Sie sind auf Seite 1von 14

Selection guide Ethernet network

Cabling system
ConneXium hub and transceiver

Type of device Hub

2 Interfaces Copper cable ports Number and type 4 x 10BASE-T ports


Shielded connectors RJ45
Medium Shielded twisted pair, category CAT 5E
Total length of pair 100 m
Fibre optic ports Number and type –

3 Connectors
Medium


Length of optical fibre 50/125 μm –
62.2/125 μm –
Optical fibre 50/125 μm fibre –
attenuation analysis 62.2/125 μm fibre –

4 Topology Number of hubs Cascaded Up to 4


In a ring –

Redundancy P1 and P2 redundant power supplies

Power supply Voltage 24 V c (18…32) safety extra low voltage (SELV)


5 Consumption 80 mA (130 max. at 24 V c)
Removable terminal block 5 terminals

Operating temperature 0…+ 60°C


Relative humidity 10… 95% non condensing
Degree of protection IP 30
6
Dimensions WxHxD 40 x 125 x 80 mm
Mounting On symmetrical DIN rail, 35 mm wide
Weight 0.530 kg

cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2,
7 Conforming to standards
e, GL, C-Tick
FM 3810, FM 3611 class 1 division 2

LED indicators Power supply, activity, link

Alarm relay Power supply fault, Ethernet network fault or communication port fault (volt-free contact
8 1 A max. at 24 V c)

Reference 499 NEH 104 10


Page 48384/6

10

2 version: 3.0 0517Q-EN.indd


Transceiver

1 x 100BASE-TX port
2
RJ45
Shielded twisted pair, category CAT 5E
100 m
1 x 100BASE-FX port
SC
Multimode optical fibre
3
3000 m (1)
3000 m (1)
8 dB
11 dB

– 4

P1 and P2 redundant power supplies

24 V c (18…32) safety extra low voltage (SELV)


160 mA (190 max. at 24 V c) 5
5 terminals

0…+ 60°C
10… 95% non condensing
IP 20
6
47 x 135 x 111 mm
On symmetrical DIN rail, 35 mm wide
0.230 kg

cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 Class 1 Division 2, e, GL, C-Tick
7
P1 and P2 power supplies, Ethernet link/port status

Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A max. at 24 V c)
8
499 NTR 101 00
48384/6
(1) Length dependent on the attenuation analysis and attenuation of the optical fibre (typical value: 2000 m).

10

0517Q-EN.indd version: 3.0 3


Selection guide (continued) Ethernet network
Cabling system
ConneXium unmanaged switches

Type of device Unmanaged switches, copper twisted pair

2
Interfaces Copper cable ports Number and type 5 x 10BASE-T/100BASE-TX ports 8 x 10BASE-T/100BASE-TX ports
Shielded connectors M12 (type D) RJ45
Medium Shielded twisted pair, category CAT 5E

3 Total length of pair 100 m


Fibre optic ports Number and type –
Connectors –
Medium –
Length of optical fibre 50/125 μm –
62.2/125 μm –
4 Optical fibre
attenuation analysis
50/125 μm fibre –

62.2/125 μm fibre –
Ethernet services Storage and re-routing of received data, –
auto MDI/MDX, automatic negotiation of
10/100 Mbps and duplex mode (on all ports)

5
Topology Number of switches Cascaded Unlimited
Redundant in a ring –

Redundancy – P1 and P2 redundant power supplies

Power supply Voltage 24 V c (18…32) safety extra low voltage (SELV)


6 Consumption 100 mA max. 125 mA (290 mA max.)
Removable terminal block 5 terminals, M12 (type A, male) 5 terminals

Operating temperature 0…+ 60°C


Relative humidity – 10… 95% non condensing
Degree of protection IP 67 IP 20
7 Dimensions WxHxD 60 x 126 x 31 mm 47 x 135 x 111 mm
Mounting On a flat surface On symmetrical DIN rail, 35 mm wide
Weight 0.210 kg 0.230 kg

Conforming to standards cUL 508 and CSA 22.2 No. 142 cUL 60950, UL 508 and CSA 22.2 No. 142,
8 UL 1604 and CSA 22.2 No. 213 class 1
division 2, e, GL, C-Tick

LED indicators Power supply, link status, data rate P1 and P2 power supplies, Ethernet link/port
status

