1. Find the real power (average) power loss and power factor for each of the
Circuits whose input current and voltage are as follows:
a. v = 60 sin(wt + 30) c. v = 50 sin(wt + 80)
i = 15 sin(wt + 60) i = 3 cos(wt - 20)
Load I
E = IOOV L90°
+
'\J
-I.,
200VAR (L)
ow
Load 2
600VAR(C)
__
Load 3 .___
OVAR
IOOW 300W
Ve
+ Xe -
63.3 .0
+ I
E = 250 VLO" I\J R Vn - 125 V L60°
- 20.0 +
VL
4. Determine the power information of each of the load connected parallel:
Load 1: 250 VA, pf=0.5 lagging
Load 2: 180 W, pf= 0.8 leading
Load 3: 300 VA, 100 VAR (inductive)
What is the overall power information and its pf.?
5. A two element series circuit has average power 940 W and power factor O. 707 leading.
Determine the circuit elements if the applied voltage is v=99.0 sin (6000t + 30).
6. Three impedance are in series: Z 1 = 3.0 /j_s0 0 , Zz = 10{2 J45~ 0 , Z3 = 5.0 J-90 0.
Find the applied voltage E, if the voltage across Z1 is 27.0 t10° V.
7. An industrial client is charged a penalty if the plant power factor drops below 0.85.
The equivalent plant loads are listed below. It is supplied with a source of 600 V and
Frequency of 60 Hz.
Load 1: 12 kW (lights)
Load 2: 2.3 + j3.2 0 (electric furnace), L = 150 A (current of electric furnace)
Load 3: 80 kW, pf 0.8 lagging (motor loads)
a. Determine the total average ( real) power and reactive power
b. Determine the amount of reactive power to bring power factor to 0.85
c. Determine the supply current before and after correction.
182 VA 772 VA
~----t Fp =0.8 - - Fp =0.385
15-A (lag) (lead)
+ fuse
278W
521 VAR
(ind.)
9. Find the two elements of a series circuit having a current of i = 4.24 sin(5000t+45) A,
power 180 W and power factor 0.8 lagging.
10. Two circuit elements in series connection have the current and voltage
i = 4.0 cos (2000t + 13.2) A
v = 200 sin (2000t + 50) V
Identify the two elements.