of 4 modules, not only meeting the high-capacity requirement
but effectively save the space.
The volume is convenient for
elevator transportation

Large outdoor heat exchanger of Integrated four-side heat Common four-side heat
Large outdoor heat exchanger Hisense exchanger exchanger

For the large outdoor heat exchanger of Static pressure of outdoor unit is up to 85Pa
Hisense, the heat exchanger is characterized The maximum static pressure of outdoor unit is up to 85Pa and is suitable for layered installation and centralized
by larger face area and better heat-exchanging installation.
efficiency. Meanwhile, it reserves more space for The higher static pressure and longer air supplying distance of outdoor unit ensures smooth circulation of air flow and
arrangement of piping of refrigerating system and solves the problem of heat dissipation of outdoor unit effectively.
heat exchanger distribution pipe, thus ensuring The outdoor unit featured with higher static pressure, well responds to the severe environment where the outdoor unit is
better maintainability. placed at, is available for more flexible arrangement and is favorable for concealed installation of outdoor unit.

*Note: for details, please consult the technical personnel.

1.90

Note: the other shape of heat exchanger is taken as an example.

Separation of machine room and electric room makes maintenance more convenient
In the new structure, divisional design of front metal plate, separate assembling of metal plates in each part and Max.
separation of electric room and machine room improve repair and maintenance convenience. Modularized design 85Pa
of electric box and spatial independence of two variable frequency compressors’ control circuits reduce mutual
crosstalk, enhance EMC performance greatly and make heat emission efficiency better.

Layered arrangement of outdoor Favorable for concealed installation Air distribution schematic
unit solves the problem of heat of outdoor unit and making the diagram
dissipation easily facade more aesthetic
49/50
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

Hi-FLEXi G+ Series HP 8HP 10HP 12HP 14HP Hi-FLEXi G+ Series HP 16HP 18HP 20HP 22HP

AC3Φ380V~415V/50/60Hz AVWT-76UKSNA AVWT-96UKSNA AVWT-114UKSNA AVWT-136UKSTA AC3Φ380V~415V/50/60Hz AVWT-154UKSTA AVWT-170UKSTA AVWT-190UKS1A AVWT-212UKS1A
Model Power Supply Model Power Supply
AC3Φ208~230V/60Hz AVWT-76U8SNA AVWT-96U8SNA AVWT-114U8SNA AVWT-136U8STA AC3Φ208~230V/60Hz AVWT-154U8STA AVWT-170U8STA AVWT-190U8S1A AVWT-212U8S1A

Combination Combination
kW 22.4 28.0 33.5 40.0 kW 45.0 50.0 56.0 61.5
Nominal Capacity Nominal Capacity
KBtu/h 76.4 95.5 114.3 136.5 KBtu/h 153.5 170.6 191.1 209.8
Cooling Operation Cooling Operation
Power Consumption kW 5.00 6.95 8.66 10.61 Power Consumption kW 12.61 14.37 16.42 20.10
EER 4.48 4.03 3.87 3.77 EER 3.57 3.48 3.41 3.06
kW 25.0 31.5 37.5 45.0 kW 50.0 56.0 63.0 69.0
Nominal Capacity Nominal Capacity
KBtu/h 85.3 107.5 128.0 153.5 KBtu/h 170.6 191.1 215.0 235.4
Heating Operation Heating Operation
Power Consumption kW 5.00 6.35 8.06 9.91 Power Consumption kW 12.29 13.97 16.41 19.11
COP 5.00 4.96 4.65 4.54 COP 4.07 4.01 3.84 3.61
Air Flow Rate m³/h 9,300 10,200 10,500 11,700 Air Flow Rate m³/h 11,700 14,400 15,300 16,200
Outer Dimension (H×W×D) mm 1,730×950×750 1,730×950×750 1,730×950×750 1,730×1,210×750 Outer Dimension (H×W×D) mm 1,730×1,210×750 1,730×1,210×750 1,730×1,350×750 1,730×1,350×750
Packing Dimension (H×W×D) mm 1,930×1,015×790 1,930×1,015×790 1,930×1,015×790 1,930×1,275×790 Packing Dimension (H×W×D) mm 1,930×1,275×790 1,930×1,275×790 1,930×1,420×790 1,930×1,420×790
Net Weight Kg 239 240 241 331 Net Weight Kg 332 333 394 395
Gross Weight Kg 251 252 253 353 Gross Weight Kg 354 355 415 416
Compressor Quantity 1 1 1 2 Compressor Quantity 2 2 2 2
Condenser Fan Quantity 1 1 1 1 Condenser Fan Quantity 1 1 2 2
Cabinet Color Ivory White Cabinet Color Ivory White
Gas Line mm Ф19.05 Ф22.2 Ф25.4 Ф25.4 Gas Line mm Ф28.6 Ф28.6 Ф28.6 Ф28.6
Refrigerant Piping Refrigerant Piping
Liquid Line mm Ф9.53 Ф9.53 Ф12.7 Ф12.7 Liquid Line mm Ф12.7 Ф15.88 Ф15.88 φ15.88
Max. number of connectable IDU 13 16 19 23 Max. number of connectable IDU 26 26 33 36
Max. Piping Length m 165(190*) 165(190*) 165(190*) 165(190*) Max. Piping Length m 165(190*) 165(190*) 165(190*) 165(190*)
Between ODU&IDU m 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) Between ODU&IDU m 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*)
Height Difference Height Difference
Between IDUs m 15(30*) 15(30*) 15(30*) 15(30*) Between IDUs m 15(30*) 15(30*) 15(30*) 15(30*)
Noise Level (208~230V/380~415V) dB(A) 63/64 65/65 65/66 66/68 Noise Level (208~230V/380~415V) dB(A) 66/68 67/68 69/69 69/69
Cooling o
C DB -5~52* Cooling o
C DB -5~52*
Operation Range Operation Range
Heating o
C WB -20~16.5 Heating o
C WB -20~16.5

Notes: Notes:
1. Rated cooling capacity and rated heating capacity are tested in the following conditions: 1. Rated cooling capacity and rated heating capacity are tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height difference: 0m Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height difference: 0m
Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene. 2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products. 3.The final appearance of outdoor units is subject to the actual products.
4.For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more 4.For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more
than 15m, please contact our professional engineer. than 15m, please contact our professional engineer.
5.When the cooling operation temperature is over 43oC, please contact our professional engineer. 5.When the cooling operation temperature is over 43oC, please contact our professional engineer.
51/52
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

Hi-FLEXi G+ Series HP 24HP 26HP 28HP 30HP 32HP 34HP Hi-FLEXi G+ Series HP 36HP 38HP 40HP 42HP 44HP

AC3Φ380V~415V/50/60Hz AVWT-232UKSZA AVWT-250UKSZA AVWT-268UKSZA AVWT-287UKSZA AVWT-306UKSZA AVWT-324UKSZA AC3Φ380V~415V/50/60Hz AVWT-340UKSZA AVWT-364UKSZA AVWT-382UKSZA AVWT-398UKSZA AVWT-420UKSZA
Model Power Supply Model Power Supply
AC3Φ208~230V/60Hz AVWT-232U8SZA AVWT-250U8SZA AVWT-268U8SZA AVWT-287U8SZA AVWT-306U8SZA AVWT-324U8SZA AC3Φ208~230V/60Hz AVWT-340U8SZA AVWT-364U8SZA AVWT-382U8SZA AVWT-398U8SZA AVWT-420U8SZA

AVWT-96U* AVWT-114U* AVWT-114U* AVWT-96U* AVWT-114U* AVWT-154U* AVWT-170U* AVWT-154U* AVWT-190U* AVWT-190U* AVWT-212U*
Combination Combination
AVWT-136U* AVWT-136U* AVWT-154U* AVWT-190U* AVWT-190U* AVWT-170U* AVWT-170U* AVWT-212U* AVWT-190U* AVWT-212U* AVWT-212U*
kW 68.0 73.5 78.5 84.0 89.5 95 kW 100 106.5 112 117.5 123
Nominal Capacity Nominal Capacity
KBtu/h 232.0 250.8 267.8 286.6 305.4 324.1 KBtu/h 341.2 363.4 382.1 400.9 419.7
Cooling Operation Cooling Operation
Power Consumption kW 17.56 19.27 21.26 23.37 25.08 26.97 Power Consumption kW 28.74 32.70 32.84 36.52 40.20
EER 3.87 3.81 3.69 3.59 3.57 3.52 EER 3.48 3.26 3.41 3.22 3.06
kW 76.5 82.5 87.5 94.5 100.5 106.0 kW 112.0 119.0 126.0 132.0 138.0
Nominal Capacity Nominal Capacity
KBtu/h 261.0 281.5 298.6 322.4 342.9 361.7 KBtu/h 382.1 406.0 429.9 450.4 470.9
Heating Operation Heating Operation
Power Consumption kW 16.3 18.0 20.3 22.8 24.5 26.25 Power Consumption kW 27.9 31.4 32.8 35.5 38.2
COP 4.71 4.59 4.30 4.15 4.11 4.04 COP 4.01 3.79 3.84 3.72 3.61
Air Flow Rate m³/h 21,900 22,200 22,200 25,500 25,800 26,100 Air Flow Rate m³/h 28,800 27,900 30,600 31,500 32,400
Outer Dimension (H×W×D) mm 1,730×(950+1,210)×750 1,730×(950+1,350)×750 1,730×(1,210+1,210)×750 Outer Dimension (H×W×D) mm 1,730×(1,210+1,210)×750 1,730×(1,210+1,350)×750 1,730×(1,350+1,350)×750
Packing Dimension (H×W×D) mm 1,930×(1,015+1,275)×790 1,930×(1,015+1,420)×790 1,930×(1,275+1,275)×790 Packing Dimension (H×W×D) mm 1,930×(1,275+1,275)×790 1,930×(1,275+1,420)×790 1,930×(1,420+1,420)×790
Net Weight Kg 571 572 573 634 635 665 Net Weight Kg 666 727 788 789 790
Gross Weight Kg 605 606 607 667 668 709 Gross Weight Kg 710 770 830 831 832
Compressor Quantity 3 3 3 3 3 4 Compressor Quantity 4 4 4 4 4
Condenser Fan Quantity 2 2 2 3 3 2 Condenser Fan Quantity 2 3 4 4 4
Cabinet Color Ivory White Cabinet Color Ivory White
Gas Line mm Ф28.6 Ф31.75 Ф31.75 Ф31.75 Ф31.75 Ф38.1 Gas Line mm Ф38.1 Ф38.1 Ф38.1 Ф38.1 Ф38.1
Refrigerant Piping Refrigerant Piping
Liquid Line mm Ф15.88 Ф19.05 Ф19.05 Ф19.05 Ф19.05 Ф19.05 Liquid Line mm Ф19.05 Ф19.05 Ф19.05 Ф19.05 Ф19.05
Max. number of connectable IDU 40 43 47 50 53 56 Max. number of connectable IDU 59 64 64 64 64
Max. Piping Length m 165(190*) 165(190*) 165(190*) 165(190*) 165(190*) 165(190*) Max. Piping Length m 165(190*) 165(190*) 165(190*) 165(190*) 165(190*)
Between ODU&IDU m 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) Between ODU&IDU m 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*)
Height Difference Height Difference
Between IDUs m 15(30*) 15(30*) 15(30*) 15(30*) 15(30*) 15(30*) Between IDUs m 15(30*) 15(30*) 15(30*) 15(30*) 15(30*)
Noise Level (208~230V/380~415V) dB(A) 68/69 69/70 71/73 72/73 72/73 72/73 Noise Level (208~230V/380~415V) dB(A) 72/73 72/73 74/74 74/74 74/74
o o
Cooling C DB -5~52* Cooling C DB -5~52*
Operation Range o
Operation Range o
Heating C WB -20~16.5 Heating C WB -20~16.5

Notes: Notes:
1. Rated cooling capacity and rated heating capacity are tested in the following conditions: 1. Rated cooling capacity and rated heating capacity are tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height difference: 0m Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height difference: 0m
Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7℃ DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene. 2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products. 3.The final appearance of outdoor units is subject to the actual products.
4.For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more 4.For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more
than 15m, please contact our professional engineer. than 15m, please contact our professional engineer.
5.When the cooling operation temperature is over 43oC, please contact our professional engineer. 5.When the cooling operation temperature is over 43oC, please contact our professional engineer.
53/54
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

Hi-FLEXi G+ Series HP 46HP 48HP 50HP 52HP 54HP Hi-FLEXi G+ Series HP 56HP 58HP 60HP 62HP 64HP 66HP

AC3Φ380V~415V/50/60Hz AVWT-438UKSZA AVWT-454UKSZA AVWT-476UKSZA AVWT-494UKSZA AVWT-510UKSZA AC3Φ380V~415V/50/60Hz AVWT-534UKSZA AVWT-551UKSZA AVWT-572UKSZA AVWT-590UKSZA AVWT-611UKSZA AVWT-630UKSZA
Model Power Supply Model Power Supply
AC3Φ208~230V/60Hz AVWT-438U8SZA AVWT-454U8SZA AVWT-476U8SZA AVWT-494U8SZA AVWT-510U8SZA AC3Φ208~230V/60Hz AVWT-534U8SZA AVWT-551U8SZA AVWT-572U8SZA AVWT-590U8SZA AVWT-611U8SZA AVWT-630U8SZA

AVWT-114U* AVWT-114U* AVWT-114U* AVWT-114U* AVWT-170U* AVWT-154U* AVWT-170U* AVWT-170U* AVWT-170U* AVWT-190U* AVWT-212U*
Combination AVWT-154U* AVWT-170U* AVWT-154U* AVWT-170U* AVWT-170U* Combination AVWT-170U* AVWT-170U* AVWT-190U* AVWT-212U* AVWT-212U* AVWT-212U*
AVWT-170U* AVWT-170U* AVWT-212U* AVWT-212U* AVWT-170U* AVWT-212U* AVWT-212U* AVWT-212U* AVWT-212U* AVWT-212U* AVWT-212U*
kW 128.5 133.5 140 145.0 150 kW 156.5 161.5 167.5 173 179 184.5
Nominal Capacity Nominal Capacity
KBtu/h 438.4 455.5 477.7 494.7 511.8 KBtu/h 534.0 551.0 571.5 590.3 610.7 629.5
Cooling Operation Cooling Operation
Power Consumption kW 35.63 37.39 41.36 43.12 43.10 Power Consumption kW 47.07 48.83 50.89 54.56 56.62 60.29
EER 3.61 3.57 3.38 3.36 3.48 EER 3.32 3.31 3.29 3.17 3.16 3.06
kW 143.5 149.5 156.5 162.5 168.0 kW 175.0 181.0 188.0 194.0 201.0 207.0
Nominal Capacity Nominal Capacity
KBtu/h 489.6 510.1 534.0 554.5 573.2 KBtu/h 597.1 617.6 641.5 661.9 685.8 706.3
Heating Operation Heating Operation
Power Consumption kW 34.3 35.99 39.5 41.1 41.9 Power Consumption kW 45.4 47.0 49.5 52.2 54.6 57.3
COP 4.18 4.15 3.97 3.95 4.01 COP 3.86 3.85 3.80 3.72 3.68 3.61
Air Flow Rate m³/h 36,600 39,300 38,400 41,100 43,200 Air Flow Rate m³/h 42,300 45,000 45,900 46,800 47,700 48,600
Outer Dimension (H×W×D) mm 1,730×(950+1,210+1,210)×750 1,730×(950+12,10+1,350)×750 1,730×(1,210+1,210+1,210)×750 Outer Dimension (H×W×D) mm 1,730×(1,210+1,210+1,350)×750 1,730×(1,210+1,350+1,350)×750 1,730×(1,350+1,350+1,350)×750
Packing Dimension (H×W×D) mm 1,930×(1,015+1,275+1,275)×790 1,930×(1,015+1,275+1,420)×790 1,930×(1,275+1,275+1,275)×790 Packing Dimension (H×W×D) mm 1,930×(1,275+1,275+1,420)×790 1,930×(1,210+1,420+1,420)×790 1,930×(1,420+1,420+1,420)×790
Net Weight Kg 906 907 968 969 999 Net Weight Kg 1,060 1,061 1,122 1,123 1,184 1,185
Gross Weight Kg 962 963 1,023 1,024 1,065 Gross Weight Kg 1,125 1,126 1,186 1,187 1,247 1,248
Compressor Quantity 5 5 5 5 6 Compressor Quantity 6 6 6 6 6 6
Condenser Fan Quantity 3 3 4 4 3 Condenser Fan Quantity 4 4 5 5 6 6
Cabinet Color Ivory White Cabinet Color Ivory White
Gas Line mm Ф41.3 Ф41.3 Ф41.3 Ф41.3 Ф41.3 Gas Line mm Ф41.3 Ф44.5 Ф44.5 Ф44.5 Ф44.5 Ф44.5
Refrigerant Piping Refrigerant Piping
Liquid Line mm Ф22.2 Ф22.2 Ф22.2 Ф22.2 Ф22.2 Liquid Line mm Ф22.2 Ф22.2 Ф22.2 Ф22.2 Ф22.2 Ф22.2
Max. number of connectable IDU 64 64 64 64 64 Max. number of connectable IDU 64 64 64 64 64 64
Max. Piping Length m 165(190*) 165(190*) 165(190*) 165(190*) 165(190*) Max. Piping Length m 165(190*) 165(190*) 165(190*) 165(190*) 165(190*) 165(190*)
Between ODU&IDU m 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) Between ODU&IDU m 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*)
Height Difference Height Difference
Between IDUs m 15(30*) 15(30*) 15(30*) 15(30*) 15(30*) Between IDUs m 15(30*) 15(30*) 15(30*) 15(30*) 15(30*) 15(30*)
Noise Level (208~230V/380~415V) dB(A) 74/75 74/75 74/75 74/75 75/75 Noise Level (208~230V/380~415V) dB(A) 75/76 75/76 76/76 76/76 76/76 76/76
o o
Cooling C DB -5~52* Cooling C DB -5~52*
Operation Range o
Operation Range o
Heating C WB -20~16.5 Heating C WB -20~16.5

Notes: Notes:
1. Rated cooling capacity and rated heating capacity are tested in the following conditions: 1. Rated cooling capacity and rated heating capacity are tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height difference: 0m
Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene. 2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products. 3.The final appearance of outdoor units is subject to the actual products.
4.For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more 4.For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more
than 15m, please contact our professional engineer. than 15m, please contact our professional engineer.
5.When the cooling operation temperature is over 43oC, please contact our professional engineer. 5.When the cooling operation temperature is over 43oC, please contact our professional engineer.
55/56
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

Hi-FLEXi G+ Series HP 68HP 70HP 72HP 74HP 76HP 78HP Hi-FLEXi G+ Series HP 80HP 82HP 84HP 86HP 88HP

AC3Φ380V~415V/50/60Hz AVWT-649UKSZA AVWT-666UKSZA AVWT-688UKSZA AVWT-705UKSZA AVWT-722UKSZA AVWT-742UKSZA AC3Φ380V~415V/50/60Hz AVWT-761UKSZA AVWT-782UKSZA AVWT-800UKSZA AVWT-821UKSZA AVWT-840UKSZA
Model Power Supply Model Power Supply
AC3Φ208~230V/60Hz AVWT-649U8SZA AVWT-666U8SZA AVWT-688U8SZA AVWT-705U8SZA AVWT-722U8SZA AVWT-742U8SZA AC3Φ208~230V/60Hz AVWT-761U8SZA AVWT-782U8SZA AVWT-800U8SZA AVWT-821U8SZA AVWT-840U8SZA

AVWT-114U* AVWT-114U* AVWT-114U* AVWT-114U* AVWT-170U* AVWT-170U* AVWT-170U* AVWT-170U* AVWT-170U* AVWT-190U* AVWT-212U*
AVWT-154U* AVWT-170U* AVWT-154U* AVWT-170U* AVWT-170U* AVWT-170U* AVWT-170U* AVWT-190U* AVWT-212U* AVWT-212U* AVWT-212U*
Combination Combination
AVWT-170U* AVWT-170U* AVWT-212U* AVWT-212U* AVWT-170U* AVWT-190U* AVWT-212U* AVWT-212U* AVWT-212U* AVWT-212U* AVWT-212U*
AVWT-212U* AVWT-212U* AVWT-212U* AVWT-212U* AVWT-212U* AVWT-212U* AVWT-212U* AVWT-212U* AVWT-212U* AVWT-212U* AVWT-212U*
kW 190 195 201.5 206.5 211.5 217.5 kW 223 229 234.5 240.5 246
Nominal Capacity Nominal Capacity
KBtu/h 648.3 665.3 687.5 704.6 721.6 742.1 KBtu/h 760.9 781.3 800.1 820.6 839.4
Cooling Operation Cooling Operation
Power Consumption kW 57.51 57.49 61.46 63.22 63.20 65.26 Power Consumption kW 68.93 70.99 74.66 76.72 80.39
EER 3.30 3.39 3.28 3.27 3.35 3.33 EER 3.24 3.23 3.14 3.13 3.06
kW 212.5 218.5 225.5 231.5 237.0 244.0 kW 250.0 257.0 263.0 270.0 276.0
Nominal Capacity Nominal Capacity
KBtu/h 725.1 745.5 769.4 789.9 808.6 832.5 KBtu/h 853.0 876.9 897.4 921.2 941.7
Heating Operation Heating Operation
Power Consumption kW 53.4 55.1 58.6 60.2 61.0 63.4 Power Consumption kW 66.2 68.6 71.3 73.7 76.5
COP 3.98 3.97 3.85 3.84 3.88 3.85 COP 3.78 3.75 3.69 3.66 3.61
Air Flow Rate m³/h 52,800 55,500 54,600 57,300 59,400 60,300 Air Flow Rate m³/h 61,200 62,100 63,000 63,900 64,800
mm 1,730×(950+1,210 1,730×(950+1,210 1,730×(1,210+1,210 1,730×(1,210+1,210 mm 1,730×(1,210+1,210
Outer Dimension (H×W×D) +1,210+1,350)×750 +1,210+1,350)×750
1,730×(950+1,210+1,350+1,350)×750
+1,210+1,350)×750 +1,350+1,350)×750 Outer Dimension (H×W×D) +1,350+1,350)×750 1,730×(1,210+1,350+1,350+1,350)×750 1,730×(1,350+1,350+1,350+1,350)×750
1,930×(1,015+1,275 1,930×(1,015+1,275 1,930×(1,275+1,275 1,930×(1,275+1,275 1,930×(1,275+1,275
Packing Dimension (H×W×D) mm +1,275+1,420)×790 +1,275+1,420)×790
1,930×(1,015+1,210+1,420+1,420)×790
+1,275+1,420)×790 +1,420+1,420)×790 Packing Dimension (H×W×D) mm +1,420+1,420)×790 1,930×(1,275+1,420+1,420+1,420)×790 1,930×(1,420+1,420+1,420+1,420)×790
Net Weight Kg 1,301 1,302 1,363 1,364 1,394 1,455 Net Weight Kg 1,456 1,517 1,518 1,579 1,580
Gross Weight Kg 1,378 1,379 1,439 1,440 1,481 1,541 Gross Weight Kg 1,542 1,602 1,603 1,663 1,664
Compressor Quantity 7 7 7 7 8 8 Compressor Quantity 8 8 8 8 8
Condenser Fan Quantity 5 5 6 6 5 6 Condenser Fan Quantity 6 7 7 8 8
Cabinet Color Ivory White Cabinet Color Ivory White
Gas Line mm Ф50.8 Ф50.8 Ф50.8 Ф50.8 Ф50.8 Ф50.8 Gas Line mm Ф50.8 Ф50.8 Ф50.8 Ф50.8 Ф50.8
Refrigerant Piping Refrigerant Piping
Liquid Line mm Ф25.4 Ф25.4 Ф25.4 Ф25.4 Ф25.4 Ф25.4 Liquid Line mm Ф25.4 Ф25.4 Ф25.4 Ф25.4 Ф25.4
Max. number of connectable IDU 64 64 64 64 64 64 Max. number of connectable IDU 64 64 64 64 64
Max. Piping Length m 165(190*) 165(190*) 165(190*) 165(190*) 165(190*) 165(190*) Max. Piping Length m 165(190*) 165(190*) 165(190*) 165(190*) 165(190*)
Between ODU&IDU m 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) Between ODU&IDU m 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*)
Height Difference Height Difference
Between IDUs m 15(30*) 15(30*) 15(30*) 15(30*) 15(30*) 15(30*) Between IDUs m 15(30*) 15(30*) 15(30*) 15(30*) 15(30*)
Noise Level (208~230V/380~415V) dB(A) 76/77 76/77 76/77 76/77 76/77 76/77 Noise Level (208~230V/380~415V) dB(A) 77/77 77/77 77/77 77/77 77/77
o o
Cooling C DB -5~52* Cooling C DB -5~52*
Operation Range o
Operation Range o
Heating C WB -20~16.5 Heating C WB -20~16.5

Notes: Notes:
1. Rated cooling capacity and rated heating capacity are tested in the following conditions: 1. Rated cooling capacity and rated heating capacity are tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length: 7.5m, pipe height difference: 0m Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height difference: 0m
Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m Heating conditions: indoor air inlet temperature: 20oC DB, Outdoor air inlet temperature: 7oC DB 6oC WB, pipe length: 7.5m, pipe height difference : 0m
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene. 2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products. 3.The final appearance of outdoor units is subject to the actual products.
4.For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more 4.For Max. pipe length more than 165m, height difference between outdoor unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units (IDUs) more
than 15m, please contact our professional engineer. than 15m, please contact our professional engineer.
5.When the cooling operation temperature is over 43oC, please contact our professional engineer. 5.When the cooling operation temperature is over 43oC, please contact our professional engineer.
57/58
OUTDOOR UNIT Product Line

Super-long Piping Conditions, More Convenient Design


Hi-FLEXi X Series Max. piping length: 190m*
Max. total piping length: 1000m

Height difference between outdoor and indoor unit


Outdoor unit is higher: 90m*
Outdoor unit is lower: 90m*
Hi-FLEXi X Series is equipped with large capacity full DC inverter
compressor. The wide capacity range and compact structure design
make it suitable for various place such as office building, shopping Height difference between indoor units: 30m*
mall, hospital, school and so on. Max. piping length between 1st branch and
indoor unit: 90m

High efficiency and large capacity scroll compressor


Latest DC inverter-driven technology
Stepless fan speed regulation technology
Smart and accurate unit capacity allocation technology Note: For data marked by ※, please contact with our professional engineer.

Intelligent control mode

Layered Installation, Flexibly Corresponding to High-rise Buildings


For high-rise buildings,machine layer can be left to place outdoor units ,or machine room can be set up on each
floor,By using exhaust duct to exhaust the air ,with long distance supply air ,can effectively prevent short circuit of return
Wide Operating Range air,ensure good ventilation and heat exchange effects of outdoor units.