– Power supply fault, Ethernet network fault or


9 Alarm relay
communication port fault (volt-free contact 1 A
max. at 24 V c)

Reference TCS ESU 051F0 499 NES 181 00


Page 48384/7

10

4 version: 3.0 0517Q-EN.indd


Unmanaged switches, copper Unmanaged switches, 4 and 5 ports, copper twisted pair and fibre optic
twisted pair (continued)

2
8 x 10BASE-T/100BASE-TX ports 3 x 10BASE-T/100BASE-TX ports 4 x 10BASE-T/100BASE-TX ports 5 x 10BASE-T/100BASE-TX ports
RJ45 RJ45
Shielded twisted pair, category Shielded twisted pair, category CAT 5E
CAT 5E
100 m 100 m 3
– – 1 x 100BASE-FX port –
– – Duplex SC –
– – Multimode optical fibre –
– – 5000 m (1) –
– – 4000 m (1) –
– – 8 dB – 4
– – 11 dB
Storage and re-routing of received Storage and re-routing of received data, auto MDI/MDX, automatic
data, auto MDI/MDX, automatic negotiation of 10/100 Mbps and duplex mode (on all ports)
negotiation of 10/100 Mbps and
duplex mode (on all ports),
automatic change of polarity
5
Unlimited Unlimited
– –

– –

24 V c (9.6…32) SELV 24 V c (9.6…32 V) safety extra low voltage (SELV)


4.1 W max. 2.2 W max. 3.9 W max. 2.2 W max. 6
3 terminals Removable screw terminal block, 3 terminals

0…+ 60°C 0…+ 60°C


95% max. non condensing 95% max. non condensing
IP 30 IP 30

35 x 138 x 121 mm 25 x 114 x 79 mm


7
On symmetrical DIN rail, 35 mm wide
0.246 kg 0.113 kg 0.120 kg 0.113 kg

UL 508 and CSA 22.2 No.142 UL 508 and CSA 22.2 No. 142
IEC/EN 61131-2,
IEC 60825-1 class 1, CISPR 11A
IEC/EN 61131-2, IEC 60825-1 class 1, CISPR 11A
8
Power supply, copper port activity, Power supply, copper port activity, 10 or 100 Mbps data rate
10 or 100 Mbps data rate
– Fibre port activity and status –

– –
9
TCS ESU 083FN0 TCS ESU 033FN0 TCS ESU 043F1N0 TCS ESU 053FN0
48384/7 48384/8
(1) Length dependent on the attenuation analysis and attenuation of the optical fibre (typical value: 2000 m).
10

0517Q-EN.indd version: 3.0 5


Selection guide (continued) Ethernet network
Cabling system
Managed and unmanaged ConneXium switches

Type of device Unmanaged switches, 5 ports, copper twisted pair and fibre optic

2
Interfaces Copper cable ports Number and type 4 x 10BASE-T/ 3 x 10BASE-T/ 4 x 10BASE-T/ 3 x 10BASE-T/
100BASE-TX ports 100BASE-TX ports 100BASE-TX ports 100BASE-TX ports
Shielded connectors RJ45
Medium Shielded twisted pair, category CAT 5E
Total length of pair 100 m

3 Fibre optic ports Number and type 1 x 100BASE-FX


port
2 x 100BASE-FX
ports
1 x 100BASE-FX
port
2 x 100BASE-FX
ports
Connectors SC
Medium Multimode optical fibre Single mode optical fibre
Length of optical fibre 50/125 μm 5000 m (1) –
62.2/125 μm 4000 m (1) –
9/125 μm fibre – 32,500 m (2)
4 Optical fibre
attenuation analysis
50/125 μm fibre 8 dB –
62.2/125 μm fibre 11 dB –
9/125 μm fibre – 16 dB
Ethernet services –

Topology Number of switches Cascaded Unlimited


5 Redundant in a ring –

Redundancy P1 and P2 redundant power supplies

Power supply Voltage 24 V c (18…32 V) safety extra low voltage (SELV)


Consumption 200 mA max. 240 mA max. 200 mA max. 240 mA max.

6 Removable terminal block 5 terminals

Operating temperature - 40...+ 70°C


Relative humidity 10… 95% non condensing
Degree of protection IP 20

Dimensions WxHxD 47 x 135 x 111 mm


7 Mounting On symmetrical DIN rail, 35 mm wide
Weight 0.330 kg 0.335 kg 0.330 kg 0.335 kg

Conforming to standards cUL 60950, cUL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2,
e, GL, C-Tick

8 LED indicators P1 and P2 power supplies, Ethernet link status, transmission activity

Alarm relay Activity, power supply fault, Ethernet network fault or communication port fault (volt-free contact
1 A max. at 24 V c)

Reference 499 NMS 251 01 499 NMS 251 02 499 NSS 251 01 499 NSS 251 02

9 Page 48384/8
(1) Length dependent on the attenuation analysis and attenuation of the optical fibre (typical
value: 2000 m).
(2) Length dependent on the attenuation analysis and attenuation of the optical fibre (typical
value: 15,000 m).

10

6 version: 3.0 0517Q-EN.indd


Managed switches, 4 ports, copper twisted pair and fibre optic

2
3 x 10/100BASE-TX ports 2 x 10/100BASE-TX ports 3 x 10/100BASE-TX ports 2 x 10/100BASE-TX ports

RJ45
Shielded twisted pair, category CAT 5E
100 m
1 x 100BASE-FX port 2 x 100BASE-FX ports 1 x 100BASE-FX port 2 x 100BASE-FX ports
3
Duplex SC
Multimode optical fibre Single mode optical fibre
5000 m (1) –
4000 m (1) –
– 32,500 m (2)
8 dB – 4
11 dB –
– 16 dB
FDR, SMTP V3, SNTP client, multicast filtering for optimization of the Global Data protocol, configuration via Web access,
VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port

Unlimited
Up to 50 5
Redundant power supplies, redundant single ring, ring coupling

9.6...60 V c/18…30 V a safety extra low voltage (SELV)


6.5 W 7.3 W 6.5 W 7.3 W
6 terminals
6
0…+ 60°C
10… 90% non condensing
IP 20

47 x 131 x 111 mm
On symmetrical DIN rail, 35 mm wide
7
0.400 kg

IEC 61131-2, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 142 (cUL), CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick

Power supply status, alarm relay status, active redundancy, redundancy management, copper port status and copper port activity
8
Power supply fault, Ethernet network fault, communication port fault, redundancy fault (volt-free contact 1 A max. at 24 V c)

TCS ESM 043F1CU0 TCS ESM 043F2CU0 TCS ESM 043F1CS0 TCS ESM 043F2CS0

48384/9
(1) Length dependent on the attenuation analysis and attenuation of the optical fibre (typical value: 2000 m).
9
(2) Length dependent on the attenuation analysis and attenuation of the optical fibre (typical value: 15,000 m).

10

0517Q-EN.indd version: 3.0 7


Selection guide (continued) Ethernet network
Cabling system
ConneXium managed switches

Type of device Managed switches, 4 and 8 ports, copper twisted pair

2 Interfaces Copper cable ports Number and type 4 x 10/100BASE-TX ports 8 x 10/100BASE-TX ports

Shielded connectors RJ45


Medium Shielded twisted pair, category CAT 5E
Total length of pair 100 m
Fibre optic ports Number and type –

3 Connectors
Medium


Length of optical fibre 50/125 μm –
62.2/125 μm –
9/125 μm fibre –
Attenuation analysis 50/125 μm fibre –
62.2/125 μm fibre –
4 9/125 μm fibre –
Ethernet services FDR, SMTP V3, SNTP client, multicast filtering for optimization of the Global Data protocol,
configuration via Web access, VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol),
priority port, data stream control, secure port

Topology Number of switches Cascaded Unlimited


Redundant in a ring Up to 50
5
Redundancy P1 and P2 redundant power supplies, redundant single ring, ring coupling

Power supply Voltage 9.6...60 V c/18…30 V a safety extra low voltage (SELV)
Consumption 5.3 W
Removable terminal block 6 terminals

6 Operating temperature 0...+ 60°C


Relative humidity 10… 90% non condensing
Degree of protection IP 20

Dimensions WxHxD 47 x 131 x 111 mm 74 x 131 x 111 mm

7 Mounting On symmetrical DIN rail, 35 mm wide


Weight 0.400 kg 0.410 kg

Conforming to standards IEC/EN 61131-2, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 214 (cUL),
CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick

LED indicators Power supply status, alarm relay status, Power supply status, alarm relay status,
8 active redundancy, redundancy management,
copper port status and copper port activity
active redundancy, redundancy management,
fibre port status and fibre port activity

Alarm relay Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A
max. at 24 V c)

Reference TCS ESM 043F23F0 TCS ESM 083F23F0


9 Page 48384/9

10

8 version: 3.0 0517Q-EN.indd


Managed switches, 8 ports, copper twisted pair and fibre optic

7 x 10/100BASE-TX ports 6 x 10/100BASE-TX ports 7 x 10/100BASE-TX ports 6 x 10/100BASE-T ports 2