Temperature℃
46.9443

The system can run in a wide temperature range, the lowest temperature can reach -20oC WB,ensure a good heating 45.4512
effect in winter. 43.9582

42.4651
40.9721

39.4790

37.9859
-20oC WB +15oC WB
36.4929
34.9998

Heating operation range Airflow Schematic Exhaust duct installation Layered installation effect picture

-5oC DB +52oC DB Extra-high external static pressure design


The efficient axial fan is designed adopting CFD, finite
Max. 85Pa
element method, aviation dynamic fluid simulation
Cooling operation range
analysis and other advanced concepts; its air inlet angle
and outlet angle are optimized; together with unique horn
air vent design, the external static pressure of outdoor
unit is higher, which can better exhaust air and ensure
-25 -15 -5 5 15 25 35 45 55 Max. 85Pa
smooth air flow.
Adopt high-efficiency DC fan motor
The use of high-efficiency fan reduces energy consumption of the motor
Can achieve industry-leading level of external static pressure 85Pa
59/60
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

8/10HP 12/14/16HP 18HP 20/22HP 24/26/28/30/32HP

Hi-FLEXi X Series HP 8HP 10HP 12HP 14HP 16HP 18HP Hi-FLEXi X Series HP 20HP 22HP 24HP 26HP 28HP 30HP 32HP
AVWT- AVWT- AVWT- AVWT- AVWT- AVWT- AVWT-
Model Power Supply AC3Φ380~415V/50Hz AVWT-76UESRX AVWT-96UESRX AVWT-114UESSX AVWT-136UESSX AVWT-154UESSX AVWT-172UESZX Model Power Supply AC3Φ380~415V/50Hz 190UESZX 210UESZX 229UESZX 250UESZX 268UESZX 290UESZX 307UESZX
AVWT-76UESRX AVWT-76UESRX AVWT-96UESRX AVWT-114UESSX AVWT-114UESSX AVWT-114UESSX AVWT-136UESSX AVWT-154UESSX
Combination Combination
AVWT-96UESRX AVWT-114UESSX AVWT-114UESSX AVWT-114UESSX AVWT-136UESSX AVWT-154UESSX AVWT-154UESSX AVWT-154UESSX
kW 22.4 28.0 33.5 40.0 45.0 50.4 kW 56.0 61.5 67.0 73.5 78.5 85.0 90.0
Cooling Capacity Cooling Capacity
KBtu/h 76.5 95.6 114.3 136.5 153.5 172.0 KBtu/h 191.1 209.8 228.6 250.8 267.8 290 307.1
Cooling Operation Cooling Operation
Power Consumption kW 5.25 7.31 8.57 11.05 13.16 12.56 Power Consumption kW 13.82 15.88 17.14 19.62 21.73 24.21 26.32
EER 4.27 3.83 3.91 3.62 3.42 4.01 EER 4.05 3.87 3.91 3.75 3.61 3.51 3.42
kW 25.0 31.5 37.5 45.0 50.0 56.5 kW 62.5 69.0 75.0 82.5 87.5 95.0 100.0
Heating Capacity Heating Capacity
KBtu/h 85.3 107.5 128.0 153.5 170.6 192.8 KBtu/h 213.3 235.5 256.0 281.5 298.6 324.1 341.2
Heating Operation Heating Operation
Power Consumption kW 5.62 7.61 8.89 11.08 12.47 13.23 Power Consumption kW 14.51 16.5 17.78 19.97 21.36 23.55 24.94
COP 4.45 4.14 4.22 4.06 4.01 4.27 COP 4.31 4.18 4.22 4.13 4.10 4.03 4.01
Air Flow Rate m³/min 155 170 175 190 190 155+170 Air Flow Rate m³/min 155+175 170+175 175+175 175+190 175+190 190+190 190+190
Outer Dimension (H×W×D) mm 1,720×950×750 1,720×1,210×750 1,720×(950+950)×750 Outer Dimension (H×W×D) mm 1,720×(950+1,210)×750 1,720×(1,210+1,210)×750
Packing Dimension (H×W×D) mm 1,882×1,018×828 1,882×1,278×828 Packing Dimension (H×W×D) mm
Net Weight Kg 197 197 224 227 247 197+197 Net Weight Kg 197+224 197+224 224+224 224+227 224+247 227+247 247+247
Gross Weight Kg 223 223 248 250 272 223+223 Gross Weight Kg 223+248 223+248 248+248 248+250 248+272 250+272 272+272
Compressor Quantity 1 1 1 1 1 1+1 Compressor Quantity 1+1 1+1 1+1 1+1 1+1 1+1 1+1
Condenser Fan Quantity 1 1 1 1 1 1+1 Condenser Fan Quantity 1+1 1+1 1+1 1+1 1+1 1+1 1+1
Cabinet Color Ivory White Cabinet Color Ivory White
Gas Line mm Φ19.05 Φ22.2 Φ25.4 Φ25.4 Φ28.6 Φ28.6 Gas Line mm Φ28.6 Φ28.6 Φ28.6 Φ31.75 Φ31.75 Φ31.75 Φ31.75
Refrigerant Piping Refrigerant Piping
Liquid Line mm Φ9.53 Φ9.53 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Liquid Line mm Φ15.88 Φ15.88 Φ15.88 Φ19.05 Φ19.05 Φ19.05 Φ19.05
Max.Indoor Unit Connectable 13 16 19 23 26 26 Max.Indoor Unit Connectable 33 36 40 43 47 50 53
Noise Level dB(A) 62/54 64/55 64/56 65/57 66/58 66/57 Noise Level dB(A) 68/60 68/60 68/60 68/60 69/61 69/61 69/62
o o
Cooling Mode C -5~52* Cooling Mode C -5~52*
Operation Range o
Operation Range o
HeatingMode C -20~15 HeatingMode C -20~15
Max.Single piping length m 190 190 190 190 190 190 Max.Single piping length m 190 190 190 190 190 190 190

Height Between ODU&IDU m 50(40) 50(40) 50(40) 50(40) 50(40) 50(40) Height Between ODU&IDU m 50(40) 50(40) 50(40) 50(40) 50(40) 50(40) 50(40)
Difference Between IDUs m 15 15 15 15 15 15 Difference Between IDUs m 15 15 15 15 15 15 15

Notes: Notes:
1. Rated cooling capacity capacity is tested in the following conditions: 1. Rated cooling capacity capacity is tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height diference: 0m Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height diference: 0m
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene. 2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products. 3.The final appearance of outdoor units is subject to the actual products.
4.When the cooling operation temperature is over 52oC, please contact our professional engineer. 4.When the cooling operation temperature is over 52oC, please contact our professional engineer.
61/62
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

34HP 36/38/40/42HP 44/46/48HP 50/52HP

Hi-FLEXi X Series HP 34HP 36HP 38HP 40HP 42HP Hi-FLEXi X Series HP 44HP 46HP 48HP 50HP 52HP

Model Power Supply AC3Φ380~415V/50Hz AVWT-324UESZX AVWT-343UESZX AVWT-365UESZX AVWT-386UESZX AVWT-404UESZX Model Power Supply AC3Φ380~415V/50Hz AVWT-420UESZX AVWT-444UESZX AVWT-460UESZX AVWT-480UESZX AVWT-500UESZX
AVWT-96UESRX AVWT-114UESSX AVWT-114UESSX AVWT-114UESSX AVWT-114UESSX AVWT-114UESSX AVWT-136UESSX AVWT-154UESSX AVWT-114UESSX AVWT-114UESSX
Combination AVWT-114UESSX AVWT-114UESSX AVWT-114UESSX AVWT-114UESSX AVWT-136UESSX Combination AVWT-154UESSX AVWT-154UESSX AVWT-154UESSX AVWT-114UESSX AVWT-114UESSX
AVWT-114UESSX AVWT-114UESSX AVWT-136UESSX AVWT-154UESSX AVWT-154UESSX AVWT-154UESSX AVWT-154UESSX AVWT-154UESSX AVWT-114UESSX AVWT-136UESSX
kW 96.0 100.5 107.0 113.0 118.5 AVWT-136UESSX AVWT-136UESSX
Cooling Capacity
KBtu/h 327.6 342.9 365.1 385.6 404.3 kW 123.5 130.0 135.0 140.4 146.0
Cooling Operation Cooling Capacity
Power Consumption kW 24.45 25.71 28.19 30.3 32.78 KBtu/h 421.1 443.6 460.6 479 498.2
Cooling Operation
EER 3.93 3.91 3.80 3.73 3.62 Power Consumption kW 34.89 37.37 39.48 36.76 39.24
kW 106.5 112.5 120.0 125.0 132.5 EER 3.54 3.48 3.42 3.82 3.72
Heating Capacity
KBtu/h 363.5 384.0 409.5 426.6 452.1 kW 137.5 145.0 150.0 156.5 163.0
Heating Operation Heating Capacity
Power Consumption kW 25.39 26.67 28.86 30.25 32.44 KBtu/h 469.2 494.7 511.8 534.0 556.2
Heating Operation
COP 4.19 4.22 4.16 4.13 4.08 Power Consumption kW 33.83 36.02 37.41 37.75 39.94
Air Flow Rate m³/min 170+175+175 175+175+175 175+175+190 175+175+190 175+190+190 COP 4.06 4.03 4.01 4.15 4.08
Outer Dimension (H×W×D) mm 1,720×(950+1,210+1,210)×750 1,720×(1,210+1,210+1,210)×750 Air Flow Rate m³/min 175+190+190 190+190+190 190+190+190 175+175+175+190 175+175+190+190
Packing Dimension (H×W×D) mm Outer Dimension (H×W×D) mm 1,720×(1,210+1,210+1,210)×750 1,720×(1,210+1,210+1,210+1,210)×750
Net Weight Kg 197+224+224 224+224+224 224+224+227 224+224+247 224+227+247 Packing Dimension (H×W×D) mm
Gross Weight Kg 223+248+248 248+248+248 248+248+250 248+248+272 248+250+272 Net Weight Kg 224+247+247 227+247+247 247+247+247 224+224+224+227 224+224+227+227
Compressor Quantity 1+1+1 1+1+1 1+1+1 1+1+1 1+1+1 Gross Weight Kg 248+272+272 250+272+272 272+272+272 248+248+248+250 248+248+250+250
Condenser Fan Quantity 1+1+1 1+1+1 1+1+1 1+1+1 1+1+1 Compressor Quantity 1+1+1 1+1+1 1+1+1 1+1+1+1 1+1+1+1
Cabinet Color Ivory White Condenser Fan Quantity 1+1+1 1+1+1 1+1+1 1+1+1+1 1+1+1+1
Gas Line mm Φ31.75 Φ38.1 Φ38.1 Φ38.1 Φ38.1 Cabinet Color Ivory White
Refrigerant Piping
Liquid Line mm Φ19.05 Φ19.05 Φ19.05 Φ19.05 Φ19.05 Gas Line mm Φ38.1 Φ38.1 Φ38.1 Φ41.3 Φ41.3
Refrigerant Piping
Max.Indoor Unit Connectable 56 59 64 64 64 Liquid Line mm Φ19.05 Φ19.05 Φ19.05 Φ22.2 Φ22.2
Noise Level dB(A) 70/63 70/63 71/64 71/64 71/64 Max.Indoor Unit Connectable 64 64 64 64 64
Cooling Mode o
C -5~52* Noise Level dB(A) 72/65 72/65 72/65 73/66 73/66
Operation Range
HeatingMode o
C -20~15 Cooling Mode o
C -5~52*
Operation Range
Max.Single piping length m 190 190 190 190 190 HeatingMode o
C -20~15

Height Between ODU&IDU m 50(40) 50(40) 50(40) 50(40) 50(40) Max.Single piping length m 190 190 190 190 190
Difference Between IDUs m 15 15 15 15 15 Between ODU&IDU m 50(40) 50(40) 50(40) 50(40) 50(40)
Height
Difference Between IDUs m 15 15 15 15 15

Notes: Notes:
1. Rated cooling capacity capacity is tested in the following conditions: 1. Rated cooling capacity capacity is tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height diference: 0m Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height diference: 0m
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene. 2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products. 3.The final appearance of outdoor units is subject to the actual products.
4.When the cooling operation temperature is over 52oC, please contact our professional engineer. 4.For 4 modular combination please contact manufacture for special design.
5.When the cooling operation temperature is over 52oC, please contact our professional engineer.
63/64
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

54HP 56/58HP 60/62/64HP

Hi-FLEXi X Series HP 54HP 56HP 58HP Hi-FLEXi X Series HP 60HP 62HP 64HP

Model Power Supply AC3Φ380V~415V/50Hz AVWT-520UESZX AVWT-540UESZX AVWT-560UESZX Model Power Supply AC3Φ380V~415V/50Hz AVWT-580UESZX AVWT-600UESZX AVWT-620UESZX

AVWT-114UESSX AVWT-114UESSX AVWT-114UESSX AVWT-114UESSX AVWT-136UESSX AVWT-154UESSX


AVWT-114UESSX AVWT-114UESSX AVWT-136UESSX AVWT-154UESSX AVWT-154UESSX AVWT-154UESSX
Combination Combination
AVWT-136UESSX AVWT-154UESSX AVWT-154UESSX AVWT-154UESSX AVWT-154UESSX AVWT-154UESSX
AVWT-154UESSX AVWT-154UESSX AVWT-154UESSX AVWT-154UESSX AVWT-154UESSX AVWT-154UESSX
kW 151.5 157.0 163.5 kW 168.5 175.0 180.0
Cooling Capacity Cooling Capacity
KBtu/h 516.9 535.7 557.9 KBtu/h 574.9 597.1 614.2
Cooling Operation Cooling Operation
Power Consumption kW 41.35 43.46 45.94 Power Consumption kW 48.05 50.53 52.64
EER 3.66 3.61 3.56 EER 3.51 3.46 3.42
kW 169.0 175.0 182.5 kW 187.5 195.0 200.0
Heating Capacity Heating Capacity
KBtu/h 576.6 597.1 622.7 KBtu/h 639.8 665.3 682.4
Heating Opeartion Heating Operation
Power Consumption kW 41.33 42.72 44.91 Power Consumption kW 46.3 48.49 49.88
COP 4.09 4.10 4.06 COP 4.05 4.02 4.01
Air Flow Rate m³/min 175+175+190+190 175+175+190+190 175+190+190+190 Air Flow Rate m³/min 175+190+190+190 190+190+190+190 190+190+190+190
Outer Dimension (H×W×D) mm 1,720×(1,210+1,210+1,210+1,210)×750 1,720×(1,210+1,210+1,210+12,10)×750 Outer Dimension (H×W×D) mm 1,720×(1,210+1,210+1,210+1,210)×750
Packing Dimension (H×W×D) mm - - - Packing Dimension (H×W×D) mm - - -
Net Weight Kg 224+224+227+247 224+224+247+247 224+227+247+247 Net Weight Kg 224+247+247+247 227+247+247+247 247+247+247+247
Gross Weight Kg 248+248+250+272 248+248+272+272 248+250+272+272 Gross Weight Kg 248+272+272+272 250+272+272+272 272+272+272+272
Compressor Quantity 1+1+1+1 1+1+1+1 1+1+1+1 Compressor Quantity 1+1+1+1 1+1+1+1 1+1+1+1
Condenser Fan Quantity 1+1+1+1 1+1+1+1 1+1+1+1 Condenser Fan Quantity 1+1+1+1 1+1+1+1 1+1+1+1
Cabinet Color Ivory White Cabinet Color Ivory White
Gas Line mm Φ41.3 Φ41.3 Φ44.5 Gas Line mm Φ44.5 Φ44.5 Φ44.5
Refrigerant Piping Refrigerant Piping
Liquid Line mm Φ22.2 Φ22.2 Φ22.2 Liquid Line mm Φ22.2 Φ22.2 Φ22.2
Max.Indoor Unit Connectable 64 64 64 Max.Indoor Unit Connectable 64 64 64
Noise Level dB(A) 73/66 73/66 74/67 Noise Level dB(A) 74/67 74/67 74/67
o
Cooling Mode o
C -5~52* Cooling Mode C -5~52*
Operation Range Operation Range o
HeatingMode o
C -20~15 HeatingMode C -20~15
Max.Single piping length m 190 190 190 Max.Single piping length m 190 190 190

Height Between ODU&IDU m 50(40) 50(40) 50(40) Height Between ODU&IDU m 50(40) 50(40) 50(40)
Difference Between IDUs m 15 15 15 Difference Between IDUs m 15 15 15

Notes: Notes:
1. Rated cooling capacity capacity is tested in the following conditions: 1. Rated cooling capacity capacity is tested in the following conditions:
Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height diference: 0m Cooling conditions: indoor air inlet temperature: 27oC DB 19oC WB, Outdoor air inlet temperature: 35oC DB, pipe length : 7.5m, pipe height diference: 0m
2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene. 2.The above noise values are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo must be included at the scene.
3.The final appearance of outdoor units is subject to the actual products. 3.The final appearance of outdoor units is subject to the actual products.
4.For 4 modular combination please contact manufacture for special design. 4.For 4 modular combination please contact manufacture for special design.
5.When the cooling operation temperature is over 52oC, please contact our professional engineer. 5.When the cooling operation temperature is over 52oC, please contact our professional engineer.
65/66
OUTDOOR UNIT Product Line

Cooling Domination Mode


Hi-FLEXi R Series

Hisense Hi-FLEXi R Series heat recovery air conditioning systems


can realize simultaneous cooling and heating operation within
one refrigerating system, which not only contributes to energy
conservation but also meets various requirements of different
consumers.

High efficiency scroll compressor


Simultaneous cooling and heating
Lastest inverter control technology
Intelligent control system
Heat Recovery

When total indoor heating load is less than cooling load,heat is being transferred from cooling room to heating
room,part of heat exchanger is used as condenser to exhaust the redundant heat.

Heating Domination Mode

Exterior Zone of Building

Meeting various requirements of customers who are sensitive to temperature and diverse space with different
function from the perspective of humanity especially at the transition season, like the complex of equipment
rooms and offices, or the guest rooms and dining hall in the same hotel etc.
The latest heat recovery multi-split system make season indoor units work in cooling and heating at the same
time and being switched between two modes individually,which flexibly satisfies personalized need of different
When total indoor heating load is more than cooling load,heat is being transferred from cooling room to heating
users. room,part of heat exchanger is used as evaporator to compensate the required heat.
67/68
OUTDOOR UNIT Product Line

Cooling/Heating Equilibrium Mode Extra-high External Static Pressure Design

Max. 60Pa

Adopt high-efficiency DC fan motor


Max. 60Pa
The use of high-efficiency fan reduces energy consumption
of the motor
Can achieve industry-leading level of external static
pressure 60Pa

The efficient axial fan is designed adopting CFD, finite element method, aviation dynamic fluid simulation analysis and
If the ratio of cooling Load and heating load is 50:50,almost other advanced concepts; its air inlet angle and outlet angle are optimized; together with unique horn air vent design, the
all the heat is moving among indoor units external static pressure of outdoor unit is higher, which can better exhaust air and ensure smooth air flow.

Layered Installation, Flexibly Corresponding to High-rise Buildings


Configuration of Heat Recovery Operation System
For high-rise buildings, crawl space can be left to place outdoor units, or machine room can be set up on each floor. By
using exhaust duct to exhaust the air, short circuit of return air can be avoided with long exhaust distance, which ensures
Hi-FLEXi R Series heat recovery operation system is composed of heat recovery outdoor unit, indoor unit, switch box,
good ventilation and heat exchange effects of outdoor units.
branch pipes and refrigerant pipes. One switch box unit could connect to one or multiple indoor units. The indoor units
equipped with a same switch box unit will keep the same operation mode.

Temperature ℃
46.9443

45.4512

43.9582

42.4651
40.9721

39.4790

37.9859

36.4929
34.9998

Airflow Schematic Exhaust duct installation Layered installation effect picture


69/70
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

8/10/12HP 14/16/18HP 20HP 22/24/26HP

Hi-FLEXi R Series HP 8HP 10HP 12HP 14HP 16HP 18HP Hi-FLEXi R Series HP 20HP 22HP 24HP 26HP
AC3Φ380~415V/50Hz AVWT-76FESR AVWT-96FESR AVWT-114FESR AVWT-136FESS AVWT-154FESS AVWT-170FESS AC3Φ380~415V/50Hz AVWT-190FESZ AVWT-212FESZ AVWT-232FESZ AVWT-250FESZ
Model Power Supply AC3Φ380V/60Hz AVWT-76F7SR AVWT-96F7SR AVWT-114F7SR AVWT-136F7SS AVWT-154F7SS AVWT-170F7SS Model Power Supply AC3Φ380V/60Hz AVWT-190F7SZ AVWT-212F7SZ AVWT-232F7SZ AVWT-250F7SZ
AC3Φ220V/60Hz AVWT-76F9SR AVWT-96F9SR AVWT-114F9SR AVWT-136F9SS AVWT-154F9SS AVWT-170F9SS AC3Φ220V/60Hz AVWT-190F9SZ AVWT-212F9SZ AVWT-232F9SZ AVWT-250F9SZ
Combination AVWT-76FESR AVWT-76FESR AVWT-96FESR AVWT-114FESR
Combination AVWT-136FESS
AVWT-114FESR AVWT-136FESS AVWT-136FESS
kW 22.4 28.0 33.5 40.0 45.0 50.0
Nominal Capacity kW 56.0 61.5 73.0
KBtu/h 76.5 95.5 114.3 136.5 153.5 170.6 69.0
Nominal Capacity
Cooling Operation KBtu/h 190.8 250.8
kW 5.65 7.65 10.18 12.25 13.74 16.60 213.0 232.0
Power Consumption Cooling Operation
Power Consumption kW 15.83 17.90 19.90 22.43
EER 3.96 3.66 3.29 3.27 3.28 3.01
EER 3.54 3.44 3.47 3.25
kW 25.0 31.5 37.5 45.0 50.0 56.0
Nominal Capacity kW 63.0 69.0 82.5
KBtu/h 85.3 107.5 128.0 153.5 170.6 191.1 77.5
Nominal Capacity
Heating Operation KBtu/h 213.3 239.0 281.5
Power Consumption kW 5.81 7.76 10.12 11.30 12.60 15.30 261.0
Heating Operation
COP 4.30 4.06 3.71 3.98 3.97 3.66 Power Consumption kW 15.93 17.11 19.06 21.42
COP 3.95 4.03 4.07 3.85
Air Flow Rate m³/h 9,300 10,200 10,500 11,700 11,700 11,700
Air Flow Rate m³/h 19,800 21,000 21,900 22,200
Outer Dimensions (H×W×D) mm 1,720×950×750 1,720×950×750 1,720×950×750 1,720×1,210×750 1,720×1,210×750 1,720×1,210×750
Outer Dimensions (H×W×D) mm 1,720×(950+950)×750 1,720×(950+1,210)×750 1,720×(950+1,210)×750 1,720×(950+1,210)×750
Packing Dimension (H×W×D) mm 1,828×1,018×824 1,828×1,018×824 1,828×1,018×824 1,882×1,278×824 1,882×1,278×824 1,882×1,278×824
Packing Dimension (H×W×D) mm --- --- --- ---
Net Weight Kg 225 227 246 298 312 318
Net Weight Kg 225+246 225+298 227+298 246+298
Gross Weight Kg 235 237 255 310 325 330
Gross Weight Kg 235+255 235+310 237+310 255+310
Compressor Quantity 1 1 1 2 2 2
Compressor Quantity 2 3 3 3
Condenser Fan Quantity 1 1 1 1 1 1
Condenser Fan Quantity 2 2 2 2
Cabinet Color Ivory White
Gas Line Cabinet Color Ivory White
Heat Pump mm Ф19.05 Ф22.2 Ф25.4 Ф25.4 Ф28.6 Ф28.6
Operation System Heat Pump Gas Line mm Ф28.6 Ф28.6 Ф28.6 Ф31.75
Liquid Line mm Ф9.53 Ф9.53 Ф12.7 Ф12.7 Ф12.7 Ф15.88
Operation System Liquid Line mm Ф15.88 Ф15.88 Ф19.05
Liquid Line mm Ф9.53 Ф9.53 Ф12.7 Ф12.7 Ф12.7 Ф15.88 Ф15.88
Heat Recovery Liquid Line mm Ф15.88 Ф15.88 Ф19.05
Low Pressure Gas Line mm Ф19.05 Ф22.2 Ф25.4 Ф25.4 Ф28.6 Ф28.6 Ф15.88
Operation System Heat Recovery
Operation System Low Pressure Gas Line mm Ф28.6 Ф28.6 Ф28.6 Ф31.75
High Pressure Gas Line mm Ф15.88 Ф19.05 Ф22.2 Ф22.2 Ф22.2 Ф22.2
High Pressure Gas Line mm Ф22.2 Ф25.4 Ф25.4 Ф25.4
Max. Connectable No. of Indoor Units 13.0 16.0 19.0 23.0 26.0 26.0
Max. Connectable No. of Indoor Units 33.0 36.0 40.0 43.0
Max. Piping Length m 165(190*) 165(190*) 165(190*) 165(190*) 165(190*) 165(190*)
Max. Piping Length m 165(190*) 165(190*) 165(190*) 165(190*)
Between ODU and IDU m 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*)
Height Difference Between ODU and IDU m 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*)
Between IDUs m 15(30*) 15(30*) 15(30*) 15(30*) 15(30*) 15(30*) Height Difference
Between IDUs m 15(30*) 15(30*) 15(30*) 15(30*)
Noise Level dB(A) 58 58 60 62 62 63
Noise Level dB(A) 62 63 63 64
Cooling o
C DB -5~48
Operation Range Cooling o
C DB -5~48
Heating o
C WB -20~15.5 Operation Range
Heating o
C WB -20~15.5

NOTES: NOTES:
1. The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure is based on the following conditions.1 Meter from the unit service 1. The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure is based on the following conditions.1 Meter from the unit service
Cooling Operation Conditions cover surface, and 1.5 Meter from floor level. The above data is based on the cooling Cooling Operation Conditions cover surface, and 1.5 Meter from floor level. The above data is based on the cooling
Indoor Air Inlet Temperature: 27oC DB(80°F DB), 19.0oC WB(66.2°F WB) mode. In case of heating mode, the sound pressure level increases by approximately Indoor Air Inlet Temperature: 27oC DB(80°F DB), 19.0oC WB(66.2°F WB) mode. In case of heating mode, the sound pressure level increases by approximately
Outdoor Air Inlet Temperature: 35oC DB(95°F DB) 1~2dB. The above data was measured in an anechoic chamber so that reflected sound Outdoor Air Inlet Temperature: 35oC DB(95°F DB) 1~2dB. The above data was measured in an anechoic chamber so that reflected sound
should be taken into consideration in the field. should be taken into consideration in the field.
Piping Length: 7.5 Meters Piping Lift: 0 Meter Piping Length: 7.5 Meters Piping Lift: 0 Meter
3. Except for the specified combination in the table, there is no other combination of the base unit. 3. Except for the specified combination in the table, there is no other combination of the base unit.
Heating Operation Conditions 4. The width of outer dimension, it is the value when each distance between the base outdoor Heating Operation Conditions 4. The width of outer dimension, it is the value when each distance between the base outdoor
Indoor Air Inlet Temperature: 20oC DB(68°F DB), units is specified to 20mm. Indoor Air Inlet Temperature: 20oC DB(68°F DB), units is specified to 20mm.
Outdoor Air Inlet Temperature: 7oC DB(45°F DB), 6oC WB(43°F WB) 5. For Max. pipe length more than 165m, height difference between outdoor Outdoor Air Inlet Temperature: 7oC DB(45°F DB), 6oC WB(43°F WB) 5. For Max. pipe length more than 165m, height difference between outdoor
unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units
(IDUs) more than 15m, please contact our professional engineer. (IDUs) more than 15m, please contact our professional engineer.
71/72
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