RJ45
Shielded twisted pair, category CAT 5E
100 m
1 x 100BASE-FX port 2 x 100BASE-FX ports 1 x 100BASE-FX port 2 x 100BASE-FX ports
Duplex SC
Multimode optical fibre Single mode optical fibre
3
5000 m (1) –
4000 m (1) –
– 32,500 m (2)
8 dB –
11 dB –
– 16 dB 4
FDR, SMTP V3, SNTP client, multicast filtering for optimization of the Global Data protocol, configuration via Web access,
VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port

Unlimited
Up to 50
5
Redundant power supplies, redundant single ring, ring coupling

9.6...60 V c/18…30 V a safety extra low voltage (SELV)


6.5 W 7.3 W 6.5 W 7.3 W
6 terminals

0…+ 60°C 6
10… 90% non condensing
IP 20

75 x 131 x 111 mm
On symmetrical DIN rail, 35 mm wide
7
0.410 kg

IEC/EN 61131-2, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 214 (cUL), CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick

Power supply status, alarm relay status, active redundancy, redundancy management, fibre port status and fibre port activity
8
Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A max. at 24 V c)

TCS ESM 083F1CU0 TCS ESM 083F2CU0 TCS ESM 083F1CS0 TCS ESM 083F2CS0
48384/10
9
(1) Length dependent on the attenuation analysis and attenuation of the optical fibre (typical value: 2000 m).
(2) Length dependent on the attenuation analysis and attenuation of the optical fibre (typical value: 15,000 m).

10

0517Q-EN.indd version: 3.0 9


Selection guide (continued) Ethernet network
Cabling system
Basic ConneXium managed switches

Type of device Basic managed switch, 8 ports, copper twisted pair

2 Interfaces Copper cable ports Number and type 8 x 10/100BASE-TX ports


Shielded connectors RJ45
Medium Shielded twisted pair, category CAT 5E
Total length of pair 100 m
Fibre optic ports Number and type –
Connectors –
3 Medium
Length of optical fibre 50/125 μm


62.2/125 μm –
9/125 μm fibre –
Attenuation analysis 50/125 μm fibre –
62.2/125 μm fibre –

4 Ethernet services
9/125 μm fibre –
FDR, SNTP client, multicast filtering for optimization of the Global Data protocol, configuration
via Web access, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port

Topology Number of switches Cascaded Unlimited


Redundant in a ring Up to 50

5 Redundancy P1 and P2 redundant power supplies, redundant single ring, ring coupling

Power supply Voltage 9.6...32 V c safety extra low voltage (SELV)


Consumption 6W
Removable terminal block 6 terminals

Operating temperature 0...+ 60°C


6 Relative humidity 95% max. non condensing
Degree of protection IP 20

Dimensions WxHxD 47 x 131 x 111 mm


Mounting On symmetrical DIN rail, 35 mm wide
0.400 kg
7 Weight

Conforming to standards IEC/EN 61131-2, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 214 (cUL),
CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick

LED indicators Power supply status, alarm relay status, active redundancy, redundancy management,
copper port status and copper port activity

8 Alarm relay Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A
max. at 24 V c)

Reference TCS ESB 083F23F0


Page 48384/10

10

10 version: 3.0 0517Q-EN.indd


Basic managed switches, 8 and 9 ports, copper twisted pair and fibre optic

6 x 10/100BASE-TX ports 6 x 10/100BASE-TX ports 2


RJ45
Shielded twisted pair, category CAT 5E
100 m
2 x 100BASE-FX ports 3 x 100BASE-FX ports
Duplex SC
Multimode optical fibre
5000 m (1)
3
4000 m (1)

8 dB
11 dB

FDR, SNTP client, multicast filtering for optimization of the Global Data protocol, configuration via Web access, IGMP Snooping,
4
RSTP (Rapid Scanning Tree Protocol), priority port

Unlimited
Up to 50

P1 and P2 redundant power supplies, redundant single ring, ring coupling


5
9.6...32 V c safety extra low voltage (SELV)
8W 9W
6 terminals

0…+ 60°C
95% max. non condensing 6
IP 20

74 x 131 x 111 mm
On symmetrical DIN rail, 35 mm wide
0.400 kg
7
IEC/EN 61131-2, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 214 (cUL), CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick

Power supply status, alarm relay status, active redundancy, redundancy management, fibre port status and fibre port activity

Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A max. at 24 V c) 8
TCS ESB 083F2CU0 TCS ESB 093F2CU0
48384/10
(1) Length dependent on the attenuation analysis and attenuation of the optical fibre (typical value: 2000 m).
(2) Length dependent on the attenuation analysis and attenuation of the optical fibre (typical value: 15,000 m). 9

10

0517Q-EN.indd version: 3.0 11


Selection guide (continued) Ethernet network
Cabling system
ConneXium managed switches

Type of device Managed switches, 8 extended ports, copper twisted pair and fibre optic

2 Interfaces Copper cable ports Number and type 8 x 10/100BASE-TX ports 6 x 10/100BASE-TX ports 6 x 10/100BASE-T ports
Shielded connectors RJ45
Medium Shielded twisted pair, category CAT 5E
Total length of pair 100 m
Fibre optic ports Number and type – 2 x 100BASE-FX ports
Connectors – Duplex SC
3 Medium – Multimode optical fibre Single mode optical fibre
Length of optical fibre 50/125 μm – 5000 m (1) –
62.2/125 μm – 4000 m (1) –
9/125 μm fibre – – 32,500 m (2)
Attenuation analysis 50/125 μm fibre – 8 dB –
62.2/125 μm fibre – 11 dB –
4 Ethernet services
9/125 μm fibre – – 16 dB
FDR, SMTP V3, SNTP client, multicast filtering for optimization of the Global Data protocol,
configuration via Web access,VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol),
priority port, data stream control, secure port

Topology Number of switches Cascaded Unlimited


Redundant in a ring Up to 50

5 Redundancy Redundant power supplies, redundant single ring, ring coupling,


rings supporting MRP, Fast Hiper Ring and RSTP

Power supply Voltage 18...60 V c


Consumption 10 W 12 W
Removable terminal block 2 terminal blocks, 2 terminals

6 Operating temperature 0...+ 60°C


Relative humidity 10… 90% non condensing
Degree of protection IP 30

Dimensions WxHxD 120 x 137 x 115 mm

7 Mounting On symmetrical DIN rail, 35 mm wide


Weight 1 kg

Conforming to standards IEC/EN 61131-2, IEC 61850-3, UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 214 (cUL),
CSA 22.2 No. 213 class 1 division 2 (cUL), e, GL, C-Tick, LR, BV

8
LED indicators Power supply status, alarm relay status, active redundancy, redundancy management, copper
port status and copper port activity

Alarm relay Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A
9 max. at 24 V c, 2-way)

Reference TCS ESM 083F23F1 TCS ESM 063F2CU1 TCS ESM 063F2CS1

Page 48384/10
(1) Length dependent on the attenuation analysis and attenuation of the optical fibre (typical
value: 2000 m).
10 (2) Length dependent on the attenuation analysis and attenuation of the optical fibre (typical
value: 15,000 m).

12 version: 3.0 0517Q-EN.indd


Managed switches, 16 and 24 ports, copper twisted pair and fibre optic

16 x 10/100BASE-TX ports 14 x 10/100BASE-TX ports 14 x 10/100BASE-TX ports 22 x 10/100BASE-TX ports 2


RJ45
Shielded twisted pair, category CAT 5E
100 m
– 2 x 100BASE-FX ports
– Duplex SC
– Multimode optical fibre Single mode optical fibre Multimode optical fibre 3
– 5000 m (1) – 5000 m (1)
– 4000 m (1) – 4000 m (1)
– – 32,500 m (2) –
– 8 dB – 8 dB
– 11 dB – 11 dB
– – 16 dB
FDR, SMTP V3, SNTP client, multicast filtering for optimization of the Global Data protocol, configuration via Web access,
– 4
VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream control, secure port

Unlimited
Up to 50

Redundant power supplies, redundant single ring, ring coupling


5
9.6...60 V c/18…30 V a safety extra low voltage (SELV)
9.4 W 11.8 W 11.8 W 15.5 W
6 terminals

0…+ 60°C
6
10… 90% non condensing 95% max. non condensing 10… 90% non condensing
IP 20

111 x 131 x 111 mm


On symmetrical DIN rail, 35 mm wide 7
0.600 kg 0.650 kg

cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 IEC/EN 61131-2, cUL 60950, UL 508 and
class 1 division 2 UL 508, UL 1604 class 1 division 2, CSA 22.2 No. 142, UL 1604 and
CSA 22.2 No. 214 (cUL), CSA 22.2 No. 213 class 1 division 2
CSA 22.2 No. 213 class 1 division 2
(cUL), e, GL, C-Tick
8
Power supply status, alarm relay Power supply status, alarm relay status, active redundancy, redundancy management, fibre port status and fibre port
status, active redundancy, activity
redundancy management, copper
port status and copper port activity

Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A max. at 24 V c)
9
TCS ESM 163F23F0 TCS ESM 163F2CU0 TCS ESM 163F2CS0 TCS ESM 243F2CU0
48384/11
(1) Length dependent on the attenuation analysis and attenuation of the optical fibre (typical value: 2000 m).