28/30/32/34/36HP 38/40/42HP

Hi-FLEXi R Series HP 28HP 30HP 32HP 34HP 36HP Hi-FLEXi R Series HP 38HP 40HP 42HP
AC3Φ380~415V/50Hz AVWT-272FESZ AVWT-290FESZ AVWT-308FESZ AVWT-324FESZ AVWT-340FESZ AC3Φ380~415V/50Hz AVWT-364FESZ AVWT-382FESZ AVWT-398FESZ

Model Power Supply AC3Φ380V/60Hz AVWT-272F7SZ AVWT-290F7SZ AVWT-308F7SZ AVWT-324F7SZ AVWT-340F7SZ AC3Φ380V/60Hz AVWT-364F7SZ AVWT-382F7SZ AVWT-398F7SZ
Model Power Supply
AC3Φ220V/60Hz AVWT-272F9SZ AVWT-290F9SZ AVWT-308F9SZ AVWT-324F9SZ AVWT-340F9SZ AC3Φ220V/60Hz AVWT-364F9SZ AVWT-382F9SZ AVWT-398F9SZ

Combination AVWT-136FESS AVWT-136FESS AVWT-154FESS AVWT-154FESS AVWT-170FESS Combination AVWT-114FESR AVWT-114FESR AVWT-114FESR
AVWT-136FESS AVWT-154FESS AVWT-154FESS AVWT-170FESS AVWT-170FESS AVWT-114FESR AVWT-114FESR AVWT-114FESR
AVWT-136FESS AVWT-154FESS AVWT-170FESS
kW 80.0 85.0 90.0 95.0 100.0
Nominal Capacity kW 109.0 112.0 118.0
KBtu/h 273.0 290.0 307.0 324.1 341.2 Nominal Capacity
Cooling Operation KBtu/h 365.1 382.1 399.2
kW Cooling Operation
Power Consumption 24.50 25.99 27.48 30.34 33.20
Power Consumption kW 32.61 34.10 36.96
EER 3.27 3.27 3.28 3.13 3.01 EER 3.34 3.28 3.19
kW 90.0 95.0 100.0 106.0 112.0 118.0 125.0 132.0
Nominal Capacity kW
KBtu/h Nominal Capacity
307.1 324.1 341.2 361.7 382.1 KBtu/h 409.5 426.5 447.5
Heating Operation Heating Operation
Power Consumption kW 22.60 23.90 25.20 27.90 30.60 Power Consumption kW 31.54 32.84 35.54
COP 3.98 3.97 3.97 3.80 3.66 COP 3.74 3.81 3.71
Air Flow Rate m³/h 23,400 23,400 23,400 23,400 23,400 Air Flow Rate m³/h 32,700 32,700 32,700
Outer Dimensions (H×W×D) mm 1,720×(1,210+1,210)×750 1,720×(1,210+1,210)×750 1,720×(1,210+1,210)×750 1,720×(1,210+1,210)×750 1,720×(1,210+1,210)×750 Outer Dimensions (H×W×D) mm 1,720×(950+950+1,210)×750 1,720×(950+950+1,210)×750 1,720×(950+950+1,210)×750
Packing Dimension (H×W×D) mm --- --- --- --- --- Packing Dimension (H×W×D) mm --- --- ---
Net Weight Kg 298+298 298+312 312+312 312+318 318+318 Net Weight Kg 246+246+298 246+246+312 246+246+318
Gross Weight Kg 310+310 310+325 325+325 325+330 330+330 Gross Weight Kg 255+255+310 255+255+325 255+255+330
Compressor Quantity 4 4 4 4 4 Compressor Quantity 4 4 4
Condenser Fan Quantity 2 2 2 2 2 Condenser Fan Quantity 3 3 3
Cabinet Color Ivory White Cabinet Color Ivory White

Heat Pump Gas Line mm Ф31.75 Ф31.75 Ф31.75 Ф31.75 Ф38.1 Heat Pump Gas Line mm Ф38.1 Ф38.1 Ф38.1
Operation System Liquid Line mm Ф19.05 Ф19.05 Ф19.05 Ф19.05 Ф19.05 Operation System Liquid Line mm Ф19.05 Ф19.05 Ф19.05
Liquid Line mm Ф19.05 Ф19.05 Ф19.05 Ф19.05 Ф19.05 Liquid Line mm Ф19.05 Ф19.05 Ф19.05
Heat Recovery Heat Recovery
Low Pressure Gas Line mm Ф31.75 Ф31.75 Ф31.75 Ф31.75 Ф31.75 Operation System Low Pressure Gas Line mm Ф38.1 Ф38.1 Ф38.1
Operation System
High Pressure Gas Line mm Ф28.6 Ф28.6 Ф28.6 Ф28.6 Ф28.6 High Pressure Gas Line mm Ф31.75 Ф31.75 Ф31.75

Max. Connectable No. of Indoor Units 47.0 50.0 53.0 56.0 59.0 Max. Connectable No. of Indoor Units 64.0 64.0 64.0

Max. Piping Length m 165(190*) 165(190*) 165(190*) 165(190*) 165(190*) Max. Piping Length m 165(190*) 165(190*) 165(190*)

Between ODU and IDU m 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*)


Between ODU and IDU m 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*)
Height Difference Height Difference
Between IDUs m Between IDUs m 15(30*) 15(30*) 15(30*)
15(30*) 15(30*) 15(30*) 15(30*) 15(30*)
Noise Level Noise Level dB(A) 66 66 66
dB(A) 65 65 65 66 66
Cooling o Cooling o
C DB -5~48
C DB -5~48 Operation Range
Operation Range Heating o
C WB -20~15.5
Heating o
C WB -20~15.5

NOTES: NOTES:
1. The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure is based on the following conditions.1 Meter from the unit service 1. The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure is based on the following conditions.1 Meter from the unit service
Cooling Operation Conditions cover surface, and 1.5 Meter from floor level. The above data is based on the cooling Cooling Operation Conditions cover surface, and 1.5 Meter from floor level. The above data is based on the cooling
Indoor Air Inlet Temperature: 27oC DB(80°F DB), 19.0oC WB(66.2°F WB) mode. In case of heating mode, the sound pressure level increases by approximately Indoor Air Inlet Temperature: 27oC DB(80°F DB), 19.0oC WB(66.2°F WB) mode. In case of heating mode, the sound pressure level increases by approximately
Outdoor Air Inlet Temperature: 35oC DB(95°F DB) 1~2dB. The above data was measured in an anechoic chamber so that reflected sound Outdoor Air Inlet Temperature: 35oC DB(95°F DB) 1~2dB. The above data was measured in an anechoic chamber so that reflected sound
should be taken into consideration in the field. should be taken into consideration in the field.
Piping Length: 7.5 Meters Piping Lift: 0 Meter Piping Length: 7.5 Meters Piping Lift: 0 Meter
3. Except for the specified combination in the table, there is no other combination of the base unit. 3. Except for the specified combination in the table, there is no other combination of the base unit.
Heating Operation Conditions 4. The width of outer dimension, it is the value when each distance between the base outdoor Heating Operation Conditions 4. The width of outer dimension, it is the value when each distance between the base outdoor
Indoor Air Inlet Temperature: 20oC DB(68°F DB), units is specified to 20mm. Indoor Air Inlet Temperature: 20oC DB(68°F DB), units is specified to 20mm.
Outdoor Air Inlet Temperature: 7oC DB(45°F DB), 6oC WB(43°F WB) 5. For Max. pipe length more than 165m, height difference between outdoor Outdoor Air Inlet Temperature: 7oC DB(45°F DB), 6oC WB(43°F WB) 5. For Max. pipe length more than 165m, height difference between outdoor
unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units
(IDUs) more than 15m, please contact our professional engineer. (IDUs) more than 15m, please contact our professional engineer.
73/74
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

44/46/48HP 50/52/54HP

Hi-FLEXi R Series HP 44HP 46HP 48HP Hi-FLEXi R Series HP 50HP 52HP 54HP
AC3Φ380~415V/50Hz AVWT-420FESZ AVWT-438FESZ AVWT-454FESZ AC3Φ380~415V/50Hz AVWT-476FESZ AVWT-494FESZ AVWT-510FESZ

AC3Φ380V/60Hz AVWT-420F7SZ AVWT-438F7SZ AVWT-454F7SZ AC3Φ380V/60Hz AVWT-476F7SZ AVWT-494F7SZ AVWT-510F7SZ


Model Power Supply Model Power Supply
AC3Φ220V/60Hz AVWT-420F9SZ AVWT-438F9SZ AVWT-454F9SZ AC3Φ220V/60Hz AVWT-476F9SZ AVWT-494F9SZ AVWT-510F9SZ
Combination AVWT-114FESR AVWT-114FESR AVWT-114FESR Combination AVWT-136FESS AVWT-154FESS AVWT-170FESS
AVWT-136FESS AVWT-154FESS AVWT-170FESS AVWT-170FESS AVWT-170FESS AVWT-170FESS
AVWT-170FESS AVWT-170FESS AVWT-170FESS AVWT-170FESS AVWT-170FESS AVWT-170FESS
kW 125.0 132.0 136.0 kW 140.0 145.0 150.0
Nominal Capacity Nominal Capacity
KBtu/h 421.4 438.4 455.5 KBtu/h 477.7 494.7 511.8
Cooling Operation Cooling Operation
Power Consumption kW 39.03 40.52 43.38 Power Consumption kW 45.45 46.94 49.80
EER 3.20 3.26 3.14 EER 3.08 3.09 3.01

kW 140.0 145.0 150.0 kW 155.0 160.0 165.0


Nominal Capacity Nominal Capacity
KBtu/h 472.6 494.7 511.8 KBtu/h 528.9 545.9 563.0
Heating Operationn Heating Operation
Power Consumption kW 36.72 38.02 40.72 Power Consumption kW 41.90 43.20 45.90
COP 3.81 3.81 3.68 COP 3.70 3.70 3.59
Air Flow Rate m³/h 33,900 33,900 33,900 Air Flow Rate m³/h 35,100 35,100 35,100
Outer Dimensions (H×W×D) mm 1,720×(950+1,210+1,210)×750 1,720×(950+1,210+1,210)×750 1,720×(950+1,210+1,210)×750 Outer Dimensions (H×W×D) mm (1,720×1,210×750)×3 (1,720×1,210×750)×3 (1,720×1,210×750)×3
Packing Dimension (H×W×D) mm --- --- --- Packing Dimension (H×W×D) mm --- --- ---
Net Weight Kg 246+298+318 246+312+318 246+318+318 Net Weight Kg 298+318+318 312+318+318 318+318+318
Gross Weight Kg 255+310+330 255+325+330 255+330+330 Gross Weight Kg 310+330+330 325+330+330 330+330+330
Compressor Quantity 5 5 5 Compressor Quantity 6 6 6
Condenser Fan Quantity 3 3 3 Condenser Fan Quantity 3 3 3
Cabinet Color Ivory White Cabinet Color Ivory White

Heat Pump Gas Line mm Ф38.1 Ф38.1 Ф38.1 Heat Pump Gas Line mm Ф38.1 Ф38.1 Ф38.1
Operation System Liquid Line mm Ф19.05 Ф19.05 Ф19.05 Operation System Liquid Line mm Ф19.05 Ф19.05 Ф19.05
Liquid Line mm Ф19.05 Ф19.05 Ф19.05 Liquid Line mm Ф19.05 Ф19.05 Ф19.05
Heat Recovery Heat Recovery
Operation System Low Pressure Gas Line mm Ф38.1 Ф38.1 Ф38.1 Operation System Low Pressure Gas Line mm Ф38.1 Ф38.1 Ф38.1
High Pressure Gas Line mm Ф31.75 Ф31.75 Ф31.75 High Pressure Gas Line mm Ф31.75 Ф31.75 Ф31.75
Max. Connectable No. of Indoor Units 64.0 64.0 64.0 Max. Connectable No. of Indoor Units 64.0 64.0 64.0
Max. Piping Length m 165(190*) 165(190*) 165(190*) Max. Piping Length m 165(190*) 165(190*) 165(190*)
Between ODU and IDU m 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*) Between ODU and IDU m 50(90*)/40(90*) 50(90*)/40(90*) 50(90*)/40(90*)
Height Difference Height Difference
Between IDUs m 15(30*) 15(30*) 15(30*) Between IDUs m 15(30*) 15(30*) 15(30*)
Noise Level dB(A) 67 67 67 Noise Level dB(A) 67 67 68
Cooling o
C DB -5~48 Cooling o
C DB -5~48
Operation Range Operation Range
Heating o
C WB -20~15.5 Heating o
C WB -20~15.5

NOTES: NOTES:
1. The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure is based on the following conditions.1 Meter from the unit service 1. The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure is based on the following conditions.1 Meter from the unit service
Cooling Operation Conditions cover surface, and 1.5 Meter from floor level. The above data is based on the cooling Cooling Operation Conditions cover surface, and 1.5 Meter from floor level. The above data is based on the cooling
Indoor Air Inlet Temperature: 27oC DB(80°F DB), 19.0oC WB(66.2°F WB) mode. In case of heating mode, the sound pressure level increases by approximately Indoor Air Inlet Temperature: 27oC DB(80°F DB), 19.0oC WB(66.2°F WB) mode. In case of heating mode, the sound pressure level increases by approximately
Outdoor Air Inlet Temperature: 35oC DB(95°F DB) 1~2dB. The above data was measured in an anechoic chamber so that reflected sound Outdoor Air Inlet Temperature: 35oC DB(95°F DB) 1~2dB. The above data was measured in an anechoic chamber so that reflected sound
should be taken into consideration in the field. should be taken into consideration in the field.
Piping Length: 7.5 Meters Piping Lift: 0 Meter 3. Except for the specified combination in the table, there is no other combination of the base unit. Piping Length: 7.5 Meters Piping Lift: 0 Meter
3. Except for the specified combination in the table, there is no other combination of the base unit.
Heating Operation Conditions 4. The width of outer dimension, it is the value when each distance between the base outdoor Heating Operation Conditions 4. The width of outer dimension, it is the value when each distance between the base outdoor
Indoor Air Inlet Temperature: 20oC DB(68°F DB), units is specified to 20mm. Indoor Air Inlet Temperature: 20oC DB(68°F DB), units is specified to 20mm.
Outdoor Air Inlet Temperature: 7oC DB(45°F DB), 6oC WB(43°F WB) 5. For Max. pipe length more than 165m, height difference between outdoor Outdoor Air Inlet Temperature: 7oC DB(45°F DB), 6oC WB(43°F WB) 5. For Max. pipe length more than 165m, height difference between outdoor
unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units unit(ODU)&indoor unit(IDU) more than 50(40)m or height difference between indoor units
(IDUs) more than 15m, please contact our professional engineer. (IDUs) more than 15m, please contact our professional engineer.
75/76
OUTDOOR UNIT Product Line

Indoor Installation, Not affected by weather conditions


Hi-FLEXi
Heat Recovery
W Series
It is invisible from the outside,ensure the beautiful facade of the building.
It is very suitable for sound sensitive areas because there is no external
running sound.
Hi-FLEXi W Series Heat Recovery can keep simultaneous It can operation normally even in the most extreme outside conditions,
cooling and heating from one system. And it has a new especially in geothermal operation.
switch box, which is designed to improve energy efficiency.
It has very high efficiency thanks to water cooled condenser.
The products are more flexible to meet users' demands.
Indoor installation is more convenient and safer.
Simultaneous Cooling and Heating
Convenient Installation
360° Fitted Refrigerant Cooling Technology

2-stage Heat Recovery


Simplify Installation Process
With 2-stage heat recovery from both refrigerant side and water source side, the heat recovery system realize energy
saving at the greatest extent. Simultaneous cooling and heating in one system could be achieved.

There is no need for ventilation in equipment


Heat recovery between indoor units Heat recovery between outdoor units
room.
Heat exhausted from indoor unit in cooling mode The outdoor unit of cooling mode exhaust heat Save time and simplify installation process
could be transferred to the units which is in into water , and the other outdoor unit of heating because there is no need for installing air duct
heating mode. mode absorb heat from water. So the heat for water source outdoor unit.
recovery between outdoor units could be achieved
via the water pipe .

Continuously Heating Without Defrosting Operation


Heat Exhaust

Best comfort because of no


Heat Exhaust

temperature fluctuations during


heating operation.
Heat Suction
Continuously heating thanks to no
defrosting during heating operation.

Heat Exhaust
77/78
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

Hi-FLEXi W Series Heat Recovery HP 8HP 10HP 12HP 14HP Hi-FLEXi W Series Heat Recovery HP 16HP 18HP 20HP
Model Power Supply AC 3Ф, 380 ~ 415V/50Hz(60Hz) AVWW-76FKFW AVWW-96FKFW AVWW-114FKFW AVWW-136FKFW Model Power Supply AC 3Ф, 380 ~ 415V/50Hz(60Hz) AVWW-154FKFW AVWW-170FKFW AVWW-190FKFW

kW 22.4 28.0 33.5 40.0 kW 45.0 50.0 56.0


Nominal Capacity*1 Nominal Capacity*1
KBtu/h 76.5 95.6 114.3 136.5 KBtu/h 153.6 170.6 191.1
Cooling Operation Cooling Operation
Nominal Input kW 3.85 5.04 6.32 7.84 Nominal Input kW 8.11 9.43 10.98
EER 5.82 5.55 5.30 5.10 EER 5.55 5.30 5.10
kW 25.0 31.5 37.5 45.0 kW 50.0 56.0 63.0
Nominal Capacity*1 Nominal Capacity*1
KBtu/h 85.3 107.5 128.0 153.6 KBtu/h 170.6 191.1 215.0
Heating Operation Heating Operation
Nominal Input kW 4.08 5.25 6.45 8.03 Nominal Input kW 8.33 9.62 10.86
COP 6.12 6.00 5.81 5.60 COP 6.00 5.82 5.80
Height mm 1030 1030 1030 1030 Height mm 1030 1030 1030
Width mm 820 820 820 820 Width mm 1040 1040 1040
Outer Dimensions Outer Dimensions
Depth mm 560 560 560 560 Depth mm 560 560 560
Area m² 0.46 0.46 0.46 0.46 Area m² 0.58 0.58 0.58
Packing Dimensions H×W×D mm 1180×900×632 1180×900×632 1180×900×632 1180×900×632 Packing Dimensions H×W×D mm 1180×1112×632 1180×1112×632 1180×1112×632
Net Weight Kg 166 166 171 171 Net Weight Kg 245 246 246
Gross Weight Kg 170 170 175 175 Gross Weight Kg 250 251 251
Sound Pressure Level *2 Cooling/Heating dB(A) 49/51 51/53 53/54 55/57 Sound Pressure Level *2 Cooling/Heating dB(A) 51/52 53/53 53/55
Water Temperature*3 °C 10~45 10~45 10~45 10~45 Water Temperature*3 °C 10~45 10~45 10~45
Water Flow Rate L/min 76.7 96.0 115.0 138.3 Water Flow Rate L/min 153.3 166.7 193.3
Water-Side Water-Side
Heat Exchanger Water Pressure Drop kPa 30 45 45 60 Heat Exchanger Water Pressure Drop kPa 40 45 60
Maximum Pressure Resistance kgf/cm2 20 20 20 20 Maximum Pressure Resistance kgf/cm2 20 20 20
Liquid Pipe mm Ф9.53 Ф9.53 Ф12.7 Ф12.7 Liquid Pipe mm Ф12.7 Ф15.88 Ф15.88
Refrigerant Refrigerant
Connecting Pipes Low Pressure Gas Pipe mm Ф19.05 Ф22.2 Ф25.4 Ф25.4 Connecting Pipes Low Pressure Gas Pipe mm Ф28.6 Ф28.6 Ф28.6
High/Low Pressure Gas Pipe mm Ф15.88 Ф19.05 Ф22.2 Ф22.2 High/Low Pressure Gas Pipe mm Ф22.2 Ф22.2 Ф22.2
Water Pipe DN32 DN32 DN32 DN32 Water Pipe DN32 DN32 DN32
Water Water
Thread of Connector G1-1/4B G1-1/4B G1-1/4B G1-1/4B Thread of Connector G1-1/4B G1-1/4B G1-1/4B
Connecting Pipes Connecting Pipes
Drain Pipe mm Outer Diameter 18 Outer Diameter 18 Outer Diameter 18 Outer Diameter 18 Drain Pipe mm Outer Diameter 18 Outer Diameter 18 Outer Diameter 18
Recommended 12 15 18 21 Recommended 23 26 29
MAX. Connectable MAX. Connectable
Indoor Units MAX. 19 24 29 34 Indoor Units MAX. 39 43 48
MAX. Piping Length*4 m 300(500) 300(500) 300(500) 300(500) MAX. Piping Length*4 m 300(500) 300(500) 300(500)

NOTES:
*1. Operation Condition:
Cooling:Indoor Temperature 27oC DB/19oC WB, Water Inlet/Outlet 30/35oC.
Heating:Indoor Temperature 20oC DB/15oC WB, Water Inlet 20oC.
*2. The sound pressure is based on the following conditions.
1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
*3. When unit is operating out of the allowable water temperature range, it won't strat normally and will alarm.
*4. For Max.pipe length more than 300m, please contact our professional engineer.
79/80
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

Hi-FLEXi W Series Heat Recovery HP 22HP 24HP 26HP 28HP 30HP Hi-FLEXi W Series Heat Recovery HP 32HP 34HP 36HP 38HP 40HP
Model Power Supply AC 3Ф, 380 ~ 415V/50Hz(60Hz) AVWW-210FKFW AVWW-228FKFW AVWW-250FKFW AVWW-268FKFW AVWW-286FKFW Model Power Supply AC 3Ф, 380 ~ 415V/50Hz(60Hz) AVWW-304FKFW AVWW-326FKFW AVWW-344FKFW AVWW-360FKFW AVWW-380FKFW
AVWW-96FKFW AVWW-114FKFW AVWW-114FKFW AVWW-114FKFW AVWW-96FKFW AVWW-114FKFW AVWW-136FKFW AVWW-154FKFW AVWW-170FKFW AVWW-190FKFW
Combination Combination
AVWW-114FKFW AVWW-114FKFW AVWW-136FKFW AVWW-154FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW
kW 61.5 67.0 73.5 78.5 84.0 kW 89.5 96.0 101.0 106.0 112.0
Nominal Capacity*1 Nominal Capacity*1
KBtu/h 209.9 228.6 250.8 267.9 286.7 KBtu/h 305.4 327.6 344.7 361.7 382.1
Cooling Operation Cooling Operation
Nominal Input kW 11.4 12.6 14.2 14.4 16.0 Nominal Input kW 17.3 18.8 19.1 20.4 22.0
EER 5.41 5.30 5.19 5.44 5.24 EER 5.17 5.10 5.29 5.19 5.10
kW 69.0 75.0 82.5 87.5 94.5 kW 100.5 108.0 113.0 119.0 126.0
Nominal Capacity*1 Nominal Capacity*1
KBtu/h 235.4 255.9 281.6 298.6 322.4 KBtu/h 342.9 368.6 385.6 406.0 429.9
Heating Operation Heating Operation
Nominal Input kW 11.7 12.9 14.5 14.8 16.1 Nominal Input kW 17.3 18.9 19.2 20.5 21.7
COP 5.90 5.81 5.70 5.92 5.87 COP 5.81 5.72 5.89 5.81 5.80

H×W×D mm 1030×820×560+ 1030×820×560+ 1030×820×560+ 1030×820×560+ 1030×820×560+ H×W×D mm 1030×820×560+ 1030×820×560+ 1030×1040×560+ 1030×1040×560+ 1030×1040×560+
Outer Dimensions 1030×820×560 1030×820×560 1030×820×560 1030×1040×560 1030×1040×560 Outer Dimensions 1030×1040×560 1030×1040×560 1030×1040×560 1030×1040×560 1030×1040×560
Area m² 0.9 0.9 0.9 1.0 1.0 Area m² 1.0 1.0 1.2 1.2 1.2

Packing Dimensions 1180×900×632+ 1180×900×632+ 1180×900×632+ 1180×900×632+ 1180×900×632+ Packing Dimensions 1180×900×632+ 1180×900×632+ 1180×1112×632+ 1180×1112×632+ 1180×1112×632+
H×W×D mm 1180×900×632 1180×900×632 1180×900×632 1180×1112×632 1180×1112×632 H×W×D mm 1180×1112×632 1180×1112×632 1180×1112×632 1180×1112×632 1180×1112×632

Net Weight Kg 337 342 342 416 412 Net Weight Kg 417 417 491 492 492
Gross Weight Kg 345 350 350 425 421 Gross Weight Kg 426 426 501 502 502
Sound Pressure Level *2 Cooling/Heating dB(A) 56/57 56/57 58/60 56/57 56/58 Sound Pressure Level *2 Cooling/Heating dB(A) 56/58 58/60 56/58 56/58 56/58
Water Temperature*3 °C 10~45 10~45 10~45 10~45 10~45 Water Temperature*3 °C 10~45 10~45 10~45 10~45 10~45
Water Flow Rate L/min 211.0 230.0 253.3 268.3 289.3 Water Flow Rate L/min 308.3 331.7 346.7 360.0 386.7
Water-Side Water-Side
Heat Exchanger Water Pressure Drop kPa / / / / / Heat Exchanger Water Pressure Drop kPa / / / / /
Maximum Pressure Resistance kgf/cm2 20 20 20 20 20 Maximum Pressure Resistance kgf/cm2 20 20 20 20 20
Liquid Pipe mm Ф15.88 Ф15.88 Ф19.05 Ф19.05 Ф19.05 Liquid Pipe mm Ф19.05 Ф19.05 Ф19.05 Ф19.05 Ф19.05
Refrigerant Refrigerant
Low Pressure Gas Pipe mm Ф28.6 Ф28.6 Ф31.75 Ф31.75 Ф31.75 Low Pressure Gas Pipe mm Ф31.75 Ф31.75 Ф31.75 Ф38.1 Ф38.1
Connecting Pipes Connecting Pipes
High/Low Pressure Gas Pipe mm Ф25.4 Ф25.4 Ф25.4 Ф28.6 Ф28.6 High/Low Pressure Gas Pipe mm Ф28.6 Ф28.6 Ф28.6 Ф31.75 Ф31.75

Water Pipe DN32 DN32 DN32 DN32 DN32 Water Pipe DN32 DN32 DN32 DN32 DN32
Water G1-1/4B G1-1/4B G1-1/4B G1-1/4B G1-1/4B Water G1-1/4B G1-1/4B G1-1/4B G1-1/4B G1-1/4B
Thread of Connector Thread of Connector
Connecting Pipes Connecting Pipes
Drain Pipe mm Outer Diameter 18 Drain Pipe mm Outer Diameter 18
Recommended 33 36 39 40 40 Recommended 40 40 40 40 40
MAX. Connectable MAX. Connectable
Indoor Units MAX. 53 58 63 64 64 Indoor Units MAX. 64 64 64 64 64

MAX. Piping Length*4 m 300(500) 300(500) 300(500) 300(500) 300(500) MAX. Piping Length*4 m 300(500) 300(500) 300(500) 300(500) 300(500)

NOTES:
*1. Operation Condition:
Cooling:Indoor Temperature 27oC DB/19oC WB, Water Inlet/Outlet 30/35oC.
Heating:Indoor Temperature 20oC DB/15oC WB, Water Inlet 20oC.
*2. The sound pressure is based on the following conditions.
1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
*3. When unit is operating out of the allowable water temperature range, it won't strat normally and will alarm.
*4. For Max.pipe length more than 300m, please contact our professional engineer.
81/82
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

Hi-FLEXi W Series Heat Recovery HP 42HP 44HP 46HP 48HP 50HP Hi-FLEXi W Series Heat Recovery HP 52HP 54HP 56HP 58HP 60HP
Model Power Supply AC 3Ф, 380 ~ 415V/50Hz(60Hz) AVWW-400FKFW AVWW-418FKFW AVWW-440FKFW AVWW-456FKFW AVWW-476FKFW Model Power Supply AC 3Ф, 380 ~ 415V/50Hz(60Hz) AVWW-494FKFW AVWW-516FKFW AVWW-534FKFW AVWW-550FKFW AVWW-570FKFW
AVWW-96FKFW AVWW-114FKFW AVWW-96FKFW AVWW-96FKFW AVWW-96FKFW AVWW-114FKFW AVWW-136FKFW AVWW-154FKFW AVWW-170FKFW AVWW-190FKFW
Combination AVWW-114FKFW AVWW-114FKFW AVWW-154FKFW AVWW-170FKFW AVWW-190FKFW Combination AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW
AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW AVWW-190FKFW
kW 117.5 123.0 129.0 134.0 140.0 kW 145.5 152.0 157.0 162.0 168.0
Nominal Capacity*1 Nominal Capacity*1
KBtu/h 401.0 419.7 440.3 457.3 477.7 KBtu/h 496.4 518.6 535.7 552.7 573.2
Cooling Operation Cooling Operation
Nominal Input kW 22.3 23.6 24.1 25.5 27.0 Nominal Input kW 28.3 29.8 30.1 31.4 32.9
EER 5.26 5.21 5.35 5.27 5.19 EER 5.14 5.10 5.22 5.16 5.10
kW 132.0 138.0 144.5 150.5 157.5 kW 163.5 171.0 176.0 182.0 189.0
Nominal Capacity*1 Nominal Capacity*1
KBtu/h 450.4 470.9 493.0 513.5 537.4 KBtu/h 557.9 583.5 600.5 621.0 644.9
Heating Operation Heating Operation
Nominal Input kW 22.6 23.8 24.4 25.7 27.0 Nominal Input kW 28.2 29.8 30.1 31.3 32.6
COP 5.85 5.81 5.91 5.85 5.84 COP 5.80 5.75 5.86 5.81 5.80
1030×820×560+ 1030×820×560+ 1030×820×560+ 1030×820×560+ 1030×820×560+ 1030×820×560+ 1030×820×560+ 1030×1040×560+ 1030×1040×560+ 1030×1040×560+
H×W×D mm 1030×820×560+ 1030×820×560+ 1030×1040×560+ 1030×1040×560+ 1030×1040×560+ H×W×D mm 1030×1040×560+ 1030×1040×560+ 1030×1040×560+ 1030×1040×560+ 1030×1040×560+
Outer Dimensions 1030×1040×560 1030×1040×560 1030×1040×560 1030×1040×560 1030×1040×560 Outer Dimensions 1030×1040×560 1030×1040×560 1030×1040×560 1030×1040×560 1030×1040×560

Area m² 1.5 1.5 1.6 1.6 1.6 Area m² 1.6 1.6 1.7 1.7 1.7
1180×900×632+ 1180×900×632+ 1180×900×632+ 1180×900×632+ 1180×900×632+ 1180×900×632+ 1180×900×632+ 1180×1112×632+ 1180×1112×632+ 1180×1112×632+
Packing Dimensions H×W×D mm 1180×900×632+ 1180×900×632+ 1180×1112×632+ 1180×1112×632+ 1180×1112×632+ Packing Dimensions H×W×D mm 1180×1112×632+ 1180×1112×632+ 1180×1112×632+ 1180×1112×632+ 1180×1112×632+
1180×1112×632 1180×1112×632 1180×1112×632 1180×1112×632 1180×1112×632 1180×1112×632 1180×1112×632 1180×1112×632 1180×1112×632 1180×1112×632
Net Weight Kg 583 588 657 658 658 Net Weight Kg 663 663 737 738 738
Gross Weight Kg 596 601 671 672 672 Gross Weight Kg 677 677 752 753 753
Sound Pressure Level *2 Cooling/Heating dB(A) 58/60 58/60 58/60 58/60 58/60 Sound Pressure Level *2 Cooling/Heating dB(A) 58/60 60/62 58/60 58/60 58/60
Water Temperature*3 °C 10~45 10~45 10~45 10~45 10~45 Water Temperature*3 °C 10~45 10~45 10~45 10~45 10~45
Water Flow Rate L/min 404.3 423.3 442.7 456.0 482.7 Water Flow Rate L/min 501.7 525.0 540.0 553.3 580.0
Water-Side Water-Side
Heat Exchanger Water Pressure Drop kPa / / / / / Heat Exchanger Water Pressure Drop kPa / / / / /
Maximum Pressure Resistance kgf/cm2 20 20 20 20 20 Maximum Pressure Resistance kgf/cm2 20 20 20 20 20
Liquid Pipe mm Ø19.05 Ø19.05 Ø19.05 Ø19.05 Ø19.05 Liquid Pipe mm Ø19.05 Ø19.05 Ø22.2 Ø22.2 Ø22.2
Refrigerant Refrigerant
Low Pressure Gas Pipe mm Ø38.1 Ø38.1 Ø38.1 Ø38.1 Ø38.1 Low Pressure Gas Pipe mm Ø38.1 Ø38.1 Ø38.1 Ø38.1 Ø38.1
Connecting Pipes Connecting Pipes
High/Low Pressure Gas Pipe mm Ø31.75 Ø31.75 Ø31.75 Ø31.75 Ø31.75 High/Low Pressure Gas Pipe mm Ø31.75 Ø31.75 Ø38.1 Ø38.1 Ø38.1

Water Pipe DN32 DN32 DN32 DN32 DN32 Water Pipe DN32 DN32 DN32 DN32 DN32
Water G1-1/4B G1-1/4B G1-1/4B G1-1/4B G1-1/4B Water G1-1/4B G1-1/4B G1-1/4B G1-1/4B G1-1/4B
Thread of Connector Thread of Connector
Connecting Pipes Connecting Pipes
Drain Pipe mm Outer Diameter 18 Drain Pipe mm Outer Diameter 18
Recommended 40 40 40 40 40 Recommended 40 40 40 40 40
MAX. Connectable MAX. Connectable
Indoor Units MAX. 64 64 64 64 64 Indoor Units MAX. 64 64 64 64 64

MAX. Piping Length*4 m 300(500) 300(500) 300(500) 300(500) 300(500) MAX. Piping Length*4 m 300(500) 300(500) 300(500) 300(500) 300(500)

NOTES:
*1. Operation Condition:
Cooling:Indoor Temperature 27oCDB/19oC WB, Water Inlet/Outlet 30/35oC.
Heating:Indoor Temperature 20oC DB/15oC WB, Water Inlet 20oC.
*2. The sound pressure is based on the following conditions.
1 Meter from the unit service cover surface, and 1.5 Meters from floor level.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
*3. When unit is operating out of the allowable water temperature range, it won't strat normally and will alarm.
*4. For Max.pipe length more than 300m, please contact our professional engineer.
83/84
OUTDOOR UNIT Product Line

Hi-Smart H Series Wide Operation Range

The highest operation temperature reaches to 46oC* in cooling mode, and lowest operation temperature reaches to
-20oC* in heating mode.

DC inverter-driven compressor
Low noise technologies
Compact and lightweight design
Unique electrical system insect-resistant design
Optimized air duct system design

Note:The double fan achieves the lowest operation temperature that can reach to -20oC in heating mode.

Electrical System Insect-resistant Design


Aviation Level Design of Grilling
Electrical system adds insect-resistant design that effectively prevents insect from damaging the electrical system and
improves the electrical system.
Hi-Smart H Series creates a high-quality quiet environment. The design of the grilling follows the design concept of the
aircraft engine design, which conforms to the aerodynamics principle. The noise has been greatly reduced. The grilling
also increases safety as being a preventative for child figure being injured by the fan blade.
Optimized Air Duct System Design
Optimized air duct system design improves air supply distance and avoids short circuit of return air and improves heat
exchange ability.

Similarly, the wind speed of 0.8m/s is taken as the critical judgment point. According to the measured results, the air
supply distance of the grille before changing is 3.7m.The modified air supply distance is 4.6m and the air supply distance
is increased by about 24%.
85/86
OUTDOOR UNIT Product Line

AHU-CONNECTION KIT Outdoor Unit Specifications

The Air-handing units connect to the Hisense VRF system through the AHU-KIT, which can provide more flexible air
conditioning solutions and save more cost.

Main Function

ON/OFF Control Temperature Setting


Capacity Demand Operation Mode

Model(HP) 3 4 5 5

Model AVW-28HJFH AVW-34HJFH AVW-43HJFH AVW-43HKFH

Power Supply - AC 220~240V 1Φ 50/60Hz AC 380~415V 3Φ 50/60Hz

Nominal kBtu/h 27.3 34.1 42.7 42.7


Capacity
Cooling kW 8.0 10.0 12.5 12.5
Operation
Power kW
Consumption 1.93 2.34 2.98 3.81

Control Box EER 4.15 4.27 4.19 3.28


Wired Controller
Nominal kBtu/h 32.4 38.2 47.8 47.8
Capacity
Heating kW 9.5 11.2 14.0 14.0
Operation
Power kW 2.37 3.01 4.15 3.68
Consumption
COP 4.01 3.72 3.37 3.80

Air Flow Rate m³/min 46.5 69.0 78.0 75.0

Out Dimension(H×W×D) mm 800×950×370 800×950×370 800×950×370 800×950×370

Packing Dimension(H×W×D) mm 930×1025×460 930×1025×460 930×1025×460 930×1025×460

Net Weight kg 65 73 78 84

Gross Weight kg 72 81 86 96
Expansion
Valve Box Liquid Line
Refrigerant mm(in.) Φ9.53(3/8) Φ9.53(3/8) Φ9.53(3/8) Φ9.53(3/8)
AHU
Piping
Gas Line mm(in.) Φ15.88(5/8) Φ15.88(5/8) Φ15.88(5/8) Φ15.88(5/8)

Max. number of connectable IDU 5 6 8 8


Sound Pressure Level
(Cooling/Heating) dB(A) 50/52 53/55 54/57 55/57
o
Cooling C DB -5~46
Operation
Range o
Heating C WB -15~15.5 -15~15.5

Branch pipe HFQ-052F

Compressor Type Rotary Scroll


Refrigerant Pipe
Sensor Signal Notes:
Wired Controller Wired Controller
Communication Wire *1.The nominal cooling capacity and hesting capacity are based on following conditions:
Cooling Operation Conditions
Indoor Air Inlet Temperature:27.0oC DB(80°F DB) Indoor Air Inlet Temperature:20oC DB(68°F DB)
19.0oC DB(66.2°F DB) Outdoor Air Inlet Temperature:7oC DB(45°F DB)
6oC DB(43°F DB)
Piping Length:7.5Meters Piping Lift:0Meters
*2.The sounf pressure level is based on following conditions:
1.5m beneath the unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
87/88
OUTDOOR UNIT Product Line

Outdoor Unit Specifications

Model(HP) 4 5 6 5 6 Model(HP) 8 10 12 8 10 12

Model AVW-38HJFH AVW-48HJFH AVW-54HJFH AVW-48HKFH AVW-54HKFH Model AVW-76HKFH AVW-96HKFH AVW-114HKFH AVW-76H9FH AVW-96H9FH AVW-114H9FH

Power Supply - AC 220~240V 1Φ 50/60Hz AC 380~415V 3Φ 50/60Hz Power Supply - AC 380~415V 3Φ 50/60Hz AC 220V 3Φ 60Hz

kBtu/h 38.2 47.8 52.9 47.8 52.9 Nominal kBtu/h 76.5 95.6 114.3 76.5 95.6 114.3
Nominal
Capacity
Capacity Cooling kW 22.4 28.0 33.5 22.4 28.0 33.5
Cooling kW 11.2 14.0 15.5 14.0 15.5
Operation Operation
Power Power kW
kW 2.60 3.46 4.21 3.92 4.44 Consumption 6.36 7.80 10.60 6.30 8.30 10.70
Consumption
EER 4.31 4.05 3.68 3.57 3.49 EER 3.52 3.59 3.16 3.56 3.37 3.13

kBtu/h 42.7 54.6 61.4 54.6 61.4 Nominal kBtu/h 85.3 107.5 128 85.3 107.5 128
Nominal
Capacity Capacity
Heating kW 12.5 16.0 18.0 16.0 18.0 Heating kW 25.0 31.5 37.5 25.0 31.5 37.5
Operation Operation
Power Power kW 5.81 7.00 10.11 5.9 7.8 9.9
kW 2.78 3.71 4.47 4.03 4.74 Consumption
Consumption
COP 4.50 4.31 4.03 3.97 3.80 COP 4.30 4.50 3.71 4.24 4.04 3.79

Air Flow Rate m³/min 90.0 90.0 100.0 90.0 100.0 Air Flow Rate m³/min 150.0 163.0 163.0 121 150 163

Out Dimension(H×W×D) mm 1380×950×370 1380×950×370 1380×950×370 1380×950×370 1380×950×370 Out Dimension(H×W×D) mm 1650×1100×390 1650×1100×390 1650×1100×390 1650×1100×390 1650×1100×390 1650×1100×390

Packing Dimension(H×W×D) mm 1520×1025×460 1520×1025×460 1520×1025×460 1520×1025×460 1520×1025×460 Packing Dimension(H×W×D) mm 1748×1151×500 1748×1151×500 1748×1151×500 1748×1151×500 1748×1151×500 1748×1151×500

Net Weight kg 93 95 97 103 103 Net Weight kg 160 170 170 168 168 171

Gross Weight kg 111 111 111 118 118 Gross Weight kg 179 194 194 179 179 182

Liquid Line mm(in.) Φ9.53(3/8) Φ9.53(3/8) Φ9.53(3/8) Φ9.53(3/8) Φ9.53(3/8) Refrigerant Liquid Line mm(in.) Φ12.7(1/2) Φ12.7(1/2) Φ12.7(1/2) Φ9.53(3/8) Φ12.7(1/2) Φ12.7(1/2)
Refrigerant
Piping Piping
Gas Line mm(in.) Φ15.88(5/8) Φ15.88(5/8) Φ15.88(5/8) Φ15.88(5/8) Φ15.88(5/8) Gas Line mm(in.) Φ22.2(7/8) Φ25.4(1/1) Φ25.4(1/1) Φ19.05(3/4) Φ22.2(7/8) Φ25.4(1/1)

Max. number of connectable IDU 9 11 11 11 11 Max. number of connectable IDU 15 17 19 10 10 10


Sound Pressure Level Sound Pressure Level
dB(A) 50/52 52/54 53/55 48/50 50/52 (Cooling/Heating) dB(A) 58/60 59/61 59/61 53/55 56/58 56/61
(Cooling/Heating)
o
Cooling o
C DB -5~46 Cooling C DB -5~46
Operation Operation
Range Range o
Heating o
C WB -20~15.5 Heating C WB -20~15.5

Branch pipe HFQ-052F Branch pipe HFQ-162F

Compressor Type Rotary Scroll Compressor Type Scroll

Notes: Notes:
*1.The nominal cooling capacity and hesting capacity are based on following conditions: *1.The nominal cooling capacity and hesting capacity are based on following conditions:
Cooling Operation Conditions Cooling Operation Conditions
Indoor Air Inlet Temperature:27.0oC DB(80°F DB) Indoor Air Inlet Temperature:20oC DB(68°F DB) Indoor Air Inlet Temperature:27.0oC DB(80°F DB) Indoor Air Inlet Temperature:20oC DB(68°F DB)
19.0oC DB(66.2°F DB) Outdoor Air Inlet Temperature:7oC DB(45°F DB) 19.0oC DB(66.2°F DB) Outdoor Air Inlet Temperature:7oC DB(45°F DB)
6oC DB(43°F DB) 6oC DB(43°F DB)
Piping Length:7.5Meters Piping Lift:0Meters Piping Length:7.5Meters Piping Lift:0Meters
*2.The sounf pressure level is based on following conditions: *2.The sounf pressure level is based on following conditions:
1.5m beneath the unit. 1.5m beneath the unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
89/90
AIR TO WATER HEAT PUMP Product Line

Hi-AquaSmart Series
High-efficiency Air to Water Heat Pump Less CO2 Emissions
3 in 1 Solution
Using a heat pump can significantly reduce CO2 emissions.
Hisense air to water heat pump system absorbs the free energy from outside atmosphere, which only consume less
electricity to generate more heat energy.Hi-AquaSmart Series have better performance, high efficiency, high energy-
saving, less CO2 emissions.This Series can be easy to install on new building or existing building. High efficient Hisense Lower CO2 emissions
air to water heat pumps can obviously reduce the energy consumption of the building. In addition, it can work with a Because heat pumps collect free energy from the air,
traditional heating source,such as oil or gas boiler. they produce much less CO2.

66% less than Electric Heating


50% less than Oil Heating
30% less than Gas Heating

Economical
Average annual running cost

Compared to the other heating modes, such as electricity, Direct electric heating
gas, coal/oil, solar,and so on, the heat pump system is more
efficient and the annual cost reduction is obvious. Fuel boiler

Gas condensing boiler

Hi-AquaSmart

7/9/12kW 14/16kW

High Efficient Water Pump (DC)


Enhanced Vapor Injection
Hisense adopts vapor injection scroll compressor, which provides higher compression ratio, smoother oil supply and
lower noise level. Hi-aquasmart Series is equipped with a high efficient DC(inverter) water
pump,which can minimize energy consumption during operating time.
It has a better linear controllable for capacity output and wider adaptability for
many application places compared with AC water pump.

COP up to 4.84
Hi-AquaSmart Series is efficient, all products' COP is highter than 4.1, successfully meeting
customers' requirements.
6

5 Cpacity Hisense Brand A Brand B


Increasing the suction of compressor and 4.4 4.4
enhancing the heating capacity 4 7kw 4.5
9kw 4.62 4.23 4.65
3 4.5 4.62 4.1 4.84 4.74
12kw 4.1 4.49 4.45
2 14kw 4.84 4.44 4.22
The vapor injection system and stepless inverter technique greatly improve the refrigerant cycle system. It effectively
1 16kw 4.74 4.2 4.1
increases refrigerant flow through vapor injecting, thus substantially enhancing the heating capacity.
7KW 9KW 12KW 14KW 16KW * Peak value
0 * at standard condition working at heating capacity at +7℃ ( heating water at 35℃)
91/92
AIR TO WATER HEAT PUMP Product Line

Strong Heating Capacity Under Low Ambient


Heating capacity(kW)
20
Hi-AquaSmart 14kw outdoor unit can maintain 18
the same nominal capacity even at -15°C without 16
16 16 16 16
Specification for Outdoor unit
electrical booster heater,and 16kw outdoor unit 14
14 14 14 14 14 14

also can maintain the same nominal capacity even at 12 Outdoor unit AHW-070UCSDP AHW-090UCSDP AHW-120UCSDP AHW-140UCSEP AHW-160UCSEP
10
-10°C without electrical booster heater. So designer Indoor unit AHM-070UXCSAPA3 AHM-160UXCSAPA3
8
don't need to oversize the heat pump's capacity even 6 Refrigerant R410A
at outdoor temperatures as low as -15°C. 4 Power supply AC1Φ,220~240V/50Hz
2
0
7℃ 2℃ -7℃ -10℃ -15℃ 7℃ 2℃ -7℃ -10℃ -15℃
Compressor Double-rotor compressor Scroll compressor with Vapor-injected
AHW-140UCSDP AHW-160UCSDP
Condition 1 Heating kW 7 9 12 14 16
Ta7/6°C LWC35°C capacity
(DT= 5°C) 4.50 4.62 4.10 4.84 4.74
Assembly Various Heat Sources
COP
Condition 2 Heating kW 6.2 8.1 10.8 12.5 14.8
capacity
Ta7/6°C LWC45°C
(DT= 5°C) COP 3.87 3.97 3.53 3.70 3.95
Hi-AquaSmart is allowed to combine with existing boiler or solar, so undoubtedly Hi-AquaSmart will be the best Cooling Cooling
capacity kW 6.5 8 10.5 12 13.5
alternative to traditional boiler system in old building, and also as a hot water back-up solution to the existing boiler. Ta35°C LWE18°C
(DT= 5°C) EER 3.00 2.90 2.80 2.77 2.53
In case that one heating unit was not working due to some unforeseen problem, this system can ensure heating
system no stopping. Dimensions H*W*D mm 800×950×370 1380x950x370
Heating °C -20~35
Operation Ambient DHW
Range °C -20~43
cooling °C 10~43
Heating Sound pressure dB(A) 51 52 54 51 52
Cooling Sound pressure dB(A) 50 51 53 50 51

Note:
The cooling and heating performance in agreement with EN14511.
Heating condition: Outdoor Air Temperature 7 oC DB/6oC DB, Inlet/Outlet water temperation 30oC/35oC.
Cooling condition: Outdoor Air Temperature 35oC, Inlet/Outlet water temperation 12oC/7oC.
Piping length:7.5 meter; Piping lift:0 meter

Central Hot Water Tank


Note: The water tank could be sourced locally,
Please contact with technicians for
specification required.

Specification for Indoor unit


AHM- AHM-
Capacity 070UXCSAPA3 160UXCSAPA3

Power supply AC1Φ,220~240V/50Hz

Heating capacity kW 7 16

Hot water capacity kW 7 16


Power input kW 0.245 0.245
Dimensions H*W*D mm 890×520×320
Operation system Net Weight kg 55 58

Underfloor heating Domestic hot water Heat Exchanger plate heat exchanger
Low temperature radiators Hi-aquasmart+solar/boiler(optional) Heating °C 15~55 15~55
Hot water DHW °C 15~55 15~55
temperature
Temperature Sensor Check Valve Decantation tank cooling °C 5~25 5~25
Sound pressure level dB(A) 33 33
S Security Thermostat Motorized 2 ways Valve Expansion tank
gas mm 9.53 9.53
Piping
Regulator Motorized 3 ways Valve connections mm 15.88 15.88
liquid
Electric Heater type DC DC
Water pump
brand Grundfos Grundfos
Water Pump
Booster heating kw 3 3
93/94
AIR TO WATER HEAT PUMP Product Line

Radiant floor heating is the most comfortable, optimal heating system nowadays.
Hisense Multifunction VRF radiant floor heating system utilizes Hisense’s leading multi-split technology and advanced
air-source heat pump technology, which is outstanding in floor heating system with integration of high efficiency, comfort
and environmental protection.
MULTI-FUNCTION Series
Dual Water Temperature Control Technology
Fixed Water Temperature Control (Fix Control Mode):
The supplied water temperature maintains constant during operation, Users can
Home Central Air Conditioning ·Radiant Floor Heating·Domestic Hot Water 3 in 1 set supplied water temperature value within the range of 20~55oC. ℃

Hisense Multifunction VRF System is a multifunctional intelligent ecology home system with integration of home central Variable Temperature Control (OTC Control Mode):
air conditioning, radiant floor heating and domestic hot water. Utilizing high efficient DC inverter technology, air source System automatically adjusts water temperature according to temperature
heat pump technology and heat recovery technology, it builds a more intelligent and more comfortable modern home life. compensation curve basing on outdoor temperature to achieve optimum indoor
temperature and reduce system power consumption. The compensation curve
can also be adjusted manually according to operation conditions to realize energy Fixed Temperature Control Mode
saving.
High Efficiency Wide Operation Range
Setting Water Temp (oC)
Comfort and Health Stable and Reliable ℃
Under OTC control, the user respectively sets outside
Hidden Beauty 44
Point A air temperature value and target water temperature
value of point A and B, the system will automatically
generate OTC curve according to the setting, thereby
to arrive at the target water temperature value for
each ambient temperature, the benefit of this setting
+8oC is energy saving, because we reduce the demand for
Point B
20 heat as the rise of ambient temperature.
-8oC After curve is generated, users can also adjust the
water temperature by wired remote control with ±8oC.

Fixed Temperature Control Mode


Central Air-conditioning -20 +20 Outdoor Temp.(oC)

Ideal choice of high


quality home life,
perfect integration
with top-grade interior

Safe and Reliable


decoration .
Indoor Unit

Floor heating pipes are laid under the floor with advantages such as good stability, less vulnerable to external damage and
corrosion, and its lifespan is almost the same with the building. Compared with other heating equipment, the cost of repair
and maintenance afterwards is greatly reduced. At the same time, gas leak, explosion or other accidents caused by gas or
stove can be avoided.
Radiant Floor Heating

Ideal heating in winter,


Operation protection of the water system Water system safeguards
Hydronic Module preserve health and
comfort, clean and Starting water pump automatically to avoid water Besides safety valve and exhaust valve,
quiet.
scale generation and ensure the operation of the water flow switch and low pressure Water
Leakage
water pump, three-way valve or other waterways switch have been added into system, which
Three-way Valve
parts. can effectively avoid water leakage, water
depletion, electric heater dry burning and Water Dry
Timing Operatifon other accidents. Depletion Burning

Antifreezing Protection of Water System Commissioning Protection of Floor Heating


Automatic antifreezing Water temperature curve Floor heating pipes need
under standby mode
Domestic Hot Water function can avoid pipe ℃
to warm gradually at the Outlet Water Temperature
Provide required hot
cracking, leakage and other T3 beginning of operation, (℃)
water for home life, with
automatic sterilization
accidents when equipment in order to prevent
function, convenient is not used in winter. problems such as floor
and healthy.
T2 deformation or leakage
Under standby mode caused by sudden
Water Replenishing
Hisense Multi-function Series heat. Commissioning
T1
Central Hot Water Tank Electric heating starts protection can ensure
Outdoor Unit Constantly test the water temperature of
Pump starts
inlet and outlet pipes. When the temperature safe run testing. Number
is below T2, the pump starts. When of days
the temperature is below T1, the pump Floor Heating Run Testing
and electric heating start until the water Electric heating starts Pump starts t
temperature rises to T3.
Note:The water tank could be sourced locally, Please contact with technicians for specification required.
95/96
AIR TO WATER HEAT PUMP Product Line

Hisense home central air conditioning has been widely recognized by the market and users owning to its intelligence,
Hisense Multifunction VRF hot water system enables constant healthy hot water supply around the clock
comfort, high-efficiency and energy saving.
Requirements for high-quality decoration and more comfort in villa and luxury residence make Hisense home central
Multiple Hot Water Production Mode air conditioning play a principal role in home daily life.
Hisense, the mark of high-quality life!