10

0517Q-EN.indd version: 3.0 13


Selection guide (continued) Ethernet network
Cabling system
ConneXium managed switches

Type of device Managed switch, 8 ports and 2 Gigabit ports, copper twisted pair and fibre optic

2 Interfaces Copper cable ports Number and type 8 x 10/100BASE-TX ports

Shielded connectors RJ45


Medium Shielded twisted pair, category CAT 5E
Total length of pair 100 m
Fibre optic Number and type 2 x 1000BASE-SX ports (1) 2 x 1000BASE-LH ports (2) 2 x 1000BASE-LX ports (3)
Gigabit ports
3 (with SFP fibre optic
Connectors
module to be mounted Medium
LC
Multimode optical fibre Single mode optical fibre Single mode and multimode
on SFP connector) optical fibre
Length of optical fibre 50/125 μm 550 m – 550 m
62.2/125 μm 275 m – 550 m
9/125 μm fibre – 8 - 72,000 m 20,000 m
Attenuation analysis 50/125 μm fibre 7.5 dB – 11 dB
4 62.2/125 μm fibre 7.5 dB – 11 dB
9/125 μm fibre – 6 - 22 dB 11 dB
Ethernet services FDR, SMTP V3, SNTP client, multicast filtering for optimization of the Global Data protocol,
configuration via Web access, VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol),
priority port, data stream control, secure port

Topology Number of switches Cascaded Unlimited


5 Redundant in a ring Up to 50

Redundancy Redundant power supplies, redundant single ring, ring coupling

Power supply Voltage 9.6...60 V c/18…30 V a safety extra low voltage (SELV)
Consumption 8.9 W + 1 W per SFP fibre optic module
6 Removable terminal block 6 terminals

Operating temperature 0...+ 60°C


Relative humidity 10… 90% non condensing

Degree of protection IP 20

7 Dimensions WxHxD 111 x 131 x 111 mm


Mounting On symmetrical DIN rail, 35 mm wide
Weight 0.410 kg

Conforming to standards cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2,
e, GL

8 LED indicators Power supply status, alarm relay status, active redundancy, redundancy management,
fibre port status and fibre port activity

Alarm relay Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A
max. at 24 V c)

Reference TCS ESM 103F23G0


9
Page 48384/11
(1) With TCS EAA F1LFU00 fibre optic module to be ordered separately (see page 48384/5).
(2) With TCS EAA F1LFH00 fibre optic module to be ordered separately (see page 48384/5).
(3) With TCS EAA F1LFS00 fibre optic module to be ordered separately (see page 48384/5).

10

14 version: 3.0 0517Q-EN.indd


Managed switch, 8 ports and 2 Gigabit ports, copper twisted pair

8 x 10/100BASE-TX ports and


2 x 10/100/1000BASE-TX ports (Gigabit)
2
RJ45
Shielded twisted pair, category CAT 5E
100 m

LC

3




– 4

FDR, SMTP V3, SNTP client, multicast filtering for optimization of the Global Data protocol, configuration via Web access, VLAN, IGMP Snooping, RSTP (Rapid
Scanning Tree Protocol), priority port, data stream control, secure port

Unlimited
Up to 50 5
Redundant power supplies, redundant single ring, ring coupling

9.6...60 V c/18…30 V a safety extra low voltage (SELV)


8.3 W
6 terminals 6
0...+ 60°C
10… 90% non condensing

IP 20

111 x 131 x 111 mm 7


On symmetrical DIN rail, 35 mm wide
0.410 kg

cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 class 1 division 2, e, GL

Power supply status, alarm relay status, active redundancy, redundancy management, fibre port status and fibre port activity
8
Power supply fault, Ethernet network fault or communication port fault (volt-free contact 1 A max. at 24 V c)

TCS ESM 103F2LG0


9
48384/11

10

0517Q-EN.indd version: 3.0 15

Das könnte Ihnen auch gefallen