Heat Recovery Mode


Under cooling operation in summer, the heat discharged
Delicate and Convenient
Cooling
operation
from outdoor unit can be recovered directly and used for
Waste heat
heating domestic hot water, allowing you to enjoy free and
recovery convenient hot water supply.
Power consumption analysis
Outdoor unit can be easily installed in small space, one outdoor unit can
When heating water by heat recovery mode, indoor unit performs cooling
Power consu- simultaneously satisfy the need for cool and warmness of multiple rooms, extending
operation, the heat discharged from indoor unit is recovered and used for mption index
heating domestic hot water. Producing domestic hot water does not consume indoor exquisiteness and beauty to outdoors at the meantime.
Domestic hot water additional power, thereby the produced domestic hot water can be regarded as
being acquired free of charge. 0%

Electric energy
Heat Pump Mode
"Three-dimensional" Cozy and Warm Feeling
Compressor
When the desired domestic hot water temp is below 55oC,
hot water can be heated using air source heat pump,
saving more than 60% of electricity than direct electric
Energy output:
3-5 times of Condenser Evaporator heating.
energy input
Energy input
Unique 2+1 dimensional temperature sensation
Power consumption analysis
When using heat pump to heat hot water, power consumption required for Power consu- Three temperature sensors including particular one on indoor unit
mption index
producing one share of hot water is only 33% of the heat required for heating air outlet can intelligently sense the temperature change of each
33%
Power consu-
Reservoir hot water when COP=3.0.
sensitive point indoors and outdoors, dynamically calculate and
mption index Too hot Too hot

Throttle
adjust real-time output of compressor system, and balance the So comfortable

energy exchange variation of each room. Soft air supply keeps


tiny temperature fluctuations in an optimum condition and brings So comfortable

Electric Heating Mode


Too cold Too cold

gentle refreshing and intimate warmth.


When the desired domestic hot water temp is higher than Start Time

55oC, use energy-efficient heat pump to heat water to 55oC, Traditional temperature control Hisense 2+1 temperature sensation

then use auxiliary electric heating to heat water to a high Comfortable air supply
temperature up to at most 75oC.
Hisense indoor unit can adopt multiple air supply modes such as
Electric heater Power consumption analysis
ceiling-supply and ceiling-return, side-supply and back-return,
Power consu- side-supply and bottom-return etc. according to room structure,
When heating hot water by electric heating, heat required for producing one mption index
share of hot water need consume electricity equivalent to the same amount of making the air flow distribution more excellent. The airflow can be
heat in the case of 100% of efficiency conversion.
100% distributed to every corner, more uniform temperature distribution
and more comfort . Home central air conditioning 360-degree air supply design
Person is in the back flow area of air conditioning More uniform temperature in air conditioning area

Multifunction VRF Hot Water Production Flow and Water Tank Temperature Range

Wide Operating Range
The tank water can be heated up to 75℃
Summer Indoor unit cooling Recover waste heat for heating hot water
(Cooling operation) waste heat recovery Water is heated to about 50 ℃
55℃ DB Sterilization
function setting
Auxiliary electric 46℃ DB
Transitional season
(neither cooling nor heating) Use heat pump to heat hot water, water is
heating is started, Outlet water System can handle a wide range of outside air condition. The
water is heated to temperature

Winter (floor heating is not in use)


heated to about 50℃
70℃ -75℃ lowest temperature in winter is -20oC WB, which can meet 15.5℃ WB
Cooling
20℃ DB the heating needs of cold regions.
Winter Heating
(floor heating is in use)
Water tank temperature
-5℃ DB
-20℃ WB
Note: The actual data are closely related to using environment and conditions, the above data are for reference only.
System operating range
97/98
AIR TO WATER HEAT PUMP Product Line

Hydronic Module
Model AFM-54EX4SA

Power Supply AC1Ф, 220~240V/50HZ

Rated Cooling Capacity kW _

Rated Heating Capacity kW 16

Electrical Heater Capacity kW 3

Outdoor Unit Parameters


Cabinet Color lvory White
Shell
Materialr Steel
Dimensions
Model AFW-38U4SC AFW-48U4SC AFW-54U4SC (Height × Width×Depth) mm 890×520×320
Rated Capacity (1) kW 11.2 14 16
Net Weight kg 58
Rated Power (1) kW 2.51 3.21 3.77 Weight
Gross Weight kg 74
COP (1) - 4.46 4.36 4.24
Heating(A2W) Capacity (A 2°C/W 35°C)(2) kW 8.96 11.2 12.8 Type Constant
COP (A 2°C/W 35°C)(2) - 3.12 3.05 2.97 Water Pump Lift kpa 60
Capacity(A -7°C/W 35°C)(3) kW 8.6 10.8 12.3
Input W 151
COP (A -7°C/W 35°C)(3) - 2.2 2.14 2.09
Type Plate heat exchanger
Heating (35°C) A+ A+ 127%,A+
Energy Efficiency Grade
Heating (55°C) A+ A+ 118%,A+ Number 1
Rated Capacity (4) kW 11.2 14 15.5 Water Storage Capacity L 2.91
Cooling(A2A) Rated Power (4) kW 2.99 3.92 4.44
Water Pipe Minimum Flow L/min 18
EER (4) - 3.75 3.57 3.49
Rated Flow L/min 45.8
Rated Capacity (4) kW 12.5 16 18
Heating(A2A) Rated Power (4) kW 2.98 4.03 4.74 Maximum Flow L/min -
COP (4) - 4.19 3.97 3.8 Insulation Material Foamed plastic
Outer Dimensions mm
(Height × Width × Depth) 1380×950×370 Volume L 8
Weight Kg 102 103 104 Expansion Tank Maximum Pressure bar 3
Sound Pressure level (5) dB(A) 50/53 51/54 53/55
The pre pressure bar 1
Sound Power Level (5) dB(A) 67 68 69
Pore Size mm 1
Power Supply Ф,V,Hz AC1Ф,1220-240~, 50Hz Water Filter
Inverter Type - DC Inverter Material Brass
Cabinet Color - ivory White Interface Size inch G1-1/4”
Heat Exchanger - Multi-Pass Cross-Finned Tube
Water Circulating Pipe Size inch G1-1/4”
Compressor Type - Hermetic (Scroll) System
Outdoor Units Safety Valve Specification bar 3
Compressor Output kW 2.2 2.5 2.8
Compressor Startup Mode - Directly startup Total Water Storage L -
Fan Type - Axial flow fan Gas Pipe Size mm Ф12.7
Refrigerant circulating
Fan Output w 51×2 51×2 51×2 System
Liquid Pipe Size mm Ф9.53
Fan Air Volume m3/min 90 90 100
Sound Pressure Level dBA 32
Fan Startup Mode - Directly startup
Temperature of Outdoor Air °CDB -23~43
Cooling Operation Range °C -5 ~ 43 Operation range
(Outdoor Air Inlet Temperature) Temperature of Water Supply °C 20~55
Heating Operation Range °C -23 ~ 15
(Outdoor Air Inlet Temperature)
Floor Heating Operation Range
(Outdoor Air Inlet Temperature) °C -23 ~ 15

Domestic Hot Water Operation Range


(Outdoor Air Inlet Temperature) °C -23 ~ 43 Central Hot Water Tank
Liquid Line mm Ф9.53
Installation Data High Pressure Gas Line mm Ф12.7
Gas Line mm Ф15.88
Type - R410A
Refrigerant Refrigerant Charge kg 3.6
Flow Control - Micro-Computer Control Expansion Valve

Note:The water tank could be sourced locally, Please contact with technicians for
NOTES:
When the connectiong capacity rate or indoor unit and outdoor unit is 100%,the cooling capacity and heating capacity are based on the following conditions: specification required.
1. Heating(A2W) conditions: Water inlet/outlet temperature:30°C DB(86°F DB)/35°C DB(95°F DB), Outdoor air inlet temperature:7°C DB(45°F DB), 6°C WB(43°F WB)
2. Heating(A2W) conditions: Water inlet/outlet temperature:30°C DB(86°F DB)/35°C DB(95°F DB), Outdoor air inlet temperature:2°C DB(35.6°F DB)
3. Heating(A2W) conditions: Water inlet/outlet temperature:30°C DB(86°F DB)/35°C DB(95°F DB), Outdoor air inlet temperature:-7°C DB(19.4°F DB)
4. Cooling(A2A) conditions: Piping length: 7.5 meters Indoor ait inlet temperature: 27°C DB(80°F DB), 19.0°C WB(66.2°F WB) Outdoor air inlet temperature:35°C DB(95°F DB) Heating(A2A) conditions:Indoor air inlet temperature: 20°C
DB(68°F DB), 15.0°C WB(59°F WB) Outdoot air inlet temperature: 7°C DB(45°F DB),6°C WB(43°F WB)
5. The sound pressure level is based on following conditions: 1Meter from the unit service cover surface, and1.5 Meters fron floor level, The above data was measure in an anechoic chamber so that reflected sound should be taken into
consideration in the field
6.The final appearance of outdoor unit is subject to the actual product.
99/100
INDOOR UNIT Product Line

Hisense Hi-FLEXi & Hi-Smart Series provide a wide selection of indoor units for
indoor decoration and create a personalized living space. Various Model Types Easily Match Different
Wide capacity range of outdoor units enables free model
HP 0.6 combination according to the actual situation of building.
kBtu/h 5 There are 12 types of indoor units for selection. Customer
can choose appropriate type and capacity of indoor units
1-Way Cassette Type
according to interior decoration and functions.

Flexible Ways of Air Supply and Air Return


2-Way Cassette Type Different duct types can be chosen to mactch different construction structure and interior decoration, which meets
various personalized requirement of customers.

4-Way Cassette Type

Mini 4-Way
Cassette Type

Side Supply Ceiling Return


Ceiling Supply Ceiling Return Side Supply Ceiling Return Side Supply Side Return
without Air Return Duct
Ceiling Ducted Type
(High Static Pressure)
Note:Side Supply Bottom Return will increase the noise level by 5-10 dB. It is not recommend to use in the environment which has high level requirement of noise.

Ceiling Ducted Type


(Low Static Pressure)
Precise Room Temperature Control
Hisense sets temperature sensors on air outlet /air inlet of indoor units and remote controller, and adopts
microcomputer control 2000-pulse high precision electronic expansion valve to adjust refrigerant flow rate, high
Ceiling Ducted Type precision electronic expansion valve to adjust refrigerant flow rate, which can maintain the room temperature within
(AC Low-height) 0.5℃ of setting temperature and satisfy the indoor comfort requirement.

Top Class Low Noise Design


Ceiling Ducted Type
(DC Low-height) In accordance with application situation and structure, Hisense has been studying the technical and installation
methods for noise reduction of indoor units from various aspects of fan motor, fan blade and air duct layout, which
provides customers with the quietest air conditioned environment.

Ceiling & Floor Type

30dB(A) Noise LevelHave


Whisper Operation No Impact on Sleep Quiet Library Street
Wall Mounted Type

Floor Concealed Type

20dB(A) 21dB(A) 30dB(A) 40dB(A) 70dB(A)


Ceiling Ducted Type

Console Type
101/102
INDOOR UNIT Product Line

1-Way Cassette Type 2-Way Cassette Type

Fashionable Appearance, Convenient Installation 2-way Individual Louver


Customers can choose the installation The newly equipped individual
method according to different situation. louver setting function allows
The concise fashion elements style is the angles of the 2 louvers
suitable for renewal projects and un- to be adjusted individually.
decorated shopping malls or classrooms.

Efficiency DC Motor, Adjustable Air Speed Fresh Air Introducing Efficiency DC Motor, Adjustable Air Speed The Design of Low Noise
Adoption of the efficient DC motor and the optimized duct The unit can introduce fresh air from the external environment. The adoption of the efficient DC motor and the optimized The high efficiency turbofan form the wind pressure by
design assure the smooth air flow. With the filter facility, the air quality is garunteed. duct design assure the smooth air flow. rotating. Larger fan blades and slower fan speed realize the
low operating noise.

Wider 3D-air Flow Range


Standard Equipped Drain Pump Super Compact Structure Design, Easy for Fresh Air Introducing
Broad air deflector design realized broad air supply range.
The wind direction can be adjusted accordingto the need Standard equipped drain pump with the maximum drainage Installation The unit can introduce fresh air from the external environment.
thus makes the customers feel more comfortable. height up to 1200mm. With the filter facility, the air quality is ensured.

Standard Equipped Drain Pump


Indoor unit 1-Way Cassette Type
The maximum drainage height up to 1200mm.
AC1Φ 220V~240V
Model Power Supply /50Hz/60Hz AVY-07UXJSJA AVY-09UXJSJA AVY-12UXJSJA AVY-14UXJSJA AVY-18UXJSKA AVY-24UXJSKA
Indoor unit 2-Way Cassette Type
kW 2.2 2.8 3.6 4.0 5.6 7.1

Cooling Operation kcal/h Model Power Supply AC1Φ 220V~240V AVL-07 AVL-09 AVL-12 AVL-14 AVL-18 AVL-24 AVL-27 AVL-30 AVL-38 AVL-48 AVL-54
1,900 2,400 3,100 3,400 4,800 6,100
/50Hz/60Hz UXJSGA UXJSGA UXJSGA UXJSGA UXJSGA UXJSGA UXJSGA UXJSGA UXJSHA UXJSHA UXJSHA
Btu/h 7,500 9,600 12,300 13,600 19,100 24,200
kW 2.2 2.8 3.6 4.3 5.6 7.1 8.4 9.0 11.2 14.0 16.0
kW 2.5 3.2 4.0 4.5 6.3 8
Cooling Operation kcal/h 1,900 2,400 3,100 3,700 4,800 6,100 6,900 7,700 9,600 12,000 13,800
Heating Operation kcal/h 2,100 2,700 3,400 3,800 5,400 6,800
Btu/h 7,500 9,600 12,300 14,700 19,100 24,200 28,700 30,700 38,200 47,800 54,600
Btu/h 85,00 10,900 13,600 15,400 21,500 27,300
kW 2.8 3.3 4.0 4.9 6.5 8.0 9.0 10.0 13.0 16.0 18.0
Noise Level dB(A) 33/32/31/30/29/28 35/34/32/31/29/28 40/36/35/33/30/29 40/36/35/33/30/29 41/39/36/35/33/31 48/46/43/40/37/33
Heating Operation kcal/h 2,400 2,800 3,400 4,200 5,600 6,800 7,800 8,600 11,200 13,800 15,500
H mm 192 192 192 192 192 192
Btu/h 9,600 11,300 13,600 16,700 22,200 27,300 30,700 34,100 44,400 54,600 61,400
Outer Dimensions W mm 910 910 910 910 1,180 1,180
Noise Level dB(A) 32/30/29/27 33/30/29/28 34/31/30/28 40/37/34/32 42/39/36/33 45/42/40/36 47/44/40/36 49/46/42/37 46/44/40/38 48/45/42/38 49/46/43/40
D mm 470 470 470 470 470 470
H mm 298 298 298 298 298 298 298 298 298 298 298
Net Weight kg 19 19 20 20 24 24
Outer Dimensions W mm 860 860 860 860 860 860 860 860 1,420 1,420 1,420
Air Flow Rate m3/h 372/354/336/306/288/276 396/372/336/306/288/276 498/438/408/372/336/306 498/438/408/372/336/306 726/594/528/492/468/396 936/756/672/594/504/426 D mm 630 630 630 630 630 630 630 630 630 630 630

Motor Power W 40 40 40 40 60 60 Net Weight kg 22 22 22 24 24 24 24 24 39 39 39

Air Flow Rate m3/h 600/510 660/564 720/630 900/792 1,020/894 1,140/984 1,260/1,104 1,320/1,158 1,800/1,584 2,100/1,848 2,220/1,950
Refrigerant Piping Connection Flare-nut Connection (with Flare Nuts) /432/360 /492/396 /534/450 /690/594 /780/672 /858/738 /936/756 /978/786 /1,386/1,188 /1,614/1,266 /1,704/1,446
Liquid Line mm Ф6.35 Ф6.35 Ф6.35 Ф6.35 Ф6.35 Ф9.53 Motor Power 57 57 57 57 57 57 57 57 57x2 57x2 57x2

Gas Line mm Ф12.7 Ф12.7 Ф12.7 Ф12.7 Ф15.88 Ф15.88 Refrigerant Piping Connection Flare-nut Connection(with Flare Nuts)

Condensate Drain VP25 (Outer Diameter Ф32) Liquid Line mm Ф6.35 Ф6.35 Ф6.35 Ф6.35 Ф6.35 Ф9.53 Ф9.53 Ф9.53 Ф9.53 Ф9.53 Ф9.53

Panel Model HP-D-NA HP-D-NA HP-D-NA HP-D-NA HP-E-NA HP-E-NA Gas Line mm Ф12.7 Ф12.7 Ф12.7 Ф12.7 Ф15.88 Ф15.88 Ф15.88 Ф15.88 Ф15.88 Ф15.88 Ф15.88

Cabinet Color Neutral White Condensate Drain VP25(Outer Diameter Ф32)

H mm 55 55 55 55 55 55 Panel Model HP-C-NA HP-C-NA HP-C-NA HP-C-NA HP-C-NA HP-C-NA HP-C-NA HP-C-NA HP-F-NA HP-F-NA HP-F-NA
Panel Outer Dimensions W mm 1,100 1,100 1,100 1,100 1,370 1,370 Cabinet Color Neutral White
D mm 550 550 550 550 550 550 H mm 30 30 30 30 30 30 30 30 30 30 30
Net Weight kg 5 5 5 5 6 6 Panel Outer Dimensions W mm 1,100 1,100 1,100 1,100 1,100 1,100 1,100 1,100 1,660 1,660 1,660
D mm 710 710 710 710 710 710 710 710 710 710 710
NOTES: Net Weight kg 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 10.5 10.5 10.5
1. The nominal cooling capacity is based on following conditions:
Indoor Air Inlet Temperature: 27°C DB(80°F DB), 19.0°C WB(66.2°F WB) Outdoor Air Inlet Temperature: 35°C DB(95°F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter NOTES:
2. The sound pressure level is based on following condations: 1. The nominal cooling capacity is based on following conditions:
1.0m beneath the unit,1.0m from Discharge Grille.The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the Indoor Air Inlet Temperature: 27°C DB(80°F DB), 19.0°C WB(66.2°F WB) Outdoor Air Inlet Temperature: 35°C DB(95°F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter
field. When bottom air inlet is adopted,sound pressure will increase according to factors such as installation mode and the room structure. 2. The sound pressure level is based on following conditions: 1.5m beneath the unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
103/104
INDOOR UNIT Product Line

4-Way Cassette Type Mini 4-Way Cassette Type

Mini Design
Installation Direction Can be Changed Easily The unit thickness is merely 215mm leading in the industry and
for Convenient Pipe Connection the ceiling height required for installation is only 245mm. It is
extremely space saving. New appearance of the air return grille
Squared design for unit body
is honeycomb structure.
and installation bracket, 840mm Installation
bracket
unit body can be installed Drainage 570mm
pipe
in any direction horizontally
for convenient pipe connect 620mm

840mm
position. Connection 215mm
pipe

620mm

User-friendly Air Supply Mode Motion Sensor (Optional) User-friendly Air Supply Mode Motion Sensor (Optional)
The indoor unit will automatically set through Motion Sensor. The indoor unit will automatically set through Motion Sensor.
a.The unit has the breeze mode that provides miniature a.The unit has the breeze mode that provides miniature
draft through the holes at the four flat corners. This function can be achieved by the wired controllers: draft through the holes at the four flat corners. This function can be achieved by the wired controllers:
HYXE-J01H*,HYXE-VA01,HYXM-VB01*,HYXE-M01H HYXE-J01H*,HYXE-VA01,HYXM-VB01*,HYXE-M01H
b.The 4 air louvers can be controlled independently and b.The 4 air louvers can be controlled independently and
4 air speed adjustment are available to meet various 4 air speed adjustment are available to meet various
requirement. requirement.
Standard Equipped Drain Pump Standard Equipped Drain Pump
These functions can be achieved by the wired controllers: These functions can be achieved by the wired controllers:
HYXE-J01H*,HYXE-VA01,HYXM-VB01*. Standard equipped drain pump with the maximum drainage HYXE-J01H*,HYXE-VA01,HYXM-VB01*. Standard equipped drain pump with the maximum drainage
height up to 1200mm. height up to 1200mm.

Indoor unit 4-Way Cassette Type

Model Power AC1Ф, 220~240V/ AVBC-09 AVBC-12 AVBC-15 AVBC-19 AVBC-22 AVBC-24 AVBC-27 AVBC-30 AVBC-38 AVBC-48 AVBC-54 Indoor unit Mini 4-Way Cassette Type
Supply 50Hz(60Hz) HJFKA HJFKA HJFKA HJFKA HJFKA HJFKA HJFKA HJFKA HJFKA HJFKA HJFKA
Model Power AC1Ф, 220~240V/
Supply AVC-05HJFA AVC-07HJFA AVC-09HJFA AVC-12HJFA AVC-15HJFA AVC-17HJFA AVC-19HJFA
50Hz(60Hz)
kW 2.8 3.6 4.5 5.6 6.3 7.1 8.0 9.0 11.2 14.0 16.0
Nominal Cooling kW 1.5 2.2 2.8 3.6 4.5 5.0 5.6
Capacity kcal/h 2,400 3,100 3,900 4,800 5,400 6,100 6,900 7,700 9,600 12,000 13,800 Nominal Cooling
Capacity kcal/h 1,300 1,900 2,400 3,100 3,800 4,300 4,800
Btu/h 9,600 12,300 15,400 19,100 21,500 24,200 27,300 30,700 38,200 47,800 54,600
Btu/h 5,100 7,480 9,520 12,240 15,300 17,000 19,040
kW 3.2 4.0 5.0 6.3 7.1 8.0 9.0 10.0 12.5 16.0 18.0
Nominal Heating kW 2.0 2.5 3.3 4.2 5.0 5.6 6.3
Capacity kcal/h 2,500 3,400 4,300 5,400 6,100 5,900 7,700 8,600 10,800 13,800 15,500 Nominal Heating
Capacity kcal/h 1,700 2,100 2,800 3,600 4,300 4,800 5,400
Btu/h 9,900 13,600 17,100 21,500 24,200 27,300 30,700 34,100 42,700 54,600 61,400
Btu/h 6,800 8,500 11,220 14,280 17,000 19,040 21,420
Noise Level dB(A) 30/28/28/27 32/29/29/28 33/31/29/29 34/31/30/28 36/33/32/31 36/33/32/31 37/36/35/33 37/36/35/33 42/40/38/36 46/44/40/38 46/44/41/40
/26/26 /27/26 /27/26 /28/26 /29/28 /29/28 /31/30 /31/30 /34/33 /36/34 /38/36 Noise Level dB(A) 30/29/28/26 30/29/28/26 32/30/28/26 34/32/29/26 38/36/31/28 42/39/36/31 45/42/38/34
H mm 238 238 238 238 238 238 288 288 288 288 288
H mm 215 215 215 215 215 215 215
Outer Dimensions W mm 840 840 840 840 840 840 840 840 840 840 840
Outer Dimensions W mm 570 570 570 570 570 570 570
D mm 840 840 840 840 840 840 840 840 840 840 840
D mm 570 570 570 570 570 570 570
Net Weight kg 20 20 21 21 23 23 26 26 26 26 26
Net Weight kg 14.5 14.5 14.8 14.8 15.8 15.8 15.8
Air Flow Rate m3/h 876/804/720 990/840/768 1,212/960/894 1,320/1,050/954 1,530/1,200/1098 1,602/1,260/1,146 1,572/1,320/1,218 1,572/1,380/1,242 2,160/1,800/1,644 2,166/2,010/1,776 2,166/2,040/1,842
/648/600/528 /708/648/546 /816/762/672 /930/816/750 /1,020/906/780 /1,080/978/882 /1,122/1,008/924 /1,176/1,062/966 /1,488/1,344/1,176 /1,632/1,452/1,344 /1,734/1,536/1,428 Air Flow Rate m3/h 430/390/370/335 430/390/370/335 470/430/390/350 490/430/390/350 560/524/424/400 660/570/524/424 750/650/560/480
Motor Power W 60 60 60 60 60 60 60 60 127 127 127 Motor Power W 57 57 57 57 57 57 57
Piping Connections Flare-nut Connection(with Flare Nuts) Piping Connections Flare-nut Connection(with Flare Nuts)
Liquid Line mm Ф6.35 Ф6.35 Ф6.35 Ф6.35 Ф6.35 Ф9.53 Ф9.53 Ф9.53 Ф9.53 Ф9.53 Ф9.53 Liquid Line mm Ф6.35 Ф6.35 Ф6.35 Ф6.35 Ф6.35 Ф6.35 Ф6.35
Gas Line mm Ф12.7 Ф12.7 Ф12.7 Ф12.7 Ф12.7 Ф15.88 Ф15.88 Ф15.88 Ф15.88 Ф15.88 Ф15.88 Gas Line mm Ф12.7 Ф12.7 Ф12.7 Ф12.7 Ф12.7 Ф12.7 Ф12.7
Condensate Drain VP25(Outer Diameter Ф32mm) Condensate Drain VP25(Outer Diameter Ф32mm)
Panel Model HP-G-NK Panel Model HPE-D-NK
Cabinet Color Neutral White Cabinet Color Neutral White
H mm 47 47 47 47 47 47 47 47 47 47 47 H mm 37 37 37 37 37 37 37
Panel Outer Panel Outer
Dimensions W mm 950 950 950 950 950 950 950 950 950 950 950 Dimensions W mm 620 620 620 620 620 620 620
D mm 950 950 950 950 950 950 950 950 950 950 950 D mm 620 620 620 620 620 620 620
Net Weight kg 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 5.7 Net Weight kg 2.7 2.7 2.7 2.7 2.7 2.7 2.7
Packing Volume m3 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 Packing Volume m3 0.046 0.046 0.046 0.046 0.046 0.046 0.046

NOTES: NOTES:
1. The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure level is based on following conditions:1.5m beneath the unit. 1. The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure level is based on following conditions:1.5m beneath the unit.
Cooling Operation Conditions The above data was mesaured in an anechoic chamber so that reflected sound Cooling Operation Conditions The above data was mesaured in an anechoic chamber so that reflected sound
Indoor Air Inlet Temperature:27°C DB(80°F DB),19.0°C WB(66.2°F WB) should be taken into consideration in the field. Indoor Air Inlet Temperature:2°C DB(80°F DB),19.0°C WB(66.2°F WB) should be taken into consideration in the field.
Outdoor Air Inlet Temperature:35°C DB(95°F DB) Outdoor Air Inlet Temperature:35°C DB(95°F DB)
Piping Length:7.5 Meters Piping Lift:0 Meter Piping Length:7.5 Meters Piping Lift:0 Meter
Heating Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature:20°C DB(68°F DB) Indoor Air Inlet Temperature:20°C DB(68°F DB)
Outdoor Air Inlet Temperature:7°C DB(45°F DB),6°C WB(43°F WB) Outdoor Air Inlet Temperature:7°C DB(45°F DB),6°C WB(43°F WB)
105/106
INDOOR UNIT Product Line

Ceiling Ducted Type Ceiling Ducted Type


(High Static Pressure) (Low Static Pressure)

Installation Space-saving Installation Space-saving


The height less than 270mm Minimum 5mm The height less than 270mm Minimum 5mm
can be easily fit into the can be easily fit into the
limited space in the false limited space in the false
ceiling (7.5-24.2KBtu/h). 270mm ceiling (7.5-24.2KBtu/h). 270mm

7.5-24.2KBtu/h False Ceiling 7.5-24.2KBtu/h False Ceiling

Satisfying Varied Requests on Installation Fresh Indoor Air Satisfying Varied Requests on Installation Fresh Indoor Air
By introducing fresh outdoor air and being equipped with By introducing fresh outdoor air and being equipped with
the air filter to keep indoor air clean. the air filter to keep indoor air clean.

Air Supply Indoor Unit Air Supply Indoor Unit


Excellent Air Flow Excellent Air Flow
Duct The cooling and heating air distributed from the unit to the Duct The cooling and heating air distributed from the unit to the
Air Return indoor space through ducts, which creates a comfortable Air Return indoor space through ducts, which creates a comfortable
NOTE: environment. NOTE: environment.
When bottom air inlet is adopted, sound pressure will increase When bottom air inlet is adopted, sound pressure will increase
according to factors such as installation mode and the room structure. according to factors such as installation mode and the room structure.

Optional Parts Optional Parts


The drain pump can be supplied as optional part. The drain pump can be supplied as optional part.

Indoor unit Ceiling Ducted type (High Static Pressure) Indoor unit Ceiling Ducted type (Low Static Pressure)

AC1Ф, 220 AVD-07 AVD-09 AVD-12 AVD-14 AVD-17 AVD-18 AVD-22 AVD-24 AVD-27 AVD-30 AVD-38 AVD-48 AVD-54 AVD-76 AVD-96 AC1Ф, 220 AVD-07 AVD-09 AVD-12 AVD-14 AVD-17 AVD-18 AVD-22 AVD-24 AVD-27 AVD-30 AVD-38 AVD-48 AVD-54 AVD-76 AVD-96
Model Power ~240V/50Hz Model Power ~240V/50Hz UXCSAL UXCSAL UXCSAL UXCSAL UXCSBL UXCSBL UXCSBL UXCSBL UXCSCL UXCSCL UXCSCL UXCSDL UXCSDL UX6SEL*1 UX6SFL*1
UXCSAH UXCSAH UXCSAH UXCSAH UXCSBH UXCSBH UXCSBH UXCSBH UXCSCH UXCSCH UXCSCH UXCSDH UXCSDH UX6SEH*1 UX6SFH*1
Supply Supply AC1Ф, AVD-07 AVD-09 AVD-12 AVD-14 AVD-17 AVD-18 AVD-22 AVD-24 AVD-27 AVD-30 AVD-38 AVD-48 AVD-54 AVD-76 AVD-96
AC1Ф, AVD-07 AVD-09 AVD-12 AVD-14 AVD-17 AVD-18 AVD-22 AVD-24 AVD-27 AVD-30 AVD-38 AVD-48 AVD-54 AVD-76 AVD-96 220V/60Hz
220V/60Hz UX2SAH UX2SAH UX2SAH UX2SAH UX2SBH UX2SBH UX2SBH UX2SBH UX2SCH UX2SCH UX2SCH UX2SDH UX2SDH UX2SFH*2 UX2SFH*2 UX2SAL UX2SAL UX2SAL UX2SAL UX2SBL UX2SBL UX2SBL UX2SBL UX2SCL UX2SCL UX2SCL UX2SDL UX2SDL UX7SEL*2 UX7SFL*2

kW 2.2 2.8 3.6 4.3 5.0 5.6 6.3 7.1 8.4 9.0 11.2 14.2 16.0 22.4 28.0 kW 2.2 2.8 3.6 4.3 5.0 5.6 6.3 7.1 8.4 9.0 11.2 14.2 16.0 22.4 28.0
Nominal Cooling Nominal Cooling
kcal/h 1,900 2,400 3,100 3,700 4,300 4,800 5,400 6,100 7,200 7,700 9,600 12,200 13,800 19,300 24,100 Capacity kcal/h 1,900 2,400 3,100 3,700 4,300 4,800 5,400 6,100 7,200 7,700 9,600 12,200 13,800 19,300 24,100
Capacity
Btu/h 7,500 9,600 12,300 14,700 17,100 19,100 21,500 24,200 28,700 30,700 38,200 48,500 54,600 76,500 95,600 Btu/h 7,500 9,600 12,300 14,700 17,100 19,100 21,500 24,200 28,700 30,700 38,200 48,500 54,600 76,500 95,600

kW 2.8 3.3 4.2 4.9 5.6 6.5 7.5 8.5 9.6 10.0 13.0 16.3 18.0 25.0 31.5 kW 2.8 3.3 4.2 4.9 5.6 6.5 7.5 8.5 9.6 10.0 13.0 16.3 18.0 25.0 31.5
Nominal Heating
Nominal Heating
kcal/h 2,400 2,800 3,600 4,200 4,800 5,600 6,500 7,300 8,300 8,600 11,200 14,000 15,500 21,500 27,100
kcal/h 2,400 2,800 3,600 4,200 4,800 5,600 6,500 7,300 8,300 8,600 11,200 14,000 15,500 21,500 27,100
Capacity
Capacity
Btu/h 9,600 11,300 14,300 16,700 19,100 22,200 25,600 29,000 32,800 34,100 44,400 55,600 61,400 85,300 107,500
Btu/h 9,600 11,300 14,300 16,700 19,100 22,200 25,600 29,000 32,800 34,100 44,400 55,600 61,400 85,300 107,500
Noise Level
Noise Level (H/M/L) dB(A) 30-26-24 30-26-24 32-30-28 32-30-28 33-31-29 33-31-29 34-32-30 34-32-30 38-34-30 38-34-30 39-35-31 41-38-33 43-39-34 50 52
(H/M/L) dB(A) 33-31-29 33-31-29 33-31-29 33-31-29 34-32-30 34-32-30 36-34-32 36-34-32 41-39-34 41-39-34 43-40-36 44-41-36 43-40-37 52 54
H mm 270 270 270 270 270 270 270 270 350 350 350 350 350 470 470
H mm 270 270 270 270 270 270 270 270 350 350 350 350 350 470 470
Outer W mm 650+75 650+75 650+75 650+75 900+75 900+75 900+75 900+75 900+75 900+75 900+75 1300+75 1300+75 1060 1250
Outer W mm 650+75 650+75 650+75 650+75 900+75 900+75 900+75 900+75 900+75 900+75 900+75 1300+75 1300+75 1060 1250 Dimensions
Dimensions
D mm 720 720 720 720 720 720 720 720 800 800 800 800 800 1120 1120
D mm 720 720 720 720 720 720 720 720 800 800 800 800 800 1120 1120
Net Weight kg 25 25 25 25 34 34 34 34 44 44 44 56 56 94 106
Net Weight kg 25 25 25 25 34 34 34 34 44 44 44 56 56 94 106 Air Flow Rate 480/420 480/420 780/660 780/660 900/780 900/780 960/840 960/840 1550/1350 1550/1350 1550/1350 2150/1800 2200/1900
Air Flow Rate 480/420 480/420 780/660 780/660 900/780 900/780 960/840 960/840 1600/1400 1600/1400 1600/1400 2100/1750 2150/1800 (H/M/L) m3/h 3480 4320
m3/h 3480 4650 /360 /360 /540 /540 /660 /660 /720 /720 /1150 /1150 /1150 /1500 /1500
(H/M/L) /360 /360 /540 /540 /660 /660 /720 /720 /1150 /1150 /1150 /1450 /1550 Motor Power W 110 110 150 150 150 150 150 190 300 300 300 430 430 950 1120
Motor Power W 110 110 150 150 150 150 150 190 300 300 300 430 430 1030 1280
Piping Connections Flare-nut Connection(with Flare Nuts) Brazing
Piping Connections Flare-nut Connection(with Flare Nuts) Brazing
Liquid Line mm Ф6.35 Ф6.35 Ф6.35 Ф6.35 Ф6.35 Ф6.35 Ф9.53 Ф9.53 Ф9.53 Ф9.53 Ф9.53 Ф9.53 Ф9.53 Ф9.53 Ф9.53
Liquid Line mm Ф6.35 Ф6.35 Ф6.35 Ф6.35 Ф6.35 Ф6.35 Ф9.53 Ф9.53 Ф9.53 Ф9.53 Ф9.53 Ф9.53 Ф9.53 Ф9.53 Ф9.53
Gas Line mm Ф12.7 Ф12.7 Ф12.7 Ф12.7 Ф15.88 Ф15.88 Ф15.88 Ф15.88 Ф15.88 Ф15.88 Ф15.88 Ф15.88 Ф15.88 Ф19.05 Ф22.2
Gas Line mm Ф12.7 Ф12.7 Ф12.7 Ф12.7 Ф15.88 Ф15.88 Ф15.88 Ф15.88 Ф15.88 Ф15.88 Ф15.88 Ф15.88 Ф15.88 Ф19.05 Ф22.2
Condensate Drain VP25(Outer Diameter Ф32 )
Condensate Drain VP25(Outer Diameter Ф32 )
External Static
External Static Pressure Pa 30 30 30 30 30 30 30 30 60 60 60 60 60 100 100
Pressure Pa 50(80) 50(80) 50(80) 50(80) 50(80) 50(80) 50(80) 50(80) 120(90) 120(90) 120(90) 120(90) 120(90) 220 220
3
Packing Volume m 0.21 0.21 0.21 0.21 0.27 0.27 0.27 0.27 0.38 0.38 0.38 0.52 0.52 0.90 1.06
Packing Volume m3 0.21 0.21 0.21 0.21 0.27 0.27 0.27 0.27 0.38 0.38 0.38 0.52 0.52 0.90 1.06

NOTES: NOTES:
1.The nominal cooling capacity and heating capacity are based on following 2. The sound pressure level is based on following conditions: 1.5m beneath the unit. 1.The nominal cooling capacity and heating capacity are based on following 2. The sound pressure level is based on following conditions: 1.5m beneath the unit.
conditions: With discharge duct (2.0m) and return duct(1.0m) conditions: With discharge duct (2.0m) and return duct(1.0m)
Cooling Operation Conditions The above data was measured in an anechoic chamber so that reflected sound Cooling Operation Conditions The above data was measured in an anechoic chamber so that reflected sound
Indoor Air Inlet Temperature: 27°C DB(80°F DB), 19.0°C WB(66.2°F WB) should be taken into consideration in the field. Indoor Air Inlet Temperature: 27°C DB(80°F DB), 19.0°C WB(66.2°F WB)
should be taken into consideration in the field.
Outdoor Air Inlet Temperature: 35°C DB(95°F DB) Outdoor Air Inlet Temperature: 35°C DB(95°F DB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter 3. When bottom air inlet is adopted, sound pressure will increase according to factors Piping Length: 7.5 Meters Piping Lift: 0 Meter
Heating Operation Conditions such as installation mode and the room structure. Heating Operation Conditions 3. When bottom air inlet is adopted, sound pressure will increase according to factors
Indoor Air Inlet Temperature: 20°C DB(68°F DB) *1: AC3Φ, 380V/50Hz, Indoor Air Inlet Temperature: 20°C DB(68°F DB) such as installation mode and the room structure.
Outdoor Air Inlet Temperature: 7°C DB(45°F DB), 6°C WB(43°F WB) *2: AC3Φ, 380V/60Hz: AVD- 76UX7SEH; AVD-96UX7SFH Outdoor Air Inlet Temperature: 7°C DB(45°F DB), 6°C WB(43°F WB) *1: AC3Φ, 380V/50Hz, *2: AC3Φ, 380V/60Hz
107/108
INDOOR UNIT Product Line

Ceiling Ducted Type Ceiling Ducted Type


(AC Low-height) (DC Low-height)

Installation Space-saving 700mm


447mm
Installation Space-saving 700mm
447mm

192mm With the height is 192mm and the 192mm


192mm With the height is 192mm and the 192mm
smallest depth is 447mm, it can smallest depth is 447mm, it can
make full use of the narrow space make full use of the narrow space
to realize various kinds of air flow. to realize various kinds of air flow.

Window Contact Design Window Contact Design


The operation condition of the unit links with the window The operation condition of the unit links with the window
The Unit Can Be Controlled Automatically The Unit Can Be Controlled Automatically
status through the window sensor and the Hisense indoor status through the window sensor and the Hisense indoor
unit input function. This function saves energy and the Through The Hi Motion. unit input function. This function saves energy and the Through The Hi Motion.
automatic switch setting provides convenience for users. This function can be achieved by the wired controller: automatic switch setting provides convenience for users. This function can be achieved by the wired controller:
HYXE-J01H*,HYXM-VB01* HYXE-J01H*,HYXM-VB01*

Humidity Sensor Achieves The Automatic Humidity Sensor Achieves The Automatic
Dehumidification. Dehumidification.
This function can be achieved by the wired controller: This function can be achieved by the wired controller:
HYXE-J01H*,HYXE-VA01,HYXM-VB01*,HYXE-M01H HYXE-J01H*,HYXE-VA01,HYXM-VB01*,HYXE-M01H

Wider 3D-air Flow Range Wider 3D-air Flow Range


This function can be achieved by the wired controller: This function can be achieved by the wired controller:
Broad air deflector design realized broad air supply range. Broad air deflector design realized broad air supply range.
HYXE-VA01,HYXM-VB01,HYXE-J01H HYXE-VA01,HYXM-VB01,HYXE-J01H
The wind direction can be adjusted accordingto the need The wind direction can be adjusted accordingto the need
Standard Equipped Drain Pump thus makes the customers feel more comfortable. Standard Equipped Drain Pump thus makes the customers feel more comfortable.
Standard equipped drain pump with the maximum drainage This function can be achieved by the wired controller: Standard equipped drain pump with the maximum drainage This function can be achieved by the wired controller:
height up to 1200mm. HYXE-J01H*,HYXE-VA01,HYXM-VB01*,HYXE-M01H height up to 1200mm. HYXE-J01H*,HYXE-VA01,HYXM-VB01*,HYXE-M01H

Indoor unit Celing Ducted Type (AC Low-height) Indoor unit Celing Ducted Type (DC Low-height)
Model Power supply AC 1Ф, 220~240V DC 1Ф,220~240V
AVE-05HCFRL AVE-07HCFRL AVE-09HCFRL AVE-12HCFRL AVE-15HCFRL AVE-17HCFRL AVE-19HCFRL AVE-22HCFRL AVE-24HCFRL Model Power supply
/50Hz AVE-05HJFDL AVE-07HJFDL AVE-09HJFDL AVE-12HJFDL AVE-15HJFDL AVE-17HJFDL AVE-19HJFDL AVE-22HJFDL AVE-24HJFDL
/50Hz(60Hz)
kW 1.7 2.2 2.8 3.6 4.5 5.0 5.6 6.3 7.1
Nominal Cooling kW 1.7 2.2 2.8 3.6 4.5 5.0 5.6 6.3 7.1
Capacity kcal/h 1,500 1,900 2,400 3,100 3,900 4,300 4,800 5,400 6,100
Nominal Cooling
5,800 7,500 9,600 12,300 15,300 17,100 19,100 21,500 24,200 Capacity kcal/h 1,500 1,900 2,400 3,100 3,900 4,300 4,800 5,400 6,100
Btu/h
kW 1.9 2.5 3.2 4.0 5.0 5.6 6.3 7.1 8.0 Btu/h 5,800 7,500 9,600 12,300 15,300 17,100 19,100 21,500 24,200

Nominal Heating 1,700 2,100 2,700 3,450 4,300 4,800 5,400 6,100 6,800 kW 1.9 2.5 3.2 4.0 5.0 5.6 6.3 7.1 8.0
kcal/h
Capacity Nominal Heating
6,500 8,500 11,300 13,600 17,100 19,100 21,500 24,200 27,300 kcal/h 1,700 2,100 2,700 3,450 4,300 4,800 5,400 6,100 6,800
Btu/h Capacity
Noise Level Sound Pressure- Btu/h 6,500 8,500 11,300 13,600 17,100 19,100 21,500 24,200 27,300
(Hi/Me/Lo) dB(A) 29/24/22 29/24/22 35/25/23 35/25/23 36/25/23 36/25/23 35/25/23 39/26/25 39/26/25
Noise Level Sound Pressure-
192 192 192 192 192 192 192 192 192 dB(A) 28/27/26/24/23/21 28/27/26/24/23/21 35/32/32/30/26/23 35/32/32/30/26/23 35/32/32/30/26/23 35/32/32/30/26/23 35/32/30/28/25/23 38/36/35/33/31/24 38/36/35/33/31/24
H mm
H mm 192 192 192 192 192 192 192 192 192
Outer Dimensions W mm 700 700 700 700 910 910 1,180 1,180 1,180
Outer Dimensions W mm 700 700 700 700 910 910 1180 1,180 1,180
D mm 447 447 447 447 447 447 447 447 447

Net Weight kg 16 16 17 17 21 21 25 26 26 D mm 447 447 447 447 447 447 447 447 447

Air Flow Rate m /h Net Weight kg 16 16 17 17 20 20 24 24 24


(Hi/Me/Lo)
3
420/330/282 420/330/282 540/342/288 540/342/288 720/378/330 720/378/330 810/480/462 1,080/558/522 1,080/558/522
Motor Power W 14 14 29 29 35 35 40 60 60 Air Flow Rate 420/390/366/ 420/390/366/ 540/486/438/ 540/486/438/ 720/648/564/ 720/648/564/ 810/750/672/ 1,080/966/858/ 1,080/966/858/
m3 /h
342/318/288 342/318/288 402/354/312 402/354/312 486/408/330 486/408/330 600/528/462 738/630/522 738/630/522
Piping Connections Flare-nut Connection(with Flare Nuts)
Motor Power W 40 40 40 40 40 40 60 60 60
Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.53 Φ9.53
Piping Connections Flare-nut Connection(with Flare Nuts)
Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88
Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.53 Φ9.53
Condensate Drain VP25(Outer Diameter Ø32mm)
Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88
External Pressure Pa 10(30)
Approximate Packing Condensate Drain VP25(Outer Diameter Ø32mm)
Measurement
m3 0.15 0.15 0.15 0.15 0.18 0.18 0.22 0.22 0.22
External Pressure Pa 10(0-10-30)
Approximate Packing
Measurement m3 0.15 0.15 0.15 0.15 0.18 0.18 0.22 0.22 0.22
NOTES:
1. The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure level is based on following conditions:1.5m beneath the unit. NOTES:
Cooling Operation Conditions The above data was mesaured in an anechoic chamber so that reflected sound 1. The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure level is based on following conditions:1.5m beneath the unit.
Indoor Air Inlet Temperature:27oC DB(80oF DB),19.0oC WB(66.2oF WB) should be taken into consideration in the field. Cooling Operation Conditions The above data was mesaured in an anechoic chamber so that reflected sound
Outdoor Air Inlet Temperature:35oC DB(95oF DB) Indoor Air Inlet Temperature:27oC DB(80oF DB),19.0oC WB(66.2oF WB) should be taken into consideration in the field.
Piping Length:7.5 Meters Piping Lift:0 Meter Outdoor Air Inlet Temperature:35oC DB(95oF DB)
Heating Operation Conditions Piping Length:7.5 Meters Piping Lift:0 Meter
Indoor Air Inlet Temperature:20oC DB(68oF DB) Heating Operation Conditions
Outdoor Air Inlet Temperature:7oC DB(45oF DB),6oC WB(43oF WB) Indoor Air Inlet Temperature:20oC DB(68oF DB)
Outdoor Air Inlet Temperature:7oC DB(45oF DB),6oC WB(43oF WB)
109/110
INDOOR UNIT Product Line

Ceiling & Floor Type Wall Mounted Type

Flexible Installation
The Design of Elegant Smooth Panel with Hidden
The unit can be installed either standing on the floor or LED Display
hanging under the ceiling.
The quality of “Elegance” is to meet contemporary needs. The simple
and smooth form harmonizes with any interior style. The smooth panel
can be cleaned easily.

Convenient Installation and Maintenance


Advanced structure design that makes the unit installatioin,
pipe connection, even wiring work into simple.
under the ceiling Compact and Light Weight, Allowing Easy Installation
Power supply
For easy installation, a slim design is adopted to this new
Side panel
*The wireless remote controller HYE-W01 is model by using a high proportion of lightweight resin parts,
standard for Wall Mounted Type. which greatly reduced the weight of the unit.
*The wireless remote controller HYE-W01 is Liquid Line
standard for Ceiling & Floor Type.
on the floor Gas Line terminal
Anti-mold Filter The Sleep Mode Offers Comfortable
1. Unit installation work can be done directly 2. After open side panel, big 3. Set DIP switch by
Anti-mold filter is equipped as standard accessory.
Temperature for People to Enjoy Good Sleep
just open the side panel space for pipe connection opening electric box
provide convenience for cover, simple and The sleep mode can be kept for 8 hours. The setting
pipe installation convenience.
temperature can be adjusted automatically for your comfort.
New Fashion Design Appearance
and High Quality Wider 3D-air Flow Range Free Installation
The fashionable design and streamline appearance gives Broad air deflector design realized broad air supply range. The water drain pipe can be set either on the left side or on Quiet Operation for Super Low Sound Level
a perfect choice for users.The integrative side panel The wind direction can be adjusted according to the need the right side of the unit. The connection pipe can be set in The one-touch quiet operation can set the system work in a
makes the whole unit more concordant.big air outlet with thus makes the customers feel more comfortable. left, right or back side of the unit. super low speed and make the noise level low to 28 dB(A).
an integrative large louver realizes high air volume and
low noise.

Indoor unit Ceiling & Floor Type Indoor unit Wall Mounted Type
Model Power AC1Φ 220V~240V AVV-17URSCA AVV-18URSCA AVV-22URSCA AVV-24URSCA AVV-27URSCB AVV-30URSCB AVV-38URSCB AVV-48URSCC
Model Power
AC1Φ220V AVS-07URCSABA AVS-09URCSABA AVS-12URCSABA AVS-14URCSABA AVS-17URCSABA AVS-18URCSBBA AVS-22URCSBBA AVS-24URCSBBA
50Hz/60Hz ~240V/50Hz
Supply Supply
AVV-17UR2SA AVV-18UR2SA AVV-22UR2SA AVV-24UR2SA AVV-27UR2SB AVV-30UR2SB AVV-38UR2SB AVV-48UR2SC AC1Φ220V/ AVS-18UR2SBBA AVS-22UR2SBBA AVS-24UR2SBBA
60Hz AVS-07UR2SABA AVS-09UR2SABA AVS-12UR2SABA AVS-14UR2SABA AVS-17UR2SABA
kW 5 5.6 6.3 7.1 8.4 9 11.2 14.2 Nominal Cooling kW 2.2 2.8 3.6 4.0 5.0 5.6 6.3 7.1
Nominal Cooling Capacity kcalh 1,900 2,400 3,100 3,450 4,300 4,816 5,418 6,106
Capacity kcal/h 4,300 4,800 5,400 6,100 7,200 7,700 9,600 12,200
Btu/h 7,500 9,500 12,300 13,600 17,000 19,100 21,500 24,200
Btu/h 17,100 19,100 21,500 24,200 28,700 30,700 38,200 48,500 kW 2.5 3.3 4.0 4.5 5.6 6.3 7.1 8
Nominal Heating
Capacity kcalh 2,150 2,800 3,450 3,900 4,800 5,418 6,106 6,880
kW 5.6 6.5 7.5 8.5 9.6 10 13 16.3 Btu/h 8,500 11,100 13,600 15,300 19,100 21,500 24,200 27,300
Nominal Heating Air Flow Rate
kcal/h 4,800 5,600 6,500 7,300 8,300 8,600 11,200 14,000 (High/Medium/Low/Mute) m3/h 660/590/520/460 660/590/520/460 830/660/520/460 830/660/520/460 900/750/590/460 893/782/671/582 1,006/893/716/621 1,122/984/804/649
Capacity
Noise Level
Btu/h 19,100 22,200 25,600 29,000 32,800 34,100 44,400 55,600 (High/Medium/Low/Mute) dB(A) 39/34/32/28 39/34/32/28 43/39/32/28 43/39/32/28 45/40/34/29 41/37/34/30 44/41/36/31 46/43/38/33

Motor Power W 40 40 70 70 70 80 130 160 Net Weight kg 13.5 13.5 13.5 13.5 13.5 16.0 16.0 16.0
Air Flow Rate m3/h Motor Power W 50 50 60 60 65 62 72 82
(H/M/L) 780/660/540 780/660/540 966/840/678 966/840/678 1,092/912/732 1,164/978/798 1,488/1,230/978 1,980/1,680/1,380
Connections Flare-nut Connection(with Flare Nuts)
Noise Level (Ceiling) dB(A) 39/35/30 39/35/30 45/41/37 45/41/37 43/39/34 45/40/36 51/46/40 50/46/42 Refrigerant Piping

Noise Level (Floor) dB(A) 43/38/35 48/44/40 48/44/40 46/41/37 48/43/39 54/49/43
Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.53 Φ9.53 Φ9.53
43/38/35 55/50/46
mm
Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88
H 230 230 230 230 230 230 230 230
Outer Condensate Drain VP16(Outer Diameter Φ32)
Dimensions W mm 990 990 990 990 1,285 1,285 1,285 1,580
mm H mm 315 315 315 315 315 315 315 315
D 680 680 680 680 680 680 680 680
Outer Dimensions W mm 960 960 960 960 960 1,120 1,120 1,120
Net Weight kg 31 31 32 32 39 40 41 47
D mm 230 230 230 230 230 230 230 230
Piping Flare-nut Connection(with Flare Nuts)
Connections Packing Volume m3 0.17 0.17 0.17 0.17 0.17 0.19 0.19 0.19
Liquid Line mm Φ6.35 Φ6.35 Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53 Wireless Remote
HYE-L01+Receiver
Controller/Receiver
Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Wired Remote Controller Option Option Option Option Option Option Option Option
Condensate Drain VP25(Outer Diameter Φ32) Fan motor PG Fan motor PG Fan motor PG Fan motor PG Fan motor PG Fan motor PG Fan motor PG Fan motor PG Fan motor
Speed-up Setting Drain Pump NO NO NO NO NO NO NO NO
HH1 m3/h 852 852 1,068 1,068 1,188 1,272 1,620 2,160
Speed-up Setting
HH2 m3/h 960 960 1,200 1,200 1,338 1,410 1,752 2,244 NOTES:
1.The nominal cooling capacity and heating capacity are based on following conditions: 2. The sound pressure level is based on following conditions:
NOTES: Cooling Operation Conditions 1.0m beneath the unit and 1.0m from inlet grille.
Indoor Air Inlet Temperature: 27°C DB(80°F DB), 19.0°C WB(66.2°F WB) Voltage of the power source for the indoor fan motor is 220V.
1.The nominal cooling capacity and heating capacity are based on following condations: 2. The sound pressure level is based on following condations: In case of the power sourse of 240V, the sound pressure level increases by about
Cooling Operation Condations 1.0m beneath the unit,1.0m from Discharge Grille. Outdoor Air Inlet Temperature: 35°C DB(95°F DB)
1~2dB.
Indoor Air Inlet Temperature: 27°C DB(80°F DB)19°C WB(66.2°F DB) The above data was measured in an anechoic chamber so that reflected Piping Length: 7.5 Meters Piping Lift: 0 Meter
The above data was measured in an anechoic chamber so that reflected sound
Outdoor Air Inlet Temperature: 35°C DB(95°F DB) sound should be taken into consideration in the field. When bottom air inlet is Heating Operation Conditions should be taken into consideration in the field.
Piping Length: 5.0Meter Piping Lift: 0Meter adopted,sound pressure will increase according to factors such as installation mode Indoor Air Inlet Temperature: 20°C DB(68°F DB)
Heating Operation Condations and the room structure. Outdoor Air Inlet Temperature: 7°C DB(45°F DB), 6°C WB(43°F WB)
Indoor Air Inlet Temperature: 20°C DB(68°F DB)
Outdoor Air Inlet Temperature:7°C DB(45°F DB)6°C DB(43°F DB)
111/112
INDOOR UNIT Product Line

Floor Concealed Type Console Type

New Appearance Design


Compact Design Fitting Into a Tiny Space
The unit adopts the fashionable appearance with suspension
The design places special emphasis on the compatibility with the interior flat design and realizes digital display function.
design as well as space saving design, allowing it to fit perfectly into the
space below a bay window. So compact that it fits into even a tiny space.

Perfectly Fit The Indoor Decoration Two-level Static Pressure Available


No matter what kind of decoration style it is, Hisense floor High static pressure achieves long distance air exhaust.
concealed type can be able to match it. The air can be reach to every part of the room.

Hidden Installation, Space Saving The Unit Can Be Controlled Automatically High Efficiency and More Options
Hisense floor concealed type can be installed in the decoration Through The Hi Motion (Optional). DC Fan motor realizes high efficiency with 6 air flow speed
space, which is covered by the decoration. This function can be achieved by the wired controller: adjustments to provide more options for customers.
HYXE-J01H*,HYXM-VB01*

Humidity Sensor Achieves The Automatic


Indoor unit Floor Concealed Type Dehumidification (Optional). *The wireless remote controller HYE-W01 is
standard for Console Type.
This function can be achieved by the wired controller:
AC1Ф, 220~240V/50Hz AVH-09UXCSAA AVH-14UXCSAA AVH-18UXCSBA AVH-24UXCSBA HYXE-J01H*,HYXE-VA01,HYXM-VB01*,HYXE-M01H
Model Power Supply
AC1Ф, 220V/60Hz AVH-09UX2SAA AVH-14UX2SAA AVH-18UX2SBA AVH-24UX2SBA

kW 2.8 4.3 5.6 7.1 Indoor unit Console Type


Nominal Cooling Capacity kcal/h 2,400 3,700 4,800 6,100
Model Power Supply AC 1Φ, 220~240V/50Hz AVK-05HJFCAA AVK-07HJFCAA AVK-09HJFCAA AVK-12HJFCAA AVK-15HJFCAA AVK-17HJFCAA
(60Hz)
Btu/h 9,600 14,700 19,100 24,200
kW 1.5 2.2 2.8 3.6 4.5 5.0
kW 3.3 4.9 6.5 8.5 Nominal Cooling
Capacity kcal/h 1,300 1,900 2,400 3,100 3,800 4,300

Nominal Heating Capacity kcal/h 2,800 4,200 5,600 7,300 Btu/h 5,100 7,500 9,600 12,300 15,300 17,000

kW 2.0 2.5 3.3 4.2 5.0 5.6


Btu/h 11,300 16,700 22,200 29,000 Nominal Heating
Capacity kcal/h 1,700 2,100 2,800 3,600 4,300 4,800
Noise Level (H/M/L) dB(A) 34-31-27 40-36-34 41-36-32 44-40-36 Btu/h 6,800 8,500 11,200 14,300 17,000 19,100
Cabinet Color Silky White Noise Level
dB(A) 32/30/29/28/26/24 34/32/31/29/27/26 36/35/32/31/29/27 39/36/34/31/29/27 41/39/37/35/33/32 44/43/41/39/37/36
(HH2/HH1/Hi/Me/Lo/Slo)
H mm 620 620 620 620 H mm 630 630 630 630 630 630
Outer Dimensions W mm 700 700 700 700 700 700
Outer Dimensions W mm 948+139 948+139 1,218+139 1,218+139
D mm 225 225 225 225 225 225
D mm 202 202 202 202
Net Weight kg 16.1 16.1 16.1 17.4 17.4 17.4
Net Weight kg 18 22 26 27 Air Flow Rate 360/342/318 444/420/384 480/444/420 492/456/408 540/510/468 606/582/540
(HH2/HH1/Hi/Me/Lo/Slo) m 3 /h
/306/282/270 /360/336/318 /384/360/336 /372/342/318 /432/396/384 /510/474/438
Air Flow Rate (H/M/L) m3/h 510/450/380 620/540/480 890/740/630 980/830/710
Motor Power W 10 11 12 14 18 23
Motor Power W 50 80 90 120
Piping Connections Flare-nut Connection (with Flare Nuts)
Piping Connections Flare-nut Connection(with Flare Nuts)
Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35
Liquid Line mm
Liquid Line mm Ф6.35 Ф6.35 Ф6.35 Ф9.53 Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ12.7

Gas Line Condensate Drain mm Outer Diameter Φ18


mm Ф12.7 Ф12.7 Ф15.88 Ф15.88
Cabinet Color Pure White
Condensate Drain VP25 VP25 VP25 VP25
Packing Volume m3 0.18 0.18 0.18 0.18 0.18 0.18
Packing Volume m3 0.19 0.19 0.23 0.23

NOTES:
NOTES: 1.The nominal cooling capacity and heating capacity are based on following conditions: 2.The sound pressure level is based on following conditions:
Cooling Operation Conditions It is measured in anechoic room. Operation noise
1.The nominal cooling capacity and heating capacity are based on following conditions: 2.The sound pressure level is based on following conditions:
Indoor Air Inlet Temperature: 27°C DB(80°F DB), 19.0℃ WB(66.2°F WB) differs with operation and ambientconditions.
Cooling Operation Conditions 1.5m meters from the unit and 1.5m meters from floor level.
Outdoor Air Inlet Temperature: 35°C DB(95°F DB) Location of Microphone:
Indoor Air Inlet Temperature: 27°C DB(80°F DB), 19.0°C WB(66.2°F WB) The above data was measured in an anechoic chamber so that reflected sound Microphone
Piping Length: 7.5 Meters Piping Lift: 0 Meter
Outdoor Air Inlet Temperature: 35°C DB(95°F DB) should be taken into consideration in the field.
Heating Operation Conditions
Piping Length: 7.5 Meters Piping Lift: 0 Meter 1m
Indoor Air Inlet Temperature: 20°C DB(68°F DB)
Heating Operation Conditions
Outdoor Air Inlet Temperature: 7°C DB(45°F DB), 6°C WB(43°F WB)
Indoor Air Inlet Temperature: 20°C DB(68°F DB) 1m
Outdoor Air Inlet Temperature: 7°C DB(45°F DB), 6°C WB(43°F WB)
113/114
VENTILATION SOLUTION​

Product Line

All Fresh Air Indoor Unit All Fresh Air Indoor Unit
(For S/G+/X/R/H/W Series)

Create Comfortable and Healthy Indoor Environment Flexible Line-up to Hi-FLEXi Series
Create a comfortable and healthy indoor environment by and Hi-Smart Series Indoor unit All Fresh Air Indoor Unit
introducing fresh outdoor air. By heating or cooling fresh outdoor
All fresh air indoor units are applicable to Hi-FLEXi S, AC3Ф, 380~ AVA-114 AVA-154 AVA-190 AVA-190
air to almost the same temperature as room temperature, fresh Model 415V/50Hz UX6SRH-300 UX6SSH-400 UX6STH-500 UX6STH-600
ambient air can be adapted and then introduced into indoor room. G+,X,R,W and Hi-Smart H Series outdoor units. General Power Supply AC3Ф, AVA-114 AVA-154 AVA-190 AVA-190
Besides, after filtered, fresh outdoor air in transition seasons indoor units and all fresh air indoor units can be used 380V/60Hz UX7SRH-300 UX7SSH-400 UX7STH-500 UX7tSTH-600
can be drawn to indoor room directly with no need of heating or together in Hi-FLEXi S, G+,X,R,W and Hi-Smart H Series Combined Outdoor Unit Model Hi-FLEXi S/G+/X/R/W Series Hi-Smart H Series
cooling operation, While fresh outdoor air is introduced, other system.
kW 33.5 45.0 56.0 56.0
indoor units don’t bear fresh air load.
Advanced Contol Cooling Capacity kcal/h 28,800 38,700 48,200 48,200
Higher External Static Pressure Can be interfaced to central control system. Easy
Btu/h 114,300 153,600 191,100 191,100
Better installation flexibility at site, longer duct can be connected. electrical wiring design and installation.
kW 26.8 36.0 44.8 44.8

Heating Capacity kcal/h 23,100 31,000 38,500 38,500

Btu/h 91,500 122,900 152,900 152,900


Motor Power W 740 1120 1330 1620

H mm 486 635 735 735


Outer Dimensions W mm 1,270 1,950 1,950 1,950

D mm 1,069 805 805 805


Sound Pressure Level dB(A) 56 61 64 66

Indoor unit All Fresh Air Indoor Unit Net Weight Kg 97 196 222 222
Model AC1Ф, 220~ AVA-30UXCSCH-70 AVA-48UXCSQH-108 AVA-76UXCSRH-168 AVA-96UXCSRH-210
240V/50Hz Refrigerant R410A
Power Supply AC1Ф, AVA-30UX2SCH-70 AVA-48UX2SQH-108 AVA-76UX2SRH-168 AVA-96UX2SRH-210
220 V/60Hz Indoor Fan Air Flow Rate m /h
3
3,000 4,000 5,000 6,000
Combined Outdoor Unit Model Hi-FLEXi S/G+/X/R/W Series Hi-Smart H Series
External Static Pressure Pa 220 300 320 300
kW 9.0 14 .0 22.4 28.0
Air Inlet Size mm 1,100×415 1,522×522 1,522×622 1,522×622
Nominal Cooling Capacity kcal/h 7,700 12,000 19,300 24,100
Btu/h Air Outlet Size mm 1,106×338 850×272 850×272 850×272
30,700 47,800 76,500 95,600
kW 8.6 13.7 21.9 24.5 Drain Pipe Size VP25,Outer Diameter: Φ32mm RC1(Internal Screw)

Nominal Heating Capacity kcal/h 7,400 11,800 18,800 21,100 Refrigerant Liquid Line Size mm Ф12.7 Ф12.7 Ф15.88 Ф15.88
Btu/h 29,400 46,800 74,700 83,600 Refrigerant Gas Line Size mm Ф25.4 Ф25.4 Ф28.6 Ф28.6
Motor Power W 150 330 490 510
Temperature Range of Fresh Air Drawn Cooling: 20°C~43°C, Heating: -7°C~15°C
H mm 370 370 486 486
Outer Dimensions W mm 920 1,320 1,270 1,270
mm
NOTES:
D 800 800 1,069 1,069
1.The nominal cooling capacity and heating capacity are based on following conditions
Noise Level dB(A) 32 43 45 46 Cooling operation conditions: 33°C DB, 28°C WB, piping length: 7.5m, piping lift: 0m
Net Weight Kg Heating operation conditions: 0°C DB, -9°C WB, piping length: 7.5m, piping lift: 0m
46 60 97 97
(Heating capacity is tested when defrosting is not available )
Refrigerant R410A(Nitrogen-charged for Corrosion-resistance) 2.The sound pressure level is based on following conditions: 1.5 Meter beneath the unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the filed.
Air Flow Rate m3/h 660 1,080 1,680 2,100 3.An air filter with duct collection efficiency more than 50% needs to be attached to the duct system of the suction side at site.
External Static Pressure Pa 4.When the resistance of the filed-supplied duct is small, it may cause abnormal stop, malfunction, spraying water, etc.Due to excessive air flow. And the duct, which
60(120) 200 220 220
is to be connected to this unit, shall be insulation for dew protection.
Air Inlet Size mm 833×306 1233×306 1,100×415 1,100×415 5.All fresh air indoor unit is for processing fresh air load and not for stabilizing the room temperature. For adjusting the air conditioning load of the room, the additional
air conditioner is required.
Air Outlet Size mm 803×220 1203×220 1,106×338 1,106×338 6.This unit shall be connected to Hi-FLEXi S, G+,X,R,W and Hi-Smart H Series outdoor units. In case of connecting this unit with other indoor units in the same
Drain Pipe Size refrigerant cycle,calculate the capacity of this unit as 46.1KBtu/h(30.7KBtu/h), 71.7KBtu/h(47.8KBtu/h), 143.3KBtu/h(95.6KBtu/h).
VP25, Outer Diameter: Ф32mm
7.When Hi-Flexi outdoor unit connected to only with all fresh air indoor unit, the configuration rate is 100% (Recommended ).
Refrigerant Liquid Line mm Ф9.53 Ф9.53 Ф9.53 Ф9.53 8.Under cooling mode,when outdoor temperature is lower than 20℃ ,the system will automatically shift to ventilation operation; Under heating mode, when outdoor
temperature is higher than 15°C the system will automatically shift to ventilation operation; In case inlet temperature is below -7°C all fresh air unit will stop.
Refrigerant Gas Line mm Ф15.88 Ф15.88 Ф19.05 Ф22.2
Temperature Range of Fresh Air Drawn Cooling: 20°C~43°C, Heating: -7°C~15°C
115/116
VENTILATION SOLUTION​

Product Line

Heat Recovery Energy Saving Analysis


Ventilator VS ordinary
Summer Energy Saving Analysis ventilation fan

Total heat exchanger mode Air inlet Outdoor air

Total heat exchanger Total heat Traditional Dry bulb


35
exchanger ventilation fan temperature °C
Dry bulb Wet bulb
Outdoor
temperature °C 29.4 35 temperature °C 28
discharge air
Build a More Comfortable, Healthy and Energy-saving Living Space, 32.6°C
Wet bulb
temperature °C
Moisture content
23.3 28
Relative humidity
%
59.1

15.7 21.1 Enthalpy value 89.4


Hisense High-performance Heat Recovery Ventilator
kJ/kg(DA)
g/kg
Relative humidity
Room Outdoor air % 60.1 59.1
temperature 27°C 35°C
Enthalpy
value kJ/kg(DA) 69.8 89.4
Outdoor fresh air 29.4°C
Recycling coldkW 1.57 0
Hisense heat recovery ventilator adopts efficient convective transfer material after heat exchange Heat loadkW 2.8 2.8

to effectively recycle the heat losses due to ventilation, reduces the fresh air Indoor air Discharge air

load, achieves the purpose of energy saving and lower running cost of air
conditioning unit, fresh air is supplied to indoors continuously which can make In summer operation, when the cold energy of 27°C air discharged
Dry bulb
from indoor pass through the heat exchanger, the 35°C outdoor temperature °C 27
your room more comfortable and healthy. hot air is pre-cooled to 29. 4°C fresh air and supplied to indoors,
Air Wet bulb
temperature °C
19.5
conditioning
Relative humidity 49.8
as shown above, the air conditioner only needs to cool the air by %
Enthalpy value kJ/kg(DA) 55.5
2.4°C to maintain a comfortable room temperature and fresh air.
In this process, the discharge air pre-cools the fresh air by HRV,
The temperature recovery efficiency in cooling is 70% max, and
enthalpy exchange efficiency is 57% max.
VS ordinary
Basic Structure and Operation Principle Winter Energy Saving Analysis ventilation fan

Total heat exchanger mode


Air inlet Outdoor air
Total heat exchanger
Dirty air exhausted Fan Motor Total heat
exchanger
Traditional
ventilation fan
Dry bulb
5
temperature °C
Outdoor
Dry bulb Wet bulb
discharge air 17 5 2
Heat exchanger core 9°C
temperature °C temperature °C
Outdoor fresh air Wet bulb
9.4 2 Relative humidity 58.5
temperature °C %
Moisture content
g/kg 4.2 6 Enthalpy value kJ/kg(DA) 12.9
Room Outdoor air Relative humidity
temperature 21°C 5°C % 35.3 58.5
Enthalpy
Fan blades value kJ/kg(DA) 27.8 12.9
Indoor dirty air Outdoor fresh air 17°C
after heat exchange Recycling coldkW 1.3 0
Heat loadkW 2 2

Filter
Clean air after heat exchanger Indoor air Discharge air

In winter operation, when the heat energy of 21°C air discharged


from indoor pass through the heat exchanger, the 5°C outdoor
Dry bulb
cold air is pre-heated to 17°C fresh air and supplied to indoors, temperature °C 21

as shown above, when outdoor 5°C air and indoor 21°C air pass Air Wet bulb
temperature °C
13
conditioning
through the HRV, the fresh air supplied to indoors is about 17°C, Relative humidity
%
39.2

the air conditioner only needs to heat the air by 4°C to maintain Enthalpy value kJ/kg(DA) 36.5

a comfortable room temperature and fresh air. The temperature


Airflow System recovery efficiency in heating is 75% max, and enthalpy exchange
efficiency is 63% max.

Air Exhaust
Dirty air exhaust
Fan motor
Air Return
Indoor dirty
air exhaust
Air Exhaust
Dirty air exhaust
Fan motor Fan motor
Blowing-in
clean air
enter house Very Low Noise
Fan motor

Through a low-noise fan motor, advanced internal silence


Air Inlet Blowing-in
Air Inlet
Air Return insulation device and optimization of air passage, the units have
Outdoor fresh air inlet clean air Indoor dirty
enter house Outdoor fresh air inlet air exhaust low noise.
HKF-15B2EC~HKF-100B2EC HKF-150B2EE~HKL-500B2EE The minimum operating noise is only 28dB (A), which will not
affect the user's sleep and rest at all.
Street Quiet Bedroom Hisense Total
library The noise of 30dB Heat Exchanger
will not affect sleep. HKF-15B1(2)EC*
117/118
VENTILATION SOLUTION​

Product Line

HKF-15B2EC
With Flexible Control, It Has Access to Centralized
Control of Hisense Air Conditioning System

Product Dimensions

Controller Total Heat Exchanger

LCD Wired Remote Controller - Standard


Electric
Control Box

Large LCD screen interface, elegant appearance


Can display room temperature, fan speed and so on
Air volume setting function, the user can choose high,
Air Exhaust-- Air Return-- Indoor
medium and low fan speed Dirty air exhausted dirty air exhausted
Product dimension:86*86mm
HYXE-M01H Air Intake-- Blowing-in--
Outdoor fresh Clean air blown indoor
air intake

Centralized Control System Model


HKF-15B2EC* Fresh air Dirty air

Hisense centralized control type total heat exchanger products can be connected to the centralized control system of
Hisense air conditioning*, achieve the linkage with air conditioning system and centralized control, so the operation is
more convenient and more intelligent! Technical Parameters

Air Volume m³/h Enthalpy Efficiency Enthalpy Efficiency External Static Noise
Power Input Current A Input Power KW dB(A)
Model (Summer) (Winter) Pressure Pa Level Weight
Supply kg
High Middle Low High Middle Low High Middle Low High Middle Low High Middle Low High Middle Low High Middle Low
HKF-15B2EC* 220-240V
/50HZ
. . . . . .
Computer centralized control

*: 220V/60Hz HKF-15B2E2
Outdoor unit

Product Feature
Adapter Compact Machine, Convenient Installation.
Indoor unit Indoor unit Total heat exchanger
The thickness of machine is not more than 270mm that
can be easily installed in the narrow residential ceiling.
The width of the machine whose volume is under 300
m³/h is less than 600mm, which is particularly suitable
Outdoor unit
for very narrow spaces in the ceiling, and can save the
space of installation and ceiling, it is more convenient
for construction.

Indoor unit Total heat exchanger


Indoor unit

Adjustable Air Volume, Quiet Operation. Medium Level: High level:


The air volume can be adjusted at a range of high, Nature warm Experience the
medium, or low level, the lowest noise in low level is and refreshing natural wind, enjoy
Low Level: enjoyed during aerobic exercise
only 28 dB(A) (HKF-15B1(2)EC in low level ), which Gentle and fine airflow, breathing
reaches the lowest level in the industry. tenderly caring baby-like sleep.
119/120
VENTILATION SOLUTION​

Product Line

HKF-25B2EC~HKF-100B2EC HKF-250B2EE~HKF-300B2EE

Product Dimensions
Product Dimensions
Electric
Control Box

Electric
Control Box

Blowing-in--
Air Exhaust-- Clean air
Dirty air exhausted blown indoor
Air Return--
Air Exhaust-- Model
Indoor dirty
Dirty air exhausted HKF-25B2EC*
air exhausted
HKF-35B2EC*
HKF-50B2EC*
HKF-65B2EC*
Air Intake--
HKF-80B2EC* Outdoor fresh Air Return--
HKF-100B2EC* air intake Indoor dirty
air exhausted
Air Intake-- Blowing-in--
Outdoor fresh Clean air
air intake blown indoor
Technical Parameters

Technical Parameters

* : AC3Ф220V/60Hz HKF-250B2E9 HKF-300B2E9


AC3Ф380V/60Hz HKF-250B2EF HKF-300B2EF

HKL-400B2EE~HKL-500B2EE
*: AC1Ф220V/60Hz HKF-25B2E2~HKF-100B2E2

Product Dimensions
HKF-150B2EE~HKF-200B2EE
Product Dimensions
Electric
Check hole Control Box

Electric
Control Box

Blowing-in--
Air Exhaust--
Air Exhaust-- Blowing-in-- Clean air
Dirty air exhausted
Dirty air Clean air blown indoor
exhausted blown indoor

Air Intake-- Air Intake-- Air Return--


Air Return-- Outdoor fresh Indoor dirty
Outdoor fresh Indoor dirty
air intake air intake air exhausted
air exhausted

Technical Parameters Technical Parameters

* : AC3Ф220V/60Hz HKF-150B2E9 HKF-200B2E9 * : AC3Ф220V/60Hz HKF-400B2E9 HKF-500B2E9


AC3Ф380V/60Hz HKF-150B2EF HKF-200B2EF AC3Ф380V/60Hz HKF-400B2EF HKF-500B2EF
121/122
VENTILATION SOLUTION​

Product Line

Selection and Limitation of Heat Exchanger of AHU


AHU Connection KIT
The Heat Exchanger of AHU(field-supplied)should be selected according to the following technical data and limitations.
Lifetime of the outdoor unit,operation range or operation reliability may be influenced if these limitations are neglected.

The Hisense AHU-KIT can integrate external heat exchangers of Air-handing units (AHU) into a Hisense VRF system to
be used for air conditioning,which can provide more flexible air conditioning solutions and save more cost in the building
air conditioning renovation.

Main Function
ON/OFF Control Temperature Setting Capacity Demand Operation Mode

Refrigerant pipe
Sensor signal
Communication wire

Control Box

HYXE-VA01

*Cooling and heating capacity data based on the following indoor and outdoor temperature conditions:

Expansion
Valve Box

AHU

DB:dry bulb;WB: wet bulb


Pipe Length:7.5m;pipe height:0m

Wired Controller Wired Controller


123/124

Control System

Wired Controller

Control HYXE-J01H
System Features:
4 inch large LCD screen with a resolution of 320×185.
Functions are displayed in iconic form, more intuitive. 120mm×120mm
Operation navigation, more convenient.
Wired Controller
Various displaying settings: backlit control, contrast ratio setting, backlit displaying time
Wireless Controller
setting, keytone setting, indicator light brightness setting, clock setting, language switch.
Receiver Kit for Wireless Control-optional
Max.16 indoor units can be connected.
Centralized Controller It can be used in main-auxiliary control mode.
Building Management System

Main Functions
Cooling/Heating/Dry/Fan/Auto Temperature Setting Timer
Error Code Display Check Air Filter Cleaning Reminding
Error History Display Mode Lock Address Setting
Fan speed/Swing Louver Weekly Timer Holiday Setting

Various Control Solutions Weekly Timer Setting


Five different schedule timers can be set for each day of the
week.

Indoor Unit Address Change

In the process of installation work, indoor unit address can


be changed through wired controller HYXE-J01H.
125/126
Control System Control System

Wired Controller
HYXM-VB01

HYXE-M01H Features:
Touchscreen, use fingers to tap objects on the touchscreen instead of keyboard.
Colorful and 3.5 inches. 86mm×90mm
Features:
Adjust the screen that is synchronous with running light for current light conditions.
Streamline appearance design, white highlight shell. The most accurate streamlined design in the industry.
Large LCD screen, humanized operation interface. 86mm×86mm Match all kinds of hisense VRF indoor units.
Touch key control, easy and convenient. Modify the address of indoor units.
White backlight; operation indicator light. Prevent children from touch by mistake.
Infrared remote control is acceptable, realizing two control method: wired control and remote control. Display room temperature.
Include wireless receiver.

Main Functions
Main Functions
86×86mm Smart Size Temperature Setting 72-hour Timer
Cooling/Heating/Dry/Fan/Auto Temperature Setting Timer
Cooling/Heating/Dry/Fan/Auto Check Air Filter Cleaning Reminding
Error History Display Check Air Filter Cleaning Reminding
Error Code Display Inserting Dehumidification
0.5 C Temperature Setting
o
Weekly Timer Address Setting
Multiple Speed/Swing Louver Backlight Max.6 indoor Units Can be Connected
3D Airflow Setting Auto-brightness Holiday Setting

Multiple Fan Speed Child Lock Auto-dehumidification

HYXE-VA01
Features:
New fashion appearance, big display LCD and touch button, and good user operation
HYXE-S01H
experience.
Support 6 level fan speed and 0.5oC temperature adjustment.
Supports low temperature automatic dehumidification. 120mm×120mm
Individual setting of wind deflector.
Features:
Support room temperature display and backlight brightness adjustment. Half-size design:120 mm×70mm×17mm.
Max. 16 indoor units connectable.
Support human sense control function (not available for Console IDU). 120mm×70mm
Icon Function Display.
Support health, sleep, mute, energy saving and breeze setting.

Main Functions
Main Functions
Cooling/Heating/Dry/Fan/Auto Temperature Setting Timer

Cooling/Heating/Dry/Fan/Auto 0.5℃ Temperature Setting 72-hour Timer 3 or 6 Speed Control Check Air filter Cleaning Reminding

Error Code Display Check Air Filter Cleaning Reminder Touch Buttons Quiet Dehumidification
Multiple Speed 3D Airflow Setting Backlight Control Fan Speed/Swing Louver Optional Setting Test Run
Swing Louver One Touch Test Run Max. 16 Indoor Units Can be Connected
Optional Setting
127/128
Control System Control System

Wireless Controller Centralized Controller

HYE-W01 HYJM-S01H
Features:
Features: 7-inch touch screen design.
Maximum 160 history alarm records information. 148mm×200mm
Different colors of common used keys. Multiple languages support. (Chinese, English, Spanish, Turkish, Russian, Italian, German, Dutch).
145mm×55mm
White backlight, convenient for night operation. Record accumulated operating time of each indoor unit.
Multi-functional, intelligent and humanized. Service contact information can be shown and setting.
Max.64 remote control groups and Max 160 indoor units are available.

Main Functions Main Functions


Clock Setting Time Display Mode Setting Energy Saving Control Mode Alarm History
Cooling/Heating/Dry/Fan/Auto Temperature Setting 24-hour Timer Backlight Holiday Setting Setting Temperature Limitation Service Hotline Setting
Power Indicator Backlight Brightness Adjusting Backlight Auto-off Time Adjusting Weekly Schedule
6 Fan Speed/Swing Louver Quiet Mode Setting Dehumidification

Sleep Mode Setting Smooth Appearance Easy Installation


53
220 Unit:mm 20 33 Unit:mm

148

Receiver Kit for Wireless Control - optional

Centralized ON/OFF Controller: HYJ-J01H


Features:
Large size touch-key control design Slim design with a thickness of 12.5mm
It can control up to 16 wired controller groups,realizing centralized ON/OFF control
Max.128 indoor units can be connected
120mm×120mm

Main Functions
Group Control(ON/OFF) Indoor Units Auto Login in Indoor Unit Power OFF Reminder Error Reminder

Compact Structure Design Centralized ON/OFF Control


129/130
Control System Control System

Type Wired Controller Wireless Controller


Model HYXE-VA01 HYXE-J01H HYXE-M01H HYXM-VB01 HYXE-S01H HYE-W01

Hi-Mit Picture

Ceiling Duct Type

4-Way Cassette

Mini 4-Way
Cassette
1-Way Cassette

2-Way Cassette

Ceiling&Floor √

Wall Mounted √
Suit for
indoor unit Floor Concealed

DC Low Height
AC Low Height
Console Type √

All Fresh Air Indoor


Unit
Heat Recovery

Ventilation
3D Air-flow Panel

AHU KIT

Centralized
Type Receiver Kit Controller ON/OFF

Model HYRE-V02H HYRE-T02H HYRE-X01H HYJM-S01H HYJ-J01H

Main Functions
Picture

Ceiling Duct Type


ON/OFF Control, Operation Mode, Temperature Setting
Operate According to a Schedule 4-Way Cassette

Display the Alarm Code Mini 4-Way


Cassette
16 operation modes
1-Way Cassette
Max. 32 Indoor Units Can be Controlled
Dimension: 215×137×38 mm 2-Way Cassette

Ceiling&Floor

Wall Mounted

Adapter Specifications Suit for Floor Concealed


indoor unit
DC Low Height
AC Low Height
Model name HYJE-H01H Operating Temperature 0 C~40 C
o o
Console Type
Input Voltage AC 110~240V 50/60Hz Maximum Operating Current 10mA (220 V) All Fresh Air Indoor
Unit
Heat Recovery
*The standard parts of this system includes the converter HYJE-H01H and the client control software HRM-G01 ( it can be downloaded Ventilation
and installed in the APP STORE ), The iPhone,iPad is the registered trademark of Apple Inc. 3D Air-flow Panel

AHU KIT

Remarks: ○ Optional × Incompatible √ Standard


131/132
Control System Control System

Building Management System


HCPC-H2M1C Modbus
Compatible to multiple communication protocol of BACnet, MODBUS etc. Connectible to BMS or Smart Home System
via HC-A64BNP or HCPC-H2M1C all of which can connect to Max. 64 indoor units.

Real-time operation status monitoring for inquiry


Operation order from monitoring center

HC-A64BNP BACnet

On-Off Setting Operating Mode Setting Airflow Setting and Monitoring Wind Setting and Monitoring

Temperature Setting Inlet Air Temp. Monitoring All Units On/Off Control Alarm Monitoring and Code Display

Converter Specifications

HC-A64BNP HCPC-H2M1C
Converter

Item

BMS Connection BACnet Modbus

Power Supply AC100~240V±10%(50/60Hz) AC100~240V±10%(50/60Hz)

Running-state Monitoring / On-off Setting Operating Mode Setting Temperature Setting and Monitoring Connectable Central Controller HYJM-S01H HYJM-S01H, Hi-Dom, HYJ-J01H

Airflow Setting and Monitoring Alarm Monitoring and Code Display Communication Failure Display MAX.Number of Connectable Indoor Units 64 64

Wireless Controller Permission/Prohibition Indoor Temp. Monitoring Filter Cleaning Prompting Dimension(LxWxH) 240mm×204mm×70mm 220mm×140mm×50mm
133/134
Control System Control System

BACnet
IntesisBox KNX – Hisense AC is a communication gateway for the integration of Hisense air conditioning
Intesis Box BACnet server makes available the Hisense VRF conditioning system through independent systems into KNX TP-1 (EIB).
BACnet objects. It can be applied to third party intelligent control system with BACnet/IP or BACnet MSTP Wide range of monitoring & control datapoints available.
protocol. Outdoor unit’s signals available for the integration.
Example: TOUCH SCREEN
Device as Slave
Main Functions

Central control of all indoor units Vane position swing control


Indoor unit data monitoring Function prohibition of wired controller H-NET

Heat/ Dry/ Fan/ Cool/ Auto mode control Indoor Unit

BACnet IP (Ethernet) Windows Energy Outdoor Unit


BMS blinds management
H-NET
H-NET

Indoor Unit
Alarms Lighting Indoor Unit

Outdoor Unit

Outdoor Unit HVAC


H-NET
BACnet MSTP (RS485)

Model H(mm) W(mm) D(mm) Max.number of connectable indoors units


Indoor Unit
KNX HS-RC-KNX-1i 70 70 28 1
Outdoor Unit
KNX HS-AC-KNX-16 90 88 56 16
KNX HS-AC-KNX-64 90 88 56 64
BACnet HS-AC-BAC-16 90 88 56 16
BACnet HS-AC-BAC-64 90 88 56 64

KNX Hi-Motion
intelligent sensor
Multiple objects for control and status (bit, byte, characters…) with KNX standard datapoint types.
Control of the AC unit based on the ambient temperature read by the own AC unit, or in the ambient temperature
read by any KNX thermostat.
Main Functions
Total Control and Monitoring of the AC unit from KNX, including monitoring of AC unit’s state of internal variables,
High Precision
running hours counter (for filter maintenance control), and error indication and error code.
Adjust AC temperature precisely according to the number of users
Up to 5 scenes can be saved and executed from KNX, fixing the desired combination of Operation Mode, Set
Temperature, Fan Speed, Vane Position and Remote Controller Lock at any moment by using a simple switching. Wide Range
Sense as much as 70m2 with almost no blind area

High Energy Conservation


Example: TOUCH SCREEN Turn off AC automatically when nobody is in the room
Device as Master

Hi-Motion
Remote control Switch Electrical Box of lndoor Unit Electrical Box of lndoor Unit

Terminal Board Terminal Board


REMOCON REMOCON
A B A B A B
A B M3.5 M3.5
Windows Energy Screws Screws
blinds management

Alarms Lighting
Twist Pair Cable with Shield Tube:1P-0.75MM2 or more
HVAC
135/136
Control System Control System

Hi-Dom Air Conditioning Management System Electric Charge Allocation


Hi-Dom air conditioning management system consists of meter reading system and air conditioning
management system. In accordance with the operation time and capacity output of indoor and outdoor
Centralized Control units, the electric charge allocation software allocates the total power consumption to each indoor unit.

Hi-Dom air conditioning management system adopts communication bus connection, air conditioning indoor units
are connected to the computer through network converter; the system is all controlled automatically by a computer Note:Due to different laws and regulations in different regions, Hisense electrical charge calculation
with powerful functions and simple operation. One single computer control system can manage 4,096 indoor units. software need to customize processing in project according to the users' requirement.

Note:Only support iEM3150 or iEM3350,

Main Functions which is supplied by Schneider Electric

Electric Meter

Running-state Monitoring Access Control


Determine the Temperature Limit Automatic Operation According to Settings
Running Records Display Multifunction Alarm
Controller Prohibition Function Service Monitoring

AC System

Power Supply
M-concentrator
Cable (Meter Reader)

Network Connector
AC System

Shielded Twisted Pair Cable

AC System

All the indoor units and outdoor units connected with one adapter comprise one communication BUS system.
Max.128 indoor units can be connected to an adapter.
Max.32 adapters can be controlled by one computer. Hi-Dom System Specifications
Max.4096 indoor units are under control.
Model Name Power Supply Dimension(mm) Charging Function
Adapter HCCS-H128H2C1YM DC 12V 180×110×40 With charging function
(Hi-Dom) HCCS-H128H2C1NM DC 12V 180×110×40 Without charging function
HCCS-H247R4C1E DC 12V 180×110×40
Note:HCCS-H247R4C1E is an essential equipment for HCCS-H128H2C1YM to charging.
137/138

Optional Parts

Selection Software

Optional
Parts
Support
Optional Parts

Hisense selection software is a Windows-based program which can run in Window XP and other higher operating
systems. This software supports multiple languages, and is convenient for users from different countries.Users
can get the latest updated products information easily, because Hisense selection software supports product
database update. Besides, this software is very intelligent. It not only supports manually drawing but also can
generate device piping diagram, wiring diagram and project detailed report automatically. Furthermore, the
software supports insertion of architectural drawing in DWG,PDF,JPG and PNG file formats, and designing on the
architectural drawing.
139/140
Support Optional Parts

Design Software CFD

What is CFD technology ?


CFD stands for Computational Fluid Dynamics, which is the
science of predicting fluid flow, heat transfer, mass transfer,
chemical reactions, and related phenomena by solving the
mathematical equations which govern these processes using a
numerical process (that is, on a computer).

What can we do with CFD technology ?


CFD is the best method to analyze the air flow of building
ventilation. It can provide the detailed and obvious simulation
result, for example, indoor airflow distribution and temperature
and velocity fields around the outdoor unit. These results will bring
some good design advice to the architect or consultant before
construction. In addition it’s very fast and low cost.

GCSS
Hisense VRF design software is based on Autocad 2008~2016 which supports both 32-bit and 64-bit operating
system. It involves the latest all ranges of products of Hisense, and supports online database update. The software Hisense GCSS(Global Customer Service System)is after-sales service online web-based System for Hisense VRF,
supports system calculating for refrigerant pipes and condensate pipes. Besides, the installation material and the it’s can be freely accessed by Hisense certificated service partners and Hisense agents. GCSS has 4 main functions,
amount of the refrigerant charge can be calculated through the software. So that users can design the system easily. including life-cycle project management, spare part support, warranty claim system and online call center.

BIM

BIM(Building Information Modeling )has


become an umbrella term to cover many
aspects.​ Hisense can provide up-to-date graphic
and parametric product information that is ready
to use in any BIM process. ​Hisense offers the
MEP engineers the needed Revit families and 3D
DWG's to optimize their BIM model.​
141/142
Optional Parts Optional Parts

Piping Connection Kit


Branch Pipe (For indoor unit)
Manifold Pipe (For outdoor unit)
First Branch Pipe
(Indoor Unit on Left Side)
Outdoor Unit A Outdoor Unit B Outdoor Unit C Outdoor Unit D
For Hi-FLEXi S Series Heat Pump System

Outdoor Unit HP 8 to 10 12 to 16 18 to 24 26 to 44 46 to 66 68 to 112


Branch Pipe HFQ-102F HFQ-162F HFQ-242F HFQ-302F HFQ-462F HFQ-682F

For Hi-FLEXi G+ Series 2-Pipe Heat Pump System


Outdoor Unit HP 8 to 10 12 to 16 18 to 24 26 to 44 46 to 66 68 to 88

b d e f g Branch Pipe HFQ-102F HFQ-162F HFQ-242F HFQ-302F HFQ-462F HFQ-682F


a
To Indoor Units c For Hi-FLEXi X High Efficiency Series Heat Pump System
Manifold Manifold Manifold
Pipe 1 Pipe 2 Pipe 3
Outdoor Unit HP 8 to 10 12 to 16 18 to 24 26 to 48 50 to 64
Branch Pipe HFQ-102F HFQ-162F HFQ-242F HFQ-302F HFQ-462F

For Hi-FLEXi S Series Heat Pump System


Outdoor Unit AVWT-290~422HKSS AVWT-444~544HKSS AVWT-552~634HKSS AVWT-654HKSS AVWT-676~816HKSS AVWT-824~886HKSS AVWT-908~1088HKSS
For Hi-FLEXi R Series 2-Pipe Heat Pump System
Manifold Pipe1 HFQ-M32F HFQ-M462F HFQ-M462F HFQ-M682F HFQ-M682F HFQ-M682F HFQ-M682F
Manifold Pipe2 HFQ-M32F HFQ-M32F HFQ-M462F HFQ-M462F HFQ-M462F Outdoor Unit HP 8 to 10 12 to 16 18 to 24 26 to 54
Manifold Pipe3 HFQ-M32F HFQ-M462F Branch Pipe HFQ-102F HFQ-162F HFQ-242F HFQ-302F

For Hi-FLEXi G+ Series Heat Pump System For Hi-FLEXi R Series Heat Recovery System

Outdoor Unit AVWT-232UKSZA AVWT-250~420UKSZA AVWT-438~630UKSZA AVWT-649~840UKSZA Outdoor Unit HP 8 to 10 12 to 16 18 to 24 26 to 36 38 to 54


Manifold Pipe1 HFQ-M22F HFQ-M32F HFQ-M462F HFQ-M682F Branch Pipe HFQ-M282F HFQ-M452F HFQ-M562F HFQ-M692F HFQ-M902F

Manifold Pipe2 HFQ-M32F HFQ-M32F


Manifold Pipe3 HFQ-M32F

For Hi-FLEXi X Series Heat Pump System First Branch Pipe~ Last Branch Pipe
Outdoor Unit AVWT-172~229UESZX AVWT-250~307UESZX AVWT-324~386UESZX AVWT-404~460UESZX AVWT-480~620UESZX
Manifold Pipe 1 HFQ-M22F HFQ-M32F HFQ-M32F HFQ-M32F HFQ-M462F
For Hi-FLEXi S Series 2-Pipe Heat Pump System
Manifold Pipe 2 HFQ-M22F HFQ-M32F HFQ-M32F
Manifold Pipe 3 HFQ-M32F Total Indoor Unit HP Lower than 6 6 to 8.99 9 to 11.99 12 to 15.99 16 to 17.99 18 to 25.99 26 to 33.99 34 to 45.99 46 to 58.99 59 to 68.99 Over 69

Gas (Φmm) 15.88 19.05 22.2 25.4 28.6 28.6 31.75 38.1 41.3 44.5 50.8
Liquid (Φmm) 9.53 9.53 9.53 12.7 12.7 15.88 19.05 19.05 22.2 22.2 25.4
For Hi-FLEXi R Series 2-Pipe Heat Pump System
Branch Pipe HFQ-102F HFQ-102F HFQ-102F HFQ-162F HFQ-162F HFQ-242F HFQ-302F HFQ-302F HFQ-462F HFQ-462F HFQ-682F
Outdoor Unit AVWT-190~232FE(7)SZ AVWT-250~340FE(7)SZ AVWT-364~510FE(7)SZ
Manifold Pipe 1 HFQ-M22F HFQ-M32F HFQ-M32F
Manifold Pipe 2 HFQ-M32F
For Hi-FLEXi G+ Series 2-Pipe Heat Pump System

Total Indoor Unit HP Lower than 6 6 to8.99 9 to11.99 12 to15.99 16 to17.99 18 to25.99 26 to33.99 34 to45.99 46 to57.99 58 to67.99 68
For Hi-FLEXi R Series Heat Recovery System
Gas (Φmm) Φ15.88 Φ19.05 Φ22.2 Φ25.4 Φ28.6 Φ28.6 Φ31.75 Φ38.1 Φ41.3 Φ44.5 Φ50.8
Outdoor Unit AVWT-190~232FE(7)SZ AVWT-250~340FE(7)SZ AVWT-364~510FE(7)SZ Φ19.05 Φ22.2 Φ22.2 Φ25.4
Liquid (Φmm) Φ9.53 Φ9.53 Φ9.53 Φ12.7 Φ12.7 Φ15.88 Φ19.05
Manifold Pipe 1 HFQ-M202F HFQ-M212F HFQ-M302F
Branch Pipe HFQ-102F HFQ-162F HFQ-242F HFQ-302F HFQ-462F HFQ-682F
Manifold Pipe 2 HFQ-M302F
143/144
Optional Parts Optional Parts

Manifold Pipe Parameter


For Hi-FLEXi X Series 2-Pipe Heat Pump System
Reducer for Reducer for
Model Gas Line Liquid Line
Total Indoor Unit HP Lower than 6 6 to 8.99 9 to 11.99 12 to 15.99 16 to 17.99 18 to 25.99 26 to 35.99 36 to 47.99 48 to 57.99 58 to 64 Gas Line Liquid Line
ID 25.4 ID 9.53
Gas (Φmm) 15.88 19.05 22.2 25.4 28.6 28.6 31.75 38.1 41.3 44.5 ID 28.6
ID 28.6
ID 25.4
ID 12.7
ID 15.88 ID 15.88 ID 25.4 ID 15.88
OD 28.6 ID 12.7
Liquid (Φmm) 9.53 9.53 9.53 12.7 12.7 15.88 19.05 19.05 22.2 22.2
HFQ-M22F Ø 25.4 Ø 22.2 Ø 25.4 Ø 19.05
Branch Pipe HFQ-102F HFQ-102F HFQ-102F HFQ-162F HFQ-162F HFQ-242F HFQ-302F HFQ-302F HFQ-462F HFQ-462F Ø 22.2 ID 22.2 ID 19.05
Ø 19.05
ID 22.2 ID 15.88 ID 9.53
ID 15.88
ID 19.05 ID 12.7 ID 6.35
ID 12.7

ID 38.1 ID 9.53 OD 31.75 ID 22.2


ID 22.2
ID 15.88

For Hi-FLEXi R Series 2-Pipe Heat Pump System


ID 31.75 ID 32.0 ID 19.05 ID 19.05 ID 28.6 ID 25.4 Q'ty : 1
ID 38.1 Ø 31.75 ID 25.4 ID 15.88
HFQ-M32F OD 28.6 ID 12.7
Ø 25.4 ID 12.7
Ø 19.05 ID 22.2 ID 22.2 ID 19.05 Q'ty : 1
Ø 31.75
Total Indoor Unit HP Lower than 6 6 to 8.99 9 to 11.99 12 to 15.99 16 to 17.99 18 to 25.99 26 to 35.99 Over 36 ID 15.88 Ø 22.2 OD 38.1
Ø 28.6 ID 12.7
ID 28.6 ID 9.53 ID 6.35
Gas (Φmm) Φ15.88 Φ19.05 Φ22.2 Φ25.4 Φ28.6 Φ28.6 Φ31.75 Φ38.1 ID 34.92 Q'ty : 1

ID41.3 ID9.53 OD31.75 ID28.6 ID22.2


Liquid (Φmm) Φ9.53 Φ9.53 Φ9.53 Φ12.7 Φ12.7 Φ15.88 Φ19.05 Φ19.05 ID44.5
ID31.75
ID38.1
ID22.2
ID19.05
ID12.7
ID15.88 ID25.4

Branch Pipe HFQ-102F HFQ-162F HFQ-242F HFQ-302F 25.4×t1.2 ID19.05


31.75×t1.2 ID25.4

HFQ-M462F 41.3×t2.0 38.1×t2.0 19.05×t1.0 ID22.2 ID25.4 ID15.88


25.4×t1.4 ID12.7
38.1×t2.0 ID15.88 ID25.4
ID31.75 ID9.53
ID28.6 ID12.7 28.6×1.2t ID19.05
ID38.1 ID6.35
ID22.2
ID28.6 ID22.2
ID50.8 OD31.75 ID28.6 ID22.2
For Hi-FLEXi R Series Heat Recovery System ID53.98
ID31.75
ID38.1 ID25.4
ID19.05
ID15.88
31.75×t1.2 ID25.4
HFQ-M682F
50.8×t2.5 28.6×t1.9 25.4×t1.45 ID25.4 ID15.88
Total Indoor Unit HP Lower than 6 6 to 8.99 9 to 11.99 12 to 15.99 16 to 17.99 18 to 21.99 22 to 25.99 26 to 35.99 Over 36 38.1×t2.0
ID12.7
38.1×t2.0 25.4×t1.45
ID31.75 ID19.05
ID28.6 ID22.2 28.6×1.2t ID19.05
ID38.1 ID15.88
Low Pressure Gas (Φmm) Φ15.88 Φ19.05 Φ22.2 Φ25.4 Φ28.6 Φ28.6 Φ28.6 Φ31.75 Φ38.1 ID22.2

High Pressure Gas (Φmm) Φ12.7 Φ15.88 Φ19.05 Φ22.2 Φ22.2 Φ22.2 Φ25.4 Φ28.6 Φ31.75
Low Pressure High Pressure Reducer for Reducer for Reducer for
Model Gas Line Gas Line Liquid Line Low Pressure High Pressure Liquid Line
Gas Line Gas Line
Liquid (Φmm) Φ9.53 Φ9.53 Φ9.53 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ19.05 Φ19.05

Branch Pipe HFQ-M142F HFQ-M282F HFQ-M452F HFQ-M562F HFQ-M692F HFQ-M902F


HFQ-M202F

Last Branch Pipe~Indoor Unit


Pipe Size (Φmm) HFQ-M212F
Indoor Unit Max. Liquid Pipe Length
Gas Pipe Liquid Pipe
7kBtu/h~14kBtu/h 12.7 6.35 15
17kBtu/h~18kBtu/h 15.88 6.35*1 15
22kBtu/h~54kBtu/h 15.88 9.53 40
76kBtu/h 19.05 9.53 40
96kBtu/h 22.2 9.53 40

HFQ-M302F
Notes 1. When liquid pipe length of indoor unit(07~18kBtu/h) is more than 15m, please change the liquid pipe dimension from Φ6.35 into Φ9.53.

Unit: mm, ID: Inner Diameter,OD: Outer Diameter


145/146
Optional Parts Optional Parts

Branch Pipe Parameter


Branch Pipe Parameterer
Low Pressure High Pressure Reducer for Reducer for Reducer for
Model Liquid Line Low Pressure High Pressure Liquid Line
Gas Line Gas Line Gas Line Gas Line
Reducer for Reducer for
Model Gas Line Liquid Line Gas Line Liquid Line

HFQ-052F HFQ-M142F

Q'ty :2

HFQ-102F
HFQ-M282F

Q'ty :2

HFQ-162F

HFQ-M452F

Q'ty :1 Q'ty :2 Q'ty :1

HFQ-242F

HFQ-M562F

Q'ty :1 Q'ty :2 Q'ty :1


HFQ-302F

Q'ty :1 Q'ty :1
HFQ-M692F

HFQ-462F
Q'ty :1
Q'ty :1

ID50.8 ID15.88
ID31.95
ID28.6
ID19.05
OD31.75 ID28.6 ID22.2 Q'ty :1 Q'ty :1
ID53.98 ID22.2
ID38.1
ID25.4
31.75×t1.2 ID25.4 HFQ-M902F
HFQ-682F Q'ty :1 Q'ty :1
50.8×t2.5 38.1×t2.0 25.4×t1.45 ID25.4 ID15.88
28.6×t1.9
ID12.7
38.1×t2.0
ID31.75 25.4×t1.45 ID19.05 Q'ty :1
ID22.2 28.6×1.2t ID19.05
ID28.6 ID15.88
ID38.1
ID22.2 Q'ty :1 Q'ty :1

Unit: mm, ID: Inner Diameter,OD: Outer Diameter


Unit: mm, ID: Inner Diameter,OD: Outer Diameter *with or without insulation, please contact our sales person or professional engineers
147/148
Optional Parts Optional Parts

Switch Box (heat recovery system only) Filter

Ceiling Ducted Type(Slim)

214mm
Model Applicable models Picture

AVE-07~14* HF-40L-ZFE

Others Hisense
Ceiling Ducted Type (Low&High Static Pressure)
301mm
Changeover box for heat recovery application
Compact and light design
Model Applicable models Picture
Minimized unit and less suspension bolts facilitate
191mm installation and handing methods
AVD-07~14* KW-PP1Q

AVD-17~24* KW-PP2Q
Specifications Indoor Unit Connection
Model AVD-27~38* KW-PP3Q
Specifications Number of
Net Weight(kg) Total HP
W×D×H(mm) Indoor Units*
AVD-48~54* KW-PP4Q
HCH-160D 6HP≥ 1~7
301×214×191 7 AVD-76* HF-224L-FE
HCH-280D 6.1HP to 10HP 1~8
AVD-96* HF-280L-FE

*When multiple indoor units are connected to the same switch box unit, they are controlled with the same operation
mode.

Drain Pump—Optional

3D Air-flow Panel
Model Power supply Consumption MAX. Lift Applicable models HPS-132/HPS-162 HPS-151
(mm)

HPS-132 AC 220~240V(50/60Hz) 9±1.5 W 900 For Ceiling ducted type(0.8~2.5Hp)

Panel Model Applicable Outer Dimensions Interface Dimension


HPS-162 AC 220~240V(50/60Hz) 9±1.5 W 900 For Ceiling ducted type(3.0~6.0Hp)
Models (H×W×D) (H×W×D)

HP-DB-NA 0.8-1.5HP 180×950×70 750×130 HPS-151 AC 220~240V(50/60Hz) 9±1.5 W 600 External type,for general purpose(0.8~10Hp)
HP-EB-NA 1.8-2.5HP 180×1220×70 1020×130

Note:For Ceiling Ducted Type (DC/AC Low-height) Note:For High Static Pressure Ceiling Ducted Type and Low Static Pressure Ceiling Ducted Type only.
Optional Parts

Technology

We are passionate about technology and making it accessible to


the world.
We believe that for technology to be truly innovative, it has to
be accessible. It's not about what it is; it's about what it does.
Technology connects us to our passion. It should make our world a
better place. It should make what we want to do, where we want to
go, and what we want to learn easier. And, it should be easy to use
and available to everyone. Our mission is to develop technological
innovations that improve the lives of others. We want our customers
to happily exclaim, "Life is better with Hisense."

Warranty
We are passionate about standing behind our products.
We believe that products should perform so well that customers
shouldn't need a warranty, but unexpected things happen.
Therefore, all our products come with a warranty to provide peace
of mind that, should something go wrong, we will stand behind our
products.

Quality & Value


We are passionate about building dependable, easy-to-use,
affordable products.
We believe the best things in life exceed expectations and that
everyone should be able to enjoy the benefits of state-of-the-
art technology. We take pride in the quality of our products. Our
stringent Quality Improvement Process helps ensure we offer
products that we're proud to sell and that you are proud to own. We
want you to feel confident when buying Hisense, because we're a
reliable brand that you can trust. Our "best value for your money"
commitment gives our customers assurance that buying Hisense is
the smart choice.

Service
We are passionate about making our customers happy.
We believe that manufactures need to be there after the sale.
Technology changes rapidly and sometimes you need a little
guidance along the way. Our service team is here to help. And, if
you should have a problem, we want to help get it solved as fast
as possible. Additionally, our service team works side-by-side
with R&D, engineering, sales and marketing to ensure company-
wide understanding of our customers and how our products are
performing